Search NASA⌕ Search

SEARCH · Search NASA

Results for “Contaminants”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Decontamination of urban surfaces contaminated with radioactive materials and consequent onsite recycling of the waste water

Enhancing rapid remediation strategies is paramount for recovery after a large-scale nuclear contamination event in an urban environment. Some current strategies recommend use of readily available equipment, materials, and facilities to expedite recovery. For example, applying pressurized water to contaminated surfaces may effectively remove radioactive contamination. In this study, a commercial power washer removes soluble forms of 152 Eu 3 + , 85 Sr 2 + , and 137 Cs + contamination from common porous building materials, and computer simulations characterize the recycling of the resultant contaminated wash water. Pressure washing the porous building materials under spray conditions typical with do-it-yourself units improved decontamination factors (DFs) for 152 Eu compared to low-pressure application of tap water (majority of two-tailed t-test p-values < 0.1), but pressure did not improve DFs for 137 Cs or 85 Sr. For both pressurized and low-pressure applications, adding potassium ions (K + ) to promote ion exchange reactions produced significantly higher DFs for tested radionuclides on asphalt, brick, and concrete. The resultant contaminated wash water can be processed through self-prepared chemical filtration beds of clay and sand. Modeled in a prior study, the beds yielded linear trends (R 2 > 0.98) in sensitivity analyses between most bed configuration variables and bed performance variables, permitting flexible ad-hoc bed design. The experimental and simulation results led to estimates of the remediation rate and waste generated after cleaning 250 m 2 of cesium-contaminated concrete from the combined deployment of a power washer and two different mobile treatment beds. Furthermore, the first treatment bed was designed to reduce treatment time and processed 1900 L of wash solution in 70 min using 880 kg of clay/sand infill material. Designed to reduce the solid waste generated, the second bed processed the same solution volume in 1040 min (17 h) using 170 kg of clay/sand infill material. The results of this analysis warrant further investigation of power washing with recycled salt solution as an effective rapid decontamination method with manageable waste.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Solvent-mediated contaminant removal from plastic waste using thermodynamic modeling

Plastics recycling is hindered by the compositional complexity of plastic waste, which can include numerous polymer components as well as low concentrations of additives and non-intentionally added substances. These latter small-molecule species, which we collectively refer to as contaminants, can harm human health and will build up in recycled plastic causing environmental and downstream processing challenges if not removed. In this work, we present molecular modeling approaches using the COnductor-like Screening MOdel for Real Solvents (COSMO-RS) to guide the selection of solvents that are capable of removing targeted contaminants from plastic waste. By considering the thermodynamic partitioning of contaminant species between a solvent phase and polymer phase, we identify guidelines for solvent selection to promote either the low-temperature extraction of contaminants from plastic waste or the removal of contaminants as part of a dissolution-based plastics recycling process. We present four case studies to illustrate the application of the computational approach to the removal of brominated flame retardants, phthalates, and selected perfluoroalkyl substances, and compare to both literature and newly collected experimental data to illustrate model prediction accuracy. Furthermore, the case studies highlight the capability of the modeling approach to help design recycling processes that explicitly account for contaminant removal, thereby increasing product purity during dissolution-based recycling or facilitating chemical recycling of contaminant-free plastics.

Zhou, Panzheng [University of, Wisconsin, Madison,↗

Accumulation of trace elements in soil and fauna within a site historically contaminated with coal combustion residues

Legacy contaminants tied to energy production are a worldwide concern. Coal combustion residues (CCRs) contain high concentrations of potentially toxic trace elements such as arsenic (As), mercury (Hg), and selenium (Se), which can persist for decades after initial contamination. Coal combustion residue disposal methods, including aquatic settling basins and landfills, can facilitate environmental exposure through intentional and accidental releases. Wildlife exposed to CCRs can experience numerous deleterious effects, such as on development, reproduction, and survival. In the current study, we quantified and compared concentrations of As, Hg, Se, and strontium (Sr) within soils and target fauna (three vertebrate and three invertebrate taxa) from a CCR-contaminated site and a reference site within the U.S. Department of Energy’s Savannah River Site, South Carolina, United States. Our objectives were to (1) compare current concentrations of tested elements in soil and resident fauna to levels from our reference site, (2) assess natural attenuation of elements in soils by comparing current concentrations to historic levels, and (3) evaluate the biomagnification potential of the elements measured via body burden and trophic position correlations among fauna. Here, element concentrations were higher in contaminated soils than reference soils; however, concentrations in 2022 were unchanged from concentrations measured in 2003, suggesting no natural attenuation of tested elements. Additionally, target fauna had elevated As, Se, and Sr levels in comparison to reference samples. A positive correlation was observed in southern toads between Sr concentrations and trophic position, as assessed by nitrogen stable isotope ratios, suggesting potential for biomagnification of Sr within our study system. Collectively, our results demonstrate that legacy contaminants are still present and bioaccumulate in a diversity of taxa in a CCR-contaminated site that has not received effluents in more than 50 years, suggesting monitoring programs in CCR-contaminated sites should be maintained long term in the absence of remediation.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Correcting correlation functions for redshift-dependent interloper contamination

ABSTRACT The construction of catalogues of a particular type of galaxy can be complicated by interlopers contaminating the sample. In spectroscopic galaxy surveys this can be due to the misclassification of an emission line; for example in the Hobby–Eberly Telescope Dark Energy Experiment (HETDEX) low-redshift [O ii] emitters may make up a few per cent of the observed Ly α emitter (LAE) sample. The presence of contaminants affects the measured correlation functions and power spectra. Previous attempts to deal with this using the cross-correlation function have assumed sources at a fixed redshift, or not modelled evolution within the adopted redshift bins. However, in spectroscopic surveys like HETDEX, where the contamination fraction is likely to be redshift dependent, the observed clustering of misclassified sources will appear to evolve strongly due to projection effects, even if their true clustering does not. We present a practical method for accounting for the presence of contaminants with redshift-dependent contamination fractions and projected clustering. We show using mock catalogues that our method, unlike existing approaches, yields unbiased clustering measurements from the upcoming HETDEX survey in scenarios with redshift-dependent contamination fractions within the redshift bins used. We show our method returns autocorrelation functions with systematic biases much smaller than the statistical noise for samples with at least as high as 7 per cent contamination. We also present and test a method for fitting for the redshift-dependent interloper fraction using the LAE–[O ii] galaxy cross-correlation function, which gives less biased results than assuming a single interloper fraction for the whole sample.

79 ASTRONOMY AND ASTROPHYSICS↗

Performance Losses and Current-Driven Recovery from Cation Contaminants in PEM Water Electrolysis

Water contaminants are a common cause of failure for polymer electrolyte membrane (PEM) electrolyzers in the field as well as a confounding factor in research on cell performance and durability. In this study, we investigated the performance impacts of feed water containing representative tap water cations at concentrations ranging from 0.5–500 μ M, with conductivities spanning from ASTM Type II to tap-water levels. We present multiple diagnostic signatures to help identify the presence of contaminants in PEM electrolysis cells. Through analysis of polarization curves and impedance spectroscopy to understand the origins of performance losses, we found that a switch from the acidic to alkaline hydrogen evolution mechanism is a key factor in contaminated cell behavior. Finally, we demonstrated that this mechanism switching can be harnessed to remove cation contaminants and recover cell performance without the use of an acid wash. We demonstrated near-complete recovery of cells contaminated with sodium and calcium, and partial recovery of a cell contaminated with iron, which was further investigated by post-mortem microscopy. The improved understanding of contaminant impacts from this work can inform development of strategies to mitigate or recover performance losses as well as improve the consistency and rigor of electrolysis research.

30 DIRECT ENERGY CONVERSION↗

A Murine Model of Radionuclide Lung Contamination for the Evaluation of Americium Decorporation Treatments

The hydroxypyridinone ligand 3,4,3-LI(1,2-HOPO) (HOPO), has been previously characterized as a promising chelating agent for in vivo decorporation of actinides, with decorporation being the removal of internally deposited contaminants from the body after exposure. The large majority of relevant literature reports have detailed the efficacy profile of HOPO as a decorporation agent in rodent models, where controlled radionuclide contamination is conducted via intravenous injection. However, this method of contamination does not necessarily reflect an accurate predictive model of the most probable biodistribution of free metal in the body. In the event of a radiological dispersal device or nuclear power plant accident scenario, it is most likely that first responders, military personnel, and victims of the event will be contaminated via air and water transmission. Therefore, research into the efficacy of chelating agents to treat lung-contaminated in vivo models needs to be carried out. Here, we establish a murine model with controlled, reproducible lung contamination using two different radionuclides, 89Zr and 241Am, for orthogonal biodistribution validation by positron emission tomography and ex vivo radioanalysis, respectively. In addition, we report effective chelation treatment of 241Am-contaminated lungs using HOPO, which improves decorporation by up to 40% compared to Ca-DTPA, the current standard of care.

Arino, Trevor↗

Removable, Sequestration Coatings for Mitigating Hazardous Contaminants Related to Deactivation and Decommissioning Activities

This project is a collaborative effort between InnoSense LLC (ISL) and Oak Ridge National Laboratory (ORNL) aimed at mitigating the mercury (Hg) contamination problem at the Y-12 National Security Complex (NSC). The report summarizes the research and technology development work of the Phase IIB Project, led by Dr. Uma Sampathkumaran at ISL for the period of July 31, 2017–October 31, 2021. The Y-12 site cleanup includes technologies for safe and cost-effective facility demolition, soil remediation, and on-site treatment and disposal of mercury bearing wastes. One of the technology demonstration goals was a reactive strippable coating for targeted pre-demolition and de-contamination to limit Hg mobilization and the volume of debris requiring treatment for disposal. Toward this, ISL has developed a water-based reactive strippable coating (Trap & See-Hg™) to sequester elemental Hg(0) and mercuric Hg(II) species in the coating. The coating provides multiple benefits including (1) Hg vapor suppression, (2) sealing in the hazardous contaminants, (3) visually locating the contaminant through color changes, and (4) remediating the contaminated surfaces upon coating removal. Through collaboration between ORNL and ISL in Phase II work, the team successfully demonstrated the Trap & See-Hg technology to (1) visually locate the presence of Hg on concrete, soil and drywall surfaces, (2) effectively sequester all mercury species (elemental, soluble and insoluble Hg) from lab-generated and ex-situ soil and brick/rubble samples collected from the Y 12 site with 80 to 95% efficiency to capture/reduce Hg vapor concentration, (3) be applied by manual and robotic spray applicators and cure at room ambient, (4) remain a cohesive and peelable coating upon drying, and (5) sequester Hg0 from walls in the alpha-2 building basement at Y-12 during a small scale in-situ field trial. In Phase IIB, ISL’s effort was focused on refining the coating formulations with additives containing passive and reactive sorbents, colorimetric indicator, and thixotropic agents to achieve the desired performance. The paints were then evaluated at ORNL for applicability to metal and concrete surfaces of different sizes and shapes, and soil rubble, Hg-sorption capacity and achieving sag-free coating on surfaces when applied by a manual spray applicator. Ambient cure of the coating resulted in a dry thickness of 16–20 mil. The coatings were removed from smooth or rough surfaces with low to moderate force. Both lab-generated Hg-contaminated samples and soil and brick/rubble samples containing a range of Hg concentrations (collected from the Y-12 site by UCOR) were used in this project. Optimized formulations were applied to these samples and evaluated for ability to suppress Hg vapors, sequester Hg 0 and Hg(II) species and color mapping of mercury species on the test surface. The ORNL team initially identified three to four potential sites at Y-12 and ORNL for potential demonstration. However, the pandemic closed any possible avenues for on-site demonstration of the robotic spray applicator. The metal and concrete samples with low to high Hg content provided by UCOR from an ongoing demolition were subsequently used for ex-situ sample characterization and analysis at ORNL over a period of 25 days. The coatings suppressed Hg vapors with an efficiency of 95–99% from heavily contaminated metal and 60% from concrete substrate. Analysis of total Hg in the peeled paints indicates sorption capacities ranging from 12 µg Hg/g of paint from concrete to 1.2 mg Hg/g of paint from the metal substrates while peeled paints from soil samples could capture a total Hg from 2.3 mg Hg/g to 66 mg/g paint. Toxicity characteristic leaching procedure (TCLP) tests recovered total mercury leached at 0.15±0.0008 µg/L for concrete to 126.81±0.67 µg/L and 377.25±5.67 µg/L for the two metal substrates, to allow for informed decisions on downstream disposal considerations. Together, this Phase IIB demonstrated the potential value of the Trap & See-Hg for Hg uptake, vapor suppression, and color mapping, and may thus be used to enhance worker safety during site cleanup, facility demolition, and downstream waste disposal at Y-12 NSC.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Non-reactive facet specific adsorption as a route to remediation of chlorinated organic contaminants

The present work quantifies metal-contaminant interactions between palladium substrates and three salient chlorinated organic contaminants, namely trichloroethylene 1,3,5-trichlorobenzene (TCB), and 3,3′,4,4′-tetrachlorobiphenyl (PCB77). Given that Pd is one of the conventional catalytically active materials known for contaminant removal, maximizing catalytic efficiency through optimal adsorption dynamics reduces the cost of remediation of contaminants that are persistent water pollutants chronically affecting public health. Adsorption efficiency analyses from all-atom molecular dynamics (MD) simulations advance the understanding of reaction mechanisms available from density functional theory (DFT) calculations to an extractable feature scale that can fit the parametric design of supported metal catalytic systems and feed into high throughput catalyst selection. Data on residence time, site-specific adsorption, binding energies, packing geometries, orientation profiles, and the effect of adsorbate size show the anomalous behaviour of organic contaminant adsorption on the undercoordinated {110} surface as compared to the {111} and {100} surfaces. The intermolecular interaction within contaminants from molecular dynamics simulation exhibits refreshing results than ordinary single molecule density functional theory calculation. Since complete adsorption and dechlorination is an essential step for chlorinated organic contaminant remediation pathways, the presented profiles provide essential information for designing efficient remediation systems through facet-controlled palladium nanoparticles.

Guo, Hao↗

Automated identification of local contamination in remote atmospheric composition time series

Abstract. Atmospheric observations in remote locations offer a possibility of exploring trace gas and particle concentrations in pristine environments. However, data from remote areas are often contaminated by pollution from local sources. Detecting this contamination is thus a central and frequently encountered issue. Consequently, many different methods exist today to identify local contamination in atmospheric composition measurement time series, but no single method has been widely accepted. In this study, we present a new method to identify primary pollution in remote atmospheric datasets, e.g., from ship campaigns or stations with a low background signal compared to the contaminated signal. The pollution detection algorithm (PDA) identifies and flags periods of polluted data in five steps. The first and most important step identifies polluted periods based on the derivative (time derivative) of a concentration over time. If this derivative exceeds a given threshold, data are flagged as polluted. Further pollution identification steps are a simple concentration threshold filter, a neighboring points filter (optional), a median, and a sparse data filter (optional). The PDA only relies on the target dataset itself and is independent of ancillary datasets such as meteorological variables. All parameters of each step are adjustable so that the PDA can be “tuned” to be more or less stringent (e.g., flag more or fewer data points as contaminated). The PDA was developed and tested with a particle number concentration dataset collected during the Multidisciplinary drifting Observatory for the Study of Arctic Climate (MOSAiC) expedition in the central Arctic. Using strict settings, we identified 62 % of the data as influenced by local contamination. Using a second independent particle number concentration dataset also collected during MOSAiC, we evaluated the performance of the PDA against the same dataset cleaned by visual inspection. The two methods agreed in 94 % of the cases. Additionally, the PDA was successfully applied to a trace gas dataset (CO2), also collected during MOSAiC, and to another particle number concentration dataset, collected at the high-altitude background station Jungfraujoch, Switzerland. Thus, the PDA proves to be a useful and flexible tool to identify periods affected by local contamination in atmospheric composition datasets without the need for ancillary measurements. It is best applied to data representing primary pollution. The user-friendly and open-access code enables reproducible application to a wide suite of different datasets. It is available at https://doi.org/10.5281/zenodo.5761101 (Beck et al., 2021).

54 ENVIRONMENTAL SCIENCES↗

Optimized purification methods for metallic contaminant removal from directly recycled Li-ion battery cathodes

Metallic contaminants pose a significant challenge to the viability of directly recycling Li-ion batteries. To date, few strategies exist to selectively remove metallic impurities from mixtures of shredded end-of-life material (black mass; BM) without concurrently damaging the structure and electrochemical performance of the target active material. We herein present tailored methods to selectively ionize two major contaminants—Al and Cu—while retaining a representative cathode (LiNi 0.33 Mn 0.33 Co 0.33 O 2 ; NMC-111) intact. This BM purification process is conducted at moderate temperatures in a KOH-based solution matrix. We rationally evaluate approaches to increase both the kinetic corrosion rate and the thermodynamic solubility of Al 0 and Cu 0 , and evaluate the impact of these treatment conditions on the structure, chemistry, and electrochemical performance of NMC. Specifically, we explore the impacts of chloride-based salts, a strong chelating agent, elevated temperature, and sonication on the rate and extent of contaminant corrosion, while concurrently evaluating the effects on NMC. The reported BM purification process is then demonstrated on samples of “simulated BM” containing a practically relevant 1 wt% concentration of Al or Cu. Increasing the kinetic energy of the purifying solution matrix through elevated temperature and sonication accelerates the corrosion of metallic Al and Cu, such that ∼100% corrosion of 75 μm Al and Cu particles is achieved within 2.5 hr. Further, we determine that effective mass transport of ionized species critically impacts the efficacy of Cu corrosion, and that saturated Cl – hinders rather than accelerates Cu corrosion by increasing solution viscosity and introducing competitive pathways for Cu surface passivation. The purification conditions do not induce bulk structural damage to NMC, and electrochemical capacity is maintained in half-cell format. Testing in full cells suggests that a limited quantity of residual surface species are present after treatment, which initially disrupt electrochemical behavior at the graphite anode but are subsequently consumed. Process demonstration on simulated BM suggests that contaminated samples—which prior to treatment show catastrophic electrochemical performance—can be recovered to pristine electrochemical capacity. The reported BM purification method offers a compelling and commercially viable solution to address contamination, particularly in the “fine” fraction of BM where contaminant sizes are on the same order of magnitude as NMC and where traditional separation approaches are unfeasible. Thus, this optimized BM purification technique offers a pathway towards viable direct recycling of BM feedstocks that would otherwise be unusable.

25 ENERGY STORAGE↗

Water reactive polyurethane grouting for deep vadose zone contaminant immobilization

Contaminants in the deep vadose zone (DVZ) pose a long-term threat to groundwater, human health, and the environment. Polyurethane grouting is a type of chemical grouting that is potentially advantageous in immobilizing contaminants in DVZs. Polyurethane resin has low viscosity that makes it feasible to penetrate and fill the pore space between fine particles. Here, in this study a series of laboratory pressure grouting and leaching tests were conducted to simulate and assess the effectiveness of polyurethane grouting for immobilizing contaminants in DVZs. Soil with fine particles was prepared with 127 I (as iodide) that served as a non-radioactive surrogate for radioactive 129 I. After grouting and curing, leaching tests were used to measure and compare contaminant diffusivity and leachability index values. Additionally, changes in porosity and saturated hydraulic conductivity of grouted soil were measured. X-Ray Computer Tomography (XCT) results showed that the cured polyurethane was distributed nearly homogeneously and approximately half of the voids were filled with cured polyurethane. Grouting reduced the saturated hydraulic conductivity of soil by 37 %. The effective diffusivity decreased by more than 80 % as compared with the ungrouted soil. The leachability index of the grouted soil was 6.5; meeting the criteria established by the U.S. Nuclear Regulatory Commission (NRC) standard. The results obtained in this study provide a valuable assessment of polyurethane grouting for iodide immobilization in the DVZ and indicate this approach may be a viable method for contaminant remediation in DVZ soils.

Contaminant Diffusion↗

Using radioactive material to evaluate decontamination of contaminated electronics

Electronic materials are used everywhere and can get easily contaminated by their use in the field/laboratory. The goal of this project was to use radioactive material to track the effectiveness of a cleaning procedure using an off-the-shelf cleaning gel. Radioactive potassium bromide (KBr) was used as a model contaminant in four contamination scenarios to gauge the effectiveness of a cleaning gel in the decontamination of contaminated raspberry pi’s. Finally, the investigated decontamination technique was found to be 75–97% effective in removing contamination from the tested electronic devices. 95% of the contaminated electronic devices retained their functionality post-decontamination.

38 - RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCL↗

Environmental fate of radiocesium in biota inhabiting a contaminated ecosystem on the U.S. Department of Energy's Savannah River Site

Although biomagnification of radiocesium ( 137 Cs) has been reported in food webs, most previous research has been limited to select trophic linkages. Few studies have included a comprehensive survey of fauna associated with aquatic, semi-aquatic, and terrestrial habitats within a single study framework. The objectives of this study were to advance our understanding of the dynamics of 137 Cs accumulation within food webs by quantifying 137 Cs activity across a wide range of biota found within a contaminated canal, as well as test the hypothesis that life-stage and body size influence 137 Cs bioaccumulation in select herpetofauna. With extensive sampling across multiple taxa collected from a contaminated canal system and associated floodplain on the Savannah River Site, we assessed 137 Cs activity and stable nitrogen isotopes for both aquatic organisms that were restricted to the contaminated effluent canal, and semi-aquatic organisms able to move freely between the contaminated canal and the adjacent uncontaminated terrestrial habitat. We found 137 Cs activity to be highly variable among species, with evidence for and against biomagnification in semi-aquatic and aquatic organisms, respectively. Furthermore, 137 Cs activity decreased with life stage and body size in bullfrogs (Lithobates catesbeianus), despite post-metamorphic bullfrogs having a more carnivorous diet compared to tadpoles, while cottonmouths (Agkistrodon piscivorus) retained similar 137 Cs activity regardless of their age and size. While evidence of biomagnification has been observed in some contaminated systems, results of our study suggest the extent to which 137 Cs biomagnifies within food webs is context-dependent and likely influenced by a suite of biotic and abiotic factors. Further, our data indicate sampling of a broad suite of species and environmental attributes are needed to elucidate the fate and dynamics of anthropogenic pollutants within contaminated ecosystems.

54 ENVIRONMENTAL SCIENCES↗

ContScout: sensitive detection and removal of contamination from annotated genomes

Contamination of genomes is an increasingly recognized problem affecting several downstream applications, from comparative evolutionary genomics to metagenomics. Here we introduce ContScout, a precise tool for eliminating foreign sequences from annotated genomes. It achieves high specificity and sensitivity on synthetic benchmark data even when the contaminant is a closely related species, outperforms competing tools, and can distinguish horizontal gene transfer from contamination. A screen of 844 eukaryotic genomes for contamination identified bacteria as the most common source, followed by fungi and plants. Furthermore, we show that contaminants in ancestral genome reconstructions lead to erroneous early origins of genes and inflate gene loss rates, leading to a false notion of complex ancestral genomes. Taken together, we offer here a tool for sensitive removal of foreign proteins, identify and remove contaminants from diverse eukaryotic genomes and evaluate their impact on phylogenomic analyses.

59 BASIC BIOLOGICAL SCIENCES↗

Modeled sensitivity of multi-MA accelerator performance to electrode contaminant inventory

Significant particle-in-cell code development has enabled simulations of power flow in multi-MA accelerators to include the desorption of surface contaminants, their ionization into surface plasmas, and the impact of these plasmas on efficiency. The simulations base desorption on an Arrhenius equation, whose most significant unknown is the surface contaminant inventory. The sensitivity of power-flow simulations to this inventory is studied here using Sandia National Laboratories' Z accelerator with a 7-nH MagLIF load [Phys. Plasmas 17, 056303 (2010)]. Simulations are conducted in 3D cylindrical coordinates for the current-adder, or “convolute,” region of Z and in 2D for the final feed only. Simulated contaminant inventories are varied from 1 to 32 monolayers (MLs) in 2D, and 2 to 4 ML in 3D. The results reveal sensitivities to the local ratio of E/B⁠. The high B-field, low E-field region near the short-circuit load is insensitive to the contaminant inventory, where assumed values of 4–32 ML change the load current by ≤ 2%, and agree with experiment to within 2% at peak current. A 1-ML value is the outlier, increasing the load current by 5%, but still within measurement uncertainty. In contrast, the relatively higher E-field, lower B-field convolute region has slower contaminant desorption and higher-magnitude E-field penetration of the surface plasmas. The current loss in the convolute region does increase with contaminant inventory. The loss assuming 4 ML is 12% larger than for 2 ML, with 4 ML being the better match to experiment.

Arrhenius equation↗

Measurable radiation levels around individuals externally contaminated by nuclear fallout

During the early response to large-scale radioactive contamination events, people who are potentially affected need to be screened for radioactive contamination and public health staff need to triage individuals who may need immediate decontamination. This is typically done by screening individuals for external contamination using ionising radiation detection equipment. In this study, spatially and temporally dependent isotopic compositions from a simulated nuclear detonation and Monte Carlo methods were used to relate contamination activity levels to the measurable radiation levels at select distances away from an individual with whole-body contamination. Radionuclide-specific air kerma rate coefficients and Geiger–Mueller instrument response coefficients at five select distances from contaminated individuals are presented for 662 radionuclides. Temporally and spatially dependent incident-specific coefficients are presented for a hypothetical surface detonation of a 235 U-fueled device.

61 RADIATION PROTECTION AND DOSIMETRY↗

Flue-Gas Desulfurization Effluent Management using an Innovative Low-Energy Biosorpotion Treatment System to Remove Key Contaminants

Among the most critical water contaminants of concern affecting wide geographical regions and a number of industries and natural systems is selenium. Selenium found in surface, ground and wastewater in originates from natural sources, as well as industrial sources such as petroleum refineries, electronics manufacturing, pesticides, and coal power plants and mining also contribute to selenium contamination in water in the US. At high concentrations, selenium is toxic to human and wildlife. There are a number of technologies that have been used to treat selenium and other similar contaminants in water. Biological treatment of selenium has been used in the past to reduce soluble SeVI and/or SeIV to insoluble Se0, which is then filtered in the same vessel. The insoluble selenium (Se0) is then backwashed from the system and solids are separated for subsequent disposal, if they meet the leaching and water content criteria. In order to promote biological reduction to insoluble Se0, heating of bioreactor is needed in some applications, and excess food source (electron donor) is added so that all selenium can be filtered. An additional disadvantage of these systems is the significant amount of water lost due to extensive and frequent backwash and rinse cycles. When comparing the advantages and energy requirements of the various treatment technologies, RO membrane filtration immediately stands out due to the excessive energy expenditure needed to pump water across the membrane although RO is an effective way to remove selenium. In addition, RO requires extensive pretreatment, such as MF membrane, and frequent maintenance, rendering it an expensive option that may be out of reach for certain applications. In fact, although the performance was good during the pilot testing by the NSMP Working Group for treatment naturally occurring selenium in the surface water, the high electricity requirements and significant reject water stream made it an infeasible alternative. While conventional ion exchange maybe an effective treatment option, it requires frequent regeneration of the resin when applied to highly contaminated water, which leads to several tons of contaminant-laden, high-salinity brine that needs to be disposed off-site each day. One of the water systems in the west coast currently uses ion exchange for selenium treatment and has been trucking selenium laden hazardous brine waste weekly in the last several years. Pneumatic pumping and rinse water pumping required for ion exchange also increase the energy usage. In comparison, adsorption process is a passive treatment system where contaminated water comes in contact with an adsorption media in a vessel. Typically, there is no mixing, backwash, or recycle pumping required, thus significantly reducing the energy usage. A passive single-use adsorption system does not require backwash, thereby generating small amount of process waste, and producing the highest water yield among the alternatives. The energy and water efficiencies, and applicability for SeVI and SeIV are summarized in Table 1. Despite these benefits though, adsorption typically does not work for the most oxidized form of selenium (SeVI). The innovative biosorption process integrates both process to increase the treatment efficiency while minimizing energy, chemical, and time required to treat both SeVI and SeIV. Additional advantages include simple partial biological reduction with reduced on-site waste generation, which lead to water and electricity savings, and less operational need compared to biological treatment alone. This makes biosorption especially suitable for remote areas, where liquid backwash and brine disposal may be cost prohibitive or infeasible.

20 FOSSIL-FUELED POWER PLANTS↗

Core-collapse contamination in photometric samples of Type Ia Supernovae

This is an exciting time for cosmology with type Ia supernovae (SNe Ia). The recentlyconcluded Dark Energy Survey SN programme (DES-SN) has obtained the largest anddeepest high-redshift cosmological SN Ia sample, and the Vera Rubin Observatory isexpected to observe at least one order of magnitude more SNe Ia in the next decade.In both these experiments, only a limited fraction (.10 per cent) of the SNe can bespectroscopically classified. This leaves us with large ‘photometric’ SN samples, withthe potential for significant contamination by core-collapse SNe that may bias SN Iacosmological measurements. This thesis demonstrates how this contamination can bemodelled and accounted for in current and future cosmological analyses.First, I present state-of-the-art simulations of the SN universe. These are designedto accurately model the population of SNe Ia, peculiar SNe Ia and core-collapse SNe, aswell as their host galaxies. To improve the diversity and quality of the simulated corecollapseSNe, I build a new library of core-collapse SN templates using spectroscopicand photometric (optical and near-ultraviolet) data of 67 core-collapse SNe from theliterature. I account for our incomplete knowledge of core-collapse SN properties bygenerating a set of SN simulations (rather than a single one), each exploring differentmodelling choices and template libraries. I then characterise selection effects in theDES-SN survey and incorporate them in the simulations, thus obtaining a series ofDES-like simulated SN samples that can be compared to the observed DES-SN data.The agreement between the simulations and data is excellent across many observed SNproperties, including Hubble residuals. These simulations are the first to reproduce theobserved photometric SN and host galaxy properties in high-redshift surveys with no fine-tuning of the input parameters.I use my simulation framework to train and test the performance of SuperNNova,a photometric SN classifier based on recurrent neural networks. I explore differenttraining and validation strategies and show that, across all the DES-SN simulationstested, SuperNNova reduces core-collapse SN contamination to 0.8–3.5 per cent. Ithen show that biases due to contamination on the equation-of-state of dark energy,w, are < 0:008 when using our reference SuperNNova model. This compares to anexpected statistical uncertainty on w from the DES-SN sample of 0:039, thus showing that contamination is not a limiting systematic for the cosmological analysis of theDES-SN sample.The results presented in this thesis are the foundation of the DES SN Ia cosmologicalanalysis; they also provide important implications for the future of SN cosmology,as they demonstrate that contamination is not expected to significantly degrade thecosmological figure of merit of the Rubin SN Ia analysis.

79 ASTRONOMY AND ASTROPHYSICS↗