Search NASA⌕ Search

SEARCH · Search NASA

Results for “Contrast”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Improvement of the photometric sunspot index and changes of the disk-integrated sunspot contrast with time

The photometric sunspot index (PSI) was developed to study the effects of sunspots on solar irradiance. It is calculated from the sunspot data published in the Solar-Geophysical Data catalog. It has been shown that the former PSI models overestimate the effect of dark sunspots on solar irradiance; furthermore results of direct sunspot photometry indicate that the contrast of spots depends on their area. An improved PSI calculation is presented; it takes into account the area dependence of the contrast and calculates `true' daily means for each observation using the differential rotation of the spots. Moreover, the observations are screened for outliers which improves the homogeneity of the data set substantially, at least for the period after December 1981 when NOAA started to report data from a few instead of one to two stations. A detailed description of the method is provided. The correlation between the newly calculated PSI and total solar irradiance is studied for different phases of the solar cycles 21 and 22 using bi-variate spectral analysis. The results can be used as a `calibration' of PSI in terms of gain, the factor by which PSI has to be multiplied to yield the observed irradiance change. The factor changes with time from about 0.6 in 1980 to 1.1 in 1990. This unexpected result cannot be interpreted by a change of the contrast relative to the quiet Sun (as it is normally defined and determined by direct photometry) but rather as a change of the contrast between the spots and their surrounding as seen in total irradiance (integrated over the solar disk). This may partly be explained by a change in the ratio between the areas of the spots and the surrounding faculae.

Froehlich, Claus↗

Closed Loop, DM Diversity-based, Wavefront Correction Algorithm for High Contrast Imaging Systems

High contrast imaging from space relies on coronagraphs to limit diffraction and a wavefront control systems to compensate for imperfections in both the telescope optics and the coronagraph. The extreme contrast required (up to 10(exp -10) for terrestrial planets) puts severe requirements on the wavefront control system, as the achievable contrast is limited by the quality of the wavefront. This paper presents a general closed loop correction algorithm for high contrast imaging coronagraphs by minimizing the energy in a predefined region in the image where terrestrial planets could be found. The estimation part of the algorithm reconstructs the complex field in the image plane using phase diversity caused by the deformable mirror. This method has been shown to achieve faster and better correction than classical speckle nulling.

Give'on, Amir↗

The Incidence of Patent Foramen Ovale in 1,000 Consecutive Patients: A Contrast Transesophageal Echocardiography Study

Study objective: Patent foramen ovale (PFO) is present in 10 to 35% of people and has been reported to be an important risk factor for cardioembolic cerebrovascular accidents (CVAs) and transient ischemic attacks (TIAS), especially in younger patients. While contrast transthoracic echocardiography has been used to detect PFO, contrast transesophageal echocardiography (TEE) has a greater sensitivity. Prior studies reported the incidence of PFO in patients presenting with a CVA or TIA. Design: To determine the incidence of PFO in a more general population, we reviewed 1,000 consecutive TEES performed with contrast and color Doppler for the presence of PFO and other cardioembolic risk factors, including atrial septal aneurysm (ASA), aortic plaque, atrial fibrillation (AFib), and atrial thrombi. While imaging with monoplane or biplane TEE, multiple injections of agitated saline solution were injected during cough or Valsalva maneuver to detect flow through a PFO. Patients: There were 482 male and 518 female patients with mean age of 60 + 17 years (range 11 to 93 years). Results: Patent foramen ovale was found in 9.2% of all patients and, though seen in all age groups divided by decade, the incidence in patients aged 40 to 49 years was greater than those aged 70 to 79 years (12.96% vs 6.15%',, p=0.03). Contrast TEE had a much higher detection rate than color Doppler alone. Importantly, there was no greater incidence of PFO in patients with CVA vs thos~ without CVA, or in male vs female patients. Also, there was a very strong correlation between the presence of ASA and PFO (p<.001). Conclusion: Thus, PFO detected by TEE, frequently seen with ASA, is seen in all age groups and does not in itself present a risk factor for CVA. The association of PFO with peripheral thrombosis and CVA needs further study.

Fisher, Daniel C.↗

Model of visual contrast gain control and pattern masking

We have implemented a model of contrast gain and control in human vision that incorporates a number of key features, including a contrast sensitivity function, multiple oriented bandpass channels, accelerating nonlinearities, and a devisive inhibitory gain control pool. The parameters of this model have been optimized through a fit to the recent data that describe masking of a Gabor function by cosine and Gabor masks [J. M. Foley, "Human luminance pattern mechanisms: masking experiments require a new model," J. Opt. Soc. Am. A 11, 1710 (1994)]. The model achieves a good fit to the data. We also demonstrate how the concept of recruitment may accommodate a variant of this model in which excitatory and inhibitory paths have a common accelerating nonlinearity, but which include multiple channels tuned to different levels of contrast.

NASA Discipline Space Human Factors↗

Broadband Performance of TPF's High-contrast Imaging Testbed: Modeling and Simulations

The broadband performance of the high-contrast imaging testbed (HCIT) at JPL is investigated through optical modeling and simulations. The analytical tool is an optical simulation algorithm developed by combining the HCIT's optical model with a speckle-nulling algorithm that operates directly on coronagraphic images, an algorithm identical to the one currently being used on the HCIT to actively suppress scattered light via a deformable mirror. It is capable of performing full three-dimensional end-to-end near-field diffraction analysis on the HCIT's optical system. By conducting speckle-nulling optimization, we clarify the HCIT's capability and limitations in terms of its broadband contrast performance under various realistic conditions. Considered cases include non-ideal occulting masks, such as a mask with optical density and wavelength dependent parasitic phase-delay errors (i.e., a not band-limited occulting mask) and the one with an optical-density profile corresponding to a measured, non-standard profile, as well as the independently measured phase errors of all optics. Most of the information gathered on the HCIT's optical components through measurement and characterization over the last several years at JPL has been used in this analysis to make the predictions as accurate as possible. The best contrast values predicted so far by our simulations obtainable on the HCIT illuminated with a broadband light having a bandwidth of 80nm and centered at 800nm wavelength are Cm=1.1x10-8 (mean) and C4=4.9x10-8 (at 4(lamda)/D), respectively. In this paper we report our preliminary findings about the broadband light performance of the HCIT.

integrated modeling↗

High Contrast Imaging with the JWST NIRCAM Coronagraph

Relative to ground-based telescopes, the James Webb Space Telescope (JWST) will have a substantial sensitivity advantage in the 2.2-5pm wavelength range where brown dwarfs and hot Jupiters are thought to have significant brightness enhancements. To facilitate high contrast imaging within this band, the Near-Infrared Camera (NIRCAM) will employ a Lyot coronagraph with an array of band-limited image-plane occulting spots. In this paper, we provide the science motivation for high contrast imaging with NIRCAM, comparing its expected performance to that of the Keck, Gemini and 30 m (TMT) telescopes equipped with Adaptive Optics systems of different capabilities. We then describe our design for the NIRCAM coronagraph that enables imaging over the entire sensitivity range of the instrument while providing significant operational flexibility. We describe the various design tradeoffs that were made in consideration of alignment and aberration sensitivities and present contrast performance in the presence of JWST's expected optical aberrations. Finally we show an example of a that can provide 10-5 companion sensitivity at sub-arcsecond separations.

coronagraph↗

Pair-Wise, Deformable Mirror, Image Plane-Based Diversity Electric Field Estimation for High Contrast Coronagraphy

In this paper we describe the complex electric field reconstruction from image plane intensity measurements for high contrast coronagraphic imaging. A deformable mirror (DM) surface is modied with pairs of complementary shapes to create diversity in the image plane of the science camera where the intensity of the light is measured. Along with the Electric Field Conjugation correction algorithm, this estimation method has been used in various high contrast imaging testbeds to achieve the best contrasts to date both in narrow and in broad band light. We present the basic methodology of estimation in easy to follow list of steps, present results from HCIT and raise several open quations we are confronted with using this method.

coronagraphy↗

Demonstration of on Sky Contrast Improvement Using the Modified Gerchberg-Saxton Algorithm at the Palomar Observatory

We have successfully demonstrated significant improvements in the high contrast detection limit of the Well-Corrected Subaperture (WCS) using the Autonomous Phase Retrieval Calibration (APRC) software package developed at the Jet Propulsion Laboratory (JPL) for the Palomar adaptive optics instrument (PALAO). APRC utilizes the Modified Gerchberg-Saxton (MGS) wavefront sensing algorithm, also developed at JPL. The WCS delivers such excellent correction of the atmosphere that non-common path (NCP) wavefront errors not sensed by PALAO but present at the coronagraphic image plane begin to factor heavily as a limit to contrast. We have implemented the APRC program to reduce these NCP wavefront errors from 110 nm to 35 nm (rms) in the lab, and we have extended these exceptional results to targets on the sky for the first time, leading to a significant suppression of speckle noise. Consequently we now report a contrast level of very nearly 1x10(exp -4) at separations of 2 lambda/D before the data is post processed. We describe here the major components of our instrument, the work done to improve the NCP wavefront errors, and the ensuing excellent on sky results, including the detection of the three exoplanets orbiting the star HR8799.

mgs↗

Demonstration of Broadband Contrast at 1.2 Lambda/D for the EXCEDE Phase-Induced Amplitude Apodization Coronagraph

The proposed coronagraph instrument on the EXCEDE (EXoplanetary Circumstellar Environments and Disk Explorer) mission study uses a Phase-Induced Amplitude Apodization (PIAA) coronagraph architecture to enable high-contrast imaging of circumstellar debris disks and giant planets at angular separations as close in as the habitable zone of nearby host stars. We report on the experimental results obtained in the vacuum chamber at the Lockheed Martin Advanced Technology Center in 10 percent broadband light centered about 650 nanometers, with a median contrast of 1 x 10 (sup -5) between 1.2 and 2.0 lambda /D simultaneously with 3 x 10 (sup -7) contrast between 2 and 11 =D between 2 and 11 lambda/D for a single-sided dark hole using a deformable mirror (DM) upstream of the PIAA coronagraph. The results are stable and repeatable as demonstrated by three measurements runs with DM settings set from scratch and maintained on the best 90 percent out of the 1000 collected frames. We compare the reduced experimental data with simulation results from modeling observed experimental limits; performance is consistent with uncorrected low-order modes not estimated by the Low Order Wavefront Sensor (LOWFS). Modeled sensitivity to bandwidth and residual tip/tilt modes is well-matched to the experiment.

Wavefront control↗

Studies of the Effects of Control Bandwidth and Dark-Hole Size on the HCIT Contrast Performance

We have carried out both theoretical and experimental studies of the sensitivity of dark hole contrast to the control bandwidth and dark-hole dimensions in high-contrast broadband stellar coronagraphy. We have evaluated the performance of DM actuator solutions in the presence of occulting mask defects using one to five 2% -wide bands spanning a 10% bandpass. We have also investigated the dependence of the HCIT contrast performance on the size of dark -hole area including large dark holes formed at the Nyquist limit of the DM.

exoplanets↗

High-Contrast Coronagraph Performance in the Presence of DM Actuator Defects

Deformable Mirrors (DMs) are critical elements in high contrast coronagraphs, requiring precision and stability measured in picometers to enable detection of Earth-like exoplanets. Occasionally DM actuators or their associated cables or electronics fail, requiring a wavefront control algorithm to compensate for actuators that may be displaced from their neighbors by hundreds of nanometers. We have carried out experiments on our High-Contrast Imaging Testbed (HCIT) to study the impact of failed actuators in partial fulfillment of the Terrestrial Planet Finder Coronagraph optical model validation milestone. We show that the wavefront control algorithm adapts to several broken actuators and maintains dark-hole contrast in broadband light.

adaptive optics↗

Photoreversible Color-Switching Cu-Doped TiO2 Nanoparticles for High-Contrast Rewritable Printing

Light-printable rewritable paper that can be used multiple times has attracted extensive attention because of its potential benefits in reducing environmental pollution and energy consumption. Developing rewritable paper with high black-to-colorless contrast, lasting legibility, and a fast response is fascinating but challenging. Here, we integrate the redox chemistry of Cu2+ ions into photoreductive TiO2 nanoparticles to produce Cu-doped TiO2 nanoparticles capable of highly photoreversible switching between colorless and black with excellent contrast and color stability. Incorporating such nanoparticles into hydroxyethyl cellulose produces a rewritable paper with the same appearance as that of conventional paper. More importantly, it demonstrates great features promising for practical applications, including high black-to-colorless contrast, fast light-printing (<20 s), long legible time (>3 days), high reversibility (>50 cycles), high resolution (90 μm), and large scale (A4 size) applicability.

Wang, Wenshou↗

Temporal contrast degradation from mid-spatial-frequency surface error on stretcher mirrors

Temporal contrast degradation due to mid-spatial-frequency error in chirped-pulse amplification stretcher optics is studied. Third-order cross-correlation measurements reveal a temporal peak that appears when using two different mirrors processed by magnetorheological finishing, despite an improvement in rms roughness compared to a third unprocessed mirror. Simulations based on measured power spectral density show how the actual impact on contrast is different from measurements using a typical bandwidth-limited third-order cross correlator. Furthermore, strategies are proposed to avoid this type of contrast degradation while exploiting computer numerically controlled polishing techniques for enhancement of surface figure and roughness.

47 OTHER INSTRUMENTATION↗

Multi-contrast machine learning improves schistosomiasis diagnostic performance

Schistosomiasis currently affects over 250 million people and remains a public health burden despite ongoing global control efforts. Conventional microscopy is a practical tool for diagnosis and screening ofSchistosoma haematobium, but identification of eggs requires a skilled microscopist. Here we present a machine learning (ML)-based strategy for automated detection ofS. haematobiumthat combines two imaging contrasts, brightfield (BF) and darkfield (DF), to improve diagnostic performance. We collected BF and DF images of urine samples, many of them containingS. haematobiumeggs, during two different field studies in Côte d’Ivoire using a mobile phone-based microscope, the SchistoScope. We then trained separate egg-detection ML models and compared the patient-level performance of BF and DF models alone to combinations of BF and DF models, using annotations from trained microscopists as the gold standard. We found that models trained on DF images, and almost all BF and DF combinations, performed significantly better than models trained on BF images only. When models were trained on images from the first field study (n = 349 patients, 748 images of each contrast), patient-level classification performance on patient images from the second study (n = 375 patients, 752 images of each contrast) met the WHO Diagnostic Target Product Profile (TPP) sensitivity and specificity for the monitoring and evaluation use case (sensitivity for all models and combinations was >75% when evaluated at a confidence score threshold that resulted in specificity >96.5%). When we used images from both field studies for the training set, performance of the models was improved. Overall, this work shows that the use of DF and BF increases the performance of ML models on images from devices with low-cost optics, while retaining the portability, power, and time-to-results of the WHO’s diagnostic TPP. DF requires no additional sample preparation and does not increase the complexity of the imaging system. It thus offers a practical means to improve performance of automated diagnostics forS. haematobiumas well as other microscopy-based diagnostics.

Infectious Diseases↗

Contrast Matching Biopolymers: A SANS-Based Approach to Structural Characterization of Chitosan

Immobilizing enzymes in polysaccharide-based matrices has been shown to improve both their stability and their catalytic efficiency. Among available materials, chitosan was selected for its abundance, biocompatibility, and versatility in a range of applications. While the broader aim of this work is to study chitosan as a matrix for immobilizing carbonic anhydrase (CA) for CO₂ capture, this study focused on determining the contrast match point (CMP) of hydrogenated and deuterated chitosan in D₂O:H₂O mixtures to enable future structural investigations using small-angle neutron scattering (SANS). Previous work successfully synthesized deuterated chitosan from Rhizopus oryzae mycelia and assessed the degree of deuteration using Fourier-transform infrared spectroscopy (FTIR) and nuclear magnetic resonance (NMR). Building on this foundation, the current study determined the CMPs of both H-chitosan and D-chitosan by performing SANS measurements across a range of D₂O:H₂O solvent contrasts. The extracted CMPs for both forms correlated well with their respective calculated scattering length densities (SLDs), validating the experimental approach. These results establish a critical reference for selective contrast matching in future SANS studies of carbonic anhydrase immobilized in chitosan matrices, enabling detailed structural analysis of enzyme–matrix interactions.

Kosgallana, Chathurika J [ORNL] (ORCID:00000002851↗

High Contrast Pattern Projection To Enable Background Oriented Schlieren Based Air Leak Detection Through Any Interior Or Exterior Building Surface

Air leakage in buildings wastes an estimated 4 quads of energy per year in the United States. Finding and sealing leakage sites is critical in existing buildings. Previous work has shown that background oriented Schlieren (BOS) imaging can be used to visualize air leakage but requires the leak to exit through a high contrast surface like a brick wall. To remedy this, different techniques of projecting various high contrast patterns on low contrast building surfaces like interior gypsum walls or vinyl siding were investigated. For each technique, the background quality was measured and compared to an ideal printed random dot background. The background quality metrics were correlated with the measured visualization metrics to understand which metrics are most important for maximizing air leak visualization performance. In this work, leakage visualization performance is presented for these various projected backgrounds with an aim to expand the building surfaces suitable for the BOS leak detector.

Jatana, Gurneesh [ORNL] (ORCID:0000000288903225)↗

Lunar surface EVA photography of Hadley Rille: Contrast as a constraint

Prior to the Apollo 15 flight, preliminary plans for lunar surface EVA photography of Hadley Rille were examined from the standpoint of expected photographic contrast. Considerable variation in contrast was predicted, resulting in suggestions for specific targets either to be emphasized or ignored at various EVA photo stations. Apollo 15 surface EVA photography appears to have highly satisfactory contrast, generally confirming the predictions. The general technique can be applied to Apollo 16 and 17 photography.

Radin, H. W.↗

Measuring earth-to-space contrast transmittance from ground stations.

Inherent object and background radiance, beam transmittance through the atmosphere, and sky radiance are all measurable from a ground station. It is shown how, in the visible spectrum, the sky radiance and beam transmittance may be used to compute the path radiance for orbital downward paths of sight. Thus, the components for calculating apparent radiance, apparent contrast, and the contrast transmittance from earth to space are measurable from a ground station. Four in-flight experiments were conducted to obtain measurements of contrast transmittance for comparison with measurements made simultaneously at ground stations. The in-flight and ground-based measurements are in good agreement.

Gordon, J. I.↗