Search NASA⌕ Search

SEARCH · Search NASA

Results for “Contrast Sensitivity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Examining Perceptual Luminance Uniformity of Simulated Luminaire Patterns

Luminaire luminance uniformity is an important aspect that can affect perceived lighting quality, discomfort glare, and efficacy. While several metrics have been proposed to characterize luminance uniformity, previous studies have shown that current metrics such as Max:Min or Avg:Min luminance ratios can be insensitive to important differences in luminance gradient that may affect perceived uniformity. In an attempt to resolve this issue, previous studies incorporated a contrast sensitivity function for the human eye based on spatial frequency, such as in the UHVS metric; however, this metric has not been comprehensively studied in relation to perceived uniformity ratings. The study presented in this paper aimed to examine the relationship between the UHVS metric and perceived uniformity ratings. Specifically, the study used a web-based questionnaire that presented simulated luminance patterns and asked participants to assess uniformity using a two-alternative forced-choice procedure. Responses were collected and analyzed from 94 participants. The results showed a significant correlation and relationship between the UHVS metric and perceived uniformity. However, comparisons between patterns that had similar UHVS and between patterns that had larger differences in UHVS did not yield consistent results. These results suggest that the UHVS metric might be used for general guidance but may warrant further studies to better understand its sensitivity and improve its alignment with perceived uniformity ratings.

Abboushi, Belal K.↗

Importance of Contrast-to-Noise Ratio Sensitivity Function in Nondestructive Evaluation

A reliable nondestructive evaluation (NDE) technique provides minimum 90% probability of detection (POD) with 95% confidence for detection of cracklike flaws of a specific size. This requirement comes from fracture control. Fracture control is a risk assessment and control approach for preventing structural failure of fracture critical hardware during its service life. One of the approaches of fracture control is damage tolerance safe life analysis, which assumes that NDE reliably detectable size flaw may exist in the hardware post nondestructive evaluation. Analysis and/or testing are performed to verify that the hardware will not fail during its service life despite existence of such a flaw. NDE methods are conventionally qualified by probability of detection (POD) demonstration testing to ensure reliable flaw detection. Here, a novel and alternative to POD flaw detection reliability approach that uses contrast-to-noise ratio (CNR) is given. The approach uses CNR sensitivity function (SF) and CNR. CNR SF is the minimum CNR needed for reliable flaw detection as a function of certain flaw indication characteristics. Primary difference between POD approaches and CNR flaw detection reliability approach is resolution of flaw detection system. POD approach does not account for the resolution of the system, while CNR approach accounts for the flaw detection resolution. Resolution is determined from the modulation transfer function (MTF) of the flaw detection system. CNR flaw detection reliability approach emphasizes quantitative assessment of “how well each flaw indication is detected”. Therefore, CNR approach is helpful in reducing number of flaws in the sample used in NDE procedure qualification, resulting in cost and time savings. CNR approach is also a case of multi-hit flaw detection analysis which has better flaw detectability size than conventional single-hit flaw detectability. Thus, CNR approach, where applicable, may be superior to conventional POD approach. The paper is an overview of development of CNR modeling, CNR SF modeling and measurement by the author. The paper gives key references to currently used NDE procedure POD qualification approaches including those specific to CNR and CNR SF development in multi-hit flaw detection in NDE. The paper covers core topics in nondestructive evaluation engineering.

Contrast-to-noise ratio↗

Cross-biome synthesis of source versus sink limits to tree growth

Uncertainties surrounding tree carbon allocation to growth are a major limitation to projections of forest carbon sequestration and response to climate change. The prevalence and extent to which carbon assimilation (source) or cambial activity (sink) mediate wood production are fundamentally important and remain elusive. We quantified source-sink relations across biomes by combining eddy-covariance gross primary production with extensive on-site and regional tree ring observations. We found widespread temporal decoupling between carbon assimilation and tree growth, underpinned by contrasting climatic sensitivities of these two processes. Substantial differences in assimilation-growth decoupling between angiosperms and gymnosperms were determined, as well as stronger decoupling with canopy closure, aridity, and decreasing temperatures. Our results reveal pervasive sink control over tree growth that is likely to be increasingly prominent under global climate change.

Science & Technology - Other Topics↗

Separating the Influences of Low-Latitude Warming and Sea Ice Loss on Northern Hemisphere Climate Change

Abstract Analyzing a multimodel ensemble of coupled climate model simulations forced with Arctic sea ice loss using a two-parameter pattern-scaling technique to remove the cross-coupling between low- and high-latitude responses, the sensitivity to high-latitude sea ice loss is isolated and contrasted to the sensitivity to low-latitude warming. Despite some differences in experimental design, the Northern Hemisphere near-surface atmospheric sensitivity to sea ice loss is found to be robust across models in the cold season; however, a larger intermodel spread is found at the surface in boreal summer, and in the free tropospheric circulation. In contrast, the sensitivity to low-latitude warming is most robust in the free troposphere and in the warm season, with more intermodel spread in the surface ocean and surface heat flux over the Northern Hemisphere. The robust signals associated with sea ice loss include upward turbulent and longwave heat fluxes where sea ice is lost, warming and freshening of the Arctic Ocean, warming of the eastern North Pacific Ocean relative to the western North Pacific with upward turbulent heat fluxes in the Kuroshio Extension, and salinification of the shallow shelf seas of the Arctic Ocean alongside freshening in the subpolar North Atlantic Ocean. In contrast, the robust signals associated with low-latitude warming include intensified ocean warming and upward latent heat fluxes near the western boundary currents, freshening of the Pacific Ocean, salinification of the North Atlantic, and downward sensible and longwave fluxes over the ocean.

54 ENVIRONMENTAL SCIENCES↗

Sensitivity of WFIRST Coronagraph Broadband Contrast Performance to DM Actuator Errors

The WFIRST/AFTA 2.4 m space telescope currently under study includes a stellar coronagraph for the imaging and the spectral characterization of extrasolar planets. The coronagraph employs sequential deformable mirrors to compensate for phase and amplitude errors. Using the optical model of an Occulting Mask Coronagraph (OMC) testbed at the Jet Propulsion Laboratory (JPL), we have investigated the sensitivity of a Hybrid Lyot Coronagraph (HLC) broadband contrast performance to DM actuator errors and actuator limits. Considered case include drifts in actuator gains or actuator response curves, paired actuators, as well as the limits imposed by a neighboring-actuator rule. Actual data about the actuator drifts and the knowledge about the paired-actuators obtained in several DM characterization experiments conducted at JPL, as well as the neighboring-actuator rule implemented on the OMC testbed were used in simulations. We obtained good agreement between the model prediction and the testbed measurement in terms of static HLC contrast floor and contrast chromaticity.

Sidick, Erkin↗

Evolution of Geometric Sensitivity Derivatives from Computer Aided Design Models

The generation of design parameter sensitivity derivatives is required for gradient-based optimization. Such sensitivity derivatives are elusive at best when working with geometry defined within the solid modeling context of Computer-Aided Design (CAD) systems. Solid modeling CAD systems are often proprietary and always complex, thereby necessitating ad hoc procedures to infer parameter sensitivity. A new perspective is presented that makes direct use of the hierarchical associativity of CAD features to trace their evolution and thereby track design parameter sensitivity. In contrast to ad hoc methods, this method provides a more concise procedure following the model design intent and determining the sensitivity of CAD geometry directly to its respective defining parameters.

Jones, William T.↗

In-Situ X-Ray Microscopy of Phase and Composition Distributions in Metal Alloys During Solidification

This research applies a state of the art X-ray Transmission Microscope, to image the solidification of metallic or semiconductor alloys in real-time. By employing a hard x-ray source with sub-micron dimensions, resolutions of up to 3 gm can be obtained with magnifications of over 800 X. Specimen growth conditions were optimized and the best imaging technologies applied to maintain x-ray image resolution, contrast and sensitivity. In addition, a special furnace design is required to permit controlled growth conditions and still offer maximum resolution and image contrast. We have successfully imaged in real-time: interfacial morphologies, phase growth, coalescence, incorporation of phases into the growing interface, and the solute boundary layer in the liquid at the solid-liquid inter-face. We have also measured true local growth rates and can evaluate segregation structures in the solid; a form of in-situ metallography. Composition gradients within the specimen cause vafiations in absorption of the flux such that the final image represents a spatial integral of composition (or thickness). During this study, the growth of secondary phase fibers and lameilae from eutectic and monotectic alloys have been imaged during solidification, in real-time, for the first time in bulk metal alloys. Keywords: x-ray, microscope, solidification, microfocus, real-time, microstructure

Kaukler, William F.↗

Robust atom optics for Bragg atom interferometry

Multi-photon Bragg diffraction is a powerful method for fast, coherent momentum transfer of atom waves. However, laser noise, Doppler detunings, and cloud expansion limit its efficiency in large momentum transfer (LMT) pulse sequences. We present simulation studies of robust Bragg pulses developed through numerical quantum optimal control. Optimized pulse performance under noise and cloud inhomogeneities is analyzed and compared to analogous Gaussian and adiabatic rapid passage pulses in simulated LMT Mach–Zehnder interferometry sequences. The optimized pulses maintain robust population transfer and phase response over a broader range of noise, resulting in superior contrast in LMT sequences with thermal atom clouds and intensity inhomogeneities. Large optimized LMT sequences use lower pulse area than Gaussian pulses, making them less susceptible to spontaneous emission loss. The optimized sequences maintain over five times better contrast with tens of momentum separation and offer more improvement with greater LMT. Such pulses could allow operation of Bragg atom interferometers with unprecedented sensitivity, improved contrast, and hotter atom sources.

74 ATOMIC AND MOLECULAR PHYSICS↗

The Role of Nuclear Data Sensitivities in Prompt α-Eigenvalue Predictions of Delayed Critical Benchmarks

Alpha (α) eigenvalues, which describe the logarithmic time derivative of the neutron population in a multiplying system, are integral to time-dependent behavior and diagnostic applications. However, uncertainties in the evaluated nuclear data can significantly impact the accuracy of transport simulations for such quantities. This work explores the use of machine learning models to predict two key outputs, α-eigenvalues and keff bias, using input features derived from α-eigenvalue sensitivities to nuclear data. The criticality safety benchmark models used in this study come from the International Handbook of Evaluated Criticality Safety Benchmark Experiments. Three models, random forest, XGBoost, and NGBoost, are trained on both energy-resolved and energy-summed α sensitivities. For the α-eigenvalue bias prediction, NGBoost achieved the highest R 2 (0.9476) using energy-resolved features, while XGBoost performed best using summed sensitivities. In contrast, when predicting the keff bias, all the models showed moderate predictive capability (best R 2 ≈ 0.72), as the mapping from the static α-sensitivities to the static keff bias was less direct. SHAP (SHapley Additive exPlanations) analysis was used to interpret the model predictions. Across both prediction tasks, the features associated with neutron capture [H-1 (n, γ)], uranium scattering reactions (such as 235 U elastic/inelastic), and actinide capture/fission reactions (such as 239 Pu and 234 U) were consistently identified as the most impactful. This highlights the key role of specific nuclear reactions and energy ranges in shaping both time-dependent and steady-state criticality behavior. These results demonstrated that α-sensitivities, despite being computed for time-dependent metrics, can provide valuable insights for predicting both α-eigenvalues and the keff bias. Moreover, machine learning models offer a promising pathway for uncovering important nuclear data dependencies and guiding future data evaluation efforts.

Nuclear data↗

Evaluation of a Variable-Aperture Full-Ring SPECT System using Large-Area Pixelated CZT Modules: A Simulation Study for Brain SPECT Applications

Single photon emission computed tomography (SPECT) scanner using cadmium zinc telluride (CZT) offers improved imaging capability over conventional NaI (Tl)-based SPECT scanner. We aim to demonstrate a full-ring SPECT system design with eight large-area CZT detectors that can be used for a broad spectrum of SPECT radiopharmaceuticals and provides higher sensitivity and better spatial resolution than those of conventional NaI (Tl)-based gamma cameras. A newly-designed full-ring SPECT system is composed of 8 large-area CZT cameras (128 mm × 179.2 mm effective area) that can be independently swiveled around their own axes of rotation independently and can have radial motion for varying aperture sizes that can be adapted to different sizes of imaging volume. Extended projection data were generated by conjoining projections of two adjacent detectors to overcome the limited field-of-view (FOV) by each CZT camera. Using Monte Carlo simulations, we evaluated this new system design with digital phantoms including a Derenzo hot-rod phantom and a Zubal brain phantom. Comparison of performance metrics such as spatial resolution, sensitivity, contrast-to-noise ratio (CNR), and contrast-recovery ratio were made between our design and a conventional SPECT scanner. The proposed scanner could result in up to about 3 times faster in acquisition time over conventional scan time at same acquisition time per step. The spatial resolution of our proposed scanner was similar or better to that of the conventional scanner, and there was significant performance improvement over the conventional scanner particularly in sensitivity (approximately 4 times). Overall, we successfully reconstructed the phantom image for both 99 mTc-based perfusion and 123 I-based dopamine transporter (DaT) brain studies simulated for our new design. In particular, the striatal/background contrast-recovery ratio in 3-to-1 reference ratio was over the 0.8 for the 123 I-based DaT study. In conclusion, we demonstrated the potential of our new full-ring CZT SPECT design, showing improved performance metrics such as improved system sensitivity and CNR while maintaining other important imaging parameters such as spatial resolution.

36 MATERIALS SCIENCE↗

Sensitivity calibration of a Carestream HPX-1 image plate scanner

There is a need to measure the sensitivity of the image plate scanners used to scan Z shot data. The Carestream HPX-1 image plate scanner was tested, and its performance was characterized to determine the system sensitivity in terms of signal per incident photon as a function of x-ray energy. A Manson source was used to simultaneously expose an Amptek x-ray multi-channel analyzer and image plates, allowing for a comparison of the counts as a function of energy to the signal recorded on the image plates. NIST-certified radioactive sources were used to assign an absolute sensitivity. Results indicate that the HPX-1 scanner response matches the shape of the modeled response, allowing for absolute scaling using NIST-certified radioisotope sources. The HPX-1 scanner shows a stable response with measurements taken over one week. In contrast, the sensitivity of the DITABIS scanner was characterized using the same approach, but it exhibits changes in its response that varied by more than 50% over the span of 4 days.

42 ENGINEERING↗

Infrared quantum ghost imaging of living and undisturbed plants

Quantum ghost imaging (QGI) is a method that measures absorption at extremely low light intensities. Nondegenerate QGI probes a sample at one wavelength while forming an image with correlated photons at a different wavelength. This spectral separation alleviates the need for imaging detectors with high sensitivity in the near-infrared (NIR) region, thereby reducing the required illumination intensity. Using NCam, a single-photon detector, we demonstrated nondegenerate QGI with unprecedented sensitivity and contrast, obtaining images of living plants with less than 1% light transmission. The plants experienced 3aW/cm 2 of light during imaging, orders of magnitude below starlight. This realization of QGI expands the method to extremely low-light bioimaging and imaging of light-sensitive samples, where minimizing illumination intensity is crucial to prevent phototoxicity or sample degradation.

47 OTHER INSTRUMENTATION↗

Advancement of X-Ray Microscopy Technology and its Application to Metal Solidification Studies

The technique of x-ray projection microscopy is being used to view, in real time, the structures and dynamics of the solid-liquid interface during solidification. By employing a hard x-ray source with sub-micron dimensions, resolutions of 2 micrometers can be obtained with magnifications of over 800 X. Specimen growth conditions need to be optimized and the best imaging technologies applied to maintain x-ray image resolution, contrast and sensitivity. It turns out that no single imaging technology offers the best solution and traditional methods like radiographic film cannot be used due to specimen motion (solidification). In addition, a special furnace design is required to permit controlled growth conditions and still offer maximum resolution and image contrast.

Kaukler, William F.↗

Advancement of X-Ray Microscopy Technology and Its Application to Metal Solidification Studies

The technique of x-ray projection microscopy is being used to view, in real time, the structures and dynamics of the solid-liquid interface during solidification. By employing a hard x-ray source with sub-micron dimensions, resolutions of 2 microns can be obtained with magnifications of over 800 X. Specimen growth conditions need to be optimized and the best imaging technologies applied to maintain x-ray image resolution, contrast and sensitivity. It turns out that no single imaging technology offers the best solution and traditional methods like radiographic film cannot be used due to specimen motion (solidification). In addition, a special furnace design is required to permit controlled growth conditions and still offer maximum resolution and image contrast.

Kaukler, William F.↗

Multiplexable high-temperature stable and low-loss intrinsic Fabry-Perot in-fiber sensors through nanograting engineering

This paper presents a method of using femtosecond laser inscribed nanograting as low-loss– and high-temperature–stable in-fiber reflectors. By introducing a pair of nanograting inside the core of a single-mode optical fiber, an intrinsic Fabry-Perot interferometer can be created for high-temperature sensing applications. The morphology of the nanograting inscribed in fiber cores was engineered by tuning the fabrication conditions to achieve a high fringe visibility of 0.49 and low insertion loss of 0.002 dB per sensor. Using a white light interferometry demodulation algorithm, we demonstrate the temperature sensitivity, cross-talk, and spatial multiplexability of sensor arrays. Both the sensor performance and stability were studied from room temperature to 1000°C with cyclic heating and cooling. Our results demonstrate a femtosecond direct laser writing technique capable of producing highly multiplexable in-fiber intrinsic Fabry-Perot interferometer sensor devices with high fringe contrast, high sensitivity, and low-loss for application in harsh environmental conditions.

Wang, Mohan (ORCID:0000000166784993)↗

Climate impacts on global agriculture emerge earlier in new generation of climate and crop models

Potential climate-related impacts on future crop yield are a major societal concern. Previous projections of the Agricultural Model Intercomparison and Improvement Project’s Global Gridded Crop Model Intercomparison based on the Coupled Model Intercomparison Project Phase 5 identified substantial climate impacts on all major crops, but associated uncertainties were substantial. Here we report new twenty-first-century projections using ensembles of latest-generation crop and climate models. Results suggest markedly more pessimistic yield responses for maize, soybean and rice compared to the original ensemble. Mean end-of-century maize productivity is shifted from +5% to -6% (SSP126) and from +1% to -24% (SSP585)—explained by warmer climate projections and improved crop model sensitivities. In contrast, wheat shows stronger gains (+9% shifted to +18%, SSP585), linked to higher CO2 concentrations and expanded high-latitude gains. The ‘emergence’ of climate impacts consistently occurs earlier in the new projections—before 2040 for several main producing regions. While future yield estimates remain uncertain, these results suggest that major breadbasket regions will face distinct anthropogenic climatic risks sooner than previously anticipated.

Jagermeyr, Jonas↗

Sulfur Kβ X-ray emission spectroscopy: comparison with sulfur K-edge X-ray absorption spectroscopy for speciation of organosulfur compounds

Until recently, sulfur was known as a “spectroscopically silent” element because of a paucity of convenient spectroscopic probes suitable for in situ chemical speciation. In recent years the technique of sulfur K-edge X-ray absorption spectroscopy (XAS) has been used extensively in sulfur speciation in a variety of different fields. With an initial focus on reduced forms of organic sulfur, we have explored a complementary X-ray based spectroscopy – sulfur Kβ X-ray emission spectroscopy (XES) – as a potential analytical tool for sulfur speciation in complex samples. In this work, we compare and contrast the sensitivity of sulfur Kβ XES with that of sulfur K-edge XAS, and find differing sensitivities for the two techniques. In some cases an approach involving both sulfur K-edge XAS and sulfur Kβ XES may be a powerful combination for deducing sulfur speciation in samples containing complex mixtures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗