Search NASA⌕ Search

SEARCH · Search NASA

Results for “Conversion System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

What factors affect the prices of low-priced U.S. solar PV systems?

The price of solar PV systems has declined rapidly, yet there are some much lower-priced systems than others. This study explores the factors that determine prices in these low-priced (LP) systems. Using a data set of 42,611 residential-scale PV systems installed in the U.S. in 2013, we use quantile regressions to estimate the importance of factors affecting the installed prices for LP systems (those at the 10th percentile) in comparison to median-priced systems. We find that the value of solar to consumers-a variable that accounts for subsidies, electric rates, and PV generation levels-is associated with lower prices for LP systems but higher prices for median priced systems. Conversely, systems installed in new home construction are associated with lower prices at the median but higher prices for LP. Other variables have larger price-reducing effects on LP than on median priced systems: systems installed in Arizona and Florida, as well as commercial and thin film systems. In contrast, the following have a smaller effect on prices for LP systems than median priced systems: tracking systems, self-installations, systems installed in Massachusetts, the system size, and installer experience. Furthermore, these results highlight the complex factors at play that lead to LP systems and shed light into how such LP systems can come about.

14 SOLAR ENERGY↗

What Factors Affect the Prices of Low-Priced U.S. Solar PV Systems?

The price of solar PV systems has declined rapidly, yet there are some much lower-priced systems than others. This study explores the factors leading some systems to be so much lower priced than others. Using a data set of 42,611 residential-scale PV systems installed in the U.S. in 2013, we use quantile regressions to estimate the importance of factors affecting the installed prices for low-priced (LP) systems (those at the 10th percentile) in comparison to median-priced systems. We find that the value of solar to consumers–a variable that accounts for subsidies, electric rates, and PV generation levels–is associated with lower prices for LP systems but higher prices for median priced systems. Conversely, systems installed in new home construction are associated with lower prices at the median but higher prices for LP. Other variables have larger cost-reducing effects on LP than on median priced systems: systems installed in Arizona and Florida, as well as commercial and thin film systems. In contrast, the following have a smaller effect on prices for LP systems than median priced systems: tracking systems, self-installations, systems installed in Massachusetts, the system size, and installer experience. These results highlight the complex factors at play that lead to LP systems and shed light into how such LP systems can come about.

14 SOLAR ENERGY↗

Systems and methods for wave energy conversion

Systems for wave energy conversion that have components that can survive the harsh marine environment and that can be attached to fixed structures, such as a pier, and having the ability to naturally adjust for tidal height and methods for their use are presented.

30 DIRECT ENERGY CONVERSION↗

Advanced High-Temperature Reactor Dynamic System Model Development: April 2012 Status

The Advanced High-Temperature Reactor (AHTR) is a large-output fluoride-salt-cooled high-temperature reactor (FHR). An early-phase preconceptual design of a 1500 MW(e) power plant was developed in 2011 [Refs. 1 and 2]. An updated version of this plant is shown as Fig. 1. FHRs feature low-pressure liquid fluoride salt cooling, coated-particle fuel, a high-temperature power cycle, and fully passive decay heat rejection. The AHTR is designed to be a “walk away” reactor that requires no action to prevent large off-site releases following even severe reactor accidents. This report describes the development of dynamic system models used to further the AHTR design toward that goal. These models predict system response during warmup, startup, normal operation, and limited off-normal operating conditions. Severe accidents that include a loss-of-fluid inventory are not currently modeled. The scope of the models is limited to the plant power system, including the reactor, the primary and intermediate heat transport systems, the power conversion system, and safety-related or auxiliary heat removal systems. The primary coolant system, the intermediate heat transport system and the reactor building structure surrounding them are shown in Fig. 2. These systems are modeled in the most detail because the passive interaction of the primary system with the surrounding structure and heat removal systems, and ultimately the environment, protects the reactor fuel and the vessel from damage during severe reactor transients. The reactor silo also plays an important role during system warmup. The dynamic system modeling tools predict system performance and response. The goal is to accurately predict temperatures and pressures within the primary, intermediate, and power conversion systems and to study the impacts of design changes on those responses. The models are design tools and are not intended to be used in reactor qualification. The important details to capture in the primary system relate to flows within the reactor vessel during severe events and the resulting temperature profiles (temperature and duration) for major components. Critical components include the fuel, reactor vessel, primary piping, and the primary-to-intermediate heat exchangers (P-IHXs). The major AHTR power system loops are shown in Fig. 3. The intermediate heat transfer system is a group of three pumped salt loops that transports the energy produced in the primary system to the power conversion system. Two dynamic system models are used to analyze the AHTR. A Matlab/Simulink-based model initiated in 2011 has been updated to reflect the evolving design parameters related to the heat flows associated with the reactor vessel. The Matlab model utilizes simplified flow assumptions within the vessel and incorporates an empirical representation of the Direct Reactor Auxiliary Cooling System (DRACS). A Dymola/Modelica model incorporates a more sophisticated representation of primary coolant flow and a physics-based representation of the three-loop DRACS thermal hydraulics. This model is not currently operating in a fully integrated mode. The Matlab model serves as a prototype and provides verification for the Dymola model, and its use will be phased out as the Dymola model nears completion. The heat exchangers in the system are sized using spreadsheet-based, steady-state calculations. The detail features of the heat exchangers are programmed into the dynamic models, and the overall dimensions are used to generate realistic plant designs. For the modeling cases where the emphasis is on understanding responses within the intermediate and primary systems, the power conversion system may be modeled as a simple boundary condition at the intermediate-to-power conversion system heat exchangers.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Air-Cooled Condensers for Next Generation Geothermal Power Plants (Final Report)

This report summarizes the efforts performed under the ARRA project “Air-Cooled Condensers in Next Generation Conversion Systems”. This project examined technologies that provide near-term improvements to the performance of binary power plants utilizing air-cooled condensers. The motivation for pursuing these improvements is to reduce the power generation costs for enhanced geothermal system (EGS) resources. The study is based on two premises. • Water will not be readily available, and there will be no consumptive use of it in the surface energy conversion system. • The EGS resources utilized for power production will be at greater depths, requiring expensive wells to access the heat. In addition, these resources will have costs associated with the creation of the subsurface reservoir where heat that powers the energy conversion system is extracted. The costs associated with the well field development and EGS reservoir creation provide the impetus for using more efficient energy conversion systems, as well as conversion systems that have higher efficiencies at ‘off-design’ conditions. In identifying the more efficient conversion systems, this work focused on: • Existing technologies with the potential to increase conversion efficiency. These are commercially available technologies that are not typically used in plants operating on hydrothermal resources, • Design strategies to increase plant output during operation at higher ambient temperatures, as well as at ‘off-design’ conditions (operation at resource and ambient temperatures other than those for which the plant was designed), • The feasibility of using mixed working fluids in binary plants using air-cooled condensers. Mixtures have been shown to have the potential to increase binary plant performance by 10% to 20%. This project was originally proposed to also evaluate the use of air-cooled condensers in flash-steam geothermal plants. However, reduced funding subsequent to starting work resulted in elimination of that task.

15 GEOTHERMAL ENERGY↗

Air-Cooled Condensers for Next Generation Geothermal Power Plants (Final Report)

This report summarizes the efforts performed under the ARRA project “Air-Cooled Condensers in Next Generation Conversion Systems”. This project examined technologies that provide near-term improvements to the performance of binary power plants utilizing air-cooled condensers. The motivation for pursuing these improvements is to reduce the power generation costs for enhanced geothermal system (EGS) resources. The study is based on two premises. • Water will not be readily available, and there will be no consumptive use of it in the surface energy conversion system. • The EGS resources utilized for power production will be at greater depths, requiring expensive wells to access the heat. In addition, these resources will have costs associated with the creation of the subsurface reservoir where heat that powers the energy conversion system is extracted The costs associated with the well field development and EGS reservoir creation provide the impetus for using more efficient energy conversion systems, as well as conversion systems that have higher efficiencies at ‘off-design’ conditions. In identifying the more efficient conversion systems, this work focused on: • Existing technologies with the potential to increase conversion efficiency. These are commercially available technologies that are not typically used in plants operating on hydrothermal resources • Design strategies to increase plant output during operation at higher ambient temperatures, as wells as at ‘off-design’ conditions (operation at resource and ambient temperatures other than those for which the plant was designed) • The feasibility of using mixed working fluids in binary plants using air-cooled condensers. Mixtures have been shown to have the potential to increase binary plant performance by 10% to 20%.

15 GEOTHERMAL ENERGY↗

Grid-Connected Modular Soft-Switching Solid State Transformers (M-S4T)

The objective of this project is to develop and verify the concept of a flexible and modular soft-switching solid-state transformer (M-S4T) for direct grid-connected applications. The ability to directly connect power electronics converters to the medium voltage grid (4 kV – 13 kV), and to potentially replace the passive and bulky, but ubiquitous 60 hertz service transformer in the 25 kVA to 100 kVA range, with a more flexible and controllable device, has been regarded as the ‘holy grail’ in grid control. However, this has proven to be extremely difficult. This project has developed the solutions to several key challenges of the direct grid-connected power electronics and realized a 7.2 kV M-S4T prototype. First, a protection method to protect the M-S4T from the high voltages (110 kV for the 13 kV system) that occur on the grid due to transients and lightning strikes have been developed and experimentally verified. Second, the realization and the operation of the M-S4T based on high-voltage SiC devices (>3.3 kV) and a medium-frequency medium-voltage low-leakage transformer in a single-stage solid-state transformer with zero-voltage switching, low dv/dt, and low electromagnetic interference has been successfully demonstrated up to 7.5 kV peak. Third, an oil-cooling system and stable communication and distributed control system for converter module voltage sharing have been developed and experimentally verified. The developed M-S4T has realized a modular universal high-performance power conversion system. This conversion system is scalable to different voltage and power levels and adaptable to four-quadrant bidirectional operation. Moreover, the use of passive cooling techniques meets the equipment life requirements, and the lightning protection scheme fulfills the basic insulation level specifications for direct grid connection. Such power conversion system opens up near-term opportunities, including energy storage, solar PV, or electric vehicle charging with significant cost and footprint savings. In the longer term, the possibility of replacing the utility distribution transformer with an M-S4T will be transformative for future distribution grids with a compact footprint and full controllability to enable high renewable energy and storage penetration. In addition to the main project, this report expands on the Plus-Up projected including as part of the main award. This project developed and demonstrated the technology for autonomous collaborative inverters that can be connected in an ad hoc manner to the grid. The aim of the project was to: (1) evaluate the existing techniques for grid-connected inverters and find their limitations; (2) develop detailed requirements for grid-connected inverters in the modern grid with millions of active nodes; (3) design a unified control strategy that brings more autonomy and intelligence to grid-connected inverters, and addresses parts of the issues with the existing techniques. The proposed technique, called UniCon, enables inverters to 1) connect/disconnect to/from the grid in an ad hoc manner; (2) work based on local sensing. Slow communication could be used for a more optimized behavior; (3) work automatically in both grid-forming/grid-following mode; (4) handle large disturbances, e.g., big load step and fault, in an oscillation-free manner; (5) work collaboratively with other inverters in steady-state and during transients. UniCon can be implemented in the middle-level control; hence it is agnostic to the vendor and to the implementation of the inner voltage/current and protection loops. Furthermore, a new synchronization scheme, based on deep learning, was developed that can extract the grid voltage phase and amplitude in a stable manner. The method is cheap to implement can improve the dynamic performance of the grid-connected inverters during fast transients, e.g., fault. The proposed control scheme was validated by (1) MATLAB/Simulink; (2) hardware-in-the-loop results, and; (3) experimental results using three inverters that form a microgrid in a down-scaled feeder. Lastly, both the M-S4T and UniCon have achieved promising tangible paths to markets. In the case of the M-S4T, the underlying technology — the Soft Switching Solid State Transformer (S4T) developed at the Georgia Tech Center for Distributed Energy (GT-CDE) has been licensed by GridBlock from the Georgia Tech Research Corporation, and GridBlock has been working with manufacturing partner Jabil (one of the largest US-based contract manufacturers) and system integrator Power Secure (largest deployer of microgrids in the US with 4.7 GW under management), to meet the strong initial demand. Similarly, GridBlock has an exclusive license to the UniCon technology, developed under this award by GT-CDE. The UniCon provides an intermediate control layer that enables the implementation of the higher-level ‘transactive’ control commands for the system. The architecture of the system - slow communications with the cloud for system optimization and setpoints, and the use of locally measured quantities for real-time control, provide a very robust and secure way of implementing a real-time must-run grid that is also secure and stable. This is a brand-new functionality that is critical for the future grid and key to GridBlock’s business model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fuel Economy and Emissions of a Vehicle Equipped with an Aftermarket Flexible-Fuel Conversion Kit

The U.S. Environmental Protection Agency (EPA) grants Certificates of Conformity for alternative fuel conversion systems and also offers other forms of premarket registration of conversion kits for use in vehicles more than two model years old. Use of alternative fuels such as ethanol, natural gas, and propane are encouraged by the Energy Policy Act of 1992. Several original equipment manufacturers (OEMs) produce emissions-certified vehicles capable of using alternative fuels, and several alternative fuel conversion system manufacturers produce EPA-approved conversion systems for a variety of alternative fuels and vehicle types. To date, only one manufacturer (Flex Fuel U.S.) has received EPA certifications for ethanol fuel (E85) conversion kits. This report details an independent evaluation of a vehicle with a legal installation of a Flex Fuel U.S. conversion kit. A 2006 Dodge Charger was baseline tested with ethanol-free certification gasoline (E0) and E20 (gasoline with 20 vol % ethanol), converted to flex-fuel operation via installation of a Flex Box Smart Kit from Flex Fuel U.S., and retested with E0, E20, E50, and E81. Test cycles included the Federal Test Procedure (FTP or city cycle), the highway fuel economy test (HFET), and the US06 test (aggressive driving test). Averaged test results show that the vehicle was emissions compliant on E0 in the OEM condition (before conversion) and compliant on all test fuels after conversion. Average nitrogen oxide (NO X ) emissions exceeded the Tier 2/Bin 5 intermediate life NO X standard with E20 fuel in the OEM condition due to two of three test results exceeding this standard [note that E20 is not a legal fuel for non-flexible-fuel vehicles (non-FFVs)]. In addition, one E0 test result before conversion and one E20 test result after conversion exceeded the NO X standard, although the average result in these two cases was below the standard. Emissions of ethanol and acetaldehyde increased with increasing ethanol, while nonmethane organic gas and CO emissions remained relatively unchanged for all fuels and cycles. Higher fraction ethanol blends appeared to decrease NO X emissions on the FTP and HFET (after conversion). As expected, fuel economy (miles per gallon) decreased with increasing ethanol content in all cases.

02 PETROLEUM↗

Protocol for Uniformly Measuring and Expressing the Performance of Energy Storage Systems

This Protocol provides a set of “best practices” for characterizing energy storage systems (ESSs) and measuring and reporting their performance. It serves as a basis for assessing how an ESS will perform with respect to key performance attributes relevant to different applications. It is intended to provide a valid and accurate basis for the comparison of different ESSs. By achieving the stated purpose, the Protocol will enable more informed decision-making in the selection of ESSs for various stationary applications. The Protocol identifies general information and technical specifications relevant in describing an ESS and also defines a set of test, measurement, and evaluation criteria with which to express the performance of ESSs that are intended for energy-intensive and/or power-intensive stationary applications. An ESS includes a storage device, battery management system, and any power conversion systems installed with the storage device. The Protocol is agnostic with respect to the storage technology and the size and rating of the ESS. The Protocol does not apply to single-use storage devices and storage devices that are not coupled with power conversion systems, nor does it address safety, security, or operations and maintenance of ESSs, or provide any pass/fail criteria.

25 ENERGY STORAGE↗

Magnet Technology for Power Converters: Nanocomposite Magnet Technology for High Frequency MW-Scale Power Converters

Solar ADEPT Project: CMU is developing a new nanoscale magnetic material that will reduce the size, weight, and cost of utility-scale PV solar power conversion systems that connect directly to the grid. Power converters are required to turn the energy that solar power systems create into useable energy for the grid. The power conversion systems made with CMU’s nanoscale magnetic material have the potential to be 150 times lighter and significantly smaller than conventional power conversion systems that produce similar amounts of power.

ARPA-E↗

Conceptual System Design of a Supercritical CO{sub 2} cooled Micro Modular Reactor - 18492

Small modular reactor (SMR) concepts proposed in the past have compact size and a longer life reactor core than the conventional nuclear power plants. However, previous concepts based on the water-cooled technologies with a steam Rankine cycle have shown that the complete modularization is still technically challenging. This study suggests an innovative concept of a reactor directly cooled by supercritical carbon dioxide (S-CO{sub 2}) with S-CO{sub 2} Brayton cycle as a power conversion system, namely KAIST MMR (Micro Modular Reactor). To enhance neutron economy and maximize the fuel volume fraction of the core, a uranium carbide fuel controlled by drum type control rods was used in the fast-spectrum MMR. The core has long life (20 years) without refueling or reshuffling as well as inherent safety features. The reactor can be used as a distributed power source, and replace outdated fossil fuel power plants for small cities. Moreover, we propose a S-CO{sub 2} Brayton cycle as a power conversion system to achieve small, high performance and lightweight module. Thanks to the compact core and power conversion system, the entire system can be contained in a single module. The target of the system is to achieve small and compact system that can be transported via ground transportation of a single module containing the core and the power conversion system altogether. In order to meet this target single module s total weight is minimized in the order of 150 tons. The external size of a module is less than 7 m in length and 4 m in diameter. It produces 12 MWe electricity from 36 MWt reactor core. The S-CO{sub 2} Brayton cycle was optimized, and the cycle components were designed while maximizing the performance and minimizing the weight. A passive decay heat removal system utilizing shell and tube heat exchangers was also developed, and examined its performance with transient analysis code. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Operando Studies Reveal Structural Evolution with Electrochemical Cycling in Li–CoS 2

The desire for high energy density alternatives to Li-ion batteries has led to great interest in energy storage materials not inherently constrained by the capacity limits of standard intercalation electrode materials currently employed in commercial devices. Among the alternatives under consideration are electrode materials with theoretical capacities many times greater than intercalation electrodes, including those that store charge through so-called conversion reactions. However, the vast structural changes that enable the high theoretical capacity of conversion systems contribute to issues of poor efficiency and short cycle life. To better understand the cycling issues in conversion systems, we study the local structure evolution of the cathode active material in LiCoS 2 cells. Being metallic, and potentially being capable of redox on both the anion and cation, we would expect CoS 2 to be a promising cathode material. Through combined ex situ X-ray absorption near-edge spectroscopy and pair distribution function analysis from operando X-ray total scattering, we describe the reactions that take place over the first 1.5 cycles. In doing so, we identify the irreversible formation of a Co 9 S 8 -like local structure with significantly limited electrochemical activity as the primary source of capacity fade. The methods employed here and the insights that emerge inform the rational design of conversion systems for electrochemical energy storage.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Very High Efficiency Dedicated Outdoor Air System Field Site Re-Evaluation

The study reported here evaluated the long-term performance of Very High Efficiency (VHE) Dedicated Outside Air Systems (DOASs) installed at eight sites that participated in field evaluation studies performed by the Northwest Energy Efficiency Alliance (NEEA) and Institute for Market Transformation (IMT) from 2015 through 2020. The study compared the energy performance of the systems in 2021-2022 to the findings of the original evaluation. It also evaluated the indoor environmental quality (IEQ) as perceived by occupants and building operator feedback before and after the system conversion. The findings of the study are important for building owners and managers who are considering adopting VHE DOASs. The study found that the systems: (1) consistently saved energy over the long term, (2) improved occupant comfort, and (3) received positive feedback from building operators. All of the sites had similar or improved energy savings over the pre-conversion system compared to the original evaluation savings, and only one site had a small reduction in energy savings. The sites averaged 48 percent whole site energy savings compared to the pre-conversion system. The continued energy performance of these sites provides strong evidence that the energy savings achieved by VHE DOAS retrofits will be sustained long term. The study also investigated the changes in occupant comfort resulting from the VHE DOAS retrofit. Responses to a survey sent to the sites’ occupants revealed that the conversion resulted in a better indoor environment for the occupants. Most respondents reported that their satisfaction increased, and dissatisfaction decreased post-conversion. Overall occupants were 43 percent more satisfied and 30 percent less dissatisfied post-conversion compared to pre-conversion. The study's findings suggest that a VHE DOAS can be a solution to improve the energy efficiency, reduce energy costs, and increase occupant comfort in buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

MEITNER Resource Team Modeling and Simulation Support to Holos-Quad Reactor Development (Final CRADA Report)

The main objective of this CRADA is to provide Argonne National Laboratory (ANL)’s modeling and simulation capabilities via ARPA-E's MEITNER (Modeling-Enhanced Innovations Trailblazing Nuclear Energy Reinvigoration) Resource Team (RT) arrangement to support the demonstration of the viability of HolosGen’s Holos-Quad reactor design. The Holos-Quad reactor design is an advanced reactor concept that incorporates many new design features, such as the neutron-coupled Subcritical Power Modules (SPMs) in its core design, elimination of balance of plant (BOP) by direct integration of a helium Brayton cycle power conversion system with each SPM, among many other innovative features. The demonstration of the viability of such an innovative reactor design warrants iterations of modeling and simulation and testing. The purpose of this project is to utilize ANL’s modeling and simulation capabilities in nuclear reactor analysis and power conversion system analysis to inform HolosGen and the Design Team (DT) in the design and optimization of the Holos-Quad concept. The major work scopes of this project include: to investigate conceptual designs and materials for radiation shielding to protect personnel and internal components such as turbomachinery; Assess the the helium Brayton cycle power conversion system performance in both nominal and load following conditions; Investigate power conversion components and overall system performance; Identify control strategies to enable load following; Perform simulations of HolosGen’s subscale simulator and using available test data for code validation/benchmark purpose; Perform core thermal-hydraulics, safety analysis, and structural analysis.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Application of Ocean Thermal Energy Conversion (OTEC) Systems for Powering Safety Monitoring Systems of Offshore Oil and Gas Operations, OESI 2.0 M-1 T-1-P1.1 – Objective 3 Report: Collocation of OTEC with Offshore Oil and Gas Activities

This report is a component of a comprehensive research initiative aimed at evaluating the technoeconomic feasibility of deploying Ocean Thermal Energy Conversion (OTEC) systems to power safety monitoring systems for offshore oil and gas operations in the Gulf of America (GOA). The overarching study has three primary objectives: summarizing existing oil and gas equipment monitoring systems, modeling OTEC as a renewable marine energy source, and exploring the collocation of OTEC power sources with offshore oil and gas activities to offset power demand. This report specifically addresses Objective 3, focusing on the integration of OTEC systems with floating oil and gas facilities.

02 PETROLEUM↗

Biomass Recalcitrance in Willow Under Two Biological Conversion Paradigms: Enzymatic Hydrolysis and Anaerobic Digestion

Biomass recalcitrance, the inherent resistance of plants towards deconstruction, negatively affects the viability of biorefineries. This trait is not only dictated by the properties of the biomass but also by the conversion system used and its interactions with specific features of the biomass. Here, biomass recalcitrance to anaerobic digestion (AD) was assessed using a biomethanation potential (BMP) assay. Plant material (n = 94) was selected from a large population of natural Salix viminalis accessions, previously evaluated for biomass recalcitrance using hydrothermal pretreatment-enzymatic hydrolysis. Correlations between yields from the two biological conversion systems were evaluated, as well as the influence of biomass compositional features, analyzed by pyrolysis-molecular beam mass spectrometry (py-MBMS), and other biomass physical properties on conversion performance. BMP values averaged 198.0 Nml CH 4 /g biomass after 94 days, ranging from 28.6 to 245.9. S lignin and carbohydrate-derived spectral features were positively correlated with performance under both systems, whereas G lignin, p-coumaric acid, and ferulic acid-derived ions were negatively correlated with yields and rates. Most spectral features were more strongly correlated with enzymatic hydrolysis yields compared to methane production. For early-stage methane production and rate, recalcitrance factors were similar compared to enzymatic hydrolysis, with weaker correlations observed at later timepoints. The results suggest that although variation in methane potential was considerably lower than enzymatic hydrolysis yields, a reduced recalcitrance under this system will still be of importance to improve early conversion rates. Spectral features of low methane-producing samples indicate the presence of inhibitory substances, warranting further study.

59 BASIC BIOLOGICAL SCIENCES↗

Secondary Heat Exchanger Design and Comparison for Advanced High Temperature Reactor

The goals of next generation nuclear reactors, such as the high temperature gas-cooled reactor and advance high temperature reactor (AHTR), are to increase energy efficiency in the production of electricity and provide high temperature heat for industrial processes. The efficient transfer of energy for industrial applications depends on the ability to incorporate effective heat exchangers between the nuclear heat transport system and the industrial process heat transport system. The need for efficiency, compactness, and safety challenge the boundaries of existing heat exchanger technology, giving rise to the following study. Various studies have been performed in attempts to update the secondary heat exchanger that is downstream of the primary heat exchanger, mostly because its performance is strongly tied to the ability to employ more efficient conversion cycles, such as the Rankine super critical and subcritical cycles. This study considers two different types of heat exchangers—helical coiled heat exchanger and printed circuit heat exchanger—as possible options for the AHTR secondary heat exchangers with the following three different options: (1) A single heat exchanger transfers all the heat (3,400 MW(t)) from the intermediate heat transfer loop to the power conversion system or process plants; (2) Two heat exchangers share heat to transfer total heat of 3,400 MW(t) from the intermediate heat transfer loop to the power conversion system or process plants, each exchanger transfers 1,700 MW(t) with a parallel configuration; and (3) Three heat exchangers share heat to transfer total heat of 3,400 MW(t) from the intermediate heat transfer loop to the power conversion system or process plants. Each heat exchanger transfers 1,130 MW(t) with a parallel configuration. A preliminary cost comparison will be provided for all different cases along with challenges and recommendations.

42 ENGINEERING↗