Search NASA⌕ Search

SEARCH · Search NASA

Results for “Count”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

An Evaluation of Redd Counts as a Measure of Bull Trout Population Size and Trend

Abstract The use of redd counts to monitor abundance and trend of bull trout Salvelinus confluentus has been clouded by uncertainties concerning measurement error, life history variation, and correspondence of redd counts to adult population size. We compared census redd counts with population estimates of mature females for a migratory fluvial population of bull trout (primarily ≥ 300 mm fork length) and for a population of small (<200 mm), likely resident, bull trout. We also compared the measurement error of the experienced surveyors who conducted the redd counts to that of a group of inexperienced surveyors. Although the regression of redd counts on adult females for the migratory population was statistically significant, a large proportion of the variation in the relationship was unexplained (r 2 = 0.47). Despite that variation, redd counts accurately reflected a greater than 50% decline in the population over 10 years; however, 5-year trends in redd counts could be misleading. Power analysis parameterized by using the variation in the number of females per redd and measurement error of experienced surveyors indicated that minimum declines of 44–56% or increases of 78–118% over 10–15 years would be necessary for detection using traditional statistical criteria. Geometric mean abundance of migratory adults derived from redd counts and adults-per-redd values from the present study and published averages were similar to measured adult numbers in most cases. For both migratory and resident populations, redd counts by experienced surveyors were substantially more accurate and precise than those by inexperienced surveyors. Counts of migratory bull trout redds were more accurate and precise than counts of resident bull trout redds, which were significantly smaller and consistently underestimated. Thus, bull trout redd counts can be used to estimate abundance levels and to detect substantial longer-term changes in abundance, particularly for migratory populations. However, the reliability of the counts depends on the skill of the surveyors. Received April 4, 2011; accepted August 8, 2011

Howell, Philip J.↗

Optical People Counting for Demand Controlled Ventilation: A Pilot Study of Counter Performance

This pilot scale study evaluated the counting accuracy of two people counting systems that could be used in demand controlled ventilation systems to provide control signals for modulating outdoor air ventilation rates. The evaluations included controlled challenges of the people counting systems using pre-planned movements of occupants through doorways and evaluations of counting accuracies when naive occupants (i.e., occupants unaware of the counting systems) passed through the entrance doors of the building or room. The two people counting systems had high counting accuracy accuracies, with errors typically less than 10percent, for typical non-demanding counting events. However, counting errors were high in some highly challenging situations, such as multiple people passing simultaneously through a door. Counting errors, for at least one system, can be very high if people stand in the field of view of the sensor. Both counting system have limitations and would need to be used only at appropriate sites and where the demanding situations that led to counting errors were rare.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

OPTIMAL CAPTURE OF NON-GAUSSIANITY IN WEAK-LENSING SURVEYS: POWER SPECTRUM, BISPECTRUM, AND HALO COUNTS

We compare the efficiency of weak-lensing-selected galaxy cluster counts and of the weak-lensing bispectrum at capturing non-Gaussian features in the dark matter distribution. We use the halo model to compute the weak-lensing power spectrum, the bispectrum, and the expected number of detected clusters, and derive constraints on cosmological parameters for a large, low systematic weak-lensing survey, by focusing on the OMEGA{sub m}-sigma{sub 8} plane and on the dark energy equation of state. We separate the power spectrum into the resolved and the unresolved parts of the data, the resolved part being defined as detected clusters, and the unresolved part as the rest of the field. We consider four kinds of clusters counts, taking into account different amount of information: signal-to-noise ratio peak counts, counts as a function of clusters' mass, counts as a function of clusters' redshift, and counts as a function of clusters' mass and redshift. We show that when combined with the power spectrum, those four kinds of counts provide similar constraints, thus allowing one to perform the most direct counts, signal-to-noise peak counts, and get percent level constraints on cosmological parameters. We show that the weak-lensing bispectrum gives constraints comparable to those given by the power spectrum and captures non-Gaussian features as well as cluster counts, its combination with the power spectrum giving errors on cosmological parameters that are similar to, if not marginally smaller than, those obtained when combining the power spectrum with cluster counts. We finally note that in order to reach its potential, the weak-lensing bispectrum must be computed using all triangle configurations, as equilateral triangles alone do not provide useful information. The appendices summarize the halo model, and the way the power spectrum and bispectrum are computed in this framework.

79 ASTRONOMY AND ASTROPHYSICS↗

THE HUBBLE SPACE TELESCOPE WIDE FIELD CAMERA 3 EARLY RELEASE SCIENCE DATA: PANCHROMATIC FAINT OBJECT COUNTS FOR 0.2-2 {mu}m WAVELENGTH

We describe the Hubble Space Telescope (HST) Wide Field Camera 3 (WFC3) Early Release Science (ERS) observations in the Great Observatories Origins Deep Survey (GOODS) South field. The new WFC3 ERS data provide calibrated, drizzled mosaics in the UV filters F225W, F275W, and F336W, as well as in the near-IR filters F098M (Y{sub s} ), F125W (J), and F160W (H) with 1-2 HST orbits per filter. Together with the existing HST Advanced Camera for Surveys (ACS) GOODS-South mosaics in the BViz filters, these panchromatic 10-band ERS data cover 40-50 arcmin{sup 2} at 0.2-1.7 {mu}m in wavelength at 0.''07-0.''15 FWHM resolution and 0.''090 Multidrizzled pixels to depths of AB {approx_equal} 26.0-27.0 mag (5{sigma}) for point sources, and AB {approx_equal} 25.5-26.5 mag for compact galaxies. In this paper, we describe (1) the scientific rationale, and the data taking plus reduction procedures of the panchromatic 10-band ERS mosaics, (2) the procedure of generating object catalogs across the 10 different ERS filters, and the specific star-galaxy separation techniques used, and (3) the reliability and completeness of the object catalogs from the WFC3 ERS mosaics. The excellent 0.''07-0.''15 FWHM resolution of HST/WFC3 and ACS makes star-galaxy separation straightforward over a factor of 10 in wavelength to AB {approx_equal} 25-26 mag from the UV to the near-IR, respectively. Our main results are: (1) proper motion of faint ERS stars is detected over 6 years at 3.06 {+-} 0.66 mas year{sup -1} (4.6{sigma}), consistent with Galactic structure models; (2) both the Galactic star counts and the galaxy counts show mild but significant trends of decreasing count slopes from the mid-UV to the near-IR over a factor of 10 in wavelength; (3) combining the 10-band ERS counts with the panchromatic Galaxy and Mass Assembly survey counts at the bright end (10 mag {approx}< AB {approx}< 20 mag) and the Hubble Ultra Deep Field counts in the BVizY{sub s}JH filters at the faint end (24 mag {approx}< AB {approx}< 30 mag) yields galaxy counts that are well measured over the entire flux range 10 mag {approx}< AB {approx}< 30 mag for 0.2-2 {mu}m in wavelength; (4) simple luminosity+density evolution models can fit the galaxy counts over this entire flux range. However, no single model can explain the counts over this entire flux range in all 10 filters simultaneously. More sophisticated models of galaxy assembly are needed to reproduce the overall constraints provided by the current panchromatic galaxy counts for 10 mag {approx}< AB {approx}< 30 mag over a factor of 10 in wavelength.

79 ASTRONOMY AND ASTROPHYSICS↗

Association Between White Blood Cell Count Following Radiation Therapy With Radiation Pneumonitis in Non-Small Cell Lung Cancer

Purpose: Radiation pneumonitis (RP) is an inflammatory response to radiation therapy (RT). We assessed the association between RP and white blood cell (WBC) count, an established metric of systemic inflammation, after RT for non-small cell lung cancer. Methods and Materials: We retrospectively analyzed 366 patients with non-small cell lung cancer who received ≥60 Gy as definitive therapy. The primary endpoint was whether WBC count after RT (defined as 2 weeks through 3 months after RT completion) was associated with grade ≥3 or grade ≥2 RP. Median lung volume receiving ≥20 Gy (V{sub 20}) was 31%, and post-RT WBC counts ranged from 1.7 to 21.2 × 10{sup 3} WBCs/μL. Odds ratios (ORs) associating clinical variables and post-RT WBC counts with RP were calculated via logistic regression. A recursive-partitioning algorithm was used to define optimal post-RT WBC count cut points. Results: Post-RT WBC counts were significantly higher in patients with grade ≥3 RP than without (P<.05). Optimal cut points for post-RT WBC count were found to be 7.4 and 8.0 × 10{sup 3}/μL for grade ≥3 and ≥2 RP, respectively. Univariate analysis revealed significant associations between post-RT WBC count and grade ≥3 (n=46, OR=2.6, 95% confidence interval [CI] 1.4‒4.9, P=.003) and grade ≥2 RP (n=164, OR=2.0, 95% CI 1.2‒3.4, P=.01). This association held in a stepwise multivariate regression. Of note, V{sub 20} was found to be significantly associated with grade ≥2 RP (OR=2.2, 95% CI 1.2‒3.4, P=.01) and trended toward significance for grade ≥3 RP (OR=1.9, 95% CI 1.0-3.5, P=.06). Conclusions: Post-RT WBC counts were significantly and independently associated with RP and have potential utility as a diagnostic or predictive marker for this toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

THE 4 Ms CHANDRA DEEP FIELD-SOUTH NUMBER COUNTS APPORTIONED BY SOURCE CLASS: PERVASIVE ACTIVE GALACTIC NUCLEI AND THE ASCENT OF NORMAL GALAXIES

We present 0.5-2 keV, 2-8 keV, 4-8 keV, and 0.5-8 keV (hereafter soft, hard, ultra-hard, and full bands, respectively) cumulative and differential number-count (log N-log S) measurements for the recently completed Almost-Equal-To 4 Ms Chandra Deep Field-South (CDF-S) survey, the deepest X-ray survey to date. We implement a new Bayesian approach, which allows reliable calculation of number counts down to flux limits that are factors of Almost-Equal-To 1.9-4.3 times fainter than the previously deepest number-count investigations. In the soft band (SB), the most sensitive bandpass in our analysis, the Almost-Equal-To 4 Ms CDF-S reaches a maximum source density of Almost-Equal-To 27,800 deg{sup -2}. By virtue of the exquisite X-ray and multiwavelength data available in the CDF-S, we are able to measure the number counts from a variety of source populations (active galactic nuclei (AGNs), normal galaxies, and Galactic stars) and subpopulations (as a function of redshift, AGN absorption, luminosity, and galaxy morphology) and test models that describe their evolution. We find that AGNs still dominate the X-ray number counts down to the faintest flux levels for all bands and reach a limiting SB source density of Almost-Equal-To 14,900 deg{sup -2}, the highest reliable AGN source density measured at any wavelength. We find that the normal-galaxy counts rise rapidly near the flux limits and, at the limiting SB flux, reach source densities of Almost-Equal-To 12,700 deg{sup -2} and make up 46% {+-} 5% of the total number counts. The rapid rise of the galaxy counts toward faint fluxes, as well as significant normal-galaxy contributions to the overall number counts, indicates that normal galaxies will overtake AGNs just below the Almost-Equal-To 4 Ms SB flux limit and will provide a numerically significant new X-ray source population in future surveys that reach below the Almost-Equal-To 4 Ms sensitivity limit. We show that a future Almost-Equal-To 10 Ms CDF-S would allow for a significant increase in X-ray-detected sources, with many of the new sources being cosmologically distant (z {approx}> 0.6) normal galaxies.

79 ASTRONOMY AND ASTROPHYSICS↗

Image-based spectral distortion correction for photon-counting x-ray detectors

Purpose: To investigate the feasibility of using an image-based method to correct for distortions induced by various artifacts in the x-ray spectrum recorded with photon-counting detectors for their application in breast computed tomography (CT). Methods: The polyenergetic incident spectrum was simulated with the tungsten anode spectral model using the interpolating polynomials (TASMIP) code and carefully calibrated to match the x-ray tube in this study. Experiments were performed on a Cadmium-Zinc-Telluride (CZT) photon-counting detector with five energy thresholds. Energy bins were adjusted to evenly distribute the recorded counts above the noise floor. BR12 phantoms of various thicknesses were used for calibration. A nonlinear function was selected to fit the count correlation between the simulated and the measured spectra in the calibration process. To evaluate the proposed spectral distortion correction method, an empirical fitting derived from the calibration process was applied on the raw images recorded for polymethyl methacrylate (PMMA) phantoms of 8.7, 48.8, and 100.0 mm. Both the corrected counts and the effective attenuation coefficient were compared to the simulated values for each of the five energy bins. The feasibility of applying the proposed method to quantitative material decomposition was tested using a dual-energy imaging technique with a three-material phantom that consisted of water, lipid, and protein. The performance of the spectral distortion correction method was quantified using the relative root-mean-square (RMS) error with respect to the expected values from simulations or areal analysis of the decomposition phantom. Results: The implementation of the proposed method reduced the relative RMS error of the output counts in the five energy bins with respect to the simulated incident counts from 23.0%, 33.0%, and 54.0% to 1.2%, 1.8%, and 7.7% for 8.7, 48.8, and 100.0 mm PMMA phantoms, respectively. The accuracy of the effective attenuation coefficient of PMMA estimate was also improved with the proposed spectral distortion correction. Finally, the relative RMS error of water, lipid, and protein decompositions in dual-energy imaging was significantly reduced from 53.4% to 6.8% after correction was applied. Conclusions: The study demonstrated that dramatic distortions in the recorded raw image yielded from a photon-counting detector could be expected, which presents great challenges for applying the quantitative material decomposition method in spectral CT. The proposed semi-empirical correction method can effectively reduce these errors caused by various artifacts, including pulse pileup and charge sharing effects. Furthermore, rather than detector-specific simulation packages, the method requires a relatively simple calibration process and knowledge about the incident spectrum. Therefore, it may be used as a generalized procedure for the spectral distortion correction of different photon-counting detectors in clinical breast CT systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Trust: Triangle Counting Reloaded on GPUs

Triangle counting is a building block for a wide range of graph applications. Here, traditional wisdom suggests that i) hashing is not suitable for triangle counting, ii) edge-centric triangle counting beats vertex-centric design, and iii) communication-free and workload balanced graph partitioning is a grand challenge for triangle counting. On the contrary, we advocate that i) hashing can help the key operations for scalable triangle counting on Graphics Processing Units (GPUs), i.e., list intersection and graph partitioning, ii) vertex-centric option reduces both hash table construction cost and memory consumption, which is limited on GPUs. In addition, iii) we exploit graph and workload collaborative, and hash-based 2D partitioning to scale vertex-centric triangle counting over 1,000 GPUs with sustained scalability. In this work, we present TRUST, which performs triangle counting with the hash operation and vertex-centric paradigm. To the best of our knowledge, TRUST is the first work that achieves over one trillion Traversed Edges Per Second (TEPS) rate for triangle counting.

97 MATHEMATICS AND COMPUTING↗

Inferring occupant counts from Wi-Fi data in buildings through machine learning

An important approach to curtail building energy consumption is to optimize building control based on occupancy information. Various studies proposed to estimate occupant counts through different approaches and sensors. However, high cost and privacy concerns remain as major barriers, restricting the practice of occupant count detection. In this study, we propose a novel method utilizing data from widely deployed Wi-Fi infrastructure to infer occupant counts through machine learning. Compared with the current indirect measurement methods, our method improves the performance of estimating people count: (1) we avoid privacy concerns by anonymizing and reshuffling the MAC addresses on a daily basis; (2) we adopted a heuristic feature engineer approach to cluster connected devices into different types based on their daily connection duration. We tested the method in an office building located in California. In an area with an average occupancy of 22–27 people and a peak occupancy of 48 - 74 people, the root square mean error on the test set is less than four people. The error is within two people counts for more than 70% of estimations, and less than six counts for more than 90% of estimations, indicating a relatively high accuracy. The major contribution of this study is proposing a novel and accurate approach to detect occupant counts in a non-intrusive way, i.e., utilizing existing Wi-Fi infrastructure in buildings without requiring the installation of extra hardware or sensors. The method we proposed is generic and could be applied to other commercial buildings to infer occupant counts for energy efficient building control.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterizing and predicting ultrafine particle counts in Canadian classrooms during the winter months: Model development and evaluation

School classrooms are potentially important micro-environments for childhood exposures owing to the large amount of time children spend in these locations. While a number of airborne contaminants may be present in schools, to date few studies have examined ultrafine particle (0.02-1 {mu}m) (UFP) levels in classrooms. In this study, our objective was to characterize UFP counts (cm{sup -3}) in classrooms during the winter months and to develop a model to predict such exposures based on ambient weather conditions and outdoor UFPs, as well as classroom characteristics such as size, temperature, relative humidity, and carbon dioxide levels. In total, UFP count data were collected on 60 occasions in 37 occupied classrooms at one elementary school and one secondary school in Pembroke, Ontario. On average, outdoor UFP levels exceeded indoor measures by 8989 cm{sup -3} (95% confidence interval (CI): 6382, 11 596), and classroom UFP counts were similar at both schools with a combined average of 5017 cm{sup -3} (95% CI: 4300, 5734). Of the variables examined only wind speed and outdoor UFPs were important determinants of classrooms UFP levels. Specifically, each 10 km/h increase in wind speed corresponded to an 1873 cm{sup -3} (95% CI: 825, 2920) decrease in classroom UFP counts, and each 10 000 cm{sup -3} increase in outdoor UFPs corresponded to a 1550 cm{sup -3} (95% CI: 930, 2171) increase in classroom UFP levels. However, high correlations between these two predictors meant that the independent effects of wind speed and outdoor UFPs could not be separated in multivariable models, and only outdoor UFP counts were included in the final predictive model. To evaluate model performance, classroom UFP counts were collected for 8 days at two new schools and compared to predicted values based on outdoor UFP measures. A moderate correlation was observed between measured and predicted classroom UFP counts (r=0.63) for both schools combined, but this relationship was not valid on days in which a strong indoor UFP source (electric kitchen stove) was active in schools. In general, our findings suggest that reasonable estimates of classroom UFP counts may be obtained from outdoor UFP data but that the accuracy of such estimates are limited in the presence of indoor UFP sources.

60 APPLIED LIFE SCIENCES↗

Modeling the performance of a photon counting x-ray detector for CT: Energy response and pulse pileup effects

Purpose: Recently, photon counting x-ray detectors (PCXDs) with energy discrimination capabilities have been developed for potential use in clinical computed tomography (CT) scanners. These PCXDs have great potential to improve the quality of CT images due to the absence of electronic noise and weights applied to the counts and the additional spectral information. With high count rates encountered in clinical CT, however, coincident photons are recorded as one event with a higher or lower energy due to the finite speed of the PCXD. This phenomenon is called a ''pulse pileup event'' and results in both a loss of counts (called ''deadtime losses'') and distortion of the recorded energy spectrum. Even though the performance of PCXDs is being improved, it is essential to develop algorithmic methods based on accurate models of the properties of detectors to compensate for these effects. To date, only one PCXD (model DXMCT-1, DxRay, Inc., Northridge, CA) has been used for clinical CT studies. The aim of that study was to evaluate the agreement between data measured by DXMCT-1 and those predicted by analytical models for the energy response, the deadtime losses, and the distorted recorded spectrum caused by pulse pileup effects. Methods: An energy calibration was performed using {sup 99m}Tc (140 keV), {sup 57}Co (122 keV), and an x-ray beam obtained with four x-ray tube voltages (35, 50, 65, and 80 kVp). The DXMCT-1 was placed 150 mm from the x-ray focal spot; the count rates and the spectra were recorded at various tube current values from 10 to 500 {mu}A for a tube voltage of 80 kVp. Using these measurements, for each pulse height comparator we estimated three parameters describing the photon energy-pulse height curve, the detector deadtime {tau}, a coefficient k that relates the x-ray tube current I to an incident count rate a by a=kxI, and the incident spectrum. The mean pulse shape of all comparators was acquired in a separate study and was used in the model to estimate the distorted recorded spectrum. The agreement between data measured by the DXMCT-1 and those predicted by the models was quantified by the coefficient of variation (COV), i.e., the root mean square difference divided by the mean of the measurement. Results: Photon energy versus pulse height curves calculated with an analytical model and those measured using the DXMCT-1 were in agreement within 0.2% in terms of the COV. The COV between the output count rates measured and those predicted by analytical models was 2.5% for deadtime losses of up to 60%. The COVs between spectra measured and those predicted by the detector model were within 3.7%-7.2% with deadtime losses of 19%-46%. Conclusions: It has been demonstrated that the performance of the DXMCT-1 agreed exceptionally well with the analytical models regarding the energy response, the count rate, and the recorded spectrum with pulse pileup effects. These models will be useful in developing methods to compensate for these effects in PCXD-based clinical CT systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Material separation in x-ray CT with energy resolved photon-counting detectors

Purpose: The objective of the study was to demonstrate that, in x-ray computed tomography (CT), more than two types of materials can be effectively separated with the use of an energy resolved photon-counting detector and classification methodology. Specifically, this applies to the case when contrast agents that contain K-absorption edges in the energy range of interest are present in the object. This separation is enabled via the use of recently developed energy resolved photon-counting detectors with multiple thresholds, which allow simultaneous measurements of the x-ray attenuation at multiple energies. Methods: To demonstrate this capability, we performed simulations and physical experiments using a six-threshold energy resolved photon-counting detector. We imaged mouse-sized cylindrical phantoms filled with several soft-tissue-like and bone-like materials and with iodine-based and gadolinium-based contrast agents. The linear attenuation coefficients were reconstructed for each material in each energy window and were visualized as scatter plots between pairs of energy windows. For comparison, a dual-kVp CT was also simulated using the same phantom materials. In this case, the linear attenuation coefficients at the lower kVp were plotted against those at the higher kVp. Results: In both the simulations and the physical experiments, the contrast agents were easily separable from other soft-tissue-like and bone-like materials, thanks to the availability of the attenuation coefficient measurements at more than two energies provided by the energy resolved photon-counting detector. In the simulations, the amount of separation was observed to be proportional to the concentration of the contrast agents; however, this was not observed in the physical experiments due to limitations of the real detector system. We used the angle between pairs of attenuation coefficient vectors in either the 5-D space (for non-contrast-agent materials using energy resolved photon-counting acquisition) or a 2-D space (for contrast agents using energy resolved photon-counting acquisition and all materials using dual-kVp acquisition) as a measure of the degree of separation. Compared to dual-kVp techniques, an energy resolved detector provided a larger separation and the ability to separate different target materials using measurements acquired in different energy window pairs with a single x-ray exposure. Conclusions: We concluded that x-ray CT with an energy resolved photon-counting detector with more than two energy windows allows the separation of more than two types of materials, e.g., soft-tissue-like, bone-like, and one or more materials with K-edges in the energy range of interest. Separating material types using energy resolved photon-counting detectors has a number of advantages over dual-kVp CT in terms of the degree of separation and the number of materials that can be separated simultaneously.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TH-EF-207A-03: Photon Counting Implementation Challenges Using An Electron Multiplying Charged-Coupled Device Based Micro-CT System

Purpose: To successfully implement and operate a photon counting scheme on an electron multiplying charged-coupled device (EMCCD) based micro-CT system. Methods: We built an EMCCD based micro-CT system and implemented a photon counting scheme. EMCCD detectors use avalanche transfer registries to multiply the input signal far above the readout noise floor. Due to intrinsic differences in the pixel array, using a global threshold for photon counting is not optimal. To address this shortcoming, we generated a threshold array based on sixty dark fields (no x-ray exposure). We calculated an average matrix and a variance matrix of the dark field sequence. The average matrix was used for the offset correction while the variance matrix was used to set individual pixel thresholds for the photon counting scheme. Three hundred photon counting frames were added for each projection and 360 projections were acquired for each object. The system was used to scan various objects followed by reconstruction using an FDK algorithm. Results: Examination of the projection images and reconstructed slices of the objects indicated clear interior detail free of beam hardening artifacts. This suggests successful implementation of the photon counting scheme on our EMCCD based micro-CT system. Conclusion: This work indicates that it is possible to implement and operate a photon counting scheme on an EMCCD based micro-CT system, suggesting that these devices might be able to operate at very low x-ray exposures in a photon counting mode. Such devices could have future implications in clinical CT protocols. NIH Grant R01EB002873; Toshiba Medical Systems Corp.

60 APPLIED LIFE SCIENCES↗

Characteristic performance evaluation of a photon counting Si strip detector for low dose spectral breast CT imaging

Purpose: The possible clinical applications which can be performed using a newly developed detector depend on the detector's characteristic performance in a number of metrics including the dynamic range, resolution, uniformity, and stability. The authors have evaluated a prototype energy resolved fast photon counting x-ray detector based on a silicon (Si) strip sensor used in an edge-on geometry with an application specific integrated circuit to record the number of x-rays and their energies at high flux and fast frame rates. The investigated detector was integrated with a dedicated breast spectral computed tomography (CT) system to make use of the detector's high spatial and energy resolution and low noise performance under conditions suitable for clinical breast imaging. The aim of this article is to investigate the intrinsic characteristics of the detector, in terms of maximum output count rate, spatial and energy resolution, and noise performance of the imaging system. Methods: The maximum output count rate was obtained with a 50 W x-ray tube with a maximum continuous output of 50 kVp at 1.0 mA. A{sup 109}Cd source, with a characteristic x-ray peak at 22 keV from Ag, was used to measure the energy resolution of the detector. The axial plane modulation transfer function (MTF) was measured using a 67 μm diameter tungsten wire. The two-dimensional (2D) noise power spectrum (NPS) was measured using flat field images and noise equivalent quanta (NEQ) were calculated using the MTF and NPS results. The image quality parameters were studied as a function of various radiation doses and reconstruction filters. The one-dimensional (1D) NPS was used to investigate the effect of electronic noise elimination by varying the minimum energy threshold. Results: A maximum output count rate of 100 million counts per second per square millimeter (cps/mm{sup 2}) has been obtained (1 million cps per 100 × 100 μm pixel). The electrical noise floor was less than 4 keV. The energy resolution measured with the 22 keV photons from a {sup 109}Cd source was less than 9%. A reduction of image noise was shown in all the spatial frequencies in 1D NPS as a result of the elimination of the electronic noise. The spatial resolution was measured just above 5 line pairs per mm (lp/mm) where 10% of MTF corresponded to 5.4 mm{sup −1}. The 2D NPS and NEQ shows a low noise floor and a linear dependence on dose. The reconstruction filter choice affected both of the MTF and NPS results, but had a weak effect on the NEQ. Conclusions: The prototype energy resolved photon counting Si strip detector can offer superior imaging performance for dedicated breast CT as compared to a conventional energy-integrating detector due to its high output count rate, high spatial and energy resolution, and low noise characteristics, which are essential characteristics for spectral breast CT imaging.

60 APPLIED LIFE SCIENCES↗

A calibration of NICMOS Camera 2 for low count rates

NICMOS 2 observations are crucial for constraining distances to most of the existing sample of z>1 SNe Ia. Unlike conventional calibration programs, these observations involve long exposure times and low count rates. Reciprocity failure is known to exist in HgCdTe devices and a correction for this effect has already been implemented for high and medium count rates. However, observations at faint count rates rely on extrapolations. Here instead, we provide a new zero-point calibration directly applicable to faint sources. This is obtained via inter-calibration of NIC2 F110W/F160W with the Wide Field Camera 3 (WFC3) in the low count-rate regime using z∼1 elliptical galaxies as tertiary calibrators. These objects have relatively simple near-IR spectral energy distributions, uniform colors, and their extended nature gives a superior signal-to-noise ratio at the same count rate than would stars. The use of extended objects also allows greater tolerances on point-spread function profiles. We find space telescope magnitude zero points (after the installation of the NICMOS cooling system, NCS) of 25.296 ±0.022 for F110W and 25.803 ±0.023 for F160W, both in agreement with the calibration extrapolated from count rates ≳1000 times larger (25.262 and 25.799). Before the installation of the NCS, we find 24.843 ±0.025 for F110W and 25.498 ±0.021 for F160W, also in agreement with the high-count-rate calibration (24.815 and 25.470). We also check the standard bandpasses of WFC3 and NICMOS 2 using a range of stars and galaxies at different colors and find mild tension for WFC3, limiting the accuracy of the zero points. To avoid human bias, our cross-calibration was “blinded” in that the fitted zero-point differences were hidden until the analysis was finalized.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Next Generation Digital Counting System For Low-Level Tritium Studies (Project Report)

Since the early seventies, SRNL has pioneered low-level tritium analysis using various nuclear counting technologies and techniques. Since 1999, SRNL has successfully performed routine low-level tritium analyses with counting systems based on digital signal processor (DSP) modules developed in the late 1990s. Each of these counting systems are complex, unique to SRNL, and fully dedicated to performing routine tritium analyses of low-level environmental samples. It is time to modernize these systems due to a variety of issues including (1) age, (2) lack of direct replacement electronics modules and (3) advances in digital signal processing and computer technology. There has been considerable development in many areas associated with the enterprise of performing low-level tritium analyses. The objective of this LDRD project was to design, build, and demonstrate a Next Generation Tritium Counting System (NGTCS), while not disrupting the routine low-level tritium analyses underway in the facility on the legacy counting systems. The work involved (1) developing a test bed for building and testing new counting system hardware that does not interfere with our routine analyses, (2) testing a new counting system based on a modern state of the art DSP module, and (3) evolving the low-level tritium counter design to reflect the state of the science.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An alternative calibration method for counting P-32 reactor monitors

Radioactivation of sulfur is a common technique used to measure fast neutron fluences in test and research reactors. Elemental sulfur can be pressed into pellets and used as monitors. The {sup 32}S(n, p) {sup 32}P reaction has a practical threshold of about 3 MeV and its cross section and associated uncertainties are well characterized [1]. The product {sup 32P} emits a beta particle with a maximum energy of 1710 keV [2]. This energetic beta particle allows pellets to be counted intact. ASTM Standard Test Method for Measuring Reaction Rates and Fast-Neutron Fluences by Radioactivation of Sulfur-32 (E265) [3] details a method of calibration for counting systems and subsequent analysis of results. This method requires irradiation of sulfur monitors in a fast-neutron field whose spectrum and intensity are well known. The resultant decay-corrected count rate is then correlated to the known fast neutron fluence. The Radiation Metrology Laboratory (RML) at Sandia has traditionally performed calibration irradiations of sulfur pellets using the {sup 252}Cf spontaneous fission neutron source at the National Inst. of Standards and Technology (NIST) [4] as a transfer standard. However, decay has reduced the intensity of NIST's source; thus lowering the practical upper limits of available fluence. As of May 2010, neutron emission rates have decayed to approximately 3 e8 n/s. In practice, this degradation of capabilities precludes calibrations at the highest fluence levels produced at test reactors and limits the useful range of count rates that can be measured. Furthermore, the reduced availability of replacement {sup 252}Cf threatens the long-term viability of the NIST {sup 252}Cf facility for sulfur pellet calibrations. In lieu of correlating count rate to neutron fluence in a reference field the total quantity of {sup 32}P produced in a pellet can be determined by absolute counting methods. This offers an attractive alternative to extended {sup 252}Cf exposures because it can be performed regardless of the characterization of the exposure environment. Count rates produced by sulfur pellets are correlated to the measured quantity of separated {sup 32}P. A posteriori spectral and cross section determination can be used to correlate the quantity of phosphorus back to a neutron fluence in a reference field. This paper outlines a method for the setup, calibration, and use of the detector systems, {sup 32}P sample preparation, and analysis of the beta spectrum. An uncertainty analysis and comparison to ASTM E265 is also included. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Sensitivity Analysis of Neutron Multiplicity Counting Statistics Using First-Order Perturbation Theory and Application to a Subcritical Plutonium Metal Benchmark

It is frequently important to estimate the uncertainty and sensitivity of measured and computed detector responses in subcritical experiments and simulations. These uncertainties arise from the physical construction of the experiment, uncertainties in the transport parameters, and counting uncertainties. Perturbation theory enables sensitivity analysis (SA) and uncertainty quantification on integral quantities like detector responses. Here the aim of our work is to apply SA to the statistics of subcritical neutron multiplicity counting distributions. Current SA methods have only been applied to mean detector responses and the keff eigenvalue. For multiplicity counting experiments, knowledge of the higher-order counting moments and their uncertainties are essential for a complete SA. We apply perturbation theory to compute the sensitivity of neutron multiplicity counting moments to arbitrarily high order. Each moment is determined by solving an adjoint transport equation with a source term that is a function of the adjoint solutions for lower-order moments. This enables moments of arbitrarily high order to be sequentially determined, and it shows that each moment is sensitive to the uncertainties of all lower-order moments. To close our SA of the moments, we derive forward transport equations that are functions of the forward flux and lower-order moment adjoint fluxes. We verify our calculations for the first three moments by comparison with multiplicity counting measurements of a subcritical plutonium metal sphere. For the first three moments, the most influential parameters are ranked, and the validity of first-order perturbation theory is demonstrated by examining the series truncation error. This enables a detailed SA of subcritical multiplicity counting measurements of fissionable material based on transport theory.

42 ENGINEERING↗