Search NASA⌕ Search

SEARCH · Search NASA

Results for “Coupling reaction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Exploring the notion of space coupling propulsion

All existing methods of space propulsion are based on expelling a reaction mass (propellant) to induce motion. Alternatively, 'space coupling propulsion' refers to speculations about reacting with space-time itself to generate propulsive forces. Conceivably, the resulting increases in payload, range, and velocity would constitute a breakthrough in space propulsion. Such speculations are still considered science fiction for a number of reasons: (1) it appears to violate conservation of momentum; (2) no reactive media appear to exist in space; (3) no 'Grand Uniform Theories' exist to link gravity, an acceleration field, to other phenomena of nature such as electrodynamics. The rationale behind these objectives is the focus of interest. Various methods to either satisfy or explore these issues are presented along with secondary considerations. It is found that it may be useful to consider alternative conventions of science to further explore speculations of space coupling propulsion.

Millis, Marc G.↗

Energetics and kinetics of the prebiotic synthesis of simple organic acids and amino acids with the FeS-H2S/FeS2 redox couple as reductant

The thermodynamics of the FeS-H2S/FeS2 redox couple and a select number of reactions critical to the synthesis of simple carboxylic acids and amino acids have been evaluated as a function of temperature. This thermodynamic evaluation shows that the reducing power of the FeS-H2S/FeS2 redox couple decreases drastically with temperature. By contrast the equilibria describing the reduction of CO2 and the formation of simple carboxylic acids and amino acids require an increasingly higher reducing power with temperature. Given these two opposite trends, the thermodynamic driving force for CO2 reduction and amino acid formation with the FeS-H2S/FeS2 redox couple as reductant diminishes with increasing temperature. An evaluation of the mechanism of CO2 reduction by the FeS-H2S/FeS2 couple suggests that the electron transfer from pyrrhotite to CO2 is hindered by a high activation energy, even though the overall reaction is thermodynamically favorable. By comparison the electron transfer from pyrrhotite to either CS2, CO, or HCOOH are far more facile. This theoretical analysis explains the results of experimental work by Keefe et al. (1995), Heinen and Lauwers (1996) and Huber and Wachtershauser (1997). The implication is that a reaction sequence involving the reduction of CO2 with the FeS-H2S/FeS2 couple as reductant is unlikely to initiate a proposed prebiotic carbon fixation cycle (Wachtershauser, 1988b; 1990b, 1990a, 1992, 1993).

Non-NASA Center↗

Scattering of 42 MeV alpha particles from copper-65

Beams of 42-MeV alpha particles were elastically and inelastically scattered from Cu-65 in an attempt to excite states which may be described in terms of an excited core model. Angular distributions were measured for 17 excited states. Seven of the excited states had angular distributions similar to a core quadrupole excitation and eight of the excited states had angular distributions similar to a core octupole excitation. The excited state at 2.858 MeV had an angular distribution which suggests that it may have results from the particle coupling to a two-phonon core state. An extended particle-core coupling calculation was performed and the predicted energy levels and reduced transition probabilities compared to the experimental data. The low lying levels are described quite well and the wavefunctions of these states explain the large spectroscopic factors measured in stripping reactions. For Cu-65 the coupling of the particle to the core is no larger weak as in the simpler model, and configuration mixing results.

Stewart, W. M.↗

Characterization of reaction kinetics in a porous electrode

A continuum-model approach, analogous to porous electrode theory, was applied to a thin-layer cell of rectangular and cylindrical geometry. A reversible redox couple is assumed, and the local reaction current density is related to the potential through the formula of Hubbard and Anson for a uniformily accessible thin-layer cell. The placement of the reference electrode is also accounted for in the analysis. Primary emphasis is placed on the effect of the solution-phase ohmic potential drop on the voltammogram characteristics. Correlation equations for the peak-potential displacement from E(sup 0 prime) and the peak current are presented in terms of two dimensionless parameters.

Fedkiw, Peter S.↗

Cytometer on a Chip

A cytometer now under development exploits spatial sorting of sampled cells on a microarray chip followed by use of grating-coupled surface-plasmon-resonance imaging (GCSPRI) to detect the sorted cells. This cytometer on a chip is a prototype of contemplated future miniature cytometers that would be suitable for rapidly identifying pathogens and other cells of interest in both field and laboratory applications and that would be attractive as alternatives to conventional flow cytometers. The basic principle of operation of a conventional flow cytometer requires fluorescent labeling of sampled cells, stringent optical alignment of a laser beam with a narrow orifice, and flow of the cells through the orifice, which is subject to clogging. In contrast, the principle of operation of the present cytometer on a chip does not require fluorescent labeling of cells, stringent optical alignment, or flow through a narrow orifice. The basic principle of operation of the cytometer on a chip also reduces the complexity, mass, and power of the associated laser and detection systems, relative to those needed in conventional flow cytometry. Instead of making cells flow in single file through a narrow flow orifice for sequential interrogation as in conventional flow cytometry, a liquid containing suspended sampled cells is made to flow over the front surface of a microarray chip on which there are many capture spots. Each capture spot is coated with a thin (.50-nm) layer of gold that is, in turn, coated with antibodies that bind to cell-surface molecules characteristic of the cell species of interest. The multiplicity of capture spots makes it possible to perform rapid, massively parallel analysis of a large cell population. The binding of cells to each capture spot gives rise to a minute change in the index of refraction at the surface of the chip. This change in the index of refraction is what is sensed in GCSPRI, as described briefly below. The identities of the various species in a sample of cells is spatially encoded in the chip by the pattern of capture spots. The number of cells of a particular species is determined from the magnitude of the GCSPRI signal from that spot. GCSPRI as used here can be summarized as follows: The cytometer chip is fabricated with a diffraction grating on its front surface. The chip is illuminated with a light emitting diode (LED) from the front. By proper choice of grating parameters and of the wavelength and the angle of incidence of a laser beam, laser light can be made to be coupled into an electromagnetic mode that resonates with surface plasmons and thus couples light into surface plasmons. Coupling of light into a surface plasmon at a given location reduces the amount of incident light reflected from that location. A change in the index of refraction at the surface of a capture spot gives rise to a change in the resonance condition. Depending on the specific design, the change in the index of refraction could manifest itself as a brightening or darkening, a change in the wavelength needed to excite the plasmon at a given angle of incidence, or a change in the angle of incidence needed to excite the plasmon at a given wavelength. Whereas a multiwavelength laser system with multichannel detection would be needed to detect multiple species in conventional flow cytometry, it suffices to use an LED and a single detector channel in the GCSPRI approach: this contributes significantly to reductions in cost, complexity, size, mass, and power. GCSPRI cytometer chips could be made of plastic and could be mass-produced cheaply by use of molding and other methods adopted from the manufacture of digital video disks. These methods are amenable to a high degree of miniaturization: such additional features as fluidic channels, reaction chambers, and fluid-coupling ports could readily be incorporated into the chips, without incurring substantial additional costs.

Fernandez, Salvador M.↗

Cytometer on a Chip

A cytometer now under development exploits spatial sorting of sampled cells on a microarray chip followed by use of grating-coupled surface-plasmon-resonance imaging (GCSPRI) to detect the sorted cells. This cytometer on a chip is a prototype of contemplated future miniature cytometers that would be suitable for rapidly identifying pathogens and other cells of interest in both field and laboratory applications and that would be attractive as alternatives to conventional flow cytometers. The basic principle of operation of a conventional flow cytometer requires fluorescent labeling of sampled cells, stringent optical alignment of a laser beam with a narrow orifice, and flow of the cells through the orifice, which is subject to clogging. In contrast, the principle of operation of the present cytometer on a chip does not require fluorescent labeling of cells, stringent optical alignment, or flow through a narrow orifice. The basic principle of operation of the cytometer on a chip also reduces the complexity, mass, and power of the associated laser and detection systems, relative to those needed in conventional flow cytometry. Instead of making cells flow in single file through a narrow flow orifice for sequential interrogation as in conventional flow cytometry, a liquid containing suspended sampled cells is made to flow over the front surface of a microarray chip on which there are many capture spots. Each capture spot is coated with a thin (approximately 50-nm) layer of gold that is, in turn, coated with antibodies that bind to cell-surface molecules characteristic of one the cell species of interest. The multiplicity of capture spots makes it possible to perform rapid, massively parallel analysis of a large cell population. The binding of cells to each capture spot gives rise to a minute change in the index of refraction at the surface of the chip. This change in the index of refraction is what is sensed in GCSPRI, as described briefly below. The identities of the various species in a sample of cells is spatially encoded in the chip by the pattern of capture spots. The number of cells of a particular species is determined from the magnitude of the GCSPRI signal from that spot. GCSPRI as used here can be summarized as follows: The cytometer chip is fabricated with a diffraction grating on its front surface. The chip is illuminated with a light emitting diode (LED) from the front. By proper choice of grating parameters and of the wavelength and the angle of incidence of a laser beam, laser light can be made to be coupled into an electromagnetic mode that resonates with surface plasmons and thus couples light into surface plasmons. Coupling of light into a surface plasmon at a given location reduces the amount of incident light reflected from that location. A change in the index of refraction at the surface of a capture spot gives rise to a change in the resonance condition. Depending on the specific design, the change in the index of refraction could manifest itself as a brightening or darkening, a change in the wavelength needed to excite the plasmon at a given angle of incidence, or a change in the angle of incidence needed to excite the plasmon at a given wavelength. Whereas a multiwavelength laser system with multichannel detection would be needed to detect multiple species in conventional flow cytometry, it suffices to use an LED and a single detector channel in the GCSPRI approach: this contributes significantly to reductions in cost, complexity, size, mass, and power. GCSPRI cytometer chips could be made of plastic and could be mass-produced cheaply by use of molding and other methods adopted from the manufacture of digital video disks. These methods are amenable to a high degree of miniaturization: such additional features as fluidic channels, reaction chambers, and fluid-coupling ports could readily be incorporated into the chips, without incurring substantial additional costs.

Fernandez, Salvador M.↗

Calculation of eddy viscosity in a compressible turbulent boundary layer with mass injection and chemical reaction

The turbulent kinetic energy equation is coupled with boundary layer equations to solve the characteristics of compressible turbulent boundary layers with mass injection and combustion. The Reynolds stress is related to the turbulent kinetic energy using the Prandtl-Wieghardt formulation. When a lean mixture of hydrogen and nitrogen is injected through a porous plate into the subsonic turbulent boundary layer of air flow and ignited by external means, the turbulent kinetic energy increases twice as much as that of noncombusting flow with the same mass injection rate of nitrogen. The magnitudes of eddy viscosity between combusting and noncombusting flows with injection, however, are almost the same due to temperature effects, while the distributions are different. The velocity profiles are significantly affected by combustion. If pure hydrogen as a transpiration coolant is injected into a rocket nozzle boundary layer flow of combustion products, the temperature drops significantly across the boundary layer due to the high heat capacity of hydrogen. At a certain distance from the wall hydrogen reacts with the combustion products, liberating an extensive amount of heat.

Omori, S.↗

A photochemical model of ozone interference effects in laser detection of tropospheric OH

Laser-generated interference in the laser-induced fluorescence detection of tropospheric hydroxyl is addressed by a detailed photochemical model. This phenomenon arises through photolysis of ozone by the detection laser and subsequent reaction of O(1D) with H2O to form OH. The approach is direct time integration of the coupled differential equations describing the pertinent chemical reactions, collisional energy transfer, and photolytic and spectroscopic processes, including an assessment of limitations due to uncertainties in the input parameters. The goal is to use the model to quantitatively design OH detection methods so that the experimental results need not rely on such a model for interpretation. Previously reported measurements of tropospheric OH appear to have been contaminated by ozone interference effects and by optical saturation of the monitoring transition. However, suggested improvements can reduce the problem to interference levels below 200,000 OH molecules/cu cm, permitting measurements useful for testing theories of fast tropospheric photochemistry.

Smith, Gregory P.↗

Convective stability in the presence of a catalytic chemical reaction. I.

A linear analysis of hydrodynamic stability has been applied to a problem in which a fluid mixture is contained between two horizontal planes. One species diffuses to the lower plane where it is destroyed by a rapid exothermic or endothermic catalytic reaction. Results show that important coupling takes place between thermal and concentration fields. This coupling gives rise to unusual stabilizing or destabilizing effects, depending upon the value of Lewis number. Several examples are discussed. It is also shown how the results can be applied to other problems involving heat and mass transfer.

Wankat, P. C.↗

Experimental and theoretical studies of NO/x/ formation in a jet-stirred combustor.

As an approach to testing kinetic models which couple NO formation to combustion reactions, a jet-stirred combustor was used to study NO(x) formation under kinetically controlled combustion conditions. The experimental data were compared with kinetic calculations for a well-stirred reactor. The agreement between theory and experiment was quite good for the combustion of hydrogen/air and carbon monoxide/air, for which detailed mechanisms were used. A quasi-global mechanism for the combustion of propane/air resulted in substantial underprediction of NO(x) formation.

Engleman, V. S.↗

Stratospheric free chlorine measured by balloon-borne in situ resonance fluorescence

Eight balloon-borne in situ measurements of ClO in the stratosphere are analyzed and are compared with recent model calculations. While the use of in situ stratospheric studies of free radicals to test models by comparing observed and predicted concentration profiles is essential for a prognosis of changes in stratospheric ozone, resulting from future changes in stratospheric ozone, such studies provide only limited insight into the nature of stratospheric photochemistry, because natural variability and the large number of fast reactions which compete in the coupling among the key radicals frustrate a detailed comparison between a mean distribution provided by the models and an instantaneous distribution provided by a single observation.

Anderson, J. G.↗

A mass spectrometric study of the simultaneous reaction mechanism of TMIn and PH3 to grow InP

The reaction mechanisms for the growth of InP from various mixtures of trimethyl indium (TMIn) and PH3 by OMVPE were investigated using mass spectrometry and a D2 ambient for isotopic labeling of the reaction products. It was found that, whereas TMIn alone pyrolyzes homogeneously, forming CH3D, and PH3 alone pyrolyzes heterogeneously, producing H2, the pyrolysis reactions of TMIn and PH3 together are completely different. The pyrolysis temperatures of both TMIn and PH3 are reduced (by 50 C for TMIn and 225 C for PH3), and the sole product is CH4 at high values of the PH3/TMIn ratio. The pyrolysis reaction is shown to be coupled (as evidenced by the equal depletion of TMIn and PH3 from the vapor) and, at temperatures below 400 C, heterogeneous.

Buchan, N. I.↗

Multigrid Method for Modeling Multi-Dimensional Combustion with Detailed Chemistry

A highly accurate and efficient numerical method is developed for modeling 3-D reacting flows with detailed chemistry. A contravariant velocity-based governing system is developed for general curvilinear coordinates to maintain simplicity of the continuity equation and compactness of the discretization stencil. A fully-implicit backward Euler technique and a third-order monotone upwind-biased scheme on a staggered grid are used for the respective temporal and spatial terms. An efficient semi-coarsening multigrid method based on line-distributive relaxation is used as the flow solver. The species equations are solved in a fully coupled way and the chemical reaction source terms are treated implicitly. Example results are shown for a 3-D gas turbine combustor with strong swirling inflows.

Zheng, Xiaoqing↗

Chemical Vapor Deposition at High Pressure in a Microgravity Environment

In this paper we present an evaluation of critical requirements of organometallic chemical vapor deposition (OMCVD) at elevated pressure for a channel flow reactor in a microgravity environment. The objective of using high pressure is to maintain single-phase surface composition for materials that have high thermal decomposition pressure at their optimum growth temperature. Access to microgravity is needed to maintain conditions of laminar flow, which is essential for process analysis. Based on ground based observations we present an optimized reactor design for OMCVD at high pressure and reduced gravity. Also, we discuss non-intrusive real-time optical monitoring of flow dynamics coupled to homogeneous gas phase reactions, transport and surface processes. While suborbital flights may suffice for studies of initial stages of heteroepitaxy experiments in space are essential for a complete evaluation of steady-state growth.

McCall, Sonya↗

Numerical Model of Flame Spread Over Solids in Microgravity: A Supplementary Tool for Designing a Space Experiment

The recently developed numerical model of concurrent-flow flame spread over thin solids has been used as a simulation tool to help the designs of a space experiment. The two-dimensional and three-dimensional, steady form of the compressible Navier-Stokes equations with chemical reactions are solved. With the coupled multi-dimensional solver of the radiative heat transfer, the model is capable of answering a number of questions regarding the experiment concept and the hardware designs. In this paper, the capabilities of the numerical model are demonstrated by providing the guidance for several experimental designing issues. The test matrix and operating conditions of the experiment are estimated through the modeling results. The three-dimensional calculations are made to simulate the flame-spreading experiment with realistic hardware configuration. The computed detailed flame structures provide the insight to the data collection. In addition, the heating load and the requirements of the product exhaust cleanup for the flow tunnel are estimated with the model. We anticipate that using this simulation tool will enable a more efficient and successful space experiment to be conducted.

Shih, Hsin-Yi↗