Validation of Gas-Liquid Sharp Interface Model in Loci-Stream for Propellant Tank Self-pressurization under Normal Gravity

Deep space missions require advances in cryogenic fluid management (CFM) for long term storage of propellants. One of the important phenomena is self-pressurization due to heat leakages into the tank. Managing self-pressurization is one of the key technologies for deep space exploration and long-term space missions. The complex interactions involving natural convection, thermal gradients, turbulence, and phase change near the gas-liquid interface cannot be modeled using reduced order or nodal analysis models, and 3-D CFD analyses are necessary to fully characterize the dynamics. CFD analyses pose their own difficulties. The requisite CFD tool to tackle this problem need to be modular with the ability to incorporate various physics models, efficient, and computationally scalable for simulating flight size tanks. In this paper, we discuss modeling approach for self-pressurization in situations where the liquid interface is static and validate NASA MSFC's Loci-Stream CFD solver for predicting self-pressurization in a test tank in normal gravity. This tank was designed to capture quantifiable and accurate data for understanding various two-phase fluid phenomena and to validate modeling tools. Specifically, we demonstrate the capability of the Loci-Stream solver with a two-phase sharp-interface treatment to predict self-pressurization of a tank with an unperturbed gas-liquid interface. This validation highlights the reliability of our modeling approach and our solver to serve as a design and analysis tool for NASA's CFM application needs.

cryogenic fluid management↗

Validation of Gas-Liquid Sharp Interface Model in Loci-Stream for Propellant Tank Self-pressurization under Normal Gravity

Deep space missions require advances in cryogenic fluid management (CFM) for long term storage of propellants. One of the important phenomena is self-pressurization due to heat leakages into the tank. Managing self-pressurization is one of the key technologies for deep space exploration and long-term space missions. The complex interactions involving natural convection, thermal gradients, turbulence, and phase change near the gas-liquid interface cannot be modeled using reduced order or nodal analysis models, and 3-D CFD analyses are necessary to fully characterize the dynamics. CFD analyses pose their own difficulties. The requisite CFD tool to tackle this problem need to be modular with the ability to incorporate various physics models, efficient, and computationally scalable for simulating flight size tanks. In this paper, we discuss modeling approach for self-pressurization in situations where the liquid interface is static and validate NASA MSFC’s Loci-Stream CFD solver for predicting self-pressurization in a test tank in normal gravity. This tank was designed to capture quantifiable and accurate data for understanding various two-phase fluid phenomena and to validate modeling tools. Specifically, we demonstrate the capability of the Loci-Stream solver with a two-phase sharp-interface treatment to predict self-pressurization of a tank with an unperturbed gas-liquid interface. This validation highlights the reliability of our modeling approach and our solver to serve as a design and analysis tool for NASA’s CFM application needs.

cryogenic fluid management↗

Temperature Stratification in a Cryogenic Fuel Tank

A reduced dynamical model describing temperature stratification effects driven by natural convection in a liquid hydrogen cryogenic fuel tank has been developed. It accounts for cryogenic propellant loading, storage, and unloading in the conditions of normal, increased, and micro- gravity. The model involves multiple horizontal control volumes in both liquid and ullage spaces. Temperature and velocity boundary layers at the tank walls are taken into account by using correlation relations. Heat exchange involving the tank wall is considered by means of the lumped-parameter method. By employing basic conservation laws, the model takes into consideration the major multi-phase mass and energy exchange processes involved, such as condensation-evaporation of the hydrogen, as well as flows of hydrogen liquid and vapor in the presence of pressurizing helium gas. The model involves a liquid hydrogen feed line and a tank ullage vent valve for pressure control. The temperature stratification effects are investigated, including in the presence of vent valve oscillations. A simulation of temperature stratification effects in a generic cryogenic tank has been implemented in Matlab and results are presented for various tank conditions.

stratification↗

Solid-State Thermodynamic Vent System for Control of Cryogenic Propellants

A Solid-State Thermodynamic Vent System (STVS) is a novel Cryogenic Fluid Management (CFM) technology for spacecraft cryogenic propellant tanks that may reduce boiloff while providing greater control over the propellent condition. By exploiting the vacuum-induced cryocooling potential of cryogen-saturated silica aerogel material, an internal STVS heat exchanger expels some sacrificial cryogenic propellant to the vacuum of space to produce cooling within the storage tank. This cooling is transferred directly to the stored fluid, thereby reducing boiloff and increasing hold times. The primary STVS project objective was to design and build a bespoke STVS heat exchanger that employed aerogel blanket material and perform a ground demonstration of the technology using liquid nitrogen (LN2) as the cryogenic propellant. This demonstration aimed to prove that an STVS can have a positive influence on the tank boiloff, shown through a reduction in mass flow rate out of the system during operation, and exercise control over the tank pressure. Testing proved the effectiveness of the concept by reducing the LN2 boiloff rate and tank pressure by roughly 70% and 77% respectively during a single pump-down cycle, which sacrificed around 1.8 kg of propellant.

Propellant Production↗

Modeling a Transient Pressurization with Active Cooling Sizing Tool

As interest in the area of in-space zero boil-off cryogenic propellant storage develops, the need to visualize and quantify cryogen behavior during ventless tank self-pressurization and subsequent cool-down with active thermal control has become apparent. During the course of a mission, such as the launch ascent phase, there are periods that power to the active cooling system will be unavailable. In addition, because it is not feasible to install vacuum jackets on large propellant tanks, as is typically done for in-space cryogenic applications for science payloads, instances like the launch ascent heating phase are important to study. Numerous efforts have been made to characterize cryogenic tank pressurization during ventless cryogen storage without active cooling, but few tools exist to model this behavior in a user-friendly environment for general use, and none exist that quantify the marginal active cooling system size needed for power down periods to manage tank pressure response once active cooling is resumed. This paper describes the Transient pressurization with Active Cooling Tool (TACT), which is based on a ventless three-lump homogeneous thermodynamic self-pressurization model1 coupled with an active cooling system estimator. TACT has been designed to estimate the pressurization of a heated but unvented cryogenic tank, assuming an unavailable power period followed by a given cryocooler heat removal rate. By receiving input data on the tank material and geometry, propellant initial conditions, and passive and transient heating rates, a pressurization and recovery profile can be found, which establishes the time needed to return to a designated pressure. This provides the ability to understand the effect that launch ascent and unpowered mission segments have on the size of an active cooling system. A sample of the trends found show that an active cooling system sized for twice the steady state heating rate would results in a reasonable time for tank pressure recovery with ZBO of a liquid oxygen propellant tank.

Guzik, Monica C.↗

Transient Convection Due to Imposed Heat Flux: Application to Liquid-Acquisition Devices

A model problem is considered that addresses the effect of heat load from an ambient laboratory environment on the temperature rise of liquid nitrogen inside an enclosure. This model has applications to liquid acquisition devices inside the cryogenic storage tanks used to transport vapor-free propellant to the main engine. We show that heat loads from Q = 0.001 to 10 W, with corresponding Rayleigh numbers from Ra = 109 to 1013, yield a range of unsteady convective states and temperature rise in the liquid. The results show that Q = 1 to 10 W (Ra = 1012 to 1013) yield temperature distributions along the enclosure height that are similar in trend to experimental measurements. Unsteady convection, which shows selfsimilarity in its planforms, is predicted for the range of heat-load conditions. The onset of convection occurs from a free-convection-dominated base flow that becomes unstable against convective instability generated at the bottom of the enclosure while the top of the enclosure is convectively stable. A number of modes are generated with small-scale thermals at the bottom of the enclosure in which the flow selforganizes into two symmetric modes prior to the onset of the propagation of the instability. These symmetric vertical modes transition to asymmetric modes that propagate as a traveling-wave-type motion of convective modes and are representative of the asymptotic convective state of the flow field. Intense vorticity production is created in the core of the flow field due to the fact that there is shear instability between the vertical and horizontal modes. For the higher Rayleigh numbers, 1012 to 1013, there is a transition from a stationary to a nonstationary response time signal of the flow and temperature fields with a mean value that increases with time over various time bands and regions of the enclosure.

Duval, Walter M. B.↗

Validation of Universal Cryogenic Flow Boiling Correlations in Thermal Desktop for Liquid Hydrogen

Developing accurate models of two-phase cryogenic flow will reduce risk and reduce margins for future NASA vehicles such as the Nuclear Thermal Propulsion (NTP) system. Currently there is a need for more accurate, direct cryogenic data-anchored models for various boiling and two-phase phenomena. The focus of the current work is on modeling steady state cryogenic flow boiling in the transfer line that connects a propellant storage tank to an engine or customer receiver tank. This paper presents Thermal Desktop model validation results against several historical liquid hydrogen (LH2) heated tube experiments that cover a wide range of inlet conditions, mass flux, and heat flux. New universal cryogenic flow boiling correlations were recently developed and anchored to the largest cryogenic flow boiling database assembled in the world to-date. The new universal correlations are patched together and implemented into Thermal Desktop to compare model performance against the built-in flow boiling correlations. Axial wall temperature predictions as a function of preponderant parameters like heat flux, mass flux, inlet pressure, inlet quality, tube diameter, etc. using the two sets of flow boiling correlations are compared against the experimental data. Overall, the Thermal Desktop model with the new universal cryogenic flow boiling correlations demonstrates an improvement in predictive performance over the Thermal Desktop model using built-in correlations for both wall temperature and location of critical heat flux compared to the data for LH2 flow boiling in heated tubes.

Cryogenic Propellant Transfer↗

Validation of Universal Cryogenic Flow Boiling Correlations in Thermal Desktop for Liquid Hydrogen

Developing accurate models of two-phase cryogenic flow will reduce risk and reduce margins for future NASA vehicles such as the Nuclear Thermal Propulsion (NTP) system. Currently there is a need for more accurate, direct cryogenic data-anchored models for various boiling and two-phase phenomena. The focus of the current work is on modeling steady state cryogenic flow boiling in the transfer line that connects a propellant storage tank to an engine or customer receiver tank. This paper presents Thermal Desktop model validation results against several historical liquid hydrogen (LH2) heated tube experiments that cover a wide range of inlet conditions, mass flux, and heat flux. New universal cryogenic flow boiling correlations were recently developed and anchored to the largest cryogenic flow boiling database assembled in the world to-date. The new universal correlations are patched together and implemented into Thermal Desktop to compare model performance against the built-in flow boiling correlations. Axial wall temperature predictions as a function of preponderant parameters like heat flux, mass flux, inlet pressure, inlet quality, tube diameter, etc. using the two sets of flow boiling correlations are compared against the experimental data. Overall, the Thermal Desktop model with the new universal cryogenic flow boiling correlations demonstrates an improvement in predictive performance over the Thermal Desktop model using built-in correlations for both wall temperature and location of critical heat flux compared to the data for LH2 flow boiling in heated tubes.

cryogenic propellant transfer↗

Validation & Verification of CFD Models for Cryogenic Fluid Management of Propellant Tanks in Space

This article describes the need and the strategy for CFD model development, validation, and verification for Cryogenic Fluid Management (CFM) of Propellant Tanks in Space. It describes the type of CFD models that must be developed to address the future needs of Space CFM. It also discusses the two classes of experiments currently used to validate the fidelity of the CFD models. These two experiment classes are: (a) the small-scale simulant fluid science experiments that are equipped with scientific diagnostics to elucidate the underlying two-phase fluid physics of the CFM processes; and (b) the large-scale cryogenic experiments that assess the engineering performance of the propellant tank for storage and transfer. The current status of the CFD model development and validation is briefly assessed by presenting examples of segregated two-phase flow problems that have been successfully modeled. The future model development directions for CFM situations involving more complex interpenetrating phases are also defined.

Cryogenic Fluid Management↗

Hybrid Thermal Control Testing of a Cryogenic Propellant Tank

This report presents the experimental results of a hybrid thermal control system, one that integrates a passive system (multi-layer insulation) with an active system (a mechanical cyrocooler) applied to cryogenic propellant storage. These experiments were performed on a 1.39 m diameter spherical propellant tank filled with LH2 while installed in an evacuated chamber. The tank heat transfer to the cryocooler was accomplished with a condenser installed in the ullage of the tank and mated to the second stage of the cooler, and by conduction, through copper leaves mated to the first stage of the cooler. The first hybrid system test was performed with both the condenser and the leaves, a configuration that had excess capacity to remove the heat entering the tank; the second test was performed with only the condenser, with a capacity closely matched to the tank heating rate. In both of these tests, the goal of zero boil-off was achieved.

Plachta, David W.↗

Fuel Cell Systems for First Lunar Outpost: Reactant Storage Options

A Lunar Surface Power Working Group was formed to review candidate systems for providing power to the first lunar outpost habitat. The working group concluded that the most attractive candidate included a photovoltaic unit, a fuel cell, a regenerator to recycle the reactants, and storage of oxygen and hydrogen gases. Most of the volume (97 percent) and weight (64 percent) are taken up by the reactants and their storage tank. The large volume is difficult to accommodate, and therefore, the working group explored ways of reducing the volume. An alternative approach to providing separate high pressure storage tanks is to use two of the descent stage propellant storage tanks, which would have to be wrapped with graphite fibers to increase their pressure capability. This saves 90 percent of the volume required for storage of fuel cell reactants. Another approach is to use the descent storage propellant tanks for storage of the fuel cell reactants as cryogenic liquids, but his requires a gas liquefication system, increases the solar array by 40 percent, and increases the heat rejection rate by 170 percent compared with storage of reactants as high pressure gases. For a high power system (greater than 20 kW) the larger energy storage requirements would probably favor the cryogenic storage option.

Nelson, P. A.↗

Zero Boiloff Storage of Cryogenic Propellants Achieved at Lewis' Supplemental Multilayer Insulation Research Facility

Tests conducted at the NASA Lewis Research Center's Supplemental Multilayer Insulation Research Facility (SMIRF) demonstrated that a hybrid thermal control system could eliminate boiloff of cryogenic propellants. This is significant because of the substantial mass and cost savings that could be achieved for any long-duration space mission that requires cryogenic propellants. With long-duration cryogenic storage, propellants will boil off because of the environmental heating of the tank. To accommodate these losses, extra propellant is required along with larger propellant tanks. Analysis of Mars mission scenarios using space-transfer cryogenic stages showed that significant savings in propellant mass and tank size could be achieved if it were possible to eliminate or significantly reduce propellant boiloff. Engineers and technicians at NASA Lewis designed, built, and tested a hybrid thermal control system to eliminate or significantly reduce cryogenic propellant boiloff. The system consists of an active cryocooling system using a cryocooler in addition to the traditional passive thermal insulation, as shown in the photo.

Plachta, David W.↗

Solid-State Thermodynamic Vent System (STVS) for Control of Cryogenic Propellants

A Solid-State Thermodynamic Vent System (STVS) is a novel Cryogenic Fluid Management (CFM) technology for spacecraft cryogenic propellant tanks that may reduce boiloff while providing greater control over the propellant condition. By exploiting the vacuum-induced cryocooling (VIC) potential of cryogen-saturated silica aerogel material, an internal STVS heat exchanger (HX) can expel some sacrificial cryogenic propellant to the vacuum of space to produce cooling within the storage tank. This cooling is transferred directly to the stored fluid, thereby reducing boiloff and increasing hold times. Testing proved the effectiveness of the concept by reducing the liquid nitrogen (LN 2 ) boiloff rate and tank pressure by roughly 70% and 77%, respectively, during a single pump-down cycle, which sacrificed around 1.8 kg of propellant.

Cryogenic Fluid↗

Thermoplastic Matrix Composite Design for Cryotanks Using Multiscale Modeling and Bayesian Optimization

Designing lightweight, robust cryogenic storage tanks is critical for future launch vehicles, in-space propellant storage, and hydrogen powered aircraft. This work presents a multiscale modeling and Bayesian optimization framework for the design of thermoplastic matrix composite cryotanks. Molecular dynamics simulations are first used to determine temperature-dependent constituent properties for candidate thermoplastic matrices, which are homogenized to the lamina scale using NASA’s Multiscale Analysis Tool (NASMAT). These lamina properties, in combination with laminate family generation rules, are evaluated in HyperX structural optimization software to identify stacking sequences that meet all cryogenic load requirements. A Bayesian optimization framework is applied, with HyperX in the loop (via the HyperX API) to efficiently search across material and laminate design variables, yielding an optimized cryotank configuration with significant reductions in design cycle time compared to exhaustive search approaches.

thermoplastics↗

Zero-Boil-Off Tank (ZBOT) Experiment: Ground-Based Validation of Self-Pressurization and Pressure Control Two-Phase CFD Model

Integral to all phases of NASA's projected space and planetary expeditions is affordable and reliable cryogenic fluid storage for use in propellant or life support systems. Cryogen vaporization due to heat leaks into the tank from its surroundings and support structure can cause self-pressurization relieved through venting. This has led to a desire to develop innovative pressure control designs based on mixing of the bulk tank fluid together with some form of active or passive cooling to allow storage of the cryogenic fluid with zero or reduced boil-off. The Zero-Boil-Off Tank (ZBOT) Experiments are a series of small scale tank pressurization and pressure control experiments aboard the International Space Station (ISS) that use a transparent volatile simulant fluid in a transparent sealed tank to delineate various fundamental fluid flow, heat and mass transport, and phase change phenomena that control storage tank pressurization and pressure control in microgravity. The hardware for ZBOT-1 flew to ISS on the OA-7 flight in April 2017 and operations are planned to begin in September 2017, encompassing more than 90 tests. This paper presents preliminary results from ZBOT's ground-based research delineating both pressurization and pressure reduction trends in the sealed test tank. Tank self-pressurization tests are conducted under three modes: VJ heating, strip heating and simultaneous VJ and strip heating in attempt to simulate heat leaks from the environment, the support structure and both. The jet mixing pressure control studies are performed either from an elevated uniform temperature condition or from thermally stratified conditions following a self-pressurization run. Jet flow rates are varied from 2-25 cm/s spanning a range of jet Re number in laminar, transitional, and turbulent regimes and a range of Weber numbers covering no ullage penetration, partial penetration and complete ullage penetration and break-up (only in microgravity). Numerical prediction of a two-phase CFD model are compared to experimental 1g results to both validate the model and also indicate the effect of the residual non-condensable gas on evolution of pressure and temperature distributions in the tank during pressurization and pressure control.

microgravity evaporation condensatio↗

Polymer-Layered Silicate Nanocomposites for Cryotank Applications

Previous composite cryotank designs have relied on the use of conventional composite materials to reduce microcracking and permeability. However, revolutionary advances in nanotechnology derived materials may enable the production of ultra-lightweight cryotanks with significantly enhanced durability and damage tolerance, as well as reduced propellant permeability. Layered silicate nanocomposites are especially attractive in cryogenic storage tanks based on results that have been reported for epoxy nanocomposite systems. These materials often exhibit an order of magnitude reduction in gas permeability when compared to the base resin. In addition, polymer-silicate nanocomposites have been shown to yield improved dimensional stability, strength, and toughness. The enhancement in material performance of these systems occurs without property trade-offs which are often observed in conventionally filled polymer composites. Research efforts at NASA Glenn Research Center have led to the development of epoxy-clay nanocomposites with 70% lower hydrogen permeability than the base epoxy resin. Filament wound carbon fiber reinforced tanks made with this nanocomposite had a five-fold lower helium leak rate than the corresponding tanks made without clay. The pronounced reduction observed with the tank may be due to flow induced alignment of the clay layers during processing. Additionally, the nanocomposites showed CTE reductions of up to 30%, as well as a 100% increase in toughness.

Miller, Sandi G.↗

Modeling and Analysis of Chill and Fill Processes for the EDU Tank

NASA's future missions may require long-term storage and transfer of cryogenic propellants. The Engineering Development Unit (EDU), a NASA in-house effort supported by both Marshall Space Flight Center (MSFC) and Glenn Research Center (GRC), is a Cryogenic Fluid Management (CFM) test article that primarily serves as a manufacturing pathfinder and a risk reduction task for a future CFM payload. The EDU test article, comprises a flight like tank, internal components, insulation, and attachment struts. The EDU is designed to perform integrated passive thermal control performance testing with liquid hydrogen in a space-like vacuum environment. A series of tests, with liquid hydrogen as a testing fluid, was conducted at Test Stand 300 at MSFC during summer of 2014. The objective of this effort was to develop a thermal/fluid model for evaluating the thermodynamic behavior of the EDU tank during the chill and fill processes. Generalized Fluid System Simulation Program (GFSSP), an MSFC in-house general-purpose computer program for flow network analysis, was utilized to model and simulate the chill and fill portion of the testing. The model contained the liquid hydrogen supply source, feed system, EDU tank, and vent system. The modeling description and comparison of model predictions with the test data will be presented in the final paper.

Hedayat, A.↗