Search NASA⌕ Search

SEARCH · Search NASA

Results for “DATA READOUT SYSTEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Real-time data reduction at 100 Tbps: Challenge and opportunity for AI-based data reduction for next-generation large-scale nuclear physics collider experiment

The modern large-scale nuclear physics (NP) experiments in high-energy particle colliders utilize streaming-readout electronics to digitize detector response at O(100) Tbps bandwidth. Prominent examples at Brookhaven National Lab (BNL) include the sPHENIX experiment at Relativistic Heavy Ion Collider (RHIC), which is under construction, and the experiments proposed for the Electron-Ion Collider (EIC), planned for the 2030s . One of the main challenges for these streaming readout systems is to manage the data rate with sufficient data reduction in real time so the end-data fit persistent storage for offline analysis, which is typically at O(1000) times smaller and O(100) Gbps. Such data reduction traditionally is achieved via real-time high level triggers, which select and save a small subset of collisions of interest. Although triggering is applicable to high energy collider experiments such as those at the Large Hardron Collider at CERN, it is insufficient for these nuclear physics experiments which study diverse collision topologies. And traditional triggering approach is inefficient to preserve the max information harvested from the operation of colliders that costs O(100)M per year to DOE. Meanwhile, in recent years, ML-based high-throughput data reduction has emerged as a promising approach to efficiently preserve max information for a given space of persistent storage, e.g. via AI data compression, feature extraction, and noise filtering.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

ML–Enabled FPGA Framework for Fast Quantum State Discrimination in Mid-Circuit Measurement Regimes

Accurate and low-latency quantum state discrimination is essential for protocols involving mid-circuit measurement (MCM) and conditional feed-forward. In superconducting quantum systems, conventional readout pipelines transfer measurement data to host processors for post-processing, introducing millisecond-scale delays that far exceed qubit coherence times. To overcome this bottleneck, we present an in-situ machine learning (ML) inference engine implemented on an FPGA for real-time quantum state discrimination. Our design performs inference directly on digitized readout signals with 40 ns latency, supports both qubit and qutrit readout, and enables conditional operations without host-side intervention. This capability is critical for MCM and for feedback-driven protocols such as quantum error correction. We validate the system on superconducting transmon hardware, demonstrating robust discrimination fidelity across multiple qubit and qutrit channels. We further demonstrate conditional qutrit logic driven by FPGA-resident classification, highlighting the potential of low-latency ML-on-FPGA control for NISQ applications and scalable fault-tolerant quantum computing.

Vora, Neel [Lawrence Berkeley National Laboratory ↗

A novel integrated time-resolved array avalanche photodiode detection system for nuclear resonant scattering measurements

Here, the nuclear resonant scattering (NRS) experiment requires photon-counting detectors with high time resolution, short dead time, large dynamic range, low noise, and large detection area. An 8-channel avalanche photodiode (APD) array detector system with high integrity, flexibility, and reliability has been developed to adapt to the demands of NRS experiments. The detector system mainly consists of four key parts: (i) an array-APD sensor, (ii) 8-channel integrated fast preamplifiers, (iii) the time-to-digital converter readout electronics, and (iv) a data acquisition system and EPICS support software. Remarkably, the system exhibits a time resolution of better than 500 ps and has a sufficiently low noise level, allowing for the lowest detection energy threshold of 4 keV. The performance of the new array-APD system as well as its real application in nuclear forward scattering (NFS) and nuclear resonant inelastic x-ray scattering (NRIXS) experiments was tested in two synchrotron facilities. With the new system, the NFS signal very close to the prompt electronic scattering signal can be extracted. Thanks to the customized EPICS-areaDetector-based control software, NRIXS spectra can be readily measured with time and energy information of the NRIXS signal stored in the raw data, which is promising for developing NRIXS data analysis in the time domain. The array-APD detector can be deployed for nuclear resonant scattering experiments at various synchrotron radiation facilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Operations manual: On Site Monitor (OSM), solar heating and cooling systems

The on-site monitor is a portable device which, when connected to a solar system site data acquisition subsystem; allows readouts of clock and sensor data in voltage or engineering units at instrumented solar heating and cooling sites. The unit is described and procedures for its proper operation are presented.

Source record↗

Electronic readout systems for microchannel plates

The modes of operation of position-sensitive electronic readout systems which use high-gain microchannel plate (MCP) electron multipliers are described, and their performance characteristics, along with those of the MCP, are compared. Among the structures presented are the wedge-and-strip, Codacon, and multilayer coincidence-anode MAMA (Multimode Microchannel Array) arrays. Spatial resolution of 25 x 25 sq microns (coincidence anode arrays) is achieved with an array format of 256 x 1024 pixels. On the basis of the performance data it is concluded that the readout systems using only conducting electrodes offer the best performance characteristics.

Timothy, J. G.↗

SAMPA Based Streaming Readout Data Acquisition Prototype

We have assembled a small-scale streaming data acquisition system based on the SAMPA front-end ASIC. The 32-channel SAMPA chip was designed for the high-luminosity upgrade of the ALICE Time Projection Chamber (TPC) detector at the CERN Large Hadron Collider. The goals of the prototype system are to determine if the SAMPA chip is appropriate for use in detector systems at Jefferson Lab, and to gain experience with the hardware and software required to deploy streaming data acquisition systems in nuclear physics experiments. The 800 channel system is composed of components used in the ALICE TPC data acquisition upgrade. Five front-end cards (FEC) support five SAMPA chips each. SAMPA data streams on an FEC are concentrated into two high-speed (4.48 Gb/s) serial data streams by a pair Gigabit Transceiver ASICs (GBTx). These ten streams (44.8 Gb/s) are transmitted from the FECs over fibers to a PCIe based readout unit. The FPGA engine on the readout unit compresses data for transmission to a server via 100 Gb ethernet. Components on the FECs are radiation tolerant. High data rates can be handled. The system is by design scalable and thus provides a functional prototype for high-rate streaming readout at Jefferson Lab and the future Electron Ion Collider. We have made fundamental measurements (noise, linearity, time resolution) on the SAMPA ASIC. We have also coupled the readout system to a small Gas Electron Multiplier (GEM) detector and have studied its response to cosmic rays. A beam test of the system is planned.

ABBOTT, David↗

Advanced data readout technique for Multianode Position Sensitive Photomultiplier Tube applicable in radiation imaging detectors

Most of the best performing PSPMT tubes from Hamamatsu and Burle are designed with a pad-matrix anode layout. However, for obtaining a high resolution, a small-sized anode photomultiplier tubes are preferable; these tubes may have 64, 256 or 1024 anodes per tube. If the tubes are used in array to get a larger area detector, the number of analog channels may range from hundreds to thousands. Multichannel analog readout requires special electronics ICs, ASICs etc., which are attached to multichannel DAQ system. As a result, the data file and data processing time will be increased. Therefore, this readout could not be performed in a small project. Usually, most of radiation imaging applications allow the use of analog data processing in front-end electronics, significantly reducing the number of the detector's output lines to data acquisition without reducing the image quality. The idea of pad-matrix decoupling circuit with gain correction was invented and intensively tested in JLab. Several versions of PSPMT readout electronics were produced and studied. All developments were done and optimized specifically for radiation imaging projects. They covered high resolution SPECT, high speed PET, fast neutron imaging, and single tube and multi tube array systems. This paper presents and discusses the summary of the observed results in readout electronics evaluation with different PSPMTs and radiation imaging systems, as well as the advantages and limitations of the developed approach to radiation imaging detectors readout.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The ADAQ framework: An integrated toolkit for data acquisition and analysis with real and simulated radiation detectors

Here, the ADAQ framework is a collection of software tools that is designed to streamline the acquisition and analysis of radiation detector data produced in modern digital data acquisition (DAQ) systems and in Monte Carlo detector simulations. The purpose of the framework is to maximize user scientific pro-ductivity by minimizing the effort and expertise required to fully utilize radiation detectors in a variety of scientific and engineering disciplines. By using a single set of tools to span the real and simulation domains, the framework eliminates redundancy and provides an integrated workflow for high-fidelity comparison between experimental and simulated detector performance. Built on the ROOT data analysis framework, the core of the ADAQ framework is a set of Cþþ and Python libraries that enable high-level control of digital DAQ systems and detector simulations with data stored into standardized binary ROOT files for further analysis. Two graphical user interface programs utilize the libraries to create powerful tools: ADAQAcquisition handles control and readout of real-world DAQ systems and ADAQAnalysis provides data analysis and visualization methods for experimental and simulated data. At present, the ADAQ framework supports digital DAQ hardware from CAEN S.p.A. and detector simulations performed in Geant4; however, the modular design will facilitate future extension to other manufacturers and simulation platforms.

detector simulation↗

An 82 to 84 percent efficient, small size, 2 and 4 stage depressed collector for octave bandwidth high performance TWT's

Improvements were carried out on a TWT (traveling wave tube) for use in EMC (electronic countermeasure) systems by applying MDC (multi-stage depressed collector) and spent-beam refocusing techniques. The MDC geometric design consists of six collecting elements (electrodes) at ground and cathode potentials operating in 2 or 4 stage configuration. The refocusing system designed allows a controlled beam expansion to the point that space charge becomes negligible at the MDC entrance. Simultaneously, the standard deviation of the radial velocity (angular spread) is reduced. This system provides an analog real time readout of P(recovered). Data on all tests is obtained with an automated data acquisition system.

Kosmahl, H.↗

JPSS Science Data Services for the Direct Readout Community

The Suomi National Polar-orbiting Partnership (S-NPP) and Joint Polar Satellite System (JPSS) High Rate Data (HRD) link provides Direct Broadcast data to users in real-time, utilizing their own remote field terminals. The Field Terminal Support (FTS) provides the resources needed to support the Direct Readout communities by providing software, documentation, and periodic updates to enable them to produce data products from SNPP and JPSS. The FTS distribution server will also provide the necessary ancillary and auxiliary data needed for processing the broadcasts, as well as making orbital data available to assist in locating the satellites of interest. In addition, the FTS provides development support for the algorithm and software through GSFC Direct Readout Laboratory (DRL) International Polar Orbiter Processing Package (IPOPP) and University of Wisconsin (UWISC) Community Satellite Processing Package (CSPP), to enable users to integrate the algorithms into their remote terminals. The support the JPSS Program provides to the institutions developing and maintaining these two software packages, will demonstrate the ability to produce ready-to-use products from the HRD link and provide risk reduction effort at a minimal cost. This paper discusses the key functions and system architecture of FTS.

Data Processing↗

Development of a Data Acquisition System for Kinetic Inductance Detectors: Wide Dynamic Range and High Sampling Rate for Astronomical Observation

Microwave kinetic inductance detectors have a variety of potential applications in astronomical observations. We built a data acquisition system for kinetic inductance detectors combining a dedicated analog board and a commercially available digital board to meet the requirements of astronomical measurements, such as observation of the cosmic microwave background. This paper reports the status of the development of the data acquisition system. We have already achieved simultaneous readout through 120 channels using a direct down-conversion method to decode the signal. A variety of software has been developed and tested using the functionalities of the system and actual detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The EBEX Balloon-borne Experiment—Gondola, Attitude Control, and Control Software

The E and B Experiment (EBEX) was a long-duration balloon-borne instrument created to measure the polarization of the cosmic microwave background (CMB) radiation. EBEX was the first balloon-borne instrument to implement a kilopixel array of transition edge sensor (TES) bolometric detectors and the first CMB experiment to use the digital version of the frequency domain multiplexing system for readout of the TES array. The scan strategy relied on 40 s peak-to-peak constant-velocity azimuthal scans. We report on the unique demands on the design and operation of the payload that resulted from these new technologies and the scan strategy. We describe the solutions implemented, including the development of a power system designed to provide a total of at least 2.3 kW, a cooling system to dissipate 590 W consumed by the detectors' readout system, software to manage and handle the data of the kilopixel array, and specialized attitude reconstruction software. We demonstrate flight performance data reflecting faultless management of the TES array, adequate powering and cooling of the readout electronics, and constraint of attitude reconstruction errors such that the spurious B-modes they induced were less than 10% of the CMB B-mode power spectrum with r = 0.05.

polarization↗

High-Density, High-Bandwidth, Multilevel Holographic Memory

A proposed holographic memory system would be capable of storing data at unprecedentedly high density, and its data transfer performance in both reading and writing would be characterized by exceptionally high bandwidth. The capabilities of the proposed system would greatly exceed even those of a state-of-the art memory system, based on binary holograms (in which each pixel value represents 0 or 1), that can hold .1 terabyte of data and can support a reading or writing rate as high as 1 Gb/s. The storage capacity of the state-of-theart system cannot be increased without also increasing the volume and mass of the system. However, in principle, the storage capacity could be increased greatly, without significantly increasing the volume and mass, if multilevel holograms were used instead of binary holograms. For example, a 3-bit (8-level) hologram could store 8 terabytes, or an 8-bit (256-level) hologram could store 256 terabytes, in a system having little or no more size and mass than does the state-of-the-art 1-terabyte binary holographic memory. The proposed system would utilize multilevel holograms. The system would include lasers, imaging lenses and other beam-forming optics, a block photorefractive crystal wherein the holograms would be formed, and two multilevel spatial light modulators in the form of commercially available deformable-mirror-device spatial light modulators (DMDSLMs) made for use in high speed input conversion of data up to 12 bits. For readout, the system would also include two arrays of complementary metal oxide/semiconductor (CMOS) photodetectors matching the spatial light modulators. The system would further include a reference-beam sterring device (equivalent of a scanning mirror), containing no sliding parts, that could be either a liquid-crystal phased-array device or a microscopic mirror actuated by a high-speed microelectromechanical system. Time-multiplexing and the multilevel nature of the DMDSLM would be exploited to enable writing and reading of multilevel holograms. The DMDSLM would also enable transfer of data at a rate of 7.6 Gb/s or perhaps somewhat higher.

Chao, Tien-Hsin↗

Waveform processing using neural network algorithms on the front-end electronics

In a multi-channel radiation detector readout system, waveform sampling, digitization, and raw data transmission to the data acquisition system constitute a conventional processing chain. The deposited energy on the sensor is estimated by extracting peak amplitudes, area under pulse envelopes from the raw data, and starting times of signals or time of arrivals. However, such quantities can be estimated using machine learning algorithms on the front-end Application-Specific Integrated Circuits (ASICs), often termed as “edge computing”. Edge computation offers enormous benefits, especially when the analytical forms are not fully known or the registered waveform suffers from noise and imperfections of practical implementations. In this work, we aim to predict peak amplitude from a single waveform snippet whose rising and falling edges containing only 3 to 4 samples. We thoroughly studied two well-accepted neural network algorithms, Multi-Layer Perceptron (MLP) and Convolutional Neural Network (CNN) by varying their model sizes. Further, to better fit front-end electronics, neural network model reduction techniques, such as network pruning methods and variable-bit quantization approaches, were also studied. By combining pruning and quantization, our best performing model has the size of 1.5 KB, reduced from 16.6 KB of its full model counterpart. It can reach mean absolute error of 0.034 comparing to that of a naive baseline of 0.135. Such parameter-efficient and predictive neural network models established feasibility and practicality of their deployment on front-end ASICs.

47 OTHER INSTRUMENTATION↗

Particle identification studies with a full-size 4-GEM prototype for the ALICE TPC upgrade

We present that a large Time Projection Chamber is the main device for tracking and charged-particle identification in the ALICE experiment at the CERN LHC. After the second long shutdown in 2019/20, the LHC will deliver Pb beams colliding at an interaction rate of about 50 kHz, which is about a factor of 50 above the present readout rate of the TPC. This will result in a significant improvement on the sensitivity to rare probes that are considered key observables to characterize the QCD matter created in such collisions. In order to make full use of this luminosity, the currently used gated Multi-Wire Proportional Chambers will be replaced. The upgrade relies on continuously operated readout detectors employing Gas Electron Multiplier technology to retain the performance in terms of particle identification via the measurement of the specific energy loss by ionization d/d. A full-size readout chamber prototype was assembled in 2014 featuring a stack of four GEM foils as an amplification stage. The performance of the prototype was evaluated in a test beam campaign at the CERN PS. Finally, the d/d resolution complies with both the performance of the currently operated MWPC-based readout chambers and the challenging requirements of the ALICE TPC upgrade program. Detailed simulations of the readout system are able to reproduce the data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advanced dosimetry systems for the space transport and space station

Advanced dosimetry system concepts are described that will provide automated and instantaneous measurement of dose and particle spectra. Systems are proposed for measuring dose rate from cosmic radiation background to greater than 3600 rads/hr. Charged particle spectrometers, both internal and external to the spacecraft, are described for determining mixed field energy spectra and particle fluxes for both real time onboard and ground-based computer evaluation of the radiation hazard. Automated passive dosimetry systems consisting of thermoluminescent dosimeters and activation techniques are proposed for recording the dose levels for twelve or more crew members. This system will allow automatic onboard readout and data storage of the accumulated dose and can be transmitted to ground after readout or data records recovered with each crew rotation.

Wailly, L. F.↗

Upgrade of the Minos+ Experiment Data Acquisition for the High Energy NuMI Beam Run

The Minos+ experiment is an extension of the Minos experiment at a higher energy and more intense neutrino beam, with the data collection having begun in the fall of 2013. The neutrino beam is provided by the Neutrinos from the Main Injector (NuMI) beam-line at Fermi National Accelerator Laboratory (Fermilab). The detector apparatus consists of two main detectors, one underground at Fermilab and the other in Soudan, Minnesota with the purpose of studying neutrino oscillations at a base line of 735 km. The original data acquisition system has been running for several years collecting data from NuMI, but with the extended run from 2013, parts of the system needed to be replaced due to obsolescence, reliability problems, and data throughput limitations. Specifically, we have replaced the front-end readout controllers, event builder, and data acquisition computing and trigger processing farms with modern, modular and reliable devices with few single points of failure. The new system is based on gigabit Ethernet TCP/IP communication to implement the event building and concatenation of data from many front-end VME readout crates. The simplicity and partitionability of the new system greatly eases the debugging and diagnosing process. As a result, the new system improves throughput by about a factor of three compared to the old system, up to 800 megabits per second, and has proven robust and reliable in the current run.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗