Search NASASearch

SEARCH · Search NASA

Results for “DATA REDUCTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Operational Data Reduction Procedure for Determining Density and Vertical Structure of the Martian Upper Atmosphere from Mars Global Surveyor Accelerometer Measurements

The success of aerobraking by the Mars Global Surveyor (MGS) spacecraft was partly due to the analysis of MGS accelerometer data. Accelerometer data was used to determine the effect of the atmosphere on each orbit, to characterize the nature of the atmosphere, and to predict the atmosphere for future orbits. To interpret the accelerometer data, a data reduction procedure was developed to produce density estimations utilizing inputs from the spacecraft, the Navigation Team, and pre-mission aerothermodynamic studies. This data reduction procedure was based on the calculation of aerodynamic forces from the accelerometer data by considering acceleration due to gravity gradient, solar pressure, angular motion of the MGS, instrument bias, thruster activity, and a vibration component due to the motion of the damaged solar array. Methods were developed to calculate all of the acceleration components including a 4 degree of freedom dynamics model used to gain a greater understanding of the damaged solar array. The total error inherent to the data reduction procedure was calculated as a function of altitude and density considering contributions from ephemeris errors, errors in force coefficient, and instrument errors due to bias and digitization. Comparing the results from this procedure to the data of other MGS Teams has demonstrated that this procedure can quickly and accurately describe the density and vertical structure of the Martian upper atmosphere.

Cancro, George J.

Achieving high data reduction with integral cubic B-splines

During geometry processing, tangent directions at the data points are frequently readily available from the computation process that generates the points. It is desirable to utilize this information to improve the accuracy of curve fitting and to improve data reduction. This paper presents a curve fitting method which utilizes both position and tangent direction data. This method produces G(exp 1) non-rational B-spline curves. From the examples, the method demonstrates very good data reduction rates while maintaining high accuracy in both position and tangent direction.

Chou, Jin J.

Program documentation crew system vidar data reduction (CSVIDR) program

The Crew System Vidar Data Reduction (CSVIDR) program was written to process selected portions of data acquired from long term tests of space shuttle crew equipment. Data are recorded on a seven track computer compatible tape using the Vidar autodata eight processing system. The input tape is in a six bit binary coded decimal format. The 1110 hardware conversion option is used to convert all data from a BCD format to Fieldata since the majority of the data is output without further conversion. Data is retrieved from a character string, calibrated, tabulated, printed, and output on a fixed sample rate tape for use as input to a general purpose plot program.

Vanwie, H. B.

Tornado detection data reduction and analysis

Data processing and analysis was provided in support of tornado detection by analysis of radio frequency interference in various frequency bands. Sea state determination data from short pulse radar measurements were also processed and analyzed. A backscatter simulation was implemented to predict radar performance as a function of wind velocity. Computer programs were developed for the various data processing and analysis goals of the effort.

Davisson, L. D.

A new algorithm for five-hole probe calibration, data reduction, and uncertainty analysis

A new algorithm for five-hole probe calibration and data reduction using a non-nulling method is developed. The significant features of the algorithm are: (1) two components of the unit vector in the flow direction replace pitch and yaw angles as flow direction variables; and (2) symmetry rules are developed that greatly simplify Taylor's series representations of the calibration data. In data reduction, four pressure coefficients allow total pressure, static pressure, and flow direction to be calculated directly. The new algorithm's simplicity permits an analytical treatment of the propagation of uncertainty in five-hole probe measurement. The objectives of the uncertainty analysis are to quantify uncertainty of five-hole results (e.g., total pressure, static pressure, and flow direction) and determine the dependence of the result uncertainty on the uncertainty of all underlying experimental and calibration measurands. This study outlines a general procedure that other researchers may use to determine five-hole probe result uncertainty and provides guidance to improve measurement technique. The new algorithm is applied to calibrate and reduce data from a rake of five-hole probes. Here, ten individual probes are mounted on a single probe shaft and used simultaneously. Use of this probe is made practical by the simplicity afforded by this algorithm.

Reichert, Bruce A.

Program documentation for the space environment test division post-test data reduction program (GNFLEX)

The Space Environment Test Division Post-Test Data Reduction Program processes data from test history tapes generated on the Flexible Data System in the Space Environment Simulation Laboratory at the National Aeronautics and Space Administration/Lyndon B. Johnson Space Center. The program reads the tape's data base records to retrieve the item directory conversion file, the item capture file and the process link file to determine the active parameters. The desired parameter names are read in by lead cards after which the periodic data records are read to determine parameter data level changes. The data is considered to be compressed rather than full sample rate. Tabulations and/or a tape for generating plots may be output.

Jones, L. D.

Computer program of data reduction procedures for facilities using CO2-N2-O2-Ar equilibrium real-gas mixtures

Data reduction procedures for determining free-stream and post-normal-shock flow conditions are presented. These procedures are applicable to flows of CO2, N2, O2, Ar, or mixtures of these gases and include the effects of dissociation and ionization. The assumption of thermochemical equilibrium free-stream and post-normal-shock flow is made. Although derived primarily to meet the immediate needs of an expansion tube of a hot gas radiation research facility, these procedures are applicable to any supersonic or hypersonic test facility using these gases or mixtures thereof. The data reduction procedures are based on combinations of three of the following flow parameters measured in the immediate vicinity of the test section: (1) stagnation pressure behind normal shock, (2) free-stream static pressure, (3) stagnation-point heat-transfer rate, (4) free-stream velocity, and (5) free-stream density. Thus, these procedures do not depend explicitly upon measured or calculated upstream flow parameters. The procedures are incorporated into a single computer program written in FORTRAN IV language. A listing of this computer program is presented, along with a description of the inputs required and a sample of the data printout.

Miller, C. G., III

Strain Gauge Balance Calibration and Data Reduction at NASA Langley Research Center

This paper will cover the standard force balance calibration and data reduction techniques used at Langley Research Center. It will cover balance axes definition, balance type, calibration instrumentation, traceability of standards to NIST, calibration loading procedures, balance calibration mathematical model, calibration data reduction techniques, balance accuracy reporting, and calibration frequency.

Ferris, A. T. Judy

The Gravity Probe B `Niobium bird' experiment: Verifying the data reduction scheme for estimating the relativistic precession of Earth-orbiting gyroscopes

Gravity Probe B (GP-B) is a relatively gyroscope experiment begun at Stanford University in 1960 and supported by NASA since 1963. This experiment will check, for the first time, the relativistic precession of an Earth-orbiting gyroscope that was predicted by Einstein's General Theory of Relativity, to an accuracy of 1 milliarcsecond per year or better. A drag-free satellite will carry four gyroscopes in a polar orbit to observe their relativistic precession. The primary sensor for measuring the direction of gyroscope spin axis is the SQUID (superconducting quantum interference device) magnetometer. The data reduction scheme designed for the GP-B program processes the signal from the SQUID magnetometer and estimates the relativistic precession rates. We formulated the data reduction scheme and designed the Niobium bird experiment to verify the performance of the data reduction scheme experimentally with an actual SQUID magnetometer within the test loop. This paper reports the results from the first phase of the Niobium bird experiment, which used a commercially available SQUID magnetometer as its primary sensor, and adresses the issues they raised. The first phase resulted in a large, temperature-dependent bias drift in the insensitive design and a temperature regulation scheme.

Uemaatsu, Hirohiko

A New NASTRAN Capability for Data Reduction

A new module, MODB, for the data reduction of NASTRAN results is described. NASTRAN analysis results can be filtered and sorted for minimum/maximum values and the printed output resulting from large NASTRAN runs can be limited based on a number of available user options. The sorting is done on stresses, forces and vector quantities like displacements, velocity, and acceleration. The module can be accessed via DMAP alters to existing rigid formats, and has been used on a large number of statics and dynamics problems resulting in considerable savings in cost, time, and the amount of printing.

Gallo, M.

Improved Data Reduction Algorithm for the Needle Probe Method Applied to In-Situ Thermal Conductivity Measurements of Lunar and Planetary Regoliths

The needle probe method (also known as the' hot wire' or 'line heat source' method) is widely used for in-situ thermal conductivity measurements on soils and marine sediments on the earth. Variants of this method have also been used (or planned) for measuring regolith on the surfaces of extra-terrestrial bodies (e.g., the Moon, Mars, and comets). In the near-vacuum condition on the lunar and planetary surfaces, the measurement method used on the earth cannot be simply duplicated, because thermal conductivity of the regolith can be approximately 2 orders of magnitude lower. In addition, the planetary probes have much greater diameters, due to engineering requirements associated with the robotic deployment on extra-terrestrial bodies. All of these factors contribute to the planetary probes requiring much longer time of measurement, several tens of (if not over a hundred) hours, while a conventional terrestrial needle probe needs only 1 to 2 minutes. The long measurement time complicates the surface operation logistics of the lander. It also negatively affects accuracy of the thermal conductivity measurement, because the cumulative heat loss along the probe is no longer negligible. The present study improves the data reduction algorithm of the needle probe method by shortening the measurement time on planetary surfaces by an order of magnitude. The main difference between the new scheme and the conventional one is that the former uses the exact mathematical solution to the thermal model on which the needle probe measurement theory is based, while the latter uses an approximate solution that is valid only for large times. The present study demonstrates the benefit of the new data reduction technique by applying it to data from a series of needle probe experiments carried out in a vacuum chamber on JSC-1A lunar regolith stimulant. The use of the exact solution has some disadvantage, however, in requiring three additional parameters, but two of them (the diameter and the volumetric heat capacity of the probe) can be measured and the other (the volumetric heat capacity of the regolith/stimulant) may be estimated from the surface geologic observation and temperature measurements. Therefore, overall, the new data reduction scheme would make in-situ thermal conductivity measurement more practical on planetary missions.

JSC-1A

Machine Learning-Based Extreme Data Reduction for Prompt Supernova Pointing at DUNE

One of the goals of the Deep Underground Neutrino Experiment (DUNE) is to use the massive underground liquid argon time projection chamber (LArTPC) detectors at its far site for multimessenger astronomy (MMA), in the detection of neutrinos from core-collapse supernovae (SNe). Its current baseline trigger strategy detects activity in the detector that is consistent with supernova (SN) neutrinos and saves the raw data for further offline analysis but provides no prompt pointing information crucial for optical follow-ups by other observatories. This approach is based on the assumption that prompt pointing determination using raw data is computationally prohibitive. In this article, we demonstrate a proof-of-concept based on applying extreme data reduction on the buffered SN data in the DUNE data acquisition (DAQ) system’s front-end computers using a machine learning (ML) workflow. This reduces the data by ~5 orders of magnitude, allowing a full track reconstruction to be carried out quickly on a single server. The total time to perform the ML-based data reduction and the full track reconstruction is less than the time to transfer the SN data back to Fermilab or a high-performance computing (HPC) center. This shows that prompt processing of raw SN data is possible and, in fact, trivial once the data have been reduced to reject radiological backgrounds, paving the way to a high-quality SN pointing trigger that is based on fully reconstructed data instead of trigger primitives (TPs).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Data Reduction Pipeline for the CHARIS Integral-Field Spectrograph I: Detector Readout Calibration and Data Cube Extraction

We present the data reduction pipeline for CHARIS, a high-contrast integral-field spectrograph for the Subaru Telescope. The pipeline constructs a ramp from the raw reads using the measured nonlinear pixel response and reconstructs the data cube using one of three extraction algorithms: aperture photometry, optimal extraction, or chi-squared fitting. We measure and apply both a detector flatfield and a lenslet flatfield and reconstruct the wavelength- and position-dependent lenslet point-spread function (PSF) from images taken with a tunable laser. We use these measured PSFs to implement a chi-squared-based extraction of the data cube, with typical residuals of approximately 5 percent due to imperfect models of the under-sampled lenslet PSFs. The full two-dimensional residual of the chi-squared extraction allows us to model and remove correlated read noise, dramatically improving CHARIS's performance. The chi-squared extraction produces a data cube that has been deconvolved with the line-spread function and never performs any interpolations of either the data or the individual lenslet spectra. The extracted data cube also includes uncertainties for each spatial and spectral measurement. CHARIS's software is parallelized, written in Python and Cython, and freely available on github with a separate documentation page. Astrometric and spectrophotometric calibrations of the data cubes and PSF subtraction will be treated in a forthcoming paper.

Brandt, Timothy D.

Data reduction software for LORAN-C flight test evaluation

A set of programs designed to be run on an IBM 370/158 computer to read the recorded time differences from the tape produced by the LORAN data collection system, convert them to latitude/longitude and produce various plotting input files are described. The programs were written so they may be tailored easily to meet the demands of a particular data reduction job. The tape reader program is written in 370 assembler language and the remaining programs are written in standard IBM FORTRAN-IV language. The tape reader program is dependent upon the recording format used by the data collection system and on the I/O macros used at the computing facility. The other programs are generally device-independent, although the plotting routines are dependent upon the plotting method used. The data reduction programs convert the recorded data to a more readily usable form; convert the time difference (TD) numbers to latitude/longitude (lat/long), to format a printed listing of the TDs, lat/long, reference times, and other information derived from the data, and produce data files which may be used for subsequent plotting.

Fischer, J. P.

Microdensitometer errors: Their effect on photometric data reduction

The performance of densitometers used for photometric data reduction of high dynamic range electrographic plate material is analyzed. Densitometer repeatability is tested by comparing two scans of one plate. Internal densitometer errors are examined by constructing histograms of digitized densities and finding inoperative bits and differential nonlinearity in the analog to digital converter. Such problems appear common to the four densitometers used in this investigation and introduce systematic algorithm dependent errors in the results. Strategies to improve densitometer performance are suggested.

Bozyan, E. P.