Motor Control and Regulation for a Flywheel Energy Storage System

This talk will focus on the motor control algorithms used to regulate the flywheel system at the NASA Glenn Research Center. First a discussion of the inner loop torque control technique will be given. It is based on the principle of field orientation and is implemented without a position or speed sensor (sensorless control). Then the outer loop charge and discharge algorithm will be presented. This algorithm controls the acceleration of the flywheel during charging and the deceleration while discharging. The algorithm also allows the flywheel system to regulate the DC bus voltage during the discharge cycle.

Kenny, Barbara↗

Pre-Launch Algorithms and Risk Reduction in Support of the Geostationary Lightning Mapper for GOES-R and Beyond

The Geostationary Lightning Mapper (GLM) is a single channel, near-IR optical transient event detector, used to detect, locate and measure total lightning activity over the full-disk as part of a 3-axis stabilized, geostationary weather satellite system. The next generation NOAA Geostationary Operational Environmental Satellite (GOES-R) series with a planned launch in 2014 will carry a GLM that will provide continuous day and night observations of lightning from the west coast of Africa (GOES-E) to New Zealand (GOES-W) when the constellation is fully operational.The mission objectives for the GLM are to 1) provide continuous,full-disk lightning measurements for storm warning and Nowcasting, 2) provide early warning of tornadic activity, and 3) accumulate a long-term database to track decadal changes of lightning. The GLM owes its heritage to the NASA Lightning Imaging Sensor (1997-Present) and the Optical Transient Detector (1995-2000), which were developed for the Earth Observing System and have produced a combined 13 year data record of global lightning activity. Instrument formulation studies were completed in March 2007 and the implementation phase to develop a prototype model and up to four flight units is expected to begin in latter part of the year. In parallel with the instrument development, a GOES-R Risk Reduction Team and Algorithm Working Group Lightning Applications Team have begun to develop the Level 2B algorithms and applications. Proxy total lightning data from the NASA Lightning Imaging Sensor on the Tropical Rainfall Measuring Mission (TRMM) sate]lite and regional test beds (e.g., Lightning Mapping Arrays in North Alabama and the Washington DC Metropolitan area) are being used to develop the pre-launch algorithms and applications, and also improve our knowledge of thunderstorm initiation and evolution. Real time lightning mapping data provided to selected National Weather Service forecast offices in Southern and Eastern Region are also improving our understanding of the application of these data in the severe storm warning process and help to accelerate the development of the pre-launch algorithms and Nowcasting applications. Abstract for the 3 rd Conference on Meteorological

Goodman, Steven↗

Tests of Radar Rainfall Retrieval Algorithms

The NASA/JPL Airborne Rain Mapping Radar (ARMAR) operates at 14 GHz. ARMAR flew on the NASA DC-8 aircraft during Tropical Ocean Global Atmosphere (TOGA) Coupled Ocean Atmosphere Response Experiment (COARE), collecting data in oceanic mesoscale convective systems, similar to those now being observed by the Tropical Rainfall Measuring Mission (TRMM) satellite, which includes a 14-GHz precipitation radar. Several algorithms for retrieving rain rate from downward looking radars are in existence. These can be categorized as deterministic and stochastic. Deterministic algorithms use the path integrated attenuation (PIA), measured by the surface reference technique, as a constraint. One deterministic algorithm corrects the attenuation-rainfall (k-R) relation, while another corrects the reflectivity rainfall (ZR) relation. Stochastic algorithms apply an Extended Kalman Filter to the reflectivity profile. One employs radar reflectivity only; the other additionally uses the PIA. We find that the stochastic algorithm with PIA is the most robust algorithm with regard to incorrect assumptions about the drop-size distribution (DSD). The deterministic algorithm that uses the PIA to adjust the Z-R relation is also fairly robust and produces rain rates similar to the stochastic algorithm that uses the PIA. The deterministic algorithm that adjusts only the k-R relation and the stochastic radar-only algorithm are more sensitive to assumptions about the DSD. It is likely that they underestimate convective rainfall, especially if the DSD is erroneously assumed to be appropriate for stratiform rain conditions. The underestimation is illustrated in the diagram. The algorithm labeled D IS initially assumes a DSD that is appropriate for stratiform. rain, while the rain is most likely convective. The PIA constraint causes the k-R relation to be adjusted, resulting in a much lower rain rate than the other algorithms. Additional information is contained in the original.

Durden, Stephen L.↗

Growth differentiation factor-15 promotes immune escape of ovarian cancer via targeting CD44 in dendritic cells

Immune escape is the main cause of the low response rate to immunotherapy for cancer, including ovarian cancer. Growth differentiation factor-15 (GDF-15) inhibits immune cell function. However, only few reports described the mechanism. Therefore, the aim of this study was to investigate the mechanism of immune escape regulated by GDF-15 in ovarian cancer. Ovarian cancer patients and healthy women were enrolled in this study. Immunohistochemistry and ELISA were performed to measure GDF-15 expression. Immunoprecipitation combined with mass spectrometry, surface plasmon resonance, and co-immunoprecipitation assay were used to evaluate the interaction between GDF-15 and the surface molecules of DCs. Immunofluorescence analysis, flow cytometry and transwell assay were used to evaluate additional effects of GDF-15 on DCs. The results showed that GDF-15 expression was higher in the ovarian cancer patients compared to that in the healthy women. The TIMER algorithm revealed that highly GDF-15 expression is associated with immune DC infiltration in immunoreactive high-grade serous carcinoma. A further study showed that GDF-15 suppressed DCs maturation, as well as IL-12p40 and TNF-α secretion, the length and number of protrusions and the migration. More importantly, CD44 in the surface of DCs interacted with GDF-15. The overexpression of CD44 in DCs resulted in the suppression of the inhibitory effect of GDF-15 on the length and number of DC synapses. In DCs overexpressing CD44 the inhibition of GDF-15 on the expression of CD11c, CD83 and CD86 was decreased, while in DCs with a knockdown of CD44 the inhibition was further enhanced. Knockdown of CD44 in DCs enhanced the inhibitory effect of GDF-15 on DC migration, while the overexpression of CD44 inhibited the inhibitory effect of GDF-15 on DC migration. In conclusion, the present study suggested that GDF-15 might facilitate ovarian cancer immune escape by interacting with CD44 in DCs to inhibit their function.

60 APPLIED LIFE SCIENCES↗

The LSBmax algorithm for boosting resilience of electric grids post (N‐2) contingencies

Abstract A computationally improved algorithm is presented to find the best transmission switching (TS) candidate for boosting resilience of electricity grids subject to ( N ‐2) contingencies. Here, resilience is computed as the reduction in load shed after the above‐mentioned ( N‐ ) contingencies. TS is a planned line outage, and past research shows that changing the transmission system's topology changes the power flow and removes post contingency violations. Finding the best TS candidate in a computationally suitable time for effectively boosting resilience is a challenge. The best TS candidate is found using a novel heuristic method by decreasing the search space based on proximity to the bus with the maximum load shedding (LSB). The LSB algorithm is faster than existing algorithms in the literature; and, it is compatible with both the AC and DC optimal power flow formulations. To validate the authors' claims of speedup and accuracy, two metrics are used to analyze the results from the IEEE 39‐bus and 118‐bus systems. Finally, the inherent parallelism of the LSB algorithm is leveraged on a high‐performance computing platform and applied to the large‐scale Polish 2383‐bus test system to validate scalability in both size and speedup in computation time.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Soft-Fault Detection Technologies Developed for Electrical Power Systems

The NASA Glenn Research Center, partner universities, and defense contractors are working to develop intelligent power management and distribution (PMAD) technologies for future spacecraft and launch vehicles. The goals are to provide higher performance (efficiency, transient response, and stability), higher fault tolerance, and higher reliability through the application of digital control and communication technologies. It is also expected that these technologies will eventually reduce the design, development, manufacturing, and integration costs for large, electrical power systems for space vehicles. The main focus of this research has been to incorporate digital control, communications, and intelligent algorithms into power electronic devices such as direct-current to direct-current (dc-dc) converters and protective switchgear. These technologies, in turn, will enable revolutionary changes in the way electrical power systems are designed, developed, configured, and integrated in aerospace vehicles and satellites. Initial successes in integrating modern, digital controllers have proven that transient response performance can be improved using advanced nonlinear control algorithms. One technology being developed includes the detection of "soft faults," those not typically covered by current systems in use today. Soft faults include arcing faults, corona discharge faults, and undetected leakage currents. Using digital control and advanced signal analysis algorithms, we have shown that it is possible to reliably detect arcing faults in high-voltage dc power distribution systems (see the preceding photograph). Another research effort has shown that low-level leakage faults and cable degradation can be detected by analyzing power system parameters over time. This additional fault detection capability will result in higher reliability for long-lived power systems such as reusable launch vehicles and space exploration missions.

Button, Robert M.↗

A Graph-Net with Node Embeddings to Detect False Data Injection Attacks in Photovoltaic Systems

Distributed energy resources (DER) contribute to the operational stability of the larger power grid both at utility-scale as well as commercial and residential scales in aggregated forms. These DER in-turn are susceptible to increasing cyber threats. An adversary can plug into the same local network that a field photovoltaic (PV) system uses to interconnect its data loggers and inverters and manipulate certain measurements collected from the network or trick existing irradiance and inverter readings through false data injection attacks (FDIA). Control routines that rely on these measurements can propagate the false data, impacting critical decisions that result in a suboptimal operation or even cause intentional harm leading to inverter-tripping or unscheduled loads that need to be shed. To detect FDIA in PV systems, the paper introduces an attention-based graph neural network with node embeddings and applied it to a simple prototypical DC-coupled microgrid with PV, energy storage, and load. The algorithm shows a detection accuracy of up to 98.95%. The proposed FDIA detection technique will provide micro-grid operators with an effective method to safeguard their systems, guaranteeing the secure and reliable operation.

Parvez, Imtiaz [Utah Valley University]↗

Iterative and Self-Consistent Estimation of Degradation and Soiling Loss in PV Systems - A Case Study

In many parts of the world, soiling is a significant loss mechanism for PV energy production. Methods for accurately quantifying historical and current soiling losses are needed. Furthermore, state-of-the-art methods to estimate degradation rates based on production data do not handle soiling in a satisfactory manner. In order to accurately estimate either of these quantities, it is in many cases helpful to consider their combined effect on PV system performance. In this work we make use of the Combined Degradation and Soiling (CODS) algorithm, which iteratively decomposes time series of daily normalized energy yield into four components: a soiling ratio, a degradation trend, seasonal variations, and noise. We demonstrate the use of the model on field performance data from a utility-scale power plant in a high-soiling environment in the Middle East. We apply the algorithm to the temperature-corrected performance index of the DC power on inverter level, quantifying how soiling varies over time and through the plant. The irradiation-weighted average soiling loss in this plant is 2.3 %, with a median soiling rate of -0.086 %/day. Between the inverters in the site in study, estimated degradation rates range between -0.86 %/year and -0.15 %/year, with a mean rate of -0.48 %/year.

41 EE - Solar Energy Technologies Office (EE-4S)↗

A Comprehensive Strategy for Grid Forming Control in DC Coupled Photovoltaic and Battery Energy Storage Inverters

This paper presents an integrated DC-DC and DCAC grid-forming control strategy for DC-coupled photovoltaic (PV) plus battery energy storage systems, considering the effect of DC link voltage variations caused by direct PV connections. A power reference algorithm determines power distribution between the PV and battery to the grid while observing device power ratings to prevent the over-rating of components and keep the battery's state of charge within an acceptable range. The simulated utility-scale model in MATLAB/Simulink illustrates its ability against extreme phase angle variation contingencies in the grid while controlled through grid-forming control with a fast dynamic on DC link voltage. The simulation results confirm the effectiveness of the proposed control in integrating PV plus battery configurations with grid forming control and maintaining reliable grid operation under severe grid disturbances.

battery, boost, control, energy storage, grid form↗

Motor Control of Two Flywheels Enabling Combined Attitude Control and Bus Regulation

This presentation discussed the flywheel technology development work that is ongoing at NASA GRC with a particular emphasis on the flywheel system control. The "field orientation" motor/generator control algorithm was discussed and explained. The position-sensorless angle and speed estimation algorithm was presented. The motor current response to a step change in command at low (10 kRPM) and high (60 kRPM) was discussed. The flywheel DC bus regulation control was explained and experimental results presented. Finally, the combined attitude control and energy storage algorithm that controls two flywheels simultaneously was presented. Experimental results were shown that verified the operational capability of the algorithm. shows high speed flywheel energy storage (60,000 RPM) and the successful implementation of an algorithm to simultaneously control both energy storage and a single axis of attitude with two flywheels. Overall, the presentation demonstrated that GRC has an operational facility that

Kenny, Barbara H.↗

A Nonlinear Digital Control Solution for a DC/DC Power Converter

A digital Nonlinear Proportional-Integral-Derivative (NPID) control algorithm was proposed to control a 1-kW, PWM, DC/DC, switching power converter. The NPID methodology is introduced and a practical hardware control solution is obtained. The design of the controller was completed using Matlab (trademark) Simulink, while the hardware-in-the-loop testing was performed using both the dSPACE (trademark) rapid prototyping system, and a stand-alone Texas Instruments (trademark) Digital Signal Processor (DSP)-based system. The final Nonlinear digital control algorithm was implemented and tested using the ED408043-1 Westinghouse DC-DC switching power converter. The NPID test results are discussed and compared to the results of a standard Proportional-Integral (PI) controller.

Zhu, Minshao↗

Capacitor Voltage Ripple Reduction of A 4-Level Hybrid Clamped Converter Using Switching State Redundancy for Medium-Voltage Drive

Abstract—A four-level Hybrid Clamped Converter (4LHCC) is a novel promising DC/AC multilevel converter for high-efficiency medium-voltage drives. This paper presents a new control method of the 4L-HCC using the switching state redundancy to reduce the DC-link capacitor voltage ripples at low frequencies (<=30 Hz). The new switching state selection algorithm and flying capacitor balancing method are introduced and analyzed.Both of a3.6 kV 1MW 4L-HCC simulation model and a SiC-based 4L-HCC prototype is established to verify the proposed method. Simulation and experimental result shows that the maximum DC-link capacitor ripple can be reduced effectively from over 50% to less than 5% at low frequencies with the new method. Meanwhile, load voltage and currentdistortion caused by the excessive capacitor rippleisalso mitigatedsignificantly.

hybrid clamped converter, motor drive, voltage bal↗

An NOy* Algorithm for SOLVE

De-nitrification and excess re-nitrification was widely observed by ER-2 instruments in the Arctic vortex during SOLVE in winter/spring 2000. Analyses of these events requires a knowledge of the initial or pre-vortex state of the sampled air masses. The canonical relationship of NOy to the long-lived tracer N2O observed in the unperturbed stratosphere is generally used for this purpose. In this paper we will attempt to establish the current unperturbed NOy:N2O relationship (NOy* algorithm) using the ensemble of extra-vortex data from in situ instruments flying on the ER-2 and DC-8, and from the Mark IV remote measurements on the OMS balloon. Initial analysis indicates a change in the SOLVE NOy* from the values predicted by the 1994 Northern Hemisphere NOy* algorithm which was derived from the observations in the ASHOE/MAESA campaign.

Loewenstein, M.↗

Table-aided design of the energy-storage reactor in dc-to-dc converters

A new procedure for the selection of magnetic cores for use in energy-storage dc-to-dc power converters which eliminates the need for an automated computer search algorithm and stored data file is presented. The converter configurations included in the procedure are the three commonly encountered single-winding converters for voltage step-up, for current step-up and for voltage step-up/current step-up, and for the two-winding converter for voltage step-up/current step-up. For each converter configuration, three types of controllers are considered - constant-frequency, constant on-time and constant off-time. Using concepts developed from analyses of these converters by considering the transfer of energy by means of an energy-storage inductor or transformer, a special table of parameters calculated from magnetic core data is constructed and leads to a considerably simplified design procedure.

Owen, H. A., Jr.↗

Low power, CMOS digital autocorrelator spectrometer for spaceborne applications

A 128-channel digital autocorrelator spectrometer using four 32 channel low power CMOS correlator chips was built and tested. The CMOS correlator chip uses a 2-bit multiplication algorithm and a full-custom CMOS VLSI design to achieve low DC power consumption. The digital autocorrelator spectrometer has a 20 MHz band width, and the total DC power requirement is 6 Watts.

Chandra, Kumar↗

Best Merge Region Growing with Integrated Probabilistic Classification for Hyperspectral Imagery

A new method for spectral-spatial classification of hyperspectral images is proposed. The method is based on the integration of probabilistic classification within the hierarchical best merge region growing algorithm. For this purpose, preliminary probabilistic support vector machines classification is performed. Then, hierarchical step-wise optimization algorithm is applied, by iteratively merging regions with the smallest Dissimilarity Criterion (DC). The main novelty of this method consists in defining a DC between regions as a function of region statistical and geometrical features along with classification probabilities. Experimental results are presented on a 200-band AVIRIS image of the Northwestern Indiana s vegetation area and compared with those obtained by recently proposed spectral-spatial classification techniques. The proposed method improves classification accuracies when compared to other classification approaches.

Tarabalka, Yuliya↗

The Effectiveness of Power Distribution Systems for Deployment on the Lunar Surface

Lunar habitation missions are currently being planned to have astronauts return to the moon by the mid 2020’s with a sustained lunar presence by the end of the decade. The various landed modules needed to support the missions are expected to be distributed around Shackleton Crater at distances ranging from 1 to 15 km and with power needs ranging from 10 kW to 50kW. Current plans call for a solar array to be installed on the rim of the crater that receives near-constant sunlight year around with a power distribution system that transfers power from the source to consumers. This paper details several power distribution systems: DC transmission lines, radio frequency power beaming, and optical power beaming. Sizing algorithms for each of these distributions systems along with their necessary subsystems were developed from literature and subject matter expertise input. Several experiments were then conducted to determine the performance of the systems along with their sensitivities to changes in assumptions for various sub-components. The defined Figures of Merit enable mission designers to select the best power distribution system for each possible power consumer mission scenario. The experimental results were analyzed and compiled into a set of figures that highlight the conditions for which a certain system outperforms the other.

Bradford Robertson↗

The Effectiveness of Power Distribution Systems for Deployment on the Lunar Surface

Lunar habitation missions are currently being planned to have astronauts return to the moon by the mid 2020’s with a sustained lunar presence by the end of the decade. The various landed modules needed to support the missions are expected to be distributed around Shackleton Crater at distances ranging from 1 to 15 km and with power needs ranging from 10 kW to 50kW. Current plans call for a solar array to be installed on the rim of the crater that receives near-constant sunlight year around with a power distribution system that transfers power from the source to consumers. This paper details several power distribution systems: DC transmission lines, radio frequency power beaming, and optical power beaming. Sizing algorithms for each of these distributions systems along with their necessary subsystems were developed from literature and subject matter expertise input. Several experiments were then conducted to determine the performance of the systems along with their sensitivities to changes in assumptions for various sub-components. The defined Figures of Merit enable mission designers to select the best power distribution system for each possible power consumer mission scenario. The experimental results were analyzed and compiled into a set of figures that highlight the conditions for which a certain system outperforms the other.