Search NASA⌕ Search

SEARCH · Search NASA

Results for “DC fast charging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

69 records · Page 4

Device Voltage Stress from Ground Leakage Current in Medium-Voltage Solid-State Transformer

Grounding related issues are critical for safe and reliable operation of solid-state transformer (SST) in medium-voltage (MV) applications, e.g., solar photovoltaic and energy storage integration, date center, electric vehicle fast charging, etc. This article presents for the first time the issue of additional device voltage stress due to grounding-loop current in current-source SST, using the soft-switching solid-state transformer (S4T) as an example. The S4T features single-stage isolated AC-AC, AC-DC, or DC-DC conversion with full-range ZVS, derived from flyback converter or current-source converter (CSC). However, the flyback operation for CSC-based SST means that magnetizing current flows through the reverse-blocking devices on only one side of the medium-frequency transformer (MFT) at a time. Then, the voltages across the devices, especially those on the other side of the MFT, can be influenced by parasitic current. A parasitic model of a modular S4T (M-S4T) prototype is developed from direct measurements and datasheets. Using the developed parasitic model and equivalent circuits, the causes of the voltage stress are analyzed. A voltage-stress mitigation scheme of connecting additional grounding capacitors is proposed. Damping resistors are also installed to damp out the grounding-loop resonance. A robust parameter design of the proposed scheme is given. The existence of the voltage stress issue and the effectiveness of the proposed scheme are verified experimentally on an MV SiC M-S4T prototype with inherent parameter variations among the five modules in the prototype. Here, both single-module and stacked-module operation are demonstrated during steady state and dynamic conditions up to 4 kV peak.

42 ENGINEERING↗

Ion density waves driving the formation of filamentary dust structures

The PlasmaKristall-4 (PK-4) experiment on the International Space Station allows for the study of the 3-dimensional interaction between plasma and dust particles. Previous simulations of the PK-4 environment have discovered fast moving ionization waves in the dc discharge. These ionization waves vary the plasma parameters by up to an order of magnitude, which may affect the mechanisms responsible for the self-organization of chains seen in the PK-4 experiment. Here, we adapt a molecular dynamics simulation to employ temporally varying plasma conditions in order to investigate the effect on the dust charging and electrostatic potential. In order to describe the differences between the average of the plasma conditions and the time-varying plasma condition, we present a model to reproduce the interaction that takes into account the negative potential from the dust grain and the positive potential from the ion wake.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Soft-Switching Solid-State Transformer With Reduced Conduction Loss

Solid-state transformers (SSTs) are a promising solution photovoltaic (PV), wind, traction, data center, battery energy storage system (BESS), and fast charging electric vehicle (EV) applications. The traditional SSTs are typically three-stage, i.e., hard-switching cascaded multilevel rectifiers and inverters with dual active bridge (DAB) converters, which leads to bulky passives, low efficiency, and high electromagnetic interference (EMI). This article proposes a new soft-switching solid-state transformer (S4T). The S4T has full-range zero-voltage switching (ZVS), electrolytic capacitor-less dc link, and controlled dv/dt, which reduces EMI. The S4T comprises two reverse-blocking current-source inverter (CSI) bridges, auxiliary branches for ZVS, and transformer magnetizing inductor as a reduced dc link with 60% ripple. Compared with the prior S4T, an effective change on the leakage inductance diode is made to reduce the number of the devices on the main power path by 20% for significant conduction loss saving and retain the same functionality of damping the resonance between the leakage and resonant capacitors and recycling trapped leakage energy. The conduction loss saving is crucial, being the dominating loss mechanism in SSTs. Importantly, the proposed single-stage SST not only holds the potential for high power density and high efficiency but also has full functionality, e.g., multiport dc loads integration, voltage regulation, and reactive power compensation, unlike the traditional single-stage matrix SST. The S4T can achieve single-stage isolated bidirectional dc–dc, ac–dc, dc–ac, or ac–ac conversion. It can also be configured input-series output-parallel (ISOP) in a modular way for medium-voltage (MV) grids. Hence, the S4T is a promising candidate for the SST. The full functionality, e.g., voltage buck–boost, multiport, etc., and the universality of the S4T for the dc–dc, dc–ac, and ac–ac conversion are verified through the simulations and experiments of two-port and three-port MV prototypes based on 3.3 kV SiC MOSFETs in dc–dc, dc–ac, and ac–ac modes at 2 kV.

14 SOLAR ENERGY↗

Modeling and Analysis of a Polyphase Wireless Power Transfer System for EV Charging Applications

Extreme fast charging is an emerging technology targeting to significantly decrease charging times of electric vehicles to 10–20 minutes, similar to an interstate gas refueling practice. High-power wireless power transfer (WPT) systems with polyphase electromagnetic couplers can be an attractive solution for these applications due to the very high surface power density of polyphase coils with reduced ripple current characteristics on both the primary and secondary sides that result in more compact designs with reduced dc bus bar capacitor requirements. In addition, WPT systems offer automated charging process, which can be an enabling technology for connected and automated vehicles, with high-efficiency, convenience, safety, and flexibility. This study presents a matrix representation of a mathematical model for a three-phase WPT system with series-series connected three-phase resonant compensation networks. Nonzero interphase mutual inductances between the same side phase windings are considered for tuning to obtain a circuit model for parametric sensitivity. Simulation and experimental results presented for a 50-kW experimental prototype to demonstrate the operation of the polyphase WPT system.

Zeng, Rong↗

7.2 kV Three-Port SiC Single-Stage Current-Source Solid-State Transformer With 90 kV Lightning Protection

This article proposes a multiport modular single-stage current-source solid-state transformer (SST) for applications like photovoltaic, energy storage integration, electric vehicle fast charging, data center, etc. The 7.2 kV 50 kVA current-source SST consists of five input-series output-parallel modules, each based on 3.3 kV SiC reverse-blocking MOSFET-plus-diode modules. The proposed SST has some unique features. First, compared to the voltage-source or matrix converter-based SSTs, the current-source SST has a unique advantage of single-stage isolated AC/DC or AC/AC conversion with an inductive DC link, but no medium-voltage (MV) AC experiments have been reported. This article for the first time demonstrates MV AC current-source SST up to 7.5 kV peak. Second, the multiport SST has a buffer port for active power decoupling (APD) or energy storage integration. The double-line-frequency power ripple from single-phase AC grid normally results in a large capacitor size in MV SSTs. The APD scheme is proposed in MV applications for the first time to enable a reduced DC link and the electrolytic capacitor-less SST with high reliability. Third, as a direct grid-connected converter without line-frequency transformer, insulation and protection are critical. A medium-frequency transformer design passes 55 kV basic-insulation level (BIL) and 60 kV high potential dielectrics withstand test with only 0.09% leakage inductance. Importantly, a lightning protection scheme is presented to protect the SST itself from 90 kV BIL impulse. Fourth, the proposed current-source SST topology is a modular soft-switching solid-state transformer (M-S4T) with full-range zero-voltage switching and controlled dv/dt for low electromagnetic interference. Furthermore, these concepts are verified in a three-port M-S4T prototype with forced oil cooling under single-module, stacked-module, steady-state, and dynamic operations.

14 SOLAR ENERGY↗

Evaluations of Connectors, Inlets, and Adapters on Side-Load and Withstand Force

This report examines the mechanical forces that direct current fast charging (DCFC) electric vehicle supply equipment (EVSE) connectors and electric vehicle (EV) inlet ports experience during normal usage. As we witness the fast and growing variety of EVs, charge port locations, and bigger and more powerful EVSE configurations including the SAE J3400 North American Charging Standard (NACS), which has increased the use of adapters with J3400 and J1772 compatibility. These new conditions contribute to increased mechanical forces due to their size, weight and lever arm effect, which creates the need to study and compare these forces to the limits on UL2251 and IEC 62196-1 standards. This report focuses solely on high power DC charging EVSE connectors, EV inlets and adapters for the specific compatibility cases on J3400 with J1772. We first describe the details of the 100N and the 750N side-load evaluations as described in the standards, then present the data obtained by replicating these tests to finally go into more detail on the findings and our recommendations.

100N↗

Development of Large Area µRWELL Detectors for CLAS12 High Luminosity Upgrade at Jefferson Lab

The high-luminosity upgrade of the CEBAF Large Acceptance Spectrometer (CLAS12) will significantly enhance the physics reach of experiments in Hall B at JLab. However, at the current luminosity of L = 1 × 1035 cm-2 s-1, the reconstruction efficiency of charged particles in the forward region of the CEBAF Large Acceptance Spectrometer (CLAS12) is at the level of 85% and limited in part by the drift chambers inability to handle high occupancy, in the first tracking region (DC-R1) of the Forward Detector. The reconstruction efficiency is expected to drop even lower at higher luminosities with the current tracking technology. Various options under consideration to achieve the desired performance at a higher luminosity of L = 2 × 1035 cm-2 s-1 include the addition of fast tracking layers to complement DC-R1 or the replacement of DC-R1 with a different tracking detector technology altogether. In either case, a novel generation of compact, simple and robust Micro-Pattern Gaseous Detector (MPGD) known as the Resistive Micro-Well detector (µRWELL) is the ideal candidate to satisfy the requirements in terms of timing O (10 ns) and position O (100 µm) resolutions. A large µRWELL prototype, combined with a two-dimensional U-V strip readout layer based on the novel concept of capacitive-sharing approach has been developed as a proof of principle for fast tracking capabilities in the forward region of CLAS12 high-luminosity upgrade. In this talk, we will present the technical aspects of the design choices of the large µRWELL prototype under development and report on the detector assembly process and preliminary performance characteristic tests. We will also discuss the plans for the test and characterization of the prototype in beam during spring 2023 CEBAF run. Finally, we will report on ongoing R&D efforts on small prototypes with the goal to improve rate capability, spatial resolution performance and minimize material thickness.

Gnanvo, Kondo↗

High-Power Oak Ridge Converter (ORC) for Extreme Fast Charging Applications

This project report presents a novel power converter system called Oak Ridge Converter (ORC), a patented technology developed by the Oak Ridge National Laboratory (ORNL) for XFC wireless EV charging systems. ORC integrates the grid interface converter (also known as the active front-end rectifier with power factor correction) with the high-frequency inverter stage, promoting size and cost-effective charging technology with reduced infrastructure costs. The integration of the front-end rectifier with the high-frequency inverter truly eliminates one power conversion stage and achieves more than 33% size, weight, volume, and cost reduction on the wireless charging systems. Furthermore, ORC eliminates the primary side direct current (DC) bus bulk capacitors that are usually aluminum electrolytic capacitors and replaces them with very small, cost-effective, highly reliable, and high-temperature operation-capable alternate current (AC) film capacitors. ORC is also applicable to both single-phase and poly-phase couplers. When used with polyphase couplers, ORC further improves the power density of the overall system with higher power density power electronics. Moreover, ORC is inherently bidirectional and allows the system to provide power back to the grid for grid ancillary or grid support services. The ORC, based on a patented ORNL technology, is an excellent approach to resolving the high-power charging problems as described above, which directly converts the 60 hertz (Hz) line frequency into high frequency (i.e., 85 kilohertz (kHz)) to use with a high-frequency isolation transformer or wireless charging coils while eliminating the primary side number of power conversion stages from two to one. The result of the project is a prototype and reference design for a high-power wireless charging system—including power electronics, magnetics, and thermal—serving as a baseline for product development. The proposed system results are demonstrated for 270 kW of output power, with the system's overall efficiency of 92% from the AC grid, achieving less than 3% current total harmonic distortion (THD) and around 0.99 power factor (PF).

33 ADVANCED PROPULSION SYSTEMS↗

Measurements of time and spatial resolution of AC-LGADs with different designs

AC-LGAD sensors are prime candidates for fast and precise measurement of charged particles in a variety of applications. In a fine-pitched pixel or strip AC-LGAD sensor, the signal generated by the passage of a particle is not localized in a limited volume in the sensor, but is shared among multiple electrodes. This signal sharing characteristic allows us to improve the spatial resolution of AC-LGAD sensors beyond the capabilities of common silicon trackers. Since the magnitude of the shared signal depends on the distance between the pixels or strips and the point of passage of the particle, signal sharing is strongly influenced by the geometry of the sensor. The electrode pitch and gap size as well as the shape can be fine tuned to maximize the space resolution, while keeping the detector granularity and the number of channels to be read out under control. Prototypes of AC-LGAD sensors produced at the Brookhaven National Laboratory covering a variety of possible geometries have been studied via Transient Current Technique using an infrared laser, and the signal sharing, spatial resolution, and time resolution of the different topologies have been measured. These results have been compared with measurements performed in test-beams with 120 GeV protons at the Fermilab Test Beam Facility. A time resolution of ~30 ps can be achieved using AC-LGAD sensors with a thickness of 50 μm, compatible to that of standard DC-coupled LGADs, while presenting a far superior spatial resolution. Finally, this combination of high precision, fast timing capabilities, and low material budget makes AC-LGADs an ideal choice for a truly 4D detector.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Characterization of self-magnetic pinch (SMP) radiographic diode performance on RITS-6 at Sandia National Laboratories. I. Diode dynamics, DC heating to extend radiation pulse

Radiographic diodes focus on an intense electron beam to a small spot size to minimize the source area of energetic photons for radiographic interrogation. The self-magnetic pinch (SMP) diode has been developed as such a source and operated as a load for the six-cavity radiographic integrated test stand (RITS-6) inductive voltage adder driver. While experiments support the generally accepted conclusion that a 1:1 aspect diode (cathode diameter equals anode–cathode gap) delivers optimum SMP performance, such experiments also show that reducing the cathode diameter, while reducing spot size, also results in reduced radiation dose, by as much as 50%, and degraded shot reproducibility. Analysis of the effective electron impingement angle on the anode converter with time made possible by a newly developed dose-rate array diagnostic indicates that fast-developing oscillations of the angle are correlated with early termination of the radiation pulse on many of the smaller-diameter SMP shots. This behavior as a function of relative cathode size persists through experiments with output voltages and currents up to 11.5 MV and 225 kA, respectively, and with spot sizes below approximately few millimeters. Since simulations to date have not predicted such oscillatory behavior, considerable discussion of the angle behavior of SMP shots is made to lend credence to the inference. We report there is clear anecdotal evidence that DC heating of the SMP diode region leads to stabilization of this oscillatory behavior. This is the first of two papers on the performance of the SMP diode on the RITS-6 accelerator.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

EVSE Cybersecurity and Resilience

Consequence-driven Cybersecurity Analysis for Extreme Fast Charging Electric Vehicle Infrastructure Electric vehicle (EV) development and associated charging infrastructure are expected to advance rapidly. Thirty percent of all global vehicle sales may be EVs and hybrid EVs by 2025, and they will rely on increasingly sophisticated strategies for grid integration. Next-generation EV charging infrastructure is expected to include interconnected renewable resources, such as photovoltaic (PV) arrays and battery storage systems, along with grid-edge devices. Although distributed energy resources (DERs) are useful in several ways, such as peak shaving at high demand times and backup supply for added resilience, the integration of vehicle charging and DERs could create more avenues for cyberattack. Physical and/or remote access to EV charging station components, including charge ports, power electronics, controllers, and local generation (e.g., PV and energy storage) could be paths to cause power fluctuations, leading to altered operations at the charging station, escalated privileges to administrative systems, exfiltration of financial information (including personally identifiable information), and reduced grid stability. One compromised EV supply equipment component can open the door to a variety of exploitable vulnerabilities. Cloud computing and mobile application control have the potential to expand the threat surface to non-repudiation and firmware integrity challenges. Vendor clouds have access to hundreds of chargers, and if compromised, can scale the attack surface exponentially. The high power and voltage levels of xFC infrastructure (e.g., 400 kW at 1000- V DC) increase the hazards and ability to impact the grid and vehicles more than lower-power charging systems. Legacy communications systems and protocols could also put EV infrastructure at risk of cyberattacks requiring a robust patch management process. Communications networks link EVs and chargers to several stakeholders - including charging station operators, grid operators, vendors/manufacturers, and aggregators - who have both physical and network access to share information for control, monitoring, and analytics. Information in these networks that is vulnerable to compromise includes the state of charge, charging duration, payment information, electricity price, and load control. Analyzing and prioritizing these interconnections risks could help address cybersecurity related to data leakage and manipulation.

charging↗

Cybersecurity Platform and Certification Framework Development for Extreme Fast Charging (XFC)-Integrated Charging Ecosystem (Final Project Report)

This report summarizes a pioneering effort in Electric Vehicle charging infrastructure ecosystem cybersecurity requirements, assessment methodologies, functional verification, as well as embodiment of the key technologies in the form of hardware and software tools being made available to the public. EPRI led a team of experts, as well as a stakeholder coalition encompassing all key actors in the EV charging infrastructure ecosystem that includes eXtreme Fast Charging (XFC) equipment (defined as 200kW or above). EV charging infrastructure in the United States is a patchwork of networks that have continued to grow organically and have been designed to serve the charging needs of the EV owners, who are their customers. In doing so, each network provider, as well as their connected entities such as the cloud Electric Vehicle Service Providers or EVSPs, utility back office, utility AMI networks, payment networks, as well as Original Equipment Manufacturer (EV manufacturer) telematics networks, have designed systems that may work well individually, but no single entity is responsible for the entire ecosystem to be secure in terms of data exchange. Furthermore, there is no uniformity in how each actor has implemented the cybersecurity requirements since no system-wide cybersecurity requirements existed prior to this project. The final project report describes the technical approach guided by the EV charging infrastructure cybersecurity working group, convened specifically for this project. The technical approach included definition of requirements at the ecosystem level, treated as a ‘system of systems’, and then passed down to individual systems (EVSE, EV, cloud EVSP, utility, and the payment networks), followed by developing the cybersecurity risk and vulnerability assessment methods, that were later applied to real-world cyber-physical systems at EPRI, ANL, and NREL laboratories, to validate both the process and the results. Finally, in a spotlight over the most vulnerable equipment, which is the EV charge station (AC or DC), the team developed a multi-layer cybersecurity implementation in the embedded domain embodied by the open-source Secure Network Interface Card (SNIC) demonstrating the various ways in which the infrastructure can be secured protecting against the identified attack surfaces. Finally, the entire process of EV infrastructure cybersecurity assessment was encapsulated in the Electric Vehicle Charging Cybersecurity Management (EVC2M) online GUI-based tool, that is expected to be released to the public. The report presents the objectives, the technical approach, the key results, and recommendations for future work.

24 POWER TRANSMISSION AND DISTRIBUTION↗

EV Charging Infrastructure Energization An Overview of Approaches for Simplifying and Accelerating Timelines to Processing EV Charging Load Service Requests

The United States has seen significant growth in electric vehicle (EV) adoption, leading to increased demand for EV charging infrastructure. Over the past decade, EV charging infrastructure site developers, site hosts, and electric distribution utilities have navigated the process to integrate chargers onto the electric grid. Site developers and site hosts have raised the alarm that the integration process for high-powered EV charging projects does not meet the needs of the EV market for timeliness or cost. High-powered charging stations typically require a load service request or an agreement with the local utility to connect to the grid. The process of energizing a new high-powered charging site can be complex and time-consuming, often taking up to 2 years. This timeline is the result of current utility energization processes having been designed for construction projects that take longer to build (i.e., buildings). The specific challenges stem from various factors, including compartmentalization in application processes, the integration of EV charging process approvals with other distributed energy resources (DERs), and the need to ensure grid reliability. The energization process needs to evolve to meet the growing demand for high-powered EV charging. This white paper compiles information gathered through various conversations with key stakeholders, including utilities, utility regulators, EV charging operators, site developers, and authorities having jurisdiction (AHJ) as well as through an extensive literature review. This document identifies the challenges and provides potential solutions to streamline the process of connecting EV charging infrastructure to the power grid in the United States, serving as a starting point for future conversations around these solutions. The solutions noted in this white paper require collaborative efforts among utilities, regulators, and EV charging infrastructure developers to streamline the grid connection process for EV charging infrastructure. They are broadly organized into four areas: 1. Increase data access and transparency: Develop automated load service request tools, integrate hosting capacity and load service request analyses, incorporate EV adoption forecasts, and provide transparency on the processing queue. 2. Improve energization processes and timing: Create fast-track options based on prescreening criteria, provide flexibility or phased approvals in the load service request/interconnection process, build internal knowledge within utilities about EV charging technologies, and provide standardized workforce training. 3. Promote economic efficiency: Right size distribution components to accurately reflect the load requirements of EV charging infrastructure, make proactive investments in grid infrastructure based on EV adoption forecasts and growth projections, and consider energy equity and environmental justice factors such as equitable access to EV charging when planning infrastructure. 4. Improve grid reliability and resilience: Use load management/power control systems (PCS) at EV charging stations, adopt and implement harmonized standards for communication protocols and information models between the EV charging and grid control infrastructure, and address cybersecurity considerations by implementing robust security measures and standards for EV charging infrastructure—with particular emphasis on clarifying the security requirements for the interface to the grid. The objective of the solutions proposed in this white paper is to accelerate the timeline and decrease costs associated with connecting EV charging infrastructure to the grid. Electric utilities, utility regulators, EV charging infrastructure developers, and site hosts will first need to understand which solutions are available in their service territory, and if warranted, which combination of solutions would support their specific needs. Through the successful implementations of solutions at scale detailed here, industry will demonstrate a new and innovative ecosystem where timely deployment and energization of EV charging infrastructure with greater grid resiliency and reliability is a reality.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Economics of electric vehicle corridor fast charging in the United States

Corridor direct-current fast charging (DCFC) stations enable long-distance electric vehicle travel, yet their economics remain uncertain due to high capital costs, low initial utilization, and exposure to utility demand charges. This study evaluates the long-term economics of corridor DCFC across the United States, incorporating capital and operating expenses-including charging equipment and real-world utility tariffs-alongside modeled station utilization, financial incentives, and ancillary retail revenue. In the Baseline scenario, modeled breakeven costs for corridor DCFC average $\$$0.42/kWh over 20 years, yet fewer than half of stations reach cost parity with gasoline on a per-mile basis. Utilization is the primary driver of cost variation, with low-utilization stations costing roughly six times more per kilowatt-hour than the national average. Excluding stations that fail to reach cost parity reduces National Highway System coverage within 50 miles from 94% to 67%, underscoring the trade-off between market-driven deployment and comprehensive network coverage. These results provide guidance for charging providers, utilities, planners, and policymakers seeking to develop and sustain a financially viable national corridor charging network.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Psyche Gamma-Ray and Neutron Spectrometer

A Gamma-Ray and Neutron Spectrometer (GRNS) instrument has been developed as part of the science payload for NASA’s Discovery Program Psyche mission to the M-class asteroid (16) Psyche. The GRNS instrument is designed to measure the elemental composition of Psyche with the goal to understand the origin of this mysterious, potentially metal-rich planetary body. The GRNS will measure the near-surface abundances for the elements Ni, Fe, Si, K, S, Al, and Ca, as well as the spatial distribution of Psyche’s metal-to-silicate fraction (or metal fraction). These measurements address three of the five Psyche mission science objectives: determine if Psyche is a core; determine whether small metal bodies incorporate light elements into the metal phase; and determine whether Psyche was formed under reducing conditions. The Gamma-Ray Spectrometer (GRS) uses a cryocooled, high-purity Ge (HPGe) sensor to detect cosmic-ray generated gamma rays in the 60 to 9000-keV energy range. The HPGe sensor is surrounded by a borated plastic anticoincidence shield that provides three functions: active background rejection from charged particle interactions in the HPGe sensor; fast neutron measurements; and direct measurements of the incident galactic cosmic ray flux. The Neutron Spectrometer (NS) uses three 3 He gas proportional sensors, each with different material wraps to measure thermal (<0.4 eV), low-energy epithermal (0.4 eV to 1 keV), and high-energy epithermal (up to 100 keV) neutrons. This paper provides an overview of the Psyche GRNS, including: its science and measurement objectives; the design of the instrument hardware, software, and operation; pre-launch performance measurements and its initial performance in space; and an overview of its data products and expected operation for different Psyche mission phases.

Engineering - Instrumentation related to nuclear s↗