Search NASA⌕ Search

SEARCH · Search NASA

Results for “DEGRADATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Atrial natriuretic peptide degradation by CPA47 cells - Evidence for a divalent cation-independent cell-surface proteolytic activity

Atrial natriuretic peptide (ANP) is rapidly cleared and degraded in vivo. Nonguanylate-cyclase receptors (C-ANPR) and a metalloproteinase, neutral endopeptidase (EC 3.4.24.11) (NEP 24.11), are thought to be responsible for its metabolism. We investigated the mechanisms of ANP degradation by an endothelial-derived cell line, CPA47. CPA47 cells degraded 88 percent of 125I-ANP after 1 h at 37 degrees C as determined by HPLC. Medium preconditioned by these cells degraded 41 percent of the 125I-ANP, and this activity was inhibited by a divalent cation chelator, EDTA. Furthermore, a cell-surface proteolytic activity degraded 125I-ANP in the presence of EDTA when receptor-mediated endocytosis was inhibited either by low temperature (4 degrees C) or by hyperosmolarity at 37 degrees C. The metalloproteinase, NEP 24.11, is unlikely to be the cell-surface peptidase because 125I-ANP is degraded by CPA47 cells at 4 degrees C in the presence of 5 mM EDTA. These data indicate that CPA47 cells can degrade ANP by a novel divalent cation-independent cell-surface proteolytic activity.

Frost, S. J.↗

On-Orbit Performance Degradation of the International Space Station P6 Photovoltaic Arrays

This paper discusses the on-orbit performance and performance degradation of the International Space Station P6 solar array wings (SAWs) from the period of December 2000 through February 2003. Data selection considerations and data reduction methods are reviewed along with the approach for calculating array performance degradation based on measured string shunt current levels. Measured degradation rates are compared with those predicted by the computational tool SPACE and prior degradation rates measured with the same SAW technology on the Mir space station. Initial results show that the measured SAW short-circuit current is degrading 0.2 to 0.5 percent per year. This degradation rate is below the predicted rate of 0.8 percent per year and is well within the 3 percent estimated uncertainty in measured SAW current levels. General contributors to SAW degradation are briefly discussed.

Kerslake, Thomas W.↗

Characterization of MODIS Solar Diffuser On-orbit Degradation

MODIS reflective solar bands (RSB) are calibrated on-orbit by a solar diffuser (SD) and a solar diffuser stability monitor (SDSM). The SD bi-directional reflectance factor (BRF) was characterized pre-launch by the instrument vendor using reference samples traceable to NIST reflectance standards. Its on-orbit degradation is regularly monitored by the SDSM. It consists of a solar integration sphere (SIS) with 9 filtered detectors with wavelengths ranging from 0.41 to 0.94 micrometer, a rotating mirror assembly, and an electronics module. During each SD/SDSM calibration, the SDSM views the sunlight directly and the sunlight diffusely reflected from the SD panel. The time series of SDSM measurements (ratio of the SD view response to the Sun view response) is used to compute the SD BRF degradation at each SDSM detector wavelength. Since launch Terra MODIS has operated for more than seven years and Aqua for nearly five years. The SD panel on each MODIS instrument has experienced noticeable degradation with the largest changes observed in the VIS spectral region. Following a brief description of the MODIS RSB calibration methodology and SD/SDSM operational activities, this paper illustrates the SD on-orbit degradation results for both Terra and Aqua MODIS. It discusses the impacts on the SD RF degradation due to sensor operational conditions and SD solar exposure time. For Aqua MODIS, operated under the same conditions, the SD annual degradation rate is approximately 2.9% at 0.41 micrometers, 1.6% at 0.47 micrometers, and less than 1.1% at wavelengths above 0.53 micrometers. For Terra MODIS, however, an SD door (SDD) related anomaly in May 2003 had led to a decision to keep the SDD permanently at its open position. Since then its SD has experienced a much faster SD degradation rate.

Xiong, X.↗

Aboveground Biomass Variability Across Intact and Degraded Forests in the Brazilian Amazon

Deforestation rates have declined in the Brazilian Amazon since 2005, yet degradation from logging, re, and fragmentation has continued in frontier forests. In this study we quantified the aboveground carbon density (ACD) in intact and degraded forests using the largest data set of integrated forest inventory plots (n 359) and airborne lidar data (18,000 ha) assembled to date for the Brazilian Amazon. We developed statistical models relating inventory ACD estimates to lidar metrics that explained70 of the variance across forest types. Airborne lidar-ACD estimates for intact forests ranged between 5.0 +/- 2.5 and 31.9 +/- 10.8 kg C m(exp -2). Degradation carbon losses were large and persistent. Sites that burned multiple times within a decade lost up to 15.0 +/- 0.7 kg C m(-2)(94%) of ACD. Forests that burned nearly15 years ago had between 4.1 +/- 0.5 and 6.8 +/- 0.3 kg C m(exp -2) (22-40%) less ACD than intact forests. Even for low-impact logging disturbances, ACD was between 0.7 +/- 0.3 and 4.4 +/- 0.4 kg C m(exp -2)(4-21%) lower than unlogged forests. Comparing biomass estimates from airborne lidar to existing biomass maps, we found that regional and pan-tropical products consistently overestimated ACD in degraded forests, under-estimated ACD in intact forests, and showed little sensitivity to res and logging. Fine-scale heterogeneity in ACD across intact and degraded forests highlights the benefits of airborne lidar for carbon mapping. Differences between airborne lidar and regional biomass maps underscore the need to improve and update biomass estimates for dynamic land use frontiers, to better characterize deforestation and degradation carbon emissions for regional carbon budgets and Reduce Emissions from Deforestation and forest Degradation(REDD+).

Longo, Marcos↗

Reductions in Productivity Due to Land Degradation in the Drylands of the Southwestern United States

Dryland degradation has long been recognized at regional, national, and global scales, yet there are no objective assessments of its location and severity. An assessment of reductions in net primary production (NPP) due to dryland degradation in the southwestern United States is reported. The local NPP scaling (LNS) approach was applied to map the extent and magnitude of degradation. LNS seeks to identify reference sites in which there is no degradation that can be used as a standard for comparison with other sites that share the same environment, except for degradation. Twelve years were analyzed (2000–2011), using Normalized Difference Vegetation Index (NDVI) data (250 m) from the Moderate Resolution Imaging Spectroradiometer (MODIS) satellite‐borne multispectral sensor. The results indicated that the total NPP reductions in the study area were about 35.9 ± 4.7 Tg C/yr, which equates to 0.31 ± 0.04 Mg C/ha·y. The NPP reductions in grassland‐savanna and livestock grazing areas were large and mostly consistent between years in spite of large variations in overall NPP caused by differences in land‐use, interannual variations in rainfall, and other aspects of weather. In comparison with other cover types, forested land generally had higher NPP reduction per unit area. The maps also enable attribution of degradation from the finest management units to entire agencies, such as the Bureau of Land Management, which had 50% less production per unit area than the U.S. Forest Service. The degradation within Native American land was low with total NPP reduction of about 2.41 ± 0.24 Tg C/yr and unit area reduction of productivity of just 0.21 ± 0.02 Mg C/ha·yr, yet the percent reduction from potential was in equivalence with other land management agencies.

Noojipady, Praveen↗

Using Degradation Modeling to Identify Fragile Operational Conditions in Human- and Component-driven Resilience Assessment

Studying failure events shows that many high-impact events result from the complex interactions between precipitating failure events and degraded operational conditions. Often, when a system is put in operations, unforeseen practical realities (e.g., maintenance and/or workforce availability) lead the system to be operated in configurations outside its envisioned nominal range. However, design-time failure models often assume that the failure events are initiated in an idealized, nominal state of system operation, resulting in an incomplete assessment of future risk. To solve this, this paper develops a framework to consider degraded operational performance in scenario-based resilience models which uses a corresponding model of performance degradation to determine the values of deteriorated model parameters in the resilience model. This framework is demonstrated on a remotely-piloted rover to determine the (individual and combined) effect of drive-train wear and operator fatigue on the resilience of the rover to drive-train faults. This demonstration showed the substantial impact that degradation has on resilience, highlighting the need to account for degradation in resilience models--specifically, unconsidered degradation can lead to overestimates of resilience (and thus underestimates of safety margin) and because resilience can degrade prior to visible unreliability, which can lead to an operational environment with a high propensity for high-impact unforeseen failure events.

Daniel Hulse↗

Determining the Crosslinking and Degradation Reaction Kinetics in Photovoltaic Encapsulants Using Accelerated Aging: Preprint

Degradation of photovoltaic (PV) module encapsulant mechanical characteristics that lead to embrittlement and delamination remains a cause of failure in solar installations. A multiscale reliability model based on detailed molecular degradation reaction kinetics was previously published, connecting the encapsulant mechanical properties (elastic modulus, yield strength, and adhesion energy) to the degraded molecular structure and interfacial bond density to adjacent solar cell and glass substrates. The model, developed primarily for poly(ethylene-co-vinyl acetate) (EVA) encapsulants, remains to be experimentally validated. Determining the degradation and crosslinking kinetics of alternative encapsulants, such as polyolefin elastomer (POE) and EVA/POE/EVA composites (EPE), can further generalize the model. Importantly, the activation energy for crosslinking of fully cured PV encapsulant products from temperature or UV is presently unknown or unavailable. In this work, we subject EVA, POE, and EPE encapsulants to a set of accelerated aging conditions, varying the temperature, UV intensity, and relative humidity. We use DSC, FTIR, and Soxhlet extraction (gel content) to characterize the encapsulants' changing molecular structure. This allows for determination of the photochemical degradation and crosslinking kinetics of the encapsulants. Preliminary results show an increase in gel content (crosslinking) and a decrease in crystallinity of EVA, POE, and EPE encapsulants under hot-aerobic (90 deg C, 22% RH) and hot-anaerobic (90oC, sealed in N2 air) accelerated aging, even in the absence of UV and crosslinking initiating agents. For a least squares regression with an assumed first-order crosslinking kinetics, the crosslinking rate parameters were computed for the three encapsulants under hot-aerobic and hot-anaerobic aging conditions. FTIR analysis showed insignificant encapsulant degradation for hot-aerobic and hot-anaerobic aging, demonstrating the critical role of UV and moisture in accelerating degradation. Aging conditions with UV exposure and elevated humidity are presently in progress.

adhesion↗

Evidence of Polarization‐Type Potential‐Induced Degradation (PID‐p) in the Field and Investigation of the Recovery Mechanism on Bifacial p ‐PERC Modules

This study investigates the polarization-type potential-induced degradation (PID-p) of bifacial glass/glass p-type passivated emitter rear contact (p-PERC) modules in the field and their recovery behavior. Modules were installed with three mounting configurations providing different albedo conditions. System voltage (–600, –1500, and +1500 V) was applied to the cell circuits, with respect to the grounded module frames. No degradation was observed for positively biased modules, but PID-p was identified on the rear side when cells are negatively biased, with maximum power dropping during the first days and stabilizing at values up to 8% loss. Electroluminescence images revealed a variation of the cells' PID-p susceptibility within a module. Three parameters were shown to impact the degradation rate: rear albedo light, voltage, and wetness conditions. Degraded modules were recovered either by (1) a positive bias (+1500 V), (2) outdoor illumination with the front side facing sun, (3) outdoor illumination with the rear side facing sun, or (4) dark storage. A recovery pattern was identified with I–V parameters decreasing to a local minimum before increasing to full recovery. The proposed mechanism is based on the band bending at the rear p-type Si/AlO x/SiN x interface, going from inversion to depletion and accumulation states. Full recovery was achieved in 2–7 h for the modules recovered with the rear side facing sun, four to eight nights for the modules positively biased at night, and 10–20 days for the modules with the front side facing sun. Dark storage showed slower recovery rates as I–V parameters were not improving even after 1 month. Here, the recovery rates were correlated with the net Coulombs transferred during the preceding PID stress: When more Coulombs are transferred during the degradation, the extent of degradation is greater, leading to slower recovery rates.

14 SOLAR ENERGY↗

Degradation and Accelerated Recovery of Surface Passivation in n+, p+, and Intrinsic Poly-Si/SiOx Passivating Contacts for Silicon Solar Cells

We report on the degradation and recovery of surface passivation of fired poly-Si/SiOx passivating contacts with hydrogen containing Al2O3 during annealing in the dark and under illumination. Upon firing to a peak temperature of 670 degrees C, the iVoc for symmetric test structures with n+, p+, and intrinsic poly-Si/SiOx contacts decreases due to a loss of surface passivation. Upon further annealing over the temperature range of 200-350 degrees C in the dark, depending on the type of doping, the surface passivation either shows further degradation followed by recovery, or direct recovery to the initial iVoc. Annealing at higher temperatures and/or higher illumination intensities accelerates the kinetics for both degradation and recovery processes. We show that the degradation and recovery processes are thermally activated and proceed identically in subsequent firing and annealing steps showing their cyclic nature. We present a series reaction model to explain the kinetics of degradation and recovery processes for n+ and intrinsic poly-Si/SiOx contacts. By fitting the model's rate expressions to the data, the determined effective activation energy barriers for degradation and recovery for n+ poly-Si/SiOx contacts in the dark are 1.24 and 1.51 eV, which are lowered under 7.5 Suns illumination to 0.76 and 1.15 eV, respectively.

14 SOLAR ENERGY↗

Degradation Dynamics of Perovskite Solar Cells Under Fixed Reverse-Current Injection

Previous studies of reverse-bias stability in perovskite solar cells have focused primarily on voltage-controlled tests. Here we instead investigate perovskite solar cell degradation under well-defined, constant reverse-current stress. We show that the choice of hole-transport layer dictates the dominant degradation pathway: cells using thick poly(triphenylamine) (PTAA) layers can tolerate high reverse bias but quickly undergo catastrophic breakdown under fixed reverse current near their one-sun maximum power-point. In contrast, cells modified with phosphonic-acid interface layer MeO-2PACz, with poorer indium-doped tin oxide (ITO) coverage compared to PTAA, exhibit gradual and recoverable degradation under certain stress and recovery conditions. For MeO-2PACz devices, degradation increases with both current magnitude and duration. Importantly, when normalized by injected charge (current times duration), lower currents applied over longer times cause more degradation than higher currents over shorter periods. Here, combining electrical measurements with spatially resolved photoluminescence imaging, our observations support an ion- and charge-mediated interfacial electrochemical degradation mode.

Degradation↗

Degradation Mode Identification by Photocarrier Lifetime Spectroscopy on Devices and Test Structures

In this presentation, I examine the basic concepts of the device physics that can be used to distinguish various degradation and recovery modes on a cell level. The known degradation modes (bulk LeTID and LID, UVID, etc.) are due to defects and impurities that cause the photocarrier recombination according to Shockley-Reed-Hall (SRH) statistics. The SRH recombination rate strongly depends on the balance of electron and hole capture rates into the defects, which in turn, are governed by their local concentrations. The strongest recombination takes place at approximately equal concentrations of electrons and holes, while at low injection conditions (when one type of carrier dominates) the SRH recombination is suppressed. For cell degradation modes that affect the passivated interface (UVID, H-induced TOPCon contact degradation) the defects are at the interface under low-injection conditions due to either high local doping or the adjacent built-in charge in the dielectric. This mode is characterized by changes in the "diode prefactor" J01 slope in the inverse lifetime-injection level curve. In contrast, bulk degradation (LeTID, LID) affects bulk lifetime, with J01 slope unchanged. Carrier lifetime - injection level plots therefore serve as clear indicators of different degradation modes and are shown by experimental examples.

14 SOLAR ENERGY↗

Elucidate the Thermal Degradation Mechanism of Y6‐Based Organic Solar Cells by Establishing Structure‐Property Correlation

Abstract Organic solar cells (OSCs) achieved performance booming benefiting from the emerging of non‐fullerene acceptors, while inadequate device stability hampers their further application. At present, the prevalent belief attributes the inevitable thermal degradation of OSC device to morphological instability caused by excessive phase separation and crystallization in the active layer during device operation. However, it is inapplicable for state‐of‐art Y6‐based devices which strongly degrade before large‐scale morphology change. Herein, an alternative degradation mechanism is elucidated wherein molecular orientation change and demixing induced performance degradation in Y6‐based devices. Distinct from IT‐4F‐based counterpart, Y6‐based devices suffer severe thermal degradation dominated by open‐circuit voltage (V OC ) and fill factor (FF) losses. TheV OC loss is attributed to molecular orientation transition of polymer donors from edge‐on to face‐on, leading to a strong built‐in potential reduction and increase in non‐radiative loss due to energy level shifting. As forFFdecay, discontinuous acceptor phases result in electron mobility decrease by over orders of magnitude, originating from the increased molecular stacking and phase separation. This work reveals the thermal degradation mechanism for Y6‐based devices and correlates the photoelectric properties with morphology instability, which will offer guidance for improving the stability of high‐performance OSCs.

Chemistry↗

Power modeling of degraded PV systems: Case studies using a dynamically updated physical model (PV-Pro)

Power modeling, widely applied for health monitoring and power prediction, is crucial for the efficiency and reliability of Photovoltaic (PV) systems. The most common approach for power modeling uses a physical equivalent circuit model, with the core challenge being the estimation of model parameters. Traditional parameter estimation either relies on datasheet information, which does not reflect the system's current health status, especially for degraded PV systems, or requires additional I-V characterization, which is generally unavailable for large-scale PV systems. Thus, we build upon our previously developed tool, PV-Pro (originally proposed for degradation analysis), to enhance its application for power modeling of degraded PV systems. PV-Pro extracts model parameters from production data without requiring I-V characterization. This dynamic model, periodically updated, can closely capture the actual degradation status, enabling precise power modeling. PV-Pro is compared with popular power modeling techniques, including persistence, nominal physical, and various machine learning models. The results indicate that PV-Pro achieves outstanding power modeling performance, with an average nMAE of 1.4 % across four field-degraded PV systems, reducing error by 17.6 % compared to the best alternative technique. Furthermore, PV-Pro demonstrates robustness across different seasons and severities of degradation. The tool is available as a Python package at https://github.com/DuraMAT/pvpro.

14 SOLAR ENERGY↗

Multivariate degradation modeling using generalized cauchy process and application in life prediction of dye-sensitized solar cells

Recently, the Generalized Cauchy (GC) process has been applied to capture a Long Memory (LM) phenomenon in product degradation modeling and life prediction. Compared with the traditional fractional Brownian motion that captures the LM using a single Hurst parameter, the GC process has two free parameters (Hurst and fractal dimension parameters) that flexibly capture both global LM and local irregularity. However, all existing GC-based degradation models are for a single Degradation Characteristic (DC). In this article, motivated by a real degradation problem of dye-sensitized solar cells that jointly exhibits multiple DCs, global LM, local irregularity and DC-wise cross-correlation, we propose a novel GC-based Multivariate Degradation Model (GC-MDM) to simultaneously capture the aforementioned effects. A maximum likelihood estimation approach is developed to estimate parameters of the GC-MDM. Subsequently, product life prediction based on the GC-MDM is developed. The proposed GC-MDM is validated through a simulation study and a physical experiment of dye-sensitized solar cells. Furthermore, results show that the proposed GC-MDM fundamentally improves the life prediction accuracy in comparison with conventional degradation models which significantly misestimate the uncertainty of product life.

14 SOLAR ENERGY↗

Kinetic Monte Carlo Framework for Coupled Degradation and Dehydration of Anion Exchange Membranes

Kinetic Monte Carlo (kMC) simulations, augmented with temporal-acceleration schemes, can efficiently handle stiff reaction-transport networks when fast processes rapidly relax to quasi-equilibrium on a fixed lattice. However, in glassy anion-exchange membranes (AEM), rare and irreversible chemical degradation events continuously reshape the nanoscale morphology, and the associated hydration and transport degrees of freedom remain far from a well-defined local equilibrium. This combination of evolving state space and nonequilibrated fast dynamics lies outside the scope of existing kMC acceleration frameworks. Here, to address this challenge, we introduce an auxiliary-particle kinetic Monte Carlo (AP-kMC) scheme. In AP-kMC, short-lived mobile particles spawned at degradation sites execute hop, water-elimination, and decay moves, enforcing rapid local relaxation of the hydration structure while preserving the stochastic rules of kMC. Parameterized with molecular-dynamics morphologies and experimental solution degradation kinetics, AP-kMC reproduces the evolution of ion-exchange capacity, water uptake, and conductivity, and reveals a feedback loop in which poorly hydrated sites degrade first and each degradation event induces further local dehydration. The resulting thinning and fragmentation of water channels cause loss of hydrophilic percolation and abrupt conductivity collapse well before complete charge loss. AP-kMC thus reframes AEM durability as a coupled degradation–drying–percolation problem and provides a transferable strategy to simulate reactive, out-of-equilibrium polymer electrolytes where local solvation controls reactivity.

organic↗

Degradation of Anion Exchange Membranes by Cation Elimination: Impact on Water Uptake, Nanostructure, and Ionic Mobility

Anion exchange membranes (AEMs) are an attractive platform for fuel cell and electrolysis technologies since they enable the use of cheaper, nonplatinum group metal electrodes and components. However, the widespread adoption of AEM-based devices is limited by chemical degradation of the AEM in the highly alkaline medium of operation. Experimental studies report three major pathways of degradation, including substitution (S N 2), elimination (E2), and backbone cleavage. The decline in membrane performance is likely due to a cumulative effect of several pathways, which has proven to be difficult to disentangle through experiments. Here we use coarse-grained molecular simulations to isolate the impact of E2 degradation, where cationic sites are replaced by an alkene group, on AEM water uptake, nanoscale morphology, structure of the ion-conducting channels, water mobility, and ionic conductivity. Our studies focus on the well-studied model AEM polyphenylene oxide with tetraalkylammonium cationic sites (PPO-TMA). We find that about half of the hydrophobic groups resulting from the degradation retract into the hydrophobic domains of the membrane. The reduction in ion exchange capacity (IEC) and the hydrophobicity of the alkene groups decrease both the equilibrium water uptake (%WU) and the number of water molecules per cation (λ) of the membrane. Interestingly, the evolution of λ with the IEC seems to follow that of undegraded PPO-TMA membranes. Additionally, we ascribe this to the similarity between the structure of the degraded monomer and the neutral one in the polymer. We conclude that most of the performance losses originate in the lower hydration of the degraded membrane.

36 MATERIALS SCIENCE↗

Capacity of Arctic fjord sediments to degrade carbohydrates from permafrost active layer

The degradation of organic matter (OM) by microorganisms in thawing permafrost produces greenhouse gases. Terrestrial OM is transported into fjords through hydrological runoff, but it is unclear whether the microbial mechanisms of OM degradation on land persist after soils enter marine environments, which differ greatly in conditions and microbial communities. This question is particularly relevant for low-OM soils, which dominate Arctic landscapes and are more exposed to oxidants. Here, we compared OM-degrading capacity in permafrost-affected active layer soils and adjacent fjord sediments from Kongsfjorden, Svalbard, focusing on carbohydrate-active enzymes (CAZymes), which target some of the most abundant types of organic matter in soils. Using multi-omics approaches—metagenomics, metagenome-assembled genomes (MAGs), metabolomics, metatranscriptomics, and metaproteomics—we examined CAZyme presence, distribution, and activity. Despite environmental differences, both soils and sediments harbored diverse glycoside hydrolases and polysaccharide lyases, most of which showed evidence of activity. Verrucomicrobia expressed the highest number of CAZyme transcripts, indicating that they dominated active carbohydrate degradation in fjord sediments, while Acidobacteria and Actinobacteria were more active in soils. Notably, CAZymes in fjord sediments targeted primarily soil-derived OM, and the proportions of enzymes degrading terrestrial OM, marine OM, and microbial necromass—remnants of dead microbial cells were similar across both environments. These results suggest that microbial communities in both soils and fjord sediments are equipped to degrade carbohydrates, and that burial of terrestrial-derived OM in fjord sediments may not protect it from microbial breakdown under Arctic warming.

Chukwufumnanya, Abuah [University of Tennessee, Kn↗

First degraded beams in the CEBAF injector

The electron beam degrader in the Continuous Electron Beam Accelerator Facility (CEBAF) injector at Jefferson Lab serves to generate electron beams with transverse emittance over 10x the nominal values, with the ultimate goal of using degraded electron beams to measure machine acceptance. Electron beams are degraded through multiple scattering in thin carbon foils, and maximum transverse emittance is defined through two collimating apertures. The degrader device was installed in late 2024, with commissioning and first beams on degrader targets during the 2025 physics run. We report on first operation of the degrader device. This material is based upon work supported by the U.S. Department of Energy, Office of Science, Office of Nuclear Physics under contract DE-AC05-06OR23177.

Sy, A. [Thomas Jefferson National Accelerator Faci↗