Search NASA⌕ Search

SEARCH · Search NASA

Results for “DELTA MODULATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Electronic Structure of the Cuprate Superconducting and Pseudogap Phases from Spectroscopic Imaging STM

We survey the use of spectroscopic imaging scanning tunneling microscopy (SI-STM) to probe the electronic structure of underdoped cuprates. Two distinct classes of electronic states are observed in both the d-wave superconducting (dSC) and the pseudogap (PG) phases. The first class consists of the dispersive Bogoliubov quasiparticle excitations of a homogeneous d-wave superconductor, existing below a lower energy scale E = {Delta}{sub 0}. We find that the Bogoliubov quasiparticle interference (QPI) signatures of delocalized Cooper pairing are restricted to a k-space arc, which terminates near the lines connecting k = {+-}({pi}/a{sub 0},0) to k = {+-}(0,{pi}/a{sub 0}). This arc shrinks continuously with decreasing hole density such that Luttinger's theorem could be satisfied if it represents the front side of a hole-pocket that is bounded behind by the lines between k = {+-}({pi}/a{sub 0},0) and k = {+-}(0,{pi}/a{sub 0}). In both phases, the only broken symmetries detected for the |E| < {Delta}{sub 0} states are those of a d-wave superconductor. The second class of states occurs proximate to the PG energy scale E = {Delta}{sub 1}. Here the non-dispersive electronic structure breaks the expected 90{sup o}-rotational symmetry of electronic structure within each unit cell, at least down to 180{sup o}-rotational symmetry. This electronic symmetry breaking was first detected as an electronic inequivalence at the two oxygen sites within each unit cell by using a measure of nematic (C{sub 2}) symmetry. Incommensurate non-dispersive conductance modulations, locally breaking both rotational and translational symmetries, coexist with this intra-unit-cell electronic symmetry breaking at E = {Delta}{sub 1}. Their characteristic wavevector Q is determined by the k-space points where Bogoliubov QPI terminates and therefore changes continuously with doping. The distinct broken electronic symmetry states (intra-unit-cell and finite Q) coexisting at E {approx} {Delta}{sub 1} are found to be indistinguishable in the dSC and PG phases. The next challenge for SI-STM studies is to determine the relationship of the E {approx} {Delta}{sub 1} broken symmetry electronic states with the PG phase, and with the E < {Delta}{sub 0} states associated with Cooper pairing.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Measurements and modeling of Alfven eigenmode induced fast ion transport and loss in DIII-D and ASDEX Upgrade

Neutral beam injection into reversed magnetic shear DIII-D and ASDEX Upgrade plasmas produces a variety of Alfvenic activity including toroidicity-induced Alfven eigenmodes and reversed shear Alfven eigenmodes (RSAEs). These modes are studied during the discharge current ramp phase when incomplete current penetration results in a high central safety factor and increased drive due to multiple higher order resonances. Scans of injected 80 keV neutral beam power on DIII-D showed a transition from classical to AE dominated fast ion transport and, as previously found, discharges with strong AE activity exhibit a deficit in neutron emission relative to classical predictions. By keeping beam power constant and delaying injection during the current ramp, AE activity was reduced or eliminated and a significant improvement in fast ion confinement observed. Similarly, experiments in ASDEX Upgrade using early 60 keV neutral beam injection drove multiple unstable RSAEs. Periods of strong RSAE activity are accompanied by a large (peak {delta}S{sub n}/S{sub n{approx_equal}}60%) neutron deficit. Losses of beam ions modulated at AE frequencies were observed using large bandwidth energy and pitch resolving fast ion loss scintillator detectors and clearly identify their role in the process. Modeling of DIII-D loss measurements using guiding center following codes to track particles in the presence of ideal magnetohydrodynamic (MHD) calculated AE structures (validated by comparison to experiment) is able to reproduce the dominant energy, pitch, and temporal evolution of these losses. While loss of both co and counter current fast ions occurs, simulations show that the dominant loss mechanism observed is the mode induced transition of counter-passing fast ions to lost trapped orbits. Modeling also reproduces a coherent signature of AE induced losses and it was found that these coherent losses scale proportionally with the amplitude; an additional incoherent contribution scales quadratically with the mode amplitude.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

STM Studies of Near-Optimal Doped Bi_2Sr_2CaCu_2O_8 delta

In this paper we summarize our STM studies of the density of electronic states in nearly optimally doped Bi{sub 2}Sr{sub 2}CaCu{sub 2}O{sub 8 + {delta}} in zero field. We report on the inhomogeneity of the gap structure, density of states modulations with four-lattice constant period, and coherence peak modulation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of pseudo-random binary arrays for calibration of surface profile metrology tools

Optical Metrology tools, especially for short wavelength (EUV and X-Ray), must cover a wide range of spatial frequencies from the very low, which affects figure, to the important mid-spatial frequencies and the high spatial frequency range, which produces undesirable scattering. A major difficulty in using surface profilometers arises due to the unknown Point-Spread Function (PSF) of the instruments [1] that is responsible for distortion of the measured surface profile. Generally, the distortion due to the PSF is difficult to account because the PSF is a complex function that comes to the measurement via the convolution operation, while the measured profile is described with a real function. Accounting for instrumental PSF becomes significantly simpler if the result of measurement of a profile is presented in a spatial frequency domain as a Power Spectral Density (PSD) distribution [2]. For example, the measured PSD distributions provide a closed set of data necessary for three-dimensional calculations of scattering of light by the optical surfaces [3], [4]. The distortion of the surface PSD distribution due to the PSF can be modeled with the Modulation Transfer Function (MTF), which is defined over the spatial frequency bandwidth of the instrument [1], [2]. The measured PSD distribution can be presented as a product of the squared MTF and the ideal PSD distribution inherent for the System Under Test (SUT). Therefore, the instrumental MTF can be evaluated by comparing a measured PSD distribution of a known test surface with the corresponding ideal numerically simulated PSD. The square root of the ratio of the measured and simulated PSD distributions gives the MTF of the instrument. In previous work [5], [6] the instrumental MTF of a surface profiler was precisely measured using reference test surfaces based on Binary Pseudo-Random (BPR) gratings. Here, we present results of fabricating and using two-dimensional (2D) BPR arrays that allow for a direct 2D calibration of the instrumental MTF. BPR sequences are widely used in engineering and communication applications such as Global Position System, and wireless communication protocols. The ideal BPR pattern has a flat 'white noise' response over the entire range of spatial frequencies of interest. The BPR array used here is based on the Uniformly Redundant Array prescription [7] initially used for x-ray and gamma ray astronomy applications. The URA's superior imaging capability originates from the fact that its cyclical autocorrelation function very closely approximates a delta function, which produces a flat PSD. Three different size BPR array patterns were fabricated by electron beam lithography and ICP etching of silicon. The basic size unit was 200 nm, 400 nm, and 600 nm. Two different etch processes were used, CF{sub 4}/Ar and HBr, which resulted in undercut and vertical sidewall profiles, respectively. The 2D BPR arrays were used as standard test surfaces for MTF calibration of the MicroMap{trademark}-570 interferometric microscope using all available objectives. The HBr etched two-dimensional BPR arrays have proven to be a very effective calibration standard making possible direct calibration corrections without the need of additional calculation considerations, while departures from the ideal vertical sidewall require an additional correction term for the CF{sub 4}/Ar etched samples. [8] Initial surface roughness of low cost 'prime' wafers limits low magnification calibration but should not be a limitation if better polished samples are used.

36 MATERIALS SCIENCE↗

Production of extended plasma channels in atmospheric air by amplitude-modulated UV radiation of GARPUN-MTW Ti : sapphire-KrF laser. Part 1. Regenerative amplification of subpicosecond pulses in a wide-aperture electron beam pumped KrF amplifier

Regenerative amplification of single and multiple ultrashort subpicosecond UV pulses in a wide-aperture KrF amplifier with an unstable confocal resonator was investigated on the GARPUN-MTW hybrid laser system. Amplitude-modulated 100-ns long UV radiation pulses with an energy of several tens of joules were obtained at the output of the system. The pulses were a combination of a quasi-stationary oscillation pulse and a train of amplified ultrashort pulses (USPs) with a peak power of 0.2-0.3 TW, which exceeded the power of free-running lasing pulse by three orders of magnitude. The population inversion recovery time in the active KrF laser medium was estimated: {tau}{sub c} {<=} 2.0 ns. Trains of USPs spaced at an interval {Delta}t Almost-Equal-To {tau}{sub c} were shown to exhibit the highest amplification efficiency. The production of amplitude-modulated UV pulses opens up the way to the production and maintenance of extended plasma channels in atmospheric air. (extreme light fields and their applications)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of pseudo-random binary gratings and arrays for calibration of surface profile metrology tools

Optical Metrology tools, especially for short wavelength (EUV and X-Ray), must cover a wide range of spatial frequencies from the very low, which affects figure, to the important mid-spatial frequencies and the high spatial frequency range, which produces undesirable flair. A major difficulty in using surface profilometers arises due to the unknown Modulation Transfer Function (MTF) of the instruments. Therefore, accurate calibration of profilometers, the understanding of their MTF limitations, and cross calibration between tools represents a considerable challenge for quantitative optical metrology. In previous work the instrumental MTF of a surface profiler was precisely measured using reference test surfaces based on binary pseudo-random (BPR) gratings. Here, they present results of fabricating and using two-dimensional (2D) BPR arrays that allow for a direct 2D calibration of the instrumental MTF. BPR sequences are widely used in engineering and communication applications such as Global Position System, and wireless communication protocol. The ideal BPR pattern has a flat 'white noise' response over the entire range of spatial frequencies of interest. The BPR array used here is based on the Uniformly Redundant Array prescription initially used for x-ray and gamma ray astronomy applications. The URA's superior imaging capability originates from the fact that its cyclical autocorrelation function very closely approximates a delta function, which produces a flat Power Spectrum Density (PSD). Three different BPR array patterns were fabricated by electron beam lithography and ICP etching of silicon. The basic size unit was 200 nm, 400 nm, and 600 nm. Figure 1 shows the fabrication sequence. The 2D BPR arrays were used as standard test surfaces for MTF calibration of the MicroMap{trademark}-570 interferometric microscope with all available objectives. Figure 2 shows representative scanning probe height data for the 400 nm BPR sample. Figure 2 shows the raw Power Spectral Density for 5 different objectives. They demonstrate that the two dimensional BPR array is a very effective calibration standard. However, departures from ideal, such as square sidewall, and uniform etch depth ultimately can limit the accuracy of the calibration. The effects of fabrication imperfections on the efficiency of calibration will be discussed.

36 MATERIALS SCIENCE↗

Photoreflectance spectroscopy of electron-hole states in a graded-width GaAs/InGaAs/GaAs quantum well

The spectrum of electron-hole states in a GaAs/In{sub 0.5}Ga{sub 0.5}As quantum well with a width graded in the range from 1.1 to 3.6 nm is studied by photoreflectance spectroscopy. The energies of the size-quantization levels of electrons and holes are calculated taking into account the strain-induced changes in the band structures of the quantum well. It is shown that the best fit of the experimental data to the results of calculations is attained if the ratio between the offset of the conduction band and that of the valence band at the heterojunction is Q = {Delta}E{sub c}/{Delta}E{sub v} = 0.62/0.38. A photoreflectance signal is detected in the region of the shadow of modulating radiation beam at a spacing between the spots produced by probing and modulating radiation shorter than 6 mm.

36 MATERIALS SCIENCE↗

Poster — Thur Eve — 39: Feasibility of Commissioning HybridArc with the Delta 4 two plane diode phantom: comparisons with Gafchromic Film

HybridArc is a relatively novel radiation therapy technique which combines optimized dynamic conformai arcs (DCA) and intensity modulated radiation therapy (IMRT). HybridArc has possible dosimetry and efficiency advantages over stand alone DCA and IMRT treatments and can be readily implemented on any linac capable of DCA and IMRT, giving strong motivation to commission the modality. The Delta4 phantom (Scandidos, Uppsala, Sweden) has been used for IMRT and VMAT clinical dosimetric verification making it a candidate for HybridArc commissioning. However the HybridArc modality makes use of several non co-planar arcs which creates setup issues due to the geometry of the Delta4, resulting in possible phantom gantry collisions for plans with non-zero couch angles. An analysis was done determining the feasibility of using the Delta4 fixed at 0° couch angle compared with results obtained using Gafchromic ETB2 film (Ashland, Covington Kentucky) in an anthropomorphic phantom at the planned couch angles. A gamma index analysis of the measured and planned dose distributions was done using Delta4 and DoseLab Pro (Mobius Medical Systems, Houston Texas) software. For both arc and IMRT sub-fields there is reasonable correlation between the gamma index found from the Delta4 and Gafchromic film. All results show the feasibility of using the Delta4 for HybridArc commissioning.

60 APPLIED LIFE SCIENCES↗

The Structure of the MAP2K MEK6 Reveals an Autoinhibitory Dimer

MAP2Ks are dual-specificity protein kinases functioning at the center of three-tiered MAP kinase modules. The structure of the kinase domain of the MAP2K MEK6 with phosphorylation site mimetic aspartic acid mutations (MEK6/{Delta}N/DD) has been solved at 2.3 {angstrom} resolution. The structure reveals an autoinhibited elongated ellipsoidal dimer. The enzyme adopts an inactive conformation, based upon structural queues, despite the phosphomimetic mutations. Gel filtration and small-angle X-ray scattering analysis confirm that the crystallographically observed ellipsoidal dimer is a feature of MEK6/{Delta}N/DD and full-length unphosphorylated wild-type MEK6 in solution. The interface includes the phosphate binding ribbon of each subunit, part of the activation loop, and a rare 'arginine stack' between symmetry-related arginine residues in the N-terminal lobe. The autoinhibited structure likely confers specificity on active MAP2Ks. The dimer may also serve the function in unphosphorylated MEK6 of preventing activation loop phosphorylation by inappropriate kinases.

59 BASIC BIOLOGICAL SCIENCES↗

Zeeman polarimetry measurement for edge current density determination using Li-beam probe on JT-60U

Zeeman polarimetry system using Li-beam probe has been developed for the edge current density measurement in the JT-60U tokamak, which measures the polarization angle {alpha} (related to the pitch angle of the magnetic field) by means of photoelastic modulators, etalons, and phase sensitive detection using digital lock-in amplifiers with the accuracy in the {alpha} of {Delta}{alpha}{approx}0.1 deg. The diagnostic has 20-channel viewing chords covering the plasma peripheral region of normalized minor radius r/a{approx}0.8-1 with a spatial resolution of up to {approx}1 cm. Li-beam injection with beam current of up to {approx}5 mA has been achieved. A new tuning method of the wavelength for the etalon has been demonstrated, scanning the beam acceleration voltage and keeping a beam current constant during a single shot. The peak wavelength of the etalon is adjusted in the direction to both blue- and redshifts by changing the angle of incidence and increasing the temperature, respectively. Time evolution of the edge current density profile has been determined for the current ramp experiment in the Ohmically heated discharges. In addition, the edge current density profile with the local peak of j{sub ped}{approx}0.15-0.25 MA/m{sup 2} at r/a{approx}0.9 has been identified in the H-mode plasma, which is correlated with large pressure gradient in the pedestal region.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Phase-Separated, Epitaxial, Nanostructured LaMnO 3 +MgO Composite Cap Layer Films for Propagation of Pinning Defects in YBa 2 Cu 3 O 7-x Coated Conductors

Nanostructural modulation in the cap layer used in coated conductors can be a potential source for nucleating microstructural defects into the superconducting layer for improving the flux-pinning. We report on the successful fabrication of phase separated, epitaxial, nanostructured films comprised of LaMnO{sub 3} (LMO) and MgO via pulsed laser deposition (PLD) on biaxially-textured MgO metallic templates with a LMO buffer layer. Scanning Auger compositional mapping and transmission electron microscopy cross sectional images confirm the nanoscale, spatial modulation corresponding to the nanostructured phase separation in the film. YBa{sub 2}Cu{sub 3}O{sub 7-{delta}} films (0.8 {micro}m thick) grown using PLD on such phase separated, nanostructured cap layers show reduced field dependence of the critical current density with an ? value of -0.38 (in J{sub c}-H{sup -{alpha}}).

36 MATERIALS SCIENCE↗

A multichannel, frequency-modulated, tunable Doppler backscattering and reflectometry system

A novel multichannel Doppler backscattering system has been designed and tested for application on the DIII-D [J. L. Luxon, Fusion Sci. Technol. 48, 828 (2005)] and National Spherical Torus Experiment (NSTX) [M. Ono et al., Nucl. Fusion 40, 557 (2000)] fusion plasma devices. Doppler backscattering measures localized intermediate wavenumber (k{sub perpendicular}{rho}{sub i}{approx}1-4,k{sub perpendicular}{approx}2-15 cm{sup -1}) density fluctuations and the propagation velocity of turbulent structures. Microwave radiation is launched at a frequency that approaches a cutoff layer in the plasma and at an angle that is oblique to the cutoff layer. Bragg backscattering occurs near the cutoff layer for fluctuations with k{sub perpendicular}{approx_equal}-2k{sub i}, where k{sub i} is the incident probe wave vector at the scattering location. The turbulence propagation velocity can be determined from the Doppler shift in the return signal together with knowledge of the scattering wavenumber. Ray tracing simulations are used to determine k{sub perpendicular} and the scattering location. Frequency modulation of a voltage-controlled solid state microwave source followed by frequency multiplication is used to create an array of finely spaced ({Delta}f=350 MHz) frequencies spanning 1.4 GHz. The center of the array bandwidth is tunable within the range of {approx}53-78 GHz. This article details the system design, laboratory tests, and presents initial data from DIII-D plasmas.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Superconducting properties of YaBa 2 Cu 3 O 7-delta films deposited on commercial tape substrates, decorated with Pd or Ta nano-islands

To obtain an engineered surface for deposition of high-Tc superconductors, nanoscale modulations of the surface of the underlying LaMnO3 (LMO) cap layer is a potential source for generating microstructural defects in YBa2Cu3O7- (YBCO) films. These defects may improve the flux-pinning and consequently increase the critical current density, Jc. To provide such nanoscale modulation via a practical and scalable process, tantalum (Ta) and palladium (Pd) nano-islands were deposited using dc-magnetron sputtering on the surface of the cap layer of commercial metal tape templates for second-generation wires. The size and density of these nano-islands can be controlled by changing sputtering conditions such as the power and deposition time. Compared to the reference sample grown on an untreated LMO cap layer, the YBCO films grown on the LMO cap layers with Ta or Pd nano-islands exhibited improved in-field Jc performance. Atomic Force Microscopy (AFM) and Transmission Electron Microscopy (TEM) were used to assess the evolving size and density of the nano-islands.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Dynamical reconstruction of the exciton in LiF with inelastic x-ray scattering

The absorption of light by materials proceeds through the formation of excitons, which are states in which an excited electron is bound to the valence hole it vacated. Understanding the structure and dynamics of excitons is important, for example, for developing technologies for light-emitting diodes or solar energy conversion. However, there has never been an experimental means to study the time-dependent structure of excitons directly. Here, we use causality-inverted inelastic x-ray scattering (IXS) to image the charge-transfer exciton in the prototype insulator LiF, with resolutions {Delta}t = 20.67 as (2.067 x 10{sup -17} s) in time and {Delta}x = 0.533 {angstrom} (5.33 x 10{sup -11} m) in space. Our results show that the exciton has a modulated internal structure and is coherently delocalized over two unit cells of the LiF crystal ({approx}8 {angstrom}). This structure changes only modestly during the course of its life, which establishes it unambiguously as a Frenkel exciton and thus amenable to a simplified theoretical description. Our results resolve an old controversy about excitons in the alkali halides and demonstrate the utility of IXS for imaging attosecond electron dynamics in condensed matter.

14 SOLAR ENERGY↗

Effect of Finite Pulse Length and Laser Frequency Chirp on HGHG and EEHG Seeding

Theoretical studies of high-gain harmonic generation (HGHG) and echo-enabled harmonic generation (EEHG) often start from a simplified model in which the beam is assumed infinitely long and longitudinally uniform and the laser induced energy modulation is perfectly sinusoidal and of infinite duration. In such a model the resulting seed has a spectrum consisting of a collection of delta-functions (of zero width) located at the harmonics of the laser frequency. Being a useful tool for study of the seed bunching amplitudes, such a model cannot be used for realistic analysis the spectral properties of the seed. In this paper we take into account the finite duration of the laser pulse as well as some possible laser phase errors to study their effect on the spectrum of the seed.

99 GENERAL AND MISCELLANEOUS↗

SU-F-T-238: Analyzing the Performance of MapCHECK2 and Delta4 Quality Assurance Phantoms in IMRT and VMAT Plans

Purpose: Intensity-modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT) have been widely investigated for use in radiotherapy and found to have a highly conformal dose distribution. Delta{sup 4} is a novel cylindrical phantom consisting of 1069 p-type diodes with true treatments measured in the 3D target volume. The goal of this study was to compare the performance of a Delta{sup 4} diode array for IMRT and VMAT planning with ion chamber and MapCHECK2. Methods: Fifty-four IMRT (n=9) and VMAT (n=45) plans were imported to Philips Pinnacle Planning System 9.2 for recalculation with a solid water phantom, MapCHECK2, and the Delta4 phantom. To evaluate the difference between the measured and calculated dose, we used MapCHECK2 and Delta{sup 4} for a dose-map comparison and an ion chamber (PTW 31010 Semiflex 0.125 cc) for a point-dose comparison. Results: All 54 plans met the criteria of <3% difference for the point dose (at least two points) by ion chamber. The mean difference was 0.784% with a standard deviation of 1.962%. With a criteria of 3 mm/3% in a gamma analysis, the average passing rates were 96.86%±2.19% and 98.42%±1.97% for MapCHECK2 and Delta{sup 4}, respectively. The student t-test of MapCHECK2/Delta{sup 4}, ion chamber/Delta{sup 4}, and ion chamber/MapCHECK2 were 0.0008, 0.2944, and 0.0002, respectively. There was no significant difference in passing rates between MapCHECK2 and Delta{sup 4} for the IMRT plan (p = 0.25). However, a higher pass rate was observed in Delta{sup 4} (98.36%) as compared to MapCHECK2 (96.64%, p < 0.0001) for the VMAT plan. Conclusion: The Pinnacle planning system can accurately calculate doses for VMAT and IMRT plans. The Delta{sup 4} shows a similar result when compared to ion chamber and MapCHECK2, and is an efficient tool for patient-specific quality assurance, especially for rotation therapy.

60 APPLIED LIFE SCIENCES↗

Observation of coherently enhanced tunable narrow-band terahertz transition radiation from a relativistic sub-picosecond electron bunch train

We experimentally demonstrate the production of narrow-band ({delta}f/f{approx_equal}20% at f{approx_equal}0.5THz) transition radiation with tunable frequency over [0.37, 0.86] THz. The radiation is produced as a train of sub-picosecond relativistic electron bunches transits at the vacuum-aluminum interface of an aluminum converter screen. The bunch train is generated via a transverse-to-longitudinal phase space exchange technique. We also show a possible application of modulated beams to extend the dynamical range of a popular bunch length diagnostic technique based on the spectral analysis of coherent radiation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗