Search NASA⌕ Search

SEARCH · Search NASA

Results for “DEMAGNETIZATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Design and On-Orbit Operation of the Adiabatic Demagnetization Refrigerator on the Hitomi Soft X-Ray Spectrometer Instrument

The Soft X-ray Spectrometer instrument on the Astro-H observatory contains a 6x6 array of x-ray microcalorimeters that is cooled to 50 mK by an adiabatic demagnetization refrigerator (ADR). The ADR consists of three stages in order to provide stable detector cooling using either a 1.2 K superfluid helium bath or a 4.5 K Joule-Thomson (JT) cryocooler as its heat sink. When liquid helium is present, two of the ADR's stages are used to single-shot cool the detectors while rejecting heat to the helium. After the helium is depleted, all three stages are used to continuously cool the helium tank (to about 1.5 K) and single-shot cool the detectors (to 50 mK), using the JT cryocooler as its heat sink. The Astro-H observatory, renamed Hitomi after its successful launch in February 2016, carried approximately 36 liters of helium into orbit. On day 5, the helium had cooled sufficiently (<1.4 K) to allow operation of the ADR. This paper describes the design, operation and on-orbit performance of the ADR, and the use of the ADR's heat rejection as a tool for mass gauging the helium tank.

adiabatic demagnetization refrigerator↗

Development of a Flight-Worthy 10 to 4 K Continuous Adiabatic Demagnetization Refrigerator

The cryogenics and fluids branch at NASA's Goddard Space Flight Center is currently developing a high-efficiency, vibration-free, flight-worthy Continuous Adiabatic Demagnetization Refrigerator (CADR) that consist of two modular units: one that lifts ~6 microW at 50 mK while rejecting its heat to a 4 K thermal sink, and another unit that provides a constant 4 K cooling stage while rejecting its heat to a thermal sink at 10 K. The two units are linked together via a 4 K common platform. This paper discusses the status report on the thermodynamic performance of the 4 -10 K ADR. This ADR utilizes an Nb3Sn superconducting magnet and Gadolinium Gallium Garnet (GGG) as its refrigerant. Results show that an idealized cycle, one where its hold time at 4 K is equal to the recycle time, can lift 13 mW at 4 K with a hold time of 132 seconds.

CADR↗

Effective Demagnetizing Factors of Diamagnetic Samples of Various Shapes

Effective demagnetizing factors that connect the sample magnetic moment with the applied magnetic field are calculated numerically for perfectly diamagnetic samples of various nonellipsoidal shapes. The procedure is based on calculating the total magnetic moment by integrating the magnetic induction obtained from a full three-dimensional (3D) solution of the Maxwell equations using an adaptive mesh. The results are relevant for superconductors (and conductors in ac fields) when the London penetration depth (or the skin depth) is much smaller than the sample size. In conclusion, simple but reasonably accurate approximate formulas are given for practical shapes including rectangular cuboids, finite cylinders in axial and transverse fields, as well as infinite rectangular and elliptical cross-section strips.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Formation of Complex Spin Textures in Thermally Demagnetized La 0.7 Sr 0.3 Mn O 3 Artificial-Spin-Ice Structures

Artificial spin ices (ASIs) have traditionally been designed such that each nanomagnet possesses a single-domain magnetic configuration that is assumed to be minimally perturbed by interisland dipolar interactions. Using x-ray photoemission electron microscopy to perform magnetic domain imaging, we study thermally demagnetized La 0.7 Sr 0.3 MnO 3 -based brickwork ASI arrays and showed that complex spin textures (CSTs) can be stabilized through an appropriate selection of nanoisland width and interisland spacing. While the width dependence can be explained through the dominance of shape anisotropy in isolated nanoislands, the ASIs we investigate demonstrate a complex dependence on both the nanoisland width and interisland spacing. Micromagnetic simulations reveal that interisland dipolar interactions play a role in the formation of CSTs, which are composed of single- and double-vortex states. Furthermore, energy analysis of the simulations provides an understanding of the system energetics that arises from a delicate balance between intraisland effects (i.e., shape anisotropy and exchange energy) and interisland effects (i.e., dipolar interactions between nearest-neighbor nanoislands).

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Lattice Vibrations Boost Demagnetization Entropy in Shape Memory Alloy

Magnetocaloric (MC) materials present an avenue for chemical-free, solid state refrigeration through cooling via adiabatic demagnetization. We have used inelastic neutron scattering to measure the lattice dynamics in the MC material Ni 45 Co 5 Mn 36.6 In 13.4 . Upon heating across TC, the material exhibits an anomalous increase in phonon entropy of 0.17 0.04 k_B/atom, which is nine times larger than expected from conventional thermal expansion. We find that the phonon softening is focused in a transverse optic phonon, and we present the results of first-principle calculations which predict a strong coupling between lattice distortions and magnetic excitations.

36 MATERIALS SCIENCE↗

An adiabatic demagnetization refrigerator for infrared bolometers

Adiabatic demagnetization refrigerators have been built and installed in small portable liquid helium cryostats to test the feasibility of this method of cooling infrared bolometric detectors to temperatures below 0.3 K. Performance has been achieved which suggests that bolometer temperatures of 0.2 K can be maintained for periods of approximately 60 hours. Applications to sensitive infrared detection from ground-based telescopes and space satellites are discussed. Design data are given which permit the evaluation of refrigerator performance for a variety of design parameters.

Britt, R. D.↗

Design of an adiabatic demagnetization refrigerator for studies in astrophysics

An adiabatic demagnetization refrigerator was designed for cooling infrared bolometers for studies in astrophysics and aeronomy. The design was tailored to the requirements of a Shuttle sortie experiment. The refrigerator should be capable of maintaining three bolometers at 0.1 K with a 90% cycle. The advantage are of operations the bolometer at 0.1K. greater sensitivity, faster response time, and the ability to use larger bolometer elements without compromising the response time. The design presented is the first complete design of an ADR intended for use in space. The most important of these specifications are to survive a Shuttle launch, to operate with 1.5 K - 2.0 K space-pumped liquid helium as a heat sink, to have a 90% duty cycle, and to be highly efficient.

Castles, S.↗

Bolometers operated at 0.1 K and 0.2 K cooled by adiabatic demagnetization

The construction of bolometers operating at temperatures of 0.1 K and 0.2 K and cooled by adiabatic demagnetization is reported. The electrical noise-equivalent power (NEP) of the bolometers was found to be 1.8 and 6.6 x 10 to the -16th W/sq rt Hz, respectively. These values are within a factor of two of the expected performance based upon bolometer theory. The thermistor material used was gallium-doped single-crystal germanium, for which a resistivity temperature dependence is found.

Lesyna, L.↗

A progress report on bolometers operating at 0.1 K using adiabatic demagnetization refrigeration

Bolometers are still the detectors of choice for low background infrared observations at wavelengths longer than 200 microns. In the low background limit, bolometers become more sensitive as their operating temperature decreases, due to fundamental thermodynamic laws. The adiabatic demagnetization technique was evaluated by building a bolometer detection system operating at a wavelength of 1 millimeter for use at a ground based telescope. The system was fit checked at the telescope and is expected to take its first data in November, 1985.

Roellig, T.↗

An adiabatic demagnetization cooled bolometer system

An adiabatic demagnetization refrigeration (ADR) system suitable for cooling bolometers for use at infrared and submillimeter wavelengths is constructed. Because it does not rely on a gravitational field for operation, this refrigeration method has been proposed to cool bolometers intended for NASA's Space Infrared Telescope Facility. To explore the use of ADR in this manner, a portable instrument that has been used successfully for ground-based astronomical observations was constructed. By employing chromic potassium sulfate as a paramagnetic cooling material, bolometers were cooled to temperatures of 0.1 K with a cryogenic hold time of greater than nine hours.

Lesyna, L.↗

An adiabatic demagnetization refrigerator for SIRTF

An adiabatic demagnetization refrigerator (ADR) has been proposed to cool bolometric infrared detectors on the multiband imaging photometer of the Space Infrared Telescope Facility (SIRTF). One such refrigerator has been built which uses a ferric ammonium alum salt pill suspended by nylon threads in a 3-T solenoid. The resonant modes of this suspension are above 100 Hz. The heat leak to the salt pill is less than 0.5 microW. The system has a hold time at 0.1K of more than 12 h. The cold stage temperature is regulated with a feedback loop that controls the magnetic field. A second, similar refrigerator is being built at a SIRTF prototype to fly on a ballon-borne telescope. It will use a ferromagnetic shield. The possibility of using a high-Tc solenoid-actuated heat switch is also discussed.

Timbie, P. T.↗

Adiabatic demagnetization refrigerator for space use

An Adiabatic Demagnetization Refrigerator (ADR) for space use is under development at NASA's Goddard Space Flight Center (GSFC). The breadboard ADR operated at 100 mK for 400 minutes. Some significant changes to that ADR, designed to eliminate shortcomings revealed during tests, are reported. To increase thermal contact, the ferric ammonium sulfate crystals were grown directly on gold-plated copper wires which serve as the thermal bus. The thermal link to the X-ray sensors was also markedly improved. To speed up the testing required to determine the best design parameters for the gas gap heat switch, the new heat switch has a modular design and is easy to disassemble.

Serlemitsos, A. T.↗

Salt materials testing for a spacecraft adiabatic demagnetization refrigerator

As part of a technology development effort to qualify adiabatic demagnetization refrigerators for use in a NASA spacecraft, such as the Space Infrared Telescope Facility, a study of low temperature characteristics, heat capacity and resistance to dehydration was conducted for different salt materials. This report includes results of testing with cerrous metaphosphate, several synthetic rubies, and chromic potassium alum (CPA). Preliminary results show that CPA may be suitable for long-term spacecraft use, provided that the salt is property encapsulated. Methods of salt pill construction and testing for all materials are discussed, as well as reliability tests. Also, the temperature regulation scheme and the test cryostat design are briefly discussed.

Savage, M. L.↗

Design of a spaceworthy adiabatic demagnetization refrigerator

A spaceworthy adiabatic demagnetization refrigerator (ADR) under development at NASA-Goddard is presented. A baseline model heat switch was tested extensively with an on/off ratio of about 10,000 and a parasitic heat leak of 10 micro-W. Data obtained from the breadboard models were used to design an ADR with improved structural integrity. The core of the ADR is the salt pill which consists of the paramagnetic salt crystal and the thermal bus. When a magnetic field is applied to the salt it forces the alignment of the magnetic moments, thereby decreasing the entropy of the salt. Preliminary tests results showed a net crystal mass of 680 g instead of the expected 740 g, which indicate that there are gaps in the salt pill. A partial fix was accomplished by sealing helium gas in the salt pill at a pressure of 2 bar, which improved the thermal contact during salt magnetization, at about 2 K.

Serlemitsos, A. T.↗

Magnetic shielding for a spaceborne adiabatic demagnetization refrigerator (ADR)

The Goddard Space Flight Center has studied magnetic shielding for an adiabatic demagnetization refrigerator. Four types of shielding were studied: active coils, passive ferromagnetic shells, passive superconducting coils, and passive superconducting shells. The passive superconducting shells failed by allowing flux penetration. The other three methods were successful, singly or together. Experimental studies of passive ferromagnetic shielding are compared with calculations made using the Poisson Group of programs, distributed by the Los Alamos Accelerator Code Group of the Los Alamos National Laboratory. Agreement between calculation and experiment is good. The ferromagnetic material is a silicon iron alloy.

Warner, Brent A.↗

A Multi-Stage Continuous-Duty Adiabatic Demagnetization Refrigerator

The design for a multi-stage adiabatic demagnetization refrigerator (ADR) that can provide continuous cooling at very low temperatures is presented. The ADR is being developed for use in x-ray, IR and sub-millimeter space astronomy missions which will employ large format detector arrays operating at 50 mK and lower and which may dissipate up to 10 microwatts. It is also being designed to reject heat slowly to a relatively warm heat sink (in the 6-10 K range), so that future missions may use mechanical cryocoolers instead of liquid helium for pre-cooling. The continuous nature of the device gives it a much higher cooling power per unit mass, allowing it to be much smaller and lighter than existing ADRs with comparable performance. Design details are discussed along with prototype test results.

Shirron, P. J.↗

A Continuous Adiabatic Demagnetization Refrigerator for Use with Mechanical Coolers

We have begun developing an adiabatic demagnetization refrigerator (ADR) which can produce continuous cooling at temperatures of 50 mK or lower, with high cooling power (goal of 10 PW). The design uses multiple stages to cascade heat from a continuously-cooled stage up to a heat sink. The serial arrangement makes it possible to add stages to extend the operating range to lower temperature, or to raise the heat rejection temperature. Compared to conventional single-shot ADRS, this system achieves higher cooling power per unit mass and is able to reject its heat at a more uniform rate. For operation with a mechanical cryocooler, this latter feature stabilizes the heat sink temperature and allows both the ADR and cryocooler to operate more efficiently. The ADR is being designed to operate with a heat sink as warm as 10-12 K to make it compatible with a wide variety of mechanical coolers as part of a versatile, cryogen-free low temperature cooling system. A two-stage system has been constructed and a proof-of-principle demonstration was conducted at 100 mK. Details of the design and test results, as well as the direction of future work, are discussed.

Shirron, P.↗