Syphon Diaphragms : A Method for Predicting Their Performance for Purposes of Instrument Design

Here, the purpose is to show that the characteristic performance of a syphon diaphragm can be predicted from a knowledge of its stiffness and of its dimensions. The proof is based on a mathematical analysis of this type of diaphragm, together with enough experimental data to prove the validity of the assumptions and the sufficiency of the analysis. Equations are developed for the performance of syphons under various conditions of loading, both for concentrated loads and for hydrostatic pressure.

Eaton, H N↗

Effect of Aging on Taut Rubber Diaphragms

As part of an investigation of special compositions of rubber suitable for use as diaphragms for aircraft instruments, six samples were used as taut diaphragms in instruments and allowed to age for five years. Two of the instruments were in operating condition after this period of time and one had remarkably little change in performance. In making the rubber tetraethyl thorium disulfide was employed as a vulcanizing agent.

Henrickson, H B↗

Diaphragms for Aeronautic Instruments

This investigation was carried out at the request of the National Advisory Committee for Aeronautics and comprises an outline of historical developments and theoretical principles, together with a discussion of expedients for making the most effective use of existing diaphragms actuated by the hydrostatic pressure form an essential element of a great variety instruments for aeronautic and other technical purposes. The various physical data needed as a foundation for rational methods of diaphragm design have not, however, been available hitherto except in the most fragmentary form.

Hersey, M D↗

Investigation of the diaphragm-type pressure cell

This report relates to various improvements in the process of manufacture of the NACA standard pressure cell. Like most pressure recording devices employing thin diaphragms, they would in general show considerable change in calibration with temperature and also some change of calibration with time or aging effect. The required diaphragm thickness and the desirable rate of mechanical magnification have been determined on the basis of several hundred tests.

Theodorsen, Theodore↗

Materials for Slack Diaphragms

This report deals with systematic experiments carried out on five diaphragm materials with different pretreatment, for the purpose of ascertaining the suitability of such materials for slack diaphragms. The relationship of deflection and load, temperature and moisture, was recorded. Of the explored materials, synthetic leather, balloon cloth, goldbeaters skin, Igelit and Buna, synthetic leather treated with castor oil is the most suitable material for the small pressure range required. Balloon cloth is nearly as good, while goldbeaters skin, Igelit and Buna were found to be below the required standards.

Puschmann, Traute↗

Optical Detection Of Fractures In Ceramic Diaphragms

Simple optical technique enables quick, nondestructive inspection of surfaces of ceramic diaphragms and disks for fractures and discontinuities. Involves reflecting beam of light from laser at glancing angle of about 20 degrees to 25 degrees off surface inspected and examining pattern of reflected light on suitable viewing surface as beam swept across surface. When fracture present, reflection pattern separates into two or more speckled spots. Technique applied in inspection of ceramic diaphragms bearing electronic circuits. Also useful in detection of fatigue cracks on aircraft.

Laue, Eric G.↗

Effect of spaceflight on oxidative and antioxidant enzyme activity in rat diaphragm and intercostal muscles

There are limited data regarding changes in oxidative and antioxidant enzymes induced by simulated or actual weightlessness, and any additional information would provide insight into potential mechanisms involving other changes observed in muscles from animals previously flown in space. Thus, the NASA Biospecimen Sharing Program was an opportunity to collect valuable information. Oxidative and antioxidant enzyme levels, as well as lipid peroxidation, were measured in respiratory muscles from rates flown on board Space Shuttle mission STS-54. The results indicated that there was an increasing trend in citrate synthase activity in the flight diaphragm when compared to ground based controls, and there were no significant changes observed in the intercostal muscles for any of the parameters. However, the lipid peroxidation was significantly (p less than 0.05) decreased in the flight diaphragm. These results indicate that 6 day exposure to microgravity may have a different effect on oxidative and antioxidant activity in rat respiratory muscles when compared to data from previous 14 day hindlimb suspension studies.

Lee, Mona D.↗

Experimental Characterization of Piezoelectric Radial Field Diaphragms for Fluidic Control

NASA has recently developed a new piezoelectric actuator, the Radial Field Diaphragm or RFD. This actuator uses a radially-directed electric field to generate concentric out-of-plane (Z-axis) motion that allows this packaged device to be used as a pump or valve diaphragm. In order to efficiently use this new active device, experimental determination of pressure, flow rate, mechanical work, power consumption and overall efficiency needs to be determined by actually building a pump. However, without an optimized pump design, it is difficult to assess the quality of the data, as these results are inherent to the actual pump. Hence, separate experiments must be conducted in order to generate independent results to help guide the design criteria and pump quality. This paper focuses on the experiments used to generate the RFD's operational parameters and then compares these results to the experimentally determined results of several types of ball pumps. Also discussed are how errors are inherently introduced into the experiments, the pump design, experimental hardware and their effects on the overall system efficiency.

Bryant, R. G.↗

Role of the medial medullary reticular formation in relaying vestibular signals to the diaphragm and abdominal muscles

Changes in posture can affect the resting length of respiratory muscles, requiring alterations in the activity of these muscles if ventilation is to be unaffected. Recent studies have shown that the vestibular system contributes to altering respiratory muscle activity during movement and changes in posture. Furthermore, anatomical studies have demonstrated that many bulbospinal neurons in the medial medullary reticular formation (MRF) provide inputs to phrenic and abdominal motoneurons; because this region of the reticular formation receives substantial vestibular and other movement-related input, it seems likely that medial medullary reticulospinal neurons could adjust the activity of respiratory motoneurons during postural alterations. The objective of the present study was to determine whether functional lesions of the MRF affect inspiratory and expiratory muscle responses to activation of the vestibular system. Lidocaine or muscimol injections into the MRF produced a large increase in diaphragm and abdominal muscle responses to vestibular stimulation. These vestibulo-respiratory responses were eliminated following subsequent chemical blockade of descending pathways in the lateral medulla. However, inactivation of pathways coursing through the lateral medulla eliminated excitatory, but not inhibitory, components of vestibulo-respiratory responses. The simplest explanation for these data is that MRF neurons that receive input from the vestibular nuclei make inhibitory connections with diaphragm and abdominal motoneurons, whereas a pathway that courses laterally in the caudal medulla provides excitatory vestibular inputs to these motoneurons.

Non-NASA Center↗

Changes in diaphragm muscle collagen gene expression after acute unilateral denervation

The purpose of the present study was to examine the effects of acute (3 days) unilateral diaphragm denervation (DNV) on 1) levels of alpha 1(I) and alpha 1(III) procollagen mRNA; 2) collagen concentration [hydroxyproline (HYP)]; 3) amount of the nonreducible collagen cross-link hydroxylysylpyridinoline (HP); and 4) the passive force-length relationship of the muscle. The levels of alpha 1(I) and alpha 1(III) procollagen mRNA, HYP concentration, and amount of HP were measured in muscle segments from the midcostal region of DNV and intact (INT) hemidiaphragms of adult male Fischer 344 rats (250-300 g). The in vitro passive force-length relationship of DNV and INT hemidiaphragm was determined by lengthening and shortening the diaphragm muscle segments from 85 to 115% of optimal length at a constant velocity (0.6 optimal length/s). Three days after DNV, the level of alpha 1(I) procollagen mRNA was increased over 15-fold in the DNV hemidiaphragm compared with INT (P < 0.05), whereas the level of alpha 1(III) procollagen mRNA was increased by approximately sixfold in the DNV hemidiaphragm compared with INT (P < 0.05). Collagen (HYP) concentration did not differ between groups, averaging 8.7 and 8.9 micrograms/mg dry wt for the DNV and INT hemidiaphragms, respectively. In addition, there was no difference in the amount of the mature nonreducible collagen cross-link HP between the DNV and INT hemidiaphragms (0.66 vs. 0.76 mole HP/mole collagen, respectively). The amount of passive force developed during lengthening did not differ between DNV and INT hemidiaphragms. These data indicate that acute DNV of the hemidiaphragm is associated with an increase in the mRNA level of the two principal fibrillar collagen phenotypes in skeletal muscle. However, despite extensive muscle remodeling, the passive force-length relationship of the DNV hemidiaphragm is unaffected compared with the INT muscle.

Non-NASA Center↗

Embossed Teflon AF Laminate Membrane Microfluidic Diaphragm Valves

A microfluidic system has been designed to survive spaceflight and to function autonomously on the Martian surface. It manipulates microscopic quantities of liquid water and performs chemical analyses on these samples to assay for the presence of molecules associated with past or present living processes. This technology lies at the core of the Urey Instrument, which is scheduled for inclusion on the Pasteur Payload of the ESA ExoMars rover mission in 2013. Fabrication processes have been developed to make the microfabricated Teflon-AF microfluidic diaphragm pumps capable of surviving extreme temperature excursions before and after exposure to liquid water. Two glass wafers are etched with features and a continuous Teflon membrane is sandwiched between them (see figure). Single valves are constructed using this geometry. The microfabricated devices are then post processed by heating the assembled device while applying pneumatic pressure to force the Teflon diaphragm against the valve seat while it is softened. After cooling the device, the embossed membrane retains this new shape. This solves previous problems with bubble introduction into the fluid flow where deformations of the membrane at the valve seat occurred during device bonding at elevated temperatures (100-150 C). The use of laminated membranes containing commercial Teflon AF 2400 sheet sandwiched between spun Teflon AF 1600 layers performed best, and were less gas permeable than Teflon AF 1600 membranes on their own. Spinning Teflon AF 1600 solution (6 percent in FLOURINERT(Registered TradeMark) FC40 solvent, 3M Company) at 500 rpm for 1.5 seconds, followed by 1,000 rpm for 3 seconds onto Borofloat glass wafers, results in a 10-micron-thick film of extremely smooth Teflon AF. This spinning process is repeated several times on flat, blank, glass wafers in order to gradually build a thick, smooth membrane. After running this process at least five times, the wafer and Teflon coating are heated under vacuum at 220 C for one hour in order to drive off any residual solvent present in the composite film. After this, a second blank, glass wafer is brought down from above and the stack is held under vacuum at 3 atm mechanical pressure for ten 10 hours.

Willis, Peter↗