Search NASA⌕ Search

SEARCH · Search NASA

Results for “DISPLACEMENT GAGES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Experimental Results From Stitched Composite Multi-Bay Fuselage Panels Tested Under Uni-Axial Compression

The experimental results from two stitched VARTM composite panels tested under uni-axial compression loading are presented. The curved panels are divided by frames and stringers into five or six bays with a column of three bays along the compressive loading direction. The frames are supported at the ends to resist out-of-plane translation. Back-to-back strain gages are used to record the strain and displacement transducers were used to record the out-of-plane displacements. In addition a full-field measurement technique that utilizes a camera-based-stero-vision system was used to record displacements. The panels were loaded in increments to determine the first bay to buckle. Loading was discontinued at limit load and the panels were removed from the test machine for impact testing. After impacting at 20 ft-lbs to 25 ft-lbs of energy with a spherical indenter, the panels were loaded in compression until failure. Impact testing reduced the axial stiffness 4 percent and less than 1 percent. Postbuckled axial panel stiffness was 52 percent and 70 percent of the pre-buckled stiffness.

Baker, Donald J.↗

Evaluation of a Compression-Loaded-Stitched-Multi-Bay Fuselage Panel With Barely Visible Impact Damage

The experimental results from a stitched VaRTM carbon-epoxy composite panel tested under uni-axial compression loading are presented along with nonlinear finite element analysis prediction of the response. The curved panel is divided by frames and stringers into six bays with a column of three bays along the compressive loading direction. The frames are supported at the frame ends to resist out-of-plane translation. Back-to-back strain gages are used to record the strain and displacement transducers were used to record the out-of-plane displacements. In addition a full-field-displacement measurement technique that utilizes a camera-based-stereo-vision system was used to record the displacements. The panel was loaded to 1.5 times the predicted initial buckling load (1st bay buckling load, P(sub er) from the nonlinear finite element analysis and then was removed from the test machine for impact testing. After impacting with 20 ft-lbs of energy using a spherical impactor to produce barely visible damage the panel was loaded in compression until failure. The buckling load of the first bay to buckle was 97% of the buckling load before impact. The stitching constrained the impact damage from growing during the loading to failure. Impact damage had very little overall effect on panel stiffness. Panel stiffness measured by the full-field-displacement technique indicated a 13% loss in stiffness after impact. The panel failed at 1.64 times the first panel buckling load. The barely visible impact damage did not grow noticeably as the panel failed by global instability due to stringer-web terminations at the frame locations. The predictions from the nonlinear analysis of the finite element modeling of the entire specimen were very effective in the capture of the initial buckling and global behavior of the panel. In addition, the prediction highlighted the weakness of the panel under compression due to stringer web terminations. Both the test results and the nonlinear predictions serve to reinforce the severe penalty in structural integrity caused by the low cost manufacturing technique to terminate the stringer webs, and demonstrates the importance of this type of sub-component testing and high fidelity failure analysis in the design of a composite fuselage.

Baker, Donald J.↗

Flowmeter measures low gas-flow rates

Positive-displacement flowmeter measures low gas-flow rates by gaging the time required for a slug of mercury to pass between two reference levels in a tube of known volume.

Wells, F. E.↗

Elevated-Temperature Tensile-Testing of Foil-Gage Metals

Automated system for measuring strain in metal foils at temperatures above 500 degrees F (260 degrees C) uses mechanical extensometer and displacement transducer. System includes counterbalance feature, which eliminates weight contribution of extensometer and reduces grip pressure required for attachment to specimen. Counterbalancing feature overcomes two major difficulties in using extensometers with foil-gage specimens: (1) Weight of extensometer and transducer represents significant fraction of total load applied to specimen and may actually damage it; and (2) grip pressure required for attachment of extensometer to specimens may induce bending stresses in foil-gage materials.

Blackburn, L. B.↗

The Design of Cruciform Test Specimens for Planar Biaxial Testing of Fabrics for Inflatable Aerodynamic Decelerators

A preliminary analytical study was conducted to investigate the effects of cruciform test specimen geometries on strain distribution uniformity in the central gage section under biaxial loads. Three distinct specimen geometries were considered while varying the applied displacements in the two orthogonal directions. Two sets of woven fabric material properties found in literature were used to quantify the influence of specimen geometries on the resulting strain distributions. The uniformity of the strain distribution is quantified by taking the ratio between the two orthogonal strain components and characterizing its gradient across the central area of the gage section. The analysis results show that increasing the specimen s length relative to its width promotes a more uniform strain distribution in the central section of the cruciform test specimen under equibiaxial enforced tensile displacements. However, for the two sets of material properties used in this study, this trend did not necessary hold, when the enforced tensile displacements in the two orthogonal directions were not equal. Therefore, based on the current study, a tail length that is 1.5 times that of the tail width is recommended to be the baseline/initial specimen design.

Corbin, Cole K.↗

Cratering motions and structural deformation in the rim of the Prairie Flat multiring explosion crater

Cratering motions and structural deformation are described for the rim of the Prairie Flat multiring crater, 85.5 m across and 5.3 m deep, which was formed by the detonation of a 500-ton TNT surface-tangent sphere. The terminal displacement and motion data are derived from marker cans and velocity gages emplaced in drill holes in a three-dimensional matrix radial to the crater. The integration of this data with a detailed geologic cross section, mapped from deep trench excavations through the rim, provides a composite view of the general sequence of motions that formed a transiently uplifted rim, overturned flap, inverted stratigraphy, downfolded rim, and deformed strata in the crater walls. Preliminary comparisons with laboratory experimental cratering and with numerical simulations indicate that explosion craters of the Prairie Flat-type generated by surface and near-surface energy sources tend to follow predictable motion sequences and produce comparable structural deformation. More specifically, central uplift and multiring impact craters with morphologies and structures comparable to Prairie Flat are inferred to have experienced similar deformational histories of the rim, such as uplift, overturning, terracing, and downfolding.

Roddy, D. J.↗

Improved experimental and diagnostic techniques for dynamic tensile stress–strain measurement with a Kolsky tension bar

Kolsky tension bar experiments were improved for dynamic tensile stress–strain measurements with higher fidelity and minimal uncertainties. The difficulties associated with specimen gripping, relatively short gage section, and geometric discontinuity at the bar ends all compromise the accuracy of the traditional strain measurement method in a Kolsky tension bar experiment. Here in this study, an improved three-channel splitting-beam laser extensometer technique was developed to directly and independently track the displacement of the incident and transmission bar interfaces. By adopting a dual-channel configuration on the incident bar side, the resolution and measurement range of this laser extensometer were coordinated between the two channels to provide highly precise measurement at both small and large strains under high strain-rate loading condition. On the transmission bar side an amplified channel, similar to that used on the incident bar side, was adopted to measure the transmission bar displacement with high resolution. With this novel design, a maximum resolution of approximately 500 nm can be obtained for the bar displacement measurement, which corresponds to a strain of 0.0079% for a specimen with 6.35 mm gage length. To further improve the accuracy, a pair of lock nuts were used to tighten the tensile specimen to the bars in an effort not only to prevent the specimen from potential pre-torsional deformation and damage during installation, but also to provide better thread engagement between the specimen and the bar ends. As a demonstration of this technique, dynamic tensile stress–strain response of a 304L stainless steel was characterized with high resolution in both elastic and plastic deformations.

42 ENGINEERING↗

Evaluation of mounting bolt loads for Space Shuttle Get Away Special (GAS) adapter beam

During the prototype vibration tests of the GAS adapter beam, significant impacting of the beam at its support points was observed. The cause of the impacting was traced to gaps under the mounting bolt heads. Because of the nonlinear nature of the response, it was difficult to evaluate the effects which Shuttle launch dynamics might have on the mounting bolt loads. A series of tests were conducted on an electrodynamic exciter in which the transient acceleration time histories, which had been measured during the Space Transportation System-1 (STS-1; Space Shuttle mission 1) launch, were simulated. The actual flight data had to be filtered and compensated so that it could be reproduced on the shaker without exceeding displacement and velocity limitations. Mounting bolt loads were measured directly by strain gages applied to the bolts. Various gap thicknesses and bolt torques were investigated. Although increased gap thickness resulted in greater accelerations due to impacting, the bolt loads were not significantly affected. This is attributed to the fact that impacting excited mostly higher frequency modes which do not have significant modal mass.

Talapatra, D. C.↗

COD measurements at various positions along a crack

Load versus crack-opening-displacement (COD) was measured at various positions along the border of a fatigue crack as it grew from a small surface crack on the edge of an aluminum specimen into a through-the-thickness crack. Displacements were measured with a laser-based interferometric system with a gage length of 70 microns and a resolution of 0.01 micron. These load-COD curves can be used to determine opening loads and thereby investigate the effect of closure on the growth of small cracks. In general, the opening loads decrease as the crack grows.

Sharpe, W. N., Jr.↗

Strain measurement technique for elevated temperature tensile and creep testing of foil-gage metals

This paper describes a strain measurement technique suitable for elevated-temperature tensile and creep testing of foil-gage metals, using a modified commonly available mechanical extensometer in conjunction with a displacement transducer. The extensometer was modified by attaching to it a counterbalance (to reduce the effect of the extensometer weight on the total maximum test load) and by incorporating a conical tip/flat-edge design (to minimize induced stresses in the specimen resulting from extensometer attachment). Creep tests were performed on 0.102-mm-thick specimens of Ti-6Al-4V at temperatures of 427 and 538 C, at nominal applied stresses of 310.3 and 172.4 MPa, respectively. Examination of the resulting creep curves suggested that the strain measurement system provided actual creep strain values with good accuracy.

Blackburn, L. B.↗

Measurements of fuselage skin strains and displacements near a longitudinal lap joint in a pressurized aircraft

Strains and displacements in a small area near a longitudinal lap joint in the fuselage skin of a B737 aircraft were measured during a pressurization cycle to a differential pressure of 6.2 psi while the aircraft was on the ground. It was found that hoop strains were higher than longitudinal strains at each location; membrane strains in the unreinforced skin were higher than in the joint; membrane strains in the hoop direction, as well as radial displacements, tended to be highest at the mid-bay location between skin reinforcements; significant bending in the hoop direction occurred in the joint and in the skin near the joint, and the bending was unsymmetrically distributed about the stringer at the middle of the joint; and radial displacements were unsymmetrically distributed across the lap joint. The interpretation of the strain gage data for locations on the bonded and riveted lap joint assumed that the joint did not contain disbonded areas.

Phillips, Edward P.↗

Impact of β n and spectrum of n = 1 applied fields on fast ion losses in DIII-D

Abstract The effect of n = 1 magnetic perturbations (MPs) on prompt fast ion losses in DIII-D has been investigated using the light ion beam probe technique. The effect of normalized beta, β n , and the plasma response to the MPs is studied for several MP spectra. Magnetics data show a strong dependence of plasma response to β n that depends on the phase difference in perturbation coils, Δ ϕ U L . For most phases, the response increases with β n , however, the response is suppressed for phases between 180 ∘ and 240 ∘ . Experimental data from scintillator based fast ion loss detectors shows that relative fluctuation of lost ions (20%–30% of the steady signal) does not diminish across the L- to H-mode transition for Δ ϕ U L = 240 ∘ , despite the 34% decrease in radial response field and 50% decrease in poloidal response field. Simulations of the DIII-D discharges using M3D-C1 and ASCOT5 find that prompt losses from neutral beam injection in each investigated case hit the first wall at several concentrated locations: the vessel floor, midplane diagnostic ports, vessel ceiling, and inner wall. Simulated losses from co-injection neutral beams are born outside the last closed flux surface, corresponding to radial orbit displacements of 3–6 cm due to the MPs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Short fatigue cracks in notched aluminum specimens

The short-crack fatigue behavior in notched specimens of Al 2024-T3 was studied at values of the stress ratio, R, equal to 0.5, 0.0, -1.0, and -2.0. Crack growth was monitored using a replica technique for cracks ranging in length from a few tens of a micron to the specimen's thickness (2.3 mm). Crack opening displacement was measured for surface cracks as short as 0.035 mm using the interferometric strain/displacement gage, a laser-based optical technique described by Sharpe (1982). It was found that the growth rates of short cracks were faster than the rates of long cracks for R values of -1.0 and -2.0. No significant difference was observed for R = 0.0, and at R = 0.5, the short cracks actually grew more slowly that the long ones. At all R values, the closure stresses measured for short cracks were smaller than those predicted for large cracks.

Lee, J. J.↗

Longitudinally Jointed Edge-Wise Compression HoneyComb Composite Sandwich Coupon Testing And Fe Analysis: Three Methods of Strain Measurement, And Comparison

Three distinct strain measurement methods (i.e., foil resistance strain gages, fiber optic strain sensors, and a three-dimensional digital image photogrammetry that gives full field strain and displacement measurements) were implemented to measure strains on the back and front surfaces of a longitudinally jointed curved test article subjected to edge-wise compression testing, at NASA Goddard Space Flight Center, according to ASTM C364. The pre-test finite element analysis (FEA) was conducted to assess ultimate failure load and predict strain distribution pattern throughout the test coupon. The predicted strain pattern contours were then utilized as guidelines for installing the strain measurement instrumentations. The foil resistance strain gages and fiber optic strain sensors were bonded on the specimen at locations with nearly the same analytically predicted strain values, and as close as possible to each other, so that, comparisons between the measured strains by strain gages and fiber optic sensors, as well as the three-dimensional digital image photogrammetric system are relevant. The test article was loaded to failure (at ~167 kN), at the compressive strain value of ~10,000 micro epsilon. As a part of this study, the validity of the measured strains by fiber optic sensors is examined against the foil resistance strain gages and the three-dimensional digital image photogrammetric data, and comprehensive comparisons are made with FEA predictions.

Farrokh, Babak↗

Lumped parameter analysis of a stringer reinforced plate excited by band limited noise

The maximum root-mean-square response of a square clamped plate, subjected to a stationary random excitation, was determined both theoretically and empirically. For the tests, a 40 x 40 x 1/4 aluminum sheet was milled out to provide a thin waffle plate with 9 panels. The plate was acoustically excited, with the frequency range limited between 25 Hz and 500 Hz. The root-mean-square power of the random excitations, 149 decibels, was nearly constant for all natural frequencies of the plate system. Strain gage readings at 14 points were plotted as power spectral densities and root-mean-square displacements. A modal damping ratio matrix was determined from the response curves. Damping ratios were found to be a function of frequency, but not of location on the plate. For comparisons with the theoretical response, the plate was subdivided into 14 modes and anlayzed as a damped, lumped parameter system by use of an approximate normal-mode method. This method gave the best predictions of the power spectral densities for the lower frequencies. That prediction errors increased for the higher frequencies is attributed to improper assumptions for mass distribution and the insufficient number of lumped mass points.

Bilyeu, D. J.↗

Test and Analysis of Sub-Components of Aluminum-Lithium Alloy Cylinders

Integrally machined blade-stiffened panels subjected to an axial compressive load were tested and analyzed to observe the buckling, crippling, and postcrippling response of the panels. The panels were fabricated from aluminum-lithium alloys 2195 and 2050, and both alloys have reduced material properties in the short transverse material direction. The tests were designed to capture a failure mode characterized by the stiffener separating from the panel in the postbuckling range. This failure mode is attributed to the reduced properties in the short transverse direction. Full-field measurements of displacements and strains using three-dimensional digital image correlation systems and local measurements using strain gages were used to capture the deformation of the panel leading up to the failure of the panel for specimens fabricated from 2195. High-speed cameras were used to capture the initiation of the failure. Finite element models were developed using an isotropic strain-hardening material model. Good agreement was observed between the measured and predicted responses for both alloys.

Haynie, Waddy T.↗

Studies of Shear Band Velocity Using Spatially and Temporally Resolved Measurements of Strain During Quasistatic Compression of Bulk Metallic Glass

We have made measurements of the temporal and spatial features of the evolution of strain during the serrated flow of Pd{sub 40}Ni{sub 40}P{sub 20} bulk metallic glass tested under quasistatic, room temperature, uniaxial compression. Strain and load data were acquired at rates of up to 400 kHz using strain gages affixed to all four sides of the specimen and a piezoelectric load cell located near the specimen. Calculation of the displacement rate requires an assumption about the nature of the shear displacement. If one assumes that the entire shear plane displaces simultaneously, the displacement rate is approximately 0.002 m/s. If instead one assumes that the displacement occurs as a localized propagating front, the velocity of the front is approximately 2.8 m/s. In either case, the velocity is orders of magnitude less than the shear wave speed ({approx}2000 m/s). The significance of these measurements for estimates of heating in shear bands is discussed.

36 MATERIALS SCIENCE↗

Correction of Specimen Strain Measurement in Kolsky Tension Bar Experiments on Work-Hardening Materials

Cylindrical dog-bone (or dumbbell) shaped samples have become a common design for dynamic tensile tests of ductile materials with a Kolsky tension bar. When a direct measurement of displacement between the bar ends is used to reveal the specimen strain, the actual strain in the specimen gage section is overestimated due to strain in the specimen shoulder and needs to be corrected. The currently available correction method works well for elastic-perfectly plastic materials but may not be applicable to materials that exhibit significant work-hardening behavior. Here, we developed a new specimen strain correction method for materials possessing an elastic-plastic with linear work-hardening stress-strain response. A Kolsky tension bar test of a Fe-49Co-2V alloy (known by trade names Hiperco and Permendur) was used to demonstrate the new specimen strain correction method. This new correction method was also used to correct specimen strains in Kolsky tension bar experiments on two other materials: 4140 alloy, and 304L-VAR stainless steel, which had different work-hardening behavior.

36 MATERIALS SCIENCE↗