Search NASA⌕ Search

SEARCH · Search NASA

Results for “Data Collection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

A priori checking of the light-response and data quality before extended data collection in pump–probe photocrystallography experiments

In picosecond and slower pump–probe diffraction experiments, collection of response–ratio correlation sets prior to full data collection provides an invaluable confirmation of the existence of a light-induced signal prior to full data collection. If a response to light exposure is observed, the quality of the data being collected can be assessed. We present a number of such correlation plots both for synchrotron and in-house pump–probe data collection.

Coppens, Philip↗

Adaptable SEC‐SAXS data collection for higher quality structure analysis in solution

Abstract The two major challenges in synchrotron size‐exclusion chromatography coupled in‐line with small‐angle x‐ray scattering (SEC‐SAXS) experiments are the overlapping peaks in the elution profile and the fouling of radiation‐damaged materials on the walls of the sample cell. In recent years, many post‐experimental analyses techniques have been developed and applied to extract scattering profiles from these problematic SEC‐SAXS data. Here, we present three modes of data collection at the BioSAXS Beamline 4–2 of the Stanford Synchrotron Radiation Lightsource (SSRL BL4‐2). The first mode, the High‐Resolution mode, enables SEC‐SAXS data collection with excellent sample separation and virtually no additional peak broadening from the UHPLC UV detector to the x‐ray position by taking advantage of the low system dispersion of the UHPLC. The small bed volume of the analytical SEC column minimizes sample dilution in the column and facilitates data collection at higher sample concentrations with excellent sample economy equal to or even less than that of the conventional equilibrium SAXS method. Radiation damage problems during SEC‐SAXS data collection are evaded by additional cleaning of the sample cell after buffer data collection and avoidance of unnecessary exposures through the use of the x‐ray shutter control options, allowing sample data collection with a clean sample cell. Therefore, accurate background subtraction can be performed at a level equivalent to the conventional equilibrium SAXS method without requiring baseline correction, thereby leading to more reliable downstream structural analysis and quicker access to new science. The two other data collection modes, the High‐Throughput mode and the Co‐Flow mode, add agility to the planning and execution of experiments to efficiently achieve the user's scientific objectives at the SSRL BL4‐2.

Matsui, Tsutomu↗

Offshore Geologic Carbon Storage Data Collection and International Project Inventory

We present an interactive data collection to aggregate, understand, and disseminate the data that are publicly available to support offshore GCS which can be leveraged by stakeholders to understand where GCS may be viable offshore, create GCS project analogs, and address challenges to GCS in offshore environments. The Offshore Geologic Carbon Storage Data Collection is an Experience Builder web application of multiple web mapping applications, aggregated into a single tool for each data type for access, visualization, and exploration. We also present a spatial inventory of global offshore GCS efforts to visualize the scale and locations of actualized and potential offshore GCS. It includes project location, project type and stage, CO2 storage resource potential, injection rate, reservoir and seal geology, and key literature references. Quantitative and qualitative comparisons of the distribution and magnitude of projects by their attributes lends spatial insight into the status of global GCS operations and storage resource potential, thereby enabling comparative assessments and cross-cutting knowledge transfer for projects in development. These datasets illuminate trends in ongoing offshore projects and can be leveraged by stakeholders to estimate storage resources, identify subsurface analogs, review regulations, and address challenges to offshore GCS. Additionally, opportunities for concurrent decarbonization strategies can be identified.

Mulhern, Julia↗

Surface and Buried Thermal, and RGB Unexploded Ordnance Data Collection

This document provides a description of a data collection campaign of unexploded ordnance (UXOI) set. The dataset captures a controlled UAV imaging campaign designed to support detection of UXO across varied environmental conditions. Data were collected during three campaigns in Norris and Northeast Knoxville, Tennessee, using RGB, and thermal sensors mounted on Parrot UKR. In total, the dataset contains 9925 images, 26 full-motion video, and approximately 81.99 GB of data, collected across late spring/summer conditions, every hour during sunlight, and multiple surface contexts, including tall grass, short grass, gravel, as well as buried in sand, and other gravel mixtures. The collection was designed to capture thermal and visual variability relevant to UXO detection in agricultural land, bare earth, and subsurface. Review of the imagery showed that ordnance was most detectable during periods of changing solar input, especially approximately 10-60 minutes after sunrise, approximately 20-60 minutes after sunset, and 2-3 min after cloud cover interrupted prolonged solar heating. These conditions increased thermal contrast because many ordnance items retained or released heat differently than the surrounding vegetation and ground surface. This dataset provides a useful resource for developing and evaluating airborne UXO detection methods under realistic field conditions. All ordnance used in the study was inert, and thermal behavior may differ from that of live ordnance. In addition, variation in ordnance type, composition, and placement introduced differences in thermal response that should be considered when interpreting results.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Modeling performance of data collection systems for high-energy physics

Exponential increases in scientific experimental data are outpacing silicon technology progress, necessitating heterogeneous computing systems—particularly those utilizing machine learning (ML)—to meet future scientific computing demands. The growing importance and complexity of heterogeneous computing systems require systematic modeling to understand and predict the effective roles for ML. We present a model that addresses this need by framing the key aspects of data collection pipelines and constraints and combining them with the important vectors of technology that shape alternatives, computing metrics that allow complex alternatives to be compared. For instance, a data collection pipeline may be characterized by parameters such as sensor sampling rates and the overall relevancy of retrieved samples. Alternatives to this pipeline are enabled by development vectors including ML, parallelization, advancing CMOS, and neuromorphic computing. By calculating metrics for each alternative such as overall F1 score, power, hardware cost, and energy expended per relevant sample, our model allows alternative data collection systems to be rigorously compared. We apply this model to the Compact Muon Solenoid experiment and its planned high luminosity-large hadron collider upgrade, evaluating novel technologies for the data acquisition system (DAQ), including ML-based filtering and parallelized software. The results demonstrate that improvements to early DAQ stages significantly reduce resources required later, with a power reduction of 60% and increased relevant data retrieval per unit power (from 0.065 to 0.31 samples/kJ). However, we predict that further advances will be required in order to meet overall power and cost constraints for the DAQ.

Olin-Ammentorp, Wilkie (ORCID:0000000224729862)↗

A review of preserving privacy in data collected from buildings with differential privacy

Significant amounts of data are collected in buildings. While these data have great potential for maximizing the energy efficiency of buildings in general, only a small portion of the data are accessible to researchers, government, and industry for analyses. Concerns about privacy are one of the major barriers prohibiting access to these data. Privacy preservation techniques are generally applied to this problem not only to preserve underlying privacy but also to improve the usefulness of data. Among various privacy preserving techniques, differential privacy has become one of the more popular solutions since its introduction in 2006. Differential privacy is a mathematical measure for protecting privacy so that one's privacy cannot be incurred by participating in a database. Additionally, although significant research improvements have been made for more than a decade, applying differential privacy to data collected in buildings is still an immature field of study. Because implementing differential privacy on a certain use case is not straightforward and can be achieved with various configurations, it is important to understand variation of configurations with different use cases around data collected from buildings. This literature review aims to introduce what has been done to implement differential privacy in data collected in buildings, and to discuss associated challenges and potential future research opportunities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An Approach to Dynamic Human Reliability Analysis and Its Data Collection Framework

Human reliability analysis (HRA) is a method for evaluating human errors in a variety of complex systems such as nuclear power plants, military systems, aircraft, and chemical plants. Most HRA methods currently used by regulatory institutes or utilities are called static HRA and are carried out by simple worksheets or simple calculators. To date, there are many unsolved or intrinsic challenges in static HRA. For example, existing static HRA does not realistically model and evaluate human actions as they would be performed at actual systems. There is no method with HRA to objectively estimate the time required for human actions despite being essential to HRA processes. In addition, many HRA methods still rely on a dataset generated prior to the 1980s, from unrelated industry experience or simply from expert judgment. Accordingly, this study attempted to research how to overcome the challenges of existing HRA via dynamic risk assessment (a.k.a., simulation-based or computation-based risk assessment) techniques. First, this study developed a dynamic HRA method, named as PRocedure-based Investigation Method of EMRALD Risk Assessment – HRA (PRIMERA-HRA). The PRIMERA-HRA mainly concentrates on providing HRA analysts with specific guidelines on how to reasonably model human actions, assign human reliability data and evaluate output of simulation within a dynamic probabilistic risk assessment tool, called as Event Modeling Risk Assessment using Linked Diagrams (EMRALD). Second, this study also developed a module for performance shaping factors (i.e., the key concept in HRA quantification) applicable to dynamic HRA, then implemented it based on PRIMERA-HRA within the EMRALD tool. Third, this study developed an HRA data collection framework to support dynamic HRA, called as Simplified Human Error Experimental Program (SHEEP). Originally, the SHEEP study aimed to support static HRA and its data collection, but recently extended the scope to the new technologies such as dynamic HRA or HRA for advanced reactors. SHEEP focuses on the use of data collected from simplified simulators to complement—but not replace—data collection studies using full-scope simulators and actual operators. To date, many experiments were conducted under the SHEEP framework. Multiple analyses, such as human performance analysis, human error analysis, task complexity analysis, learning effect analysis and time distribution analysis, were also carried out using the collected data. Then, based on the major insights, an approach to inferring full-scope data based on simplified simulator data was proposed. The PRIMERA-HRA and SHEEP research are expected to evaluate human actions more realistically than existing static HRA, provide an opportunity to collect more HRA data with reasonable cost and labor, then contribute to enhance the quality of HRA.

99 - GENERAL AND MISCELLANEOUS↗

DOE Cold Climate Heat Pump Challenge Field Validation: Data Collection and Analysis Plan

This document details the data collection, storage, and analysis plan and methodologies for conducting the field validation portion of DOE’s Cold Climate Heat Pump (CCHP) Challenge. The study is focused on validating the in-field heating performance of prototypical CCHPs that have successfully demonstrated that they meet or exceed the Challenge specification in a laboratory setting. The units that have passed laboratory testing will be installed in real homes along with sensors and loggers for monitoring performance over an entire heating season. Data collected through monitoring will be cleaned and stored in a secure database. The data will be analyzed for calculating the key metrics defined by the Challenge including heating capacities at low outdoor air temperatures (below 32 °F), efficiency in terms of the Coefficient of Performance (COP), switchover temperatures and auxiliary heat staging. Demand Response (DR) capabilities will also be tested using specially designed DR events. In most cases, shoulder season and cooling season performance will also be determined and reported.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An Approach to Dynamic Human Reliability Analysis and Its Data Collection Framework

Human reliability analysis (HRA) is a method for evaluating human errors in a variety of complex systems such as nuclear power plants, military systems, aircraft, and chemical plants. Most HRA methods currently used by regulatory institutes or utilities are called static HRA and are carried out by simple worksheets or simple calculators. To date, there are many unsolved or intrinsic challenges in static HRA. For example, existing static HRA does not realistically model and evaluate human actions as they would be performed at actual systems. There is no method with HRA to objectively estimate the time required for human actions despite being essential to HRA processes. In addition, many HRA methods still rely on a dataset generated prior to the 1980s, from unrelated industry experience or simply from expert judgment. Accordingly, this study attempted to research how to overcome the challenges of existing HRA via dynamic risk assessment (a.k.a., simulation-based or computation-based risk assessment) techniques. First, this study developed a dynamic HRA method, named as PRocedure-based Investigation Method of EMRALD Risk Assessment – HRA (PRIMERA-HRA). The PRIMERA-HRA mainly concentrates on providing HRA analysts with specific guidelines on how to reasonably model human actions, assign human reliability data and evaluate output of simulation within a dynamic probabilistic risk assessment tool, called as Event Modeling Risk Assessment using Linked Diagrams (EMRALD). Second, this study also developed a module for performance shaping factors (i.e., the key concept in HRA quantification) applicable to dynamic HRA, then implemented it based on PRIMERA-HRA within the EMRALD tool. Third, this study developed an HRA data collection framework to support dynamic HRA, called as Simplified Human Error Experimental Program (SHEEP). Originally, the SHEEP study aimed to support static HRA and its data collection, but recently extended the scope to the new technologies such as dynamic HRA or HRA for advanced reactors. SHEEP focuses on the use of data collected from simplified simulators to complement—but not replace—data collection studies using full-scope simulators and actual operators. To date, many experiments were conducted under the SHEEP framework. Multiple analyses, such as human performance analysis, human error analysis, task complexity analysis, learning effect analysis and time distribution analysis, were also carried out using the collected data. Then, based on the major insights, an approach to inferring full-scope data based on simplified simulator data was proposed. The PRIMERA-HRA and SHEEP research are expected to evaluate human actions more realistically than existing static HRA, provide an opportunity to collect more HRA data with reasonable cost and labor, then contribute to enhance the quality of HRA.

99 - GENERAL AND MISCELLANEOUS↗

RokBase Core Facility Data Collection

The RokBase Core Facility Data Collection v1.0 is an aggregation of information on the locations and collections of geologic core facilities in the United States. It contains two spatial files, their corresponding attribute tables within a catalog, and an interactive web map and dashboard. It is intended to be used for research and comparison purposes, see full disclaimer and credits. Please contact NETL if revisions / corrections can be made to improve this dataset.

core facility location↗

High-throughput in situ X-ray screening of and data collection from protein crystals at room temperature and under cryogenic conditions

Protein crystallography has significantly advanced in recent years, with in situ data collection, in which crystals are placed in the X-ray beam within their growth medium, being a major point of focus. In situ methods eliminate the need to harvest crystals, a previously unavoidable drawback, particularly for often small membrane-protein crystals. Here, we present a protocol for the high-throughput in situ X-ray screening of and data collection from soluble and membrane-protein crystals at room temperature (20-25 degrees C) and under cryogenic conditions. The Mylar in situ method uses Mylar-based film sandwich plates that are inexpensive, easy to make, and compatible with automated imaging, and that show very low background scattering. They support crystallization in microbatch and vapor-diffusion modes, as well as in lipidic cubic phases (LCPs). A set of 3D-printed holders for differently sized patches of Mylar sandwich films makes the method robust and versatile, allows for storage and shipping of crystals, and enables automated mounting at synchrotrons, as well as goniometer-based screening and data collection. The protocol covers preparation of in situ plates and setup of crystallization trials; 3D printing and assembly of holders; opening of plates, isolation of film patches containing crystals, and loading them onto holders; basic screening and data-collection guidelines; and unloading of holders, as well as reuse and recycling of them. In situ plates are prepared and assembled in 1 h; holders are 3D-printed and assembled in <= 90 min; and an in situ plate is opened, and a film patch containing crystals is isolated and loaded onto a holder in 5 min.

36 MATERIALS SCIENCE↗

Integrated Data Collection Analysis (IDCA) Program - Statistical Analysis of RDX Standard Data Sets

The Integrated Data Collection Analysis (IDCA) program is conducting a Proficiency Test for Small- Scale Safety and Thermal (SSST) testing of homemade explosives (HMEs). Described here are statistical analyses of the results for impact, friction, electrostatic discharge, and differential scanning calorimetry analysis of the RDX Type II Class 5 standard. The material was tested as a well-characterized standard several times during the proficiency study to assess differences among participants and the range of results that may arise for well-behaved explosive materials. The analyses show that there are detectable differences among the results from IDCA participants. While these differences are statistically significant, most of them can be disregarded for comparison purposes to assess potential variability when laboratories attempt to measure identical samples using methods assumed to be nominally the same. The results presented in this report include the average sensitivity results for the IDCA participants and the ranges of values obtained. The ranges represent variation about the mean values of the tests of between 26% and 42%. The magnitude of this variation is attributed to differences in operator, method, and environment as well as the use of different instruments that are also of varying age. The results appear to be a good representation of the broader safety testing community based on the range of methods, instruments, and environments included in the IDCA Proficiency Test.

round-robin test↗

Fission TPC FY2020 Report (Mid Q2 FY2021): Preliminary 235 U(n,f)/ 6 Li(n,t)α Cross Section Ratio Analysis & Update on the 239 Pu(n,f) Data Collection

Fission TPC L2 Milestone Description: The fission TPC experimental campaign is in its final stages of collecting high precision (n,f) cross section data aimed at improving our understanding of the 239 Pu fission process. During FY 2019 235 U(n,f)/ 6 Li(n,t) ratio data collection began at WNR/LANSCE. This data is the first step in demonstrating the efficacy of 6 Li(n,t) as a diagnostic standard for a 239 Pu(n,f) ratio measurement. In FY 2020 and FY2021, the NIFFTE Collaboration will analyze 235 U(n,f)/ 6 Li(n,t) data already collected to establish this technique in preparation for 239 Pu(n,f)/ 6 Li(n,t) ratio data. Additionally, the ability to vapor deposit 239 Pu was developed in 2019, greatly improving target quality. As access to experimental facilities allows, 239 Pu/ 235 U and 239 Pu/ 6 Li data will be collected to provide new inputs for evaluation of the 239 Pu(n,f) cross section.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A New Method for High Resolution Surface Change Detection: Data Collection and Validation of Measurements from UAS at the Nevada National Security Site, Nevada, USA

The use of uncrewed aerial systems (UAS) increases the opportunities for detecting surface changes in remote areas and in challenging terrain. Detecting surface topographic changes offers an important constraint for understanding earthquake damage, groundwater depletion, effects of mining, and other events. For these purposes, changes on the order of 5–10 cm are readily detected, but sometimes it is necessary to detect smaller changes. An example is the surface changes that result from underground explosions, which can be as small as 3 cm. Previous studies that described change detection methodologies were generally not aimed at detecting sub-5-cm changes. Additionally, studies focused on high-fidelity accuracy were either computationally modeled or did not fully provide the necessary examples to highlight the usability of these workflows. Detecting changes at this threshold may be critical in certain applications, such as global security research and monitoring for high-consequence natural hazards, including landslides. Here we provide a detailed description of the methodology we used to detect 2–3 cm changes in an important applied research setting—surface changes related to underground explosions. This methodology improves the accuracy of change detection data collection and analysis through the optimization of pre-field planning, surveying, flight operations, and post-processing the collected data, all of which are critical to obtaining the highest output data resolution possible. We applied this methodology to a field study location, collecting 1.4 Tb of images over the course of 30 flights, and location data for 239 ground control points (GCPs). We independently verified changes with orthoimagery, and found that structure-from-motion, software-reported root mean square errors (RMSEs) for both control and check points underestimated the actual error. We found that 3 cm changes are detectable with this methodology, thereby improving our knowledge of a rock’s response to underground explosions.

47 OTHER INSTRUMENTATION↗

PANSOPHY, a JLAB SRF engineering data management system, supporting data collection, retrieval and analysis utilized by LCLS-II

Pansophy is an Engineering Data Management System that provides a comprehensive solution for managing information in the production and testing of cryomodules. It is especially suited to supporting the Data & Quality Management Systems for large projects like LCLS-II. With extensive amounts of data collected for an individual project, data retrieval to facilitate feedback and enhancement of production and processing activities is a high priority. The priority shares importance with the needs of managing the project, including production status, NCR, and Quality Management reports. Recent Pansophy enhancements have been to Data and Quality management reports and statistical analysis. Such enhancements include a database driven menu system, extended MSWord macro and preprocessing of travelers, and an extensive reporting system. The reporting system allows managers and group leaders to quickly respond to the needs of the project in areas of cavity and cryomodule production, data collection, NCR, Quality Management and schedule. Extensions include integration with the SRF inventory system PRIMeS, allowing traceability from receiving of manufactured parts to final cryomodule product.

Bookwalter, Valerie D.↗

Forward problem solution as the operator of filtered and back projection matrix to reconstruct the various method of data collection and the object element model in electrical impedance tomography

Back projection reconstruction has been implemented to get the dynamical image in electrical impedance tomography. However the implementation is still limited in method of adjacent data collection and circular object element model. The study aims to develop the methods of back projection as reconstruction method that has the high speed, accuracy, and flexibility, which can be used for various methods of data collection and model of the object element. The proposed method uses the forward problem solution as the operator of filtered and back projection matrix. This is done through a simulation study on several methods of data collection and various models of the object element. The results indicate that the developed method is capable of producing images, fastly and accurately for reconstruction of the various methods of data collection and models of the object element.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗