Search NASA⌕ Search

SEARCH · Search NASA

Results for “Data acquisition systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Data-Acquisition System With Remotely Adjustable Amplifiers

Improved data-acquisition system has both centralized and decentralized characteristics developed. Provides infrastructure for automation and standardization of operation, maintenance, calibration, and adjustment of many transducers. Increases efficiency by reducing need for diminishing work force of highly trained technicians to perform routine tasks. Large industrial and academic laboratory facilities benefit from systems like this one.

Nurge, Mark A.↗

Advanced Video Data-Acquisition System For Flight Research

Advanced video data-acquisition system (AVDAS) developed to satisfy variety of requirements for in-flight video documentation. Requirements range from providing images for visualization of airflows around fighter airplanes at high angles of attack to obtaining safety-of-flight documentation. F/A-18 AVDAS takes advantage of very capable systems like NITE Hawk forward-looking infrared (FLIR) pod and recent video developments like miniature charge-couple-device (CCD) color video cameras and other flight-qualified video hardware.

Miller, Geoffrey↗

MODAQ (Modular Offshore Data Acquisition System) [SWR-24-58]

The National Renewable Energy Laboratory (NREL) has developed a data acquisition system to support laboratory (component) and in-water validation and testing of Marine Renewable Energy (MRE) technologies. The Modular Ocean Data AcQuisition System (MODAQ) is a robust system built on industrial grade hardware that can acquire high-quality and summary data from many sensor and instrument types. MODAQ includes modules to perform real-time QC screening, system health monitoring, and send alerts. MODAQ is also part of a larger data management, processing, visualization, and archiving system.

Raye, Robert↗

Update of the Development of a Low Cost Data Acquisition System for the Space Shuttle Solid Rocket Booster Program

The space shuttle solid rocket boosters (SRBs) experience a severe environment during their brief flight. During the last few years several SRB's have sustained noticeable structural damage. The environmental characteristics (vibration, structure, and thermal) encountered by the SRB's during ascent, descent and water impact are in most cases unknown. A developmental flight instrumentation (DFI) system collected data from the SRBs' first four flights in the early 1980's, and after the first three flights during the shuttle return-to-flight phase after the Challenger accident. However, the DFI data collected are of low fidelity and do not correlate well with cases of observed structural damage. The DFI system was evaluated for reuse, but the cost to fly it was prohibitive. The space shuttle is presently scheduled to fly until 2030. To support the shuttle flight schedule, avionics on the SRB's will be upgraded. The environments on the different sections of the SRB will need to be defined more completely to properly qualify the avionics for multiple flights. The DFI data previously gathered do not provide enough information to properly qualify the avionics. Marshall Space Flight Center's (MSFC) SRB Project Office requested the Science and Engineering (S&E) Directorate to develop a stand-alone data acquisition system that could collect data from any area of the booster. In answer to this requirement, S&E developed the Enhanced Data Acquisition System (EDAS). To minimize development time and cost, the development team used state-of-the-art commercial off the shelf (COTS) equipment. The first two flights of this system occurred on shuttle mission STS-91 in June 1998 and STS-95 in October 1998. Twenty-one measurements were successfully recorded on the STS-91 right hand booster, providing new accelerometer, strain, temperature, and heating rate data to analysts. Twenty-four measurements were successfully recorded on the STS-95 left hand booster, providing data from the booster and the external tank. This paper summarizes the effort to develop, test, qualify and fly the EDAS to meet SRB flight and data collection requirements.

Crawford, Kevin↗

Using a Commerical off the Shelf Data Acquisition System for the Space Shuttle Solid Rocket Booster Program

The space shuttle solid rocket boosters (SRBs) experience a severe environment during their brief flight. During the last few years several SRB's have sustained noticeable structural damage. The environmental characteristics (vibration, structure, and thermal) encountered by the SRB's during ascent, descent and water impact are in most cases unknown. A developmental flight instrumentation (DFI) system collected data from the SRBs' first four flights in the early 1980's, and after the first three flights during the shuttle return-to-flight phase after the Challenger accident. However, the DFI data collected are of low fidelity and do not correlate well with cases of observed structural damage. The DFI system was evaluated for reuse, but the cost to fly it was prohibitive. The space shuttle is presently scheduled to fly until 2030. To support the shuttle flight schedule, avionics on the SRB's will be upgraded. The environments on the different sections of the SRB will need to be defined more completely to properly qualify the avionics for multiple flights. The DFI data previously gathered do not provide enough information to properly qualify the avionics. Marshall Space Flight Center's (MSFC) SRB Project Office requested the Science and Engineering (S&E) Directorate to develop a stand-alone data acquisition system that could collect data from any area of the booster. In answer to this requirement, S&E developed the Enhanced Data Acquisition System (EDAS). To minimize development time and cost, the development team used state-of-the-art commercial off the shelf (COTS) equipment. The first two flights of this system occurred on shuttle mission STS-91 in June 1998 and STS-95 in October 1998. Twenty-one measurements were successfully recorded on the STS-91 right hand booster, providing new accelerometer, strain, temperature, and heating rate data to analysts. Twenty-four measurements were successfully recorded on the STS-95 left hand booster, providing data from the booster and the external tank. This paper summarizes the effort to develop, test, qualify and fly the EDAS to meet SRB flight and data collection requirements.

Crawford, Kevin↗

Development of a Low Cost Data Acquisition System for the Solid Rocket Booster Program

The Space Transportation System's (STS) Solid Rocket Boosters (SRBs) experience a severe environment during their brief flight. During the last few years several SRB's have sustained noticeable structural damage. The environmental characteristics (vibration, structure, and thermal) encountered by the SRB's during ascent, descent and water impact are in most cases unknown. A developmental flight instrumentation (DFI) system collected data from the SRB's first four flights in the early 1980's, and after the first three flights during the shuttle return-to-flight phase after the Challenger accident. However, the DFI data collected are of low fidelity and do not correlate well with the observed structural damage. The DFI system was evaluated for reuse, but the cost to fly it was prohibitive. The STS is presently scheduled to fly until 2030. To support the STS schedule the avionics on SRB's will be upgraded. The environments on the different sections of the SRB will need to be defined to properly qualify the avionics for multiple flights. The DFI data previously gathered does not provide enough information to properly qualify the avionics. Marshall Space Flight Centers (MSFC) SRB Project Office requested the Science and Engineering Directorate to develop a self contained data acquisition system that could collect data from any area of the booster. This paper summarizes the effort to develop, test, qualify and fly an Enhanced Data Acquisition System (EDAS) using state-of-the-art commercial off the shelf (COTS) equipment. The first flight of this system occurred on shuttle mission STS-91 in June 1998.

Crawford, Kevin↗

The Lick Observatory CCD data acquisition system

An evolving system for CCD data acquisition is described. The electronics are subdivided into those attached to the dewar, a 'smart' controller near the dewar, and a computer connected by serial link to the smart controller. Software for the smart controller is in assembler code, while the data acquisition and on-line analysis software is written in 'C' and uses the UNIX operating system.

Robinson, L. B.↗

Space Shuttle tracking and data acquisition system

NASA's plans for the Space Shuttle tracking and data acquisition system are described. The limitations of the techniques now used for tracking and data acquisition support of earth orbiting spacecraft are discussed. NASA's solution to these limitations, the Tracking and Data Relay Satellite System, is described. The system's geometrical coverage and technical characteristics are explained. Operation of the system for Space Shuttle support is described in overview terms.

Robinson, L. M.↗

Low-power triggered data acquisition system and method

A low-power triggered data acquisition system and method utilizes low-powered circuitry, comparators, and digital logic incorporated into a miniaturized device interfaced with self-generating transducer sensor inputs to detect, identify and assess impact and damage to surfaces and structures wherein, upon the occurrence of a triggering event that produces a signal greater than a set threshold changes the comparator output and causes the system to acquire and store digital data representative of the incoming waveform on at least one triggered channel. The sensors may be disposed in an array to provide triangulation and location of the impact.

Champaigne, Kevin↗

Wind tunnel real-time data acquisition system

The hardware configuration is described for the data acquisition system (DAS) which consists of an analog front end that can process up to 260 channels of data, a multichannel analog-to-digital subsystem that can process up to 50,000 samples of data per second, and a digital computer with standard and nonstandard devices, including graphics capability. Also described are the software configuration of the DAS and complex hardware/software interfaces providing, for example, automatic amplifier gain and offset adjustment for each data channel. Specific DAS applications are summarized, including the real time processing of dynamic deflection data, unsteady pressure measurements, and flutter and buffet data.

Cole, P.↗

Olympus propagation studies in the US: Receiver development and the data acquisition system

Virginia Tech has developed two types of receivers to monitor the Olympus beacons, as well as a custom data acquisition system to store and display propagation data. Each of the receiver designs uses new hybrid analog/digital techniques. The data acquisition system uses a stand alone processor to collect and format the data for display and subsequent processing. The launch of the Olympus satellite with its coherent beacons offers new opportunities to study propagation effects at 12.5, 20, and 30 GHz. At Virginia Tech, the satellite is at 14 degrees in elevation, which allows us to measure low elevation angle effects. However, to make these measurements, a very accurate and stable measurement system is required. Virginia Tech has constructed a complex receiving system which monitors the Olympus beacons and all parameters associated with propagation research. In the current configuration, researchers have developed a receiver which frequency locks to the less fade susceptible 12.5 GHz beacon. Since all beacons on the satellite are driven from a single master oscillator, drift in the 12.5 GHz beacon implies corresponding drifts in the 20, and 30 GHz beacons. The receivers for the 20 and 30 GHz systems derive their frequency locking information from the 12.5 GHz system. This widens the dynamic range of the receivers and allows the receivers to maintain lock in severe fade conditions. In addition to monitoring the beacons, the sky noise is monitored with radiometers at each frequency. The radiometer output is used to set the clear air level for each beacon measurement. Researchers also measure the rain rate with several tipping bucket rain gauges placed along the propagation path.

Mckeeman, John C.↗

A Unified User-Friendly Instrument Control and Data Acquisition System for the ORNL SANS Instrument Suite

In an effort to upgrade and provide a unified and improved instrument control and data acquisition system for the Oak Ridge National Laboratory (ORNL) small-angle neutron scattering (SANS) instrument suite—biological small-angle neutron scattering instrument (Bio-SANS), the extended q-range small-angle neutron scattering diffractometer (EQ-SANS), the general-purpose small-angle neutron scattering diffractometer (GP-SANS)—beamline scientists and developers teamed up and worked closely together to design and develop a new system. We began with an in-depth analysis of user needs and requirements, covering all perspectives of control and data acquisition based on previous usage data and user feedback. Our design and implementation were guided by the principles from the latest user experience and design research and based on effective practices from our previous projects. In this article, we share details of our design process as well as prominent features of the new instrument control and data acquisition system. The new system provides a sophisticated Q-Range Planner to help scientists and users plan and execute instrument configurations easily and efficiently. The system also provides different user operation interfaces, such as wizard-type tool Panel Scan, a Scripting Tool based on Python Language, and Table Scan, all of which are tailored to different user needs. The new system further captures all the metadata to enable post-experiment data reduction and possibly automatic reduction and provides users with enhanced live displays and additional feedback at the run time. We hope our results will serve as a good example for developing a user-friendly instrument control and data acquisition system at large user facilities.

47 OTHER INSTRUMENTATION↗

DAQMAN - A flexible configurable data acquisition system

DAQMAN is a flexible configurable interface that allows the user to build and operate a VME-based data acquisition system on a Linux workstation. It consists of two parts: a Java-based Graphical User Interface to configure the system, and a C-based utility that reads out the data and creates the output ASCII data file, with two levels of diagnostic tools. The data acquisition system requires a CAEN CONET-VME Bridge to communicate between the hardware in the VME crate and the Linux workstation. Data acquisition modules, such as ADCs, TDC, Scalers, can be loaded into the system, or removed easily. The GUI allows users to activate modules, and channels within modules by clicking on icons. Running configurations are stored; data are collected and can be viewed either as raw numbers, or by charts and histograms that update as the data are accumulated. Data files are written to disk in ASCII format, with a date and time stamp.

Sivertz, Michael↗

DAQMAN - A flexible configurable data acquisition system

DAQMAN is a flexible configurable interface that allows the user to build and operate a VME-based data acquisition system on a Linux workstation. It consists of two parts: a Java-based Graphical User Interface to configure the system, and a C-based utility that reads out the data and creates the output ASCII data file, with two levels of diagnostic tools. The data acquisition system requires a CAEN CONET-VME Bridge to communicate between the hardware in the VME crate and the Linux workstation. Data acquisition modules, such as ADCs, TDC, Scalers, can be loaded into the system, or removed easily. The GUI allows users to activate modules, and channels within modules by clicking on icons. Running configurations are stored; data are collected and can be viewed either as raw numbers, or by charts and histograms that update as the data are accumulated. Data files are written to disk in ASCII format, with a date and time stamp.

Sivertz, Michael↗

Systolic time interval data acquisition system. Specialized cardiovascular studies

The development of a data acquisition system for noninvasive measurement of systolic time intervals is described. R-R interval from the ECG determines instantaneous heart rate prior to the beat to be measured. Total electromechanical systole (Q-S2) is measured from the onset of the ECG Q-wave to the onset of the second heart sound (S2). Ejection time (ET or LVET) is measured from the onset of carotid upstroke to the incisure. Pre-ejection period (PEP) is computed by subtracting ET from Q-S2. PEP/ET ratio is computed directly.

Baker, J. T.↗

Upgrading the 14x22 Data Acquisition System (DAS)

The 14-by 22-Foot Subsonic Tunnel recently completed development and installation of a new Data Acquisition System for use in the tunnel and in the Rotor Test Cell (RTC). Planning and development of this new system has been ongoing for several years, and installation was performed over this past year. This effort also required an upgrade of the facility infrastructure to support the upgraded power and cooling requirements. This presentation summarizes the new data acquisition system, improved capabilities, challenges of installation, and proposed future enhancements to the system.

wind tunnel↗

Fully digital data acquisition system for the neutron time-of-flight spectrometer TOFOR at JET

A prototype of a fully digital data acquisition system based on 1 Gsps 12 bit digitizers for the TOFOR fusion neutron spectrometer at JET is assessed. The prototype system enables the use of geometry-based background discrimination techniques, which are modeled, evaluated, and compared to experimental data. The experimental results are in line with the models and show a significant improvement in signal-to-background ratio in measured time-of-flight spectrum compared to the existing data acquisition system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗