Search NASASearch

SEARCH · Search NASA

Results for “Data frames”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Snow cover monitoring by machine processing of multitemporal LANDSAT MSS data

LANDSAT frames were geometrically corrected and data sets from six different dates were overlaid to produce a 24 channel (six dates and four wavelength bands) data tape. Changes in the extent of the snowpack could be accurately and easily determined using a change detection technique on data which had previously been classified by the LARSYS software system. A second phase of the analysis involved determination of the relationship between spatial resolution or data sampling frequency and accuracy of measuring the area of the snowpack.

Luther, S. G.

Method for Enhancing a Three Dimensional Image from a Plurality of Frames of Flash LIDAR Data

A method for enhancing a three dimensional image from frames of flash LIDAR data includes generating a first distance R(sub i) from a first detector i to a first point on a surface S(sub i). After defining a map with a mesh theta having cells k, a first array S(k), a second array M(k), and a third array D(k) are initialized. The first array corresponds to the surface, the second array corresponds to the elevation map, and the third array D(k) receives an output for the DEM. The surface is projected onto the mesh theta, so that a second distance R(sub k) from a second point on the mesh theta to the detector can be found. From this, a height may be calculated, which permits the generation of a digital elevation map. Also, using sequential frames of flash LIDAR data, vehicle control is possible using an offset between successive frames.

Vanek, Michael D.

Precise Time-Tag Generator For A Local-Area-Network Monitor

Time-tag-generating circuit designed for use in LAN monitor, monitors frames of data transmitted among computers on local-area network (LAN). To each frame of data that LAN monitor receives from LAN, time-tag generator appends ancillary data on time of arrival of frame, precise to within 1 microsecond of centrally generated time signal. Inserts ancillary time data in place of already used frame-check data before frames of data stored in memory of LAN monitor.

Stauffer, David R.

Determination of the inner planet frame tie using VLBI data

The problem of connecting the independent reference frames formed by the planetary ephemeris and the radio source catalog is one of growing importance to spacecraft navigation. Using quasar-relative VLBI delay data collected by the Deep Space Network, and Soviet coherent data from the Venus flyby of the Soviet Vega 1 and 2 spacecraft, a self-consistent estimate of the frame tie offset has been found, along with its uncertainty.

Mcelrath, Timothy P.

General Solution for Theoretical Packet Data Loss Rate

Communications systems which transfer blocks ("frames") of data must use a marker ("frame synchronization pattern") for identifying where a block begins. A technique ("frame synchronization strategy") is used to locate the start of each frame and maintain synchronization as additional blocks are processed. A device which strips out the frame synchronization pattern [FSP] and provides an "end of frame" pulse is called a frame synchronizer. As clock and data errors are introduced into the system, the start-of-block marker becomes displaced and/or corrupted. The capability of the frame synchronizer to stay locked to the pattern under these conditions is a figure of merit for the frame synchronization strategy. It is important to select a strategy which will stay locked nearly all the time at bit error rates where the data is usable. ("Bit error rate" [BER] is the fraction of binary bits which are inverted by passage through a communication system.) The fraction of frames that are discarded because the frame synchronizer is not locked is called "Percent Data Loss" or "Packet Data Loss rate" [PDL]. A general approach for accurately predicting PDL given BER was developed in Theoretical Percent Data Loss Calculation and Measurement Accuracy, T. P. Kelly, LESC-30554, December 1992. Kelly gave a solution in terms of matrix equations, and only addressed "level" channel encoding. This paper goes on to give a closed-form polynomial solution for the most common class of frame synchronizer strategies, and will also address "mark" and "space" (differential) channel encoding, and burst error environments. The paper is divided into four sections and follows a logically ordered presentation, with results developed before they are evaluated. However, most readers will derive the greatest benefit from this paper by treating the results as reference material. The result developed for differential encoding can be extended to other applications (like block codes) where the probability is needed that a block contains only a certain number of errors.

Lansdowne, Chatwin

Living Color Frame System: PC graphics tool for data visualization

Living Color Frame System (LCFS) is a personal computer software tool for generating real-time graphics applications. It is highly applicable for a wide range of data visualization in virtual environment applications. Engineers often use computer graphics to enhance the interpretation of data under observation. These graphics become more complicated when 'run time' animations are required, such as found in many typical modern artificial intelligence and expert systems. Living Color Frame System solves many of these real-time graphics problems.

Truong, Long V.

Laser Communications Relay Demonstration Optimetrics Experiment

Within this paper, we report on an Optimetrics experiment conducted on the National Aeronautics and Space Administration (NASA) Laser Communication Relay Demonstration (LCRD). The high precision two-way ranging is conducted on the optical communications link between the LCRD space terminal in a geosynchronous orbit and the Optical Ground Station 1 (OGS1) at Table Mountain, California, and is referred to as optimetrics ranging. The receiver to transmitter clock loopback is implemented in the LCRD space modem. A digital dual mixer time difference phase meter (DDMTD) is implemented in the OGS1 ground modem. The round-trip time is measured with the DDMTD by counting the frame and data clock ticks between transmitter and receiver frame synchronization markers for coarse range, and the relative phase of the transmit and receive clock for high precision range. This approach provides coverage for all potential ranges with no ranging ambiguity. The flight modem FPGA code was modified for frame and data clock loopback and the OGS1 FPGA code was modified for the DDMTD phase meter implementation. The experiment team conducted a 36-hour continuous ranging measurement. Preliminary two-way optimetrics ranging data show a noise floor of 3cm (rms). Based on our theoretical noise analysis and ground tests with spare flight modems, we expected one order of magnitude improvement on ranging precision. We are conducting detailed post data processing to identify the differences to further reduce the noise level and formulating an improved implementation approach for future missions. For reference and comparison, traditional Radio Frequency (RF) ranging between LCRD and OGS1 was conducted at the same time and indicates a ranging noise floor of 30cm(rms). Other telemetry and relevant environmental parameters such as weather and atmosphere temperature were also collected for offline data processing. The high precision ranging and range rate measurements from the laser communications data link clock and clock phase are performed simultaneously with continuous optical communication. No extra hardware added to existing system. This high precision optimetrics measurement implementation provides alternative ranging and range rate measurements for orbit determination (OD) and flight dynamics calculations with higher precision. We see significant improvement on OD for navigation upon implementation in future optical communication systems.

Rafael Garcia

Looking for systematic error in scale from terrestrial reference frames derived from DORIS data

The long-term stability of the scale of Terrestrial Reference Frames is directly linked with station height determination and is critical for several scientific studies, such as global mean sea level rise or ocean circulation with consequences on global warming studies. In recent International Terrestrial Reference Frame solutions, the DORIS technique was not sonsidered able to provide any useful information on scale. We have analyzed three different DORIS time series of coordinates performed independently using different software packages.

Terrestrial Reference Frame (TRF)

Application of time-variable process noise in terrestrial reference frames determined from VLBI data

In recent years, Kalman filtering has emerged as a suitable technique to determine terrestrial reference frames (TRFs), a prime example being JTRF2014. The time series approach allows variations of station coordinates that are neither reduced by observational corrections nor considered in the functional model to be taken into account. These variations are primarily due to non-tidal geophysical loading effects that are not reduced according to the current IERS Conventions (2010). It is standard practice that the process noise models applied in Kalman filter TRF solutions are derived from time series of loading displacements and account for station dependent differences. So far, it has been assumed that the parameters of these process noise models are constant over time. However, due to the presence of seasonal and irregular variations, this assumption does not truly reflect reality. In this study, we derive a station coordinate process noise model allowing for such temporal variations. This process noise model and one that is a parameterized version of the former are applied in the computation of TRF solutions based on very long baseline interferometry data. In comparison with a solution based on a constant process noise model, we find that the station coordinates are affected at the millimeter level.

Schuh, Harald

Recent Advances in Registration, Integration and Fusion of Remotely Sensed Data: Redundant Representations and Frames

In recent years, sophisticated mathematical techniques have been successfully applied to the field of remote sensing to produce significant advances in applications such as registration, integration and fusion of remotely sensed data. Registration, integration and fusion of multiple source imagery are the most important issues when dealing with Earth Science remote sensing data where information from multiple sensors, exhibiting various resolutions, must be integrated. Issues ranging from different sensor geometries, different spectral responses, differing illumination conditions, different seasons, and various amounts of noise need to be dealt with when designing an image registration, integration or fusion method. This tutorial will first define the problems and challenges associated with these applications and then will review some mathematical techniques that have been successfully utilized to solve them. In particular, we will cover topics on geometric multiscale representations, redundant representations and fusion frames, graph operators, diffusion wavelets, as well as spatial-spectral and operator-based data fusion. All the algorithms will be illustrated using remotely sensed data, with an emphasis on current and operational instruments.

Fusion

Methods and Apparatus for Aggregation of Multiple Pulse Code Modulation Channels into a Signal Time Division Multiplexing Stream

Methods and apparatus are provided for telemetry processing using a telemetry processor. The telemetry processor can include a plurality of communications interfaces, a computer processor, and data storage. The telemetry processor can buffer sensor data by: receiving a frame of sensor data using a first communications interface and clock data using a second communications interface, receiving an end of frame signal using a third communications interface, and storing the received frame of sensor data in the data storage. After buffering the sensor data, the telemetry processor can generate an encapsulated data packet including a single encapsulated data packet header, the buffered sensor data, and identifiers identifying telemetry devices that provided the sensor data. A format of the encapsulated data packet can comply with a Consultative Committee for Space Data Systems (CCSDS) standard. The telemetry processor can send the encapsulated data packet using a fourth and a fifth communications interfaces.

Chang, Chen J.

Frame sync acquisition for biorthogonally coded data

The paper analyzes the optimum frame-synchronization problem for biorthogonally coded data received over the additive white Gaussian noise (AWGN) channel and decoded prior to sync acquisition. In deriving the optimum frame-sync algorithm, the discussion is restricted to the case in which each frame contains F complete code words, including a frame-sync prefix of P complete code words. The k-bit source words and k-bit decoded words are regarded as super symbols from an alphabet of binary k-tuples. The biorthogonal encoder, the AWGN channel, and the decoder are lumped into a super symbol channel whose characteristics determine the form of the optimum frame-sync decision rule. A union-bound approach is used to provide a quantitative measure of the probability of false synchronization for the algorithm derived.

Levitt, B. K.

Dynamic Black-Level Correction and Artifact Flagging in the Kepler Data Pipeline

Instrument-induced artifacts in the raw Kepler pixel data include time-varying crosstalk from the fine guidance sensor (FGS) clock signals, manifestations of drifting moiré pattern as locally correlated nonstationary noise and rolling bands in the images which find their way into the calibrated pixel time series and ultimately into the calibrated target flux time series. Using a combination of raw science pixel data, full frame images, reverse-clocked pixel data and ancillary temperature data the Keplerpipeline models and removes the FGS crosstalk artifacts by dynamically adjusting the black level correction. By examining the residuals to the model fits, the pipeline detects and flags spatial regions and time intervals of strong time-varying blacklevel (rolling bands ) on a per row per cadence basis. These flags are made available to downstream users of the data since the uncorrected rolling band artifacts could complicate processing or lead to misinterpretation of instrument behavior as stellar. This model fitting and artifact flagging is performed within the new stand-alone pipeline model called Dynablack. We discuss the implementation of Dynablack in the Kepler data pipeline and present results regarding the improvement in calibrated pixels and the expected improvement in cotrending performances as a result of including FGS corrections in the calibration. We also discuss the effectiveness of the rolling band flagging for downstream users and illustrate with some affected light curves.

Clarke, B. D.

Radio reference frame stability from VLBI data

Intercontinental radio interferometric measurements between NASA's Deep Space Network stations yield a catalog of positions of 106 extragalactic radio sources, uniformly distributed between -45 and +85 deg declination. Almost all of the source positions have formal uncertainties between 0.5 and 3 milliarcseconds. Estimates of three independent sets of 32 source coordinates at average epochs 1980.0, 1983.2, and 1984.5 assess the level of stability of the reference frame over a five-year period. Comparisons of the three sets of source coordinates show a number of cases of greater than 2 sigma differences, particularly between the 1984-85 and 1981-83 periods. No sources, however, show 2 sigma shifts among both pairs of epochs. Upper limits of the order of 1 mas/yr can be placed on the time rates of change of the 32 source coordinates.

Sovers, O. J.

Simulated performance results of the OMV video compression telemetry system

The control system of NASA's Orbital Maneuvering Vehicle (OMV) will employ range/range-rate radar, a forward command link, and a compressed video return link. The video data is compressed by sampling every sixth frame of data; a rate of 5 frames/sec is adequate for the OMV docking speeds. Further axial compression is obtained, albeit at the expense of spatial resolution, by averaging adjacent pixels. The remaining compression is achieved on the basis of differential pulse-code modulation and Huffman run-length encoding. A concatenated error-correction coding system is used to protect the compressed video data stream from channel errors.

Ingels, Frank

Optimum frame synchronization for biorthogonally coded data

Many recent American unmanned planetary probes have used biorthogonally coded spacecraft-to-earth telemetry links. An examination of the frame-synchronization (sync) techniques employed on these missions revealed that they were not specifically designed for coded data. This led to a consideration of the optimum frame-sync problem for biorthogonally coded data received over the additive white Gaussian noise (AWGN) channel and decoded prior to sync acquisition. A frame-sync algorithm for biorthogonally coded data based on a super-symbol distance rule is proposed, along with a corresponding selection criterion for the sync sequence. It is argued heuristically that this approach is optimum with regard to minimizing the probability of false synchronization.

Levitt, B. K.