Determination of nitric oxide concentrations from sunrise E-region electron density measurements

Midlatitude sunrise electron density profiles have been analyzed in order to determine nitric oxide concentrations in the range 100-160 km. In general, the determinations are restricted to heights for which the ionization of nitric oxide by direct solar Lyman-alpha radiation is the main contribution to the growth of the E region. The concentrations obtained are larger, by factors of approximately 3 to 4, than those obtained from the midlatitude airglow measurements of other workers. Concentrations have been obtained from one sunset measurement and these are significantly lower than the sunrise values. The results also give a clear indication of increasing nitric oxide concentrations above 120 km with increasing solar activity.

Monro, P. E.↗

Density measurement in air with a saturable absorbing seed gas

A method for making density measurements in a compressible flow by using off resonance laser induced fluorescence is studied. The seed molecule chosen for study is the iodine molecule which is excited with the 514.5 nm line of the argon ion laser whose output is frequency tuned, by as much as 3 GHz, relative to a strong iodine transition using an intracavity etalon. The theory which was developed to analyze the effect will be used in conjunction with two experiments being conducted to further study the method an acoustic resonance tube in which controlled perturbations about a uniform state are produced, and a small supersonic jet in which the conditions of the flow vary widely from point to point.

Baganoff, D.↗

Instrument continuously measures density of flowing fluids

Electromechanical densitometer continuously measures the densities of either single-phase or two-phase flowing cryogenic fluids. Measurement is made on actual flow. The instrument operates on the principle that the mass of any vibrating system is a primary factor in determining the dynamic characteristics of the system.

Jacobs, R. B.↗

Current Density Measurements of an Annular-Geometry Ion Engine

The concept of the annular-geometry ion engine, or AGI-Engine, has been shown to have many potential benefits when scaling electric propulsion technologies to higher power. However, the necessary asymmetric location of the discharge cathode away from thruster centerline could potentially lead to non-uniformities in the discharge not present in conventional geometry ion thrusters. In an effort to characterize the degree of this potential nonuniformity, a number of current density measurements were taken on a breadboard AGI-Engine. Fourteen button probes were used to measure the ion current density of the discharge along a perforated electrode that replaced the ion optics during conditions of simulated beam extraction. Three Faraday probes spaced apart in the vertical direction were also used in a separate test to interrogate the plume of the AGI-Engine during true beam extraction. It was determined that both the discharge and the plume of the AGI-Engine are highly uniform, with variations under most conditions limited to 10% of the average current density in the discharge and 5% of the average current density in the plume. Beam flatness parameter measured 30 mm from the ion optics ranged from 0.85 0.95, and overall uniformity was shown to generally increase with increasing discharge and beam currents. These measurements indicate that the plasma is highly uniform despite the asymmetric location of the discharge cathode.

Shastry, Rohit↗

Current Density Measurements of an Annular-Geometry Ion Engine

The concept of the annular-geometry ion engine, or AGI-Engine, has been shown to have many potential benefits when scaling electric propulsion technologies to higher power. However, the necessary asymmetric location of the discharge cathode away from thruster centerline could potentially lead to non-uniformities in the discharge not present in conventional geometry ion thrusters. In an effort to characterize the degree of this potential non-uniformity, a number of current density measurements were taken on a breadboard AGI-Engine. Fourteen button probes were used to measure the ion current density of the discharge along a perforated electrode that replaced the ion optics during conditions of simulated beam extraction. Three Faraday probes spaced apart in the vertical direction were also used in a separate test to interrogate the plume of the AGI-Engine during true beam extraction. It was determined that both the discharge and the plume of the AGI-Engine are highly uniform, with variations under most conditions limited to +/-10% of the average current density in the discharge and +/-5% of the average current density in the plume. Beam flatness parameter measured 30 mm from the ion optics ranged from 0.85 - 0.95, and overall uniformity was shown to generally increase with increasing discharge and beam currents. These measurements indicate that the plasma is highly uniform despite the asymmetric location of the discharge cathode.

Shastry, Rohit↗

Silicon surface barrier detectors used for liquid hydrogen density measurement

Multichannel system employing a radioisotope radiation source, strontium-90, radiation detector, and a silicon surface barrier detector, measures the local density of liquid hydrogen at various levels in a storage tank. The instrument contains electronic equipment for collecting the density information, and a data handling system for processing this information.

James, D. T.↗

Density measurements from crossed beams at high extinction

The formulation of the crossed beam correlation technique is generalized to include strongly absorbing media. The first measurements of point density fluctuations at contact surfaces have been obtained. The presence of turbulent bursts is confirmed and a characteristic spectral frequency of approximately 400 Hz is estimated.

Johnson, J. A., III↗

A method of atmospheric density measurements during Shuttle entry using UV laser Rayleigh scattering

A detailed study is described of the performance capabilities and the hardware requirements for a method in which ambient density is measured along the Space Shuttle flight path using on-board optical instrumentation. The technique relies on Rayleigh scattering of light from a pulsed, ultraviolet, ArF excimer laser operating at a wavelength of 193 nm. The method is shown to be capable of providing direct measurements of ambient density with an uncertainty of less than 1 percent and with a spatial resolution of 1 km, over an altitude range from 50 to 90 km. In addition, extensions of this concept are discussed that allow measurements of the shock wave location and the density profile within the shock layer. Two approaches are identified that appear to be feasible, in which the same laser system is used for the extended measurements as that required for the ambient density measurements.

Mckenzie, Robert L.↗

Apollo-Soyuz O/3P/ and N/4S/ density measurement by UV spectroscopy

The densities of O(3P) and N(4S) at 225 km were determined during the Apollo-Soyuz Test Project by a resonance absorption-fluorescence technique in which O I and N I line radiation produced and collimated on board the Apollo was reflected from the Soyuz back to the Apollo for spectral analysis. The two spacecraft maneuvered so that a range of observation angles of plus or minus 25 deg with respect to the normal to the orbital velocity vector was scanned. The measurements described were made at night on two consecutive orbits at spacecraft separations of 150 and 500 m. The results indicate an O density of 1.15 billion per cu cm (plus or minus 30%), agreeing with mass-spectrometric measurements made under similar conditions, and an N density of 5.6 to 11.2 million per cu cm, in good agreement with recent measurements but suggesting a smaller diurnal variation than predicted by present models.

Donahue, T. M.↗

Measuring Density Of Air By Ultraviolet Rayleigh Scattering

Report presents theoretical and experimental studies directed toward development of optoelectronic instrument to measure density of air at altitudes from 50 to 90 km and possibly beyond. Instrument mounted in Space Shuttle orbiter and operated during reentry into atmosphere. Data gathered by instrument needed because density of upper atmosphere highly variable in space and time and this variability affects aerodynamic behavior and trajectory of reentering Shuttle. Variations in density also meteorologically significant.

Mckenzie, Robert L.↗

Exospheric density measurements from the drag-free satellite Triad

The Triad satellite is maintained within 1 mm of its proof mass (a small metal ball) in a purely gravitational orbit, using a drag-free control system, named Discos, as the disturbance compensation system. The Discos proof mass is surrounded by an outer shell which holds fuel tanks and cold gas jets. The shell shields the proof mass from such nongravitational forces as radiation pressure, atmospheric drag, and micrometeorite impact. Whenever these forces displace the outer shell relative to the proof mass, an error signal is generated by a capacitive bridge sensor, and the satellite is propelled by gas jets to remain centered on the proof mass when the error reaches 1 mm. Local atmospheric densities near 800 km were measured, using ball position data, and the observed accelerations were corrected for the effects of solar radiation pressure. The measured densities reveal a greater dependence on latitude than that indicated by balloon satellites, and also a dependence on longitude. Only a small dependence on Kp, however, was observed in the region where the measurements were made.

Moe, K.↗