Measurement of the transverse energy density in Measurement of the transverse energy density in Au + Au collisions at $\sqrt{𝑠_{𝑁⁢𝑁}}$ = 200 GeV with the sPHENIX detector

Here, this paper reports measurements of the transverse energy per unit pseudorapidity (𝑑⁢𝐸 𝑇 /𝑑⁢𝜂) produced in Au + Au collisions at $\sqrt{𝑠_{𝑁⁢𝑁}}$ = 200 GeV, performed with the sPHENIX detector at the Relativistic Heavy Ion Collider (RHIC). The results cover the pseudorapidity range |𝜂| < 1.1 and constitute the first such measurement performed using a hadronic calorimeter at RHIC. Measurements of 𝑑⁢𝐸 𝑇 /𝑑⁢𝜂 are presented for a range of centrality intervals and the average 𝑑⁢𝐸 𝑇 /𝑑⁢𝜂 as a function of the number of participating nucleons, 𝑁 part , is compared to a variety of Monte Carlo heavy-ion event generators. The results are in agreement with previous measurements at RHIC, and feature an improved granularity in 𝜂 and improved precision in low-𝑁 part events.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Cross-polarized common-path temporal interferometry for high-sensitivity strong-field ionization measurements

Absolute density measurements of low-ionization-degree or low-density plasmas ionized by lasers are very important for understanding strong-field physics, atmospheric propagation of intense laser pulses, Lidar etc. A cross-polarized common-path temporal interferometer using balanced detection was developed for measuring plasma density with a sensitivity of ∼0.6 mrad, equivalent to a plasma density-length product of ∼2.6 × 10 13 cm −2 if using an 800 nm probe laser. By using this interferometer, we have investigated strong-field ionization yield versus intensity for various noble gases (Ar, Kr, and Xe) using 800 nm, 55 fs laser pulses with both linear (LP) and circular (CP) polarization. The experimental results were compared to the theoretical models of Ammosov-Delone-Krainov (ADK) and Perelomov-Popov-Terent’ev (PPT). We find that the measured phase change induced by plasma formation can be explained by the ADK theory in the adiabatic tunneling ionization regime, while PPT model can be applied to all different regimes. We have also measured the photoionization and fractional photodissociation of molecular (MO) hydrogen. By comparing our experimental results with PPT and MO-PPT models, we have determined the likely ionization pathways when using three different pump laser wavelengths of 800 nm, 400 nm, and 267 nm.

47 OTHER INSTRUMENTATION↗

Quantitative measurements of density in shock-compressed silver up to 330 GPa using x-ray diffraction

This work presents a structural study of shock-compressed states in Ag to 331 GPa, accessed via laser shock compression. Structures of the resulting crystalline phases and the average atomic distribution of the liquid state are determined using in situ x-ray diffraction. We employ structure factor analysis, adapted for a non-monochromatic x-ray source, to determine the density of the liquid phase from analysis of x-ray diffraction data for the first time in shock compressed Ag. We also present a detailed analysis of the crystalline phases, which shows good agreement with the phase boundaries reported in previous experimental and theoretical works. We utilize the whole powder pattern fitting approach implemented in the MAUD package to constrain stacking faults in the face centered cubic structure. We observe the ambient fcc structure up to a stress of 146 GPa before a transition to a body-centered cubic structure and liquid phase at 179 GPa, with full melting above 212 GPa.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Measurements of Density and Sound Speed in Mixtures Relevant to Supercritical CO2 Cycles

Abstract The objective of this research is to validate properties of mixtures relevant to supercritical carbon dioxide (sCO2) power cycles. Direct-fired sCO2 cycles are a promising technology for the future power generation systems. The working fluid of sCO2 cycles will be near and above critical point of CO2. One of the challenges is that the simulation of mixtures should consider real gas behavior. Expected operating conditions of Allam cycles reach up to 300 bar and 1000 °C. Characterizing the mixtures at the extreme conditions is an important issue in current researches and industrial applications. Thermophysical properties of mixtures may be beyond the valid range of the widely used database such as NIST REFPROP. Experimental data of mixture properties in the literature are limited which is necessary to develop high-fidelity design tools for sCO2 power cycles. We measured the density and sound speed of several multi-component mixtures. A temperature-controlled high-pressure test cell was used for the density measurements. Sound speed was measured by resonant frequency detection using an external speaker and a piezoelectric pressure sensor. Mixtures studied in this work include carbon dioxide, methane, oxygen, and water vapor. Properties of pure CO2 were measured to show the validity of our technique. Compositions were selected to be close to frozen mixtures at the inlet, mid-progress, and exhaust conditions of a model sCO2 combustor in the previous numerical simulation work. Corresponding reaction progress variables (RPV) were RPV = 0, 0.5, and 1. Temperature and pressure conditions of experiments are 310–450 K and 0–150 bar. In our study, density and sound speed from the NIST REFPROP database agree with experimental measurements within the range of our measurement uncertainties.

Energy & Fuels↗

Optical transmission and dimensional stability of single-crystal sapphire after high-dose neutron irradiation at various temperatures up to 688 °C

The use of single-crystal sapphire optical fibers has been considered to extend fiber-optic sensing to the extreme temperature (>1000 °C) environments encountered in nuclear applications. However, before these sapphire fiber–based sensors can be deployed, their optical transmission and dimensional stability (which impacts drift of some sensors) must be characterized under representative testing conditions. Data regarding the optical transmission of sapphire following high-dose neutron irradiation at temperatures >100 °C is extremely limited. This work provides measurements of optical density (i.e., attenuation) and directional dimensional changes in bulk single-crystal sapphire materials irradiated to a fast neutron fluence of 2.4 × 10 21 n/cm 2 (3.5 displacements per atom) at temperatures ranging from 95 to 688 °C. Optical density measured after irradiation at 95 and 298 °C showed ultraviolet and visible absorption bands corresponding to known defect centers and temperature trends that were generally consistent with previous ex situ and in situ measurements made at much lower neutron fluence. However, optical density measured after irradiation at 688 °C was as much as two orders of magnitude higher, indicating that the fundamental mechanism for radiation-induced attenuation changes at this irradiation temperature. Additional analysis and comparison with previous works suggest that the attenuation may result from void formation, leading to increased Rayleigh scattering losses in the material and increased swelling that would also result in drift of Bragg grating-based sensors in sapphire fibers. These results pose serious questions regarding the feasibility of sapphire fiber–based sensors for high-temperature nuclear applications.

36 MATERIALS SCIENCE↗

Characterizing particle-based thermal storage performance using optical methods for use in next generation concentrating solar power plants

Concentrating Solar Power (CSP) generation is an attractive option for low-emission power generation; however, the high costs of thermal storage associated with concentrating solar create a large barrier for their use and adaptation into modern life. Lowering their operation costs, while maintaining high thermal storage and transfer performance is essential. Solid particle-based heat exchange systems can reduce CSP cost but are often less efficient. Efforts to increase their performance have led to use of binary size particle mixes. Presented is an optical-based thermal analysis technique used to measure near-wall thermal conductivity of particle beds essential in determining their heat exchanger efficiency. Modulated Photothermal Radiometry is used to make dynamic temperature measurements, allowing for the extraction of the most relevant thermal properties like thermal conductivity, specific heat, and effusivity. The system uses a modulated laser source causing a damped periodic heat flux, resulting in a frequency and thermal property dependent surface temperature, of which is measured using radiometry. Lock-In techniques are used to extrapolate the amplitude of the signal. Plotting the amplitude against the root angular frequency allows for effusivity measurement by ratio to a known sample. Using specific heat measurements from literature and density measurements, the thermal conductivity of the particle mixes can be calculated. The simplicity of MPTR to probe through the depth of the bed is ideal for use in CSP for dynamic thermal performance monitoring.

Corona, Javier↗

Measuring the Density Fields around Bright Quasars at z ~ 6 with XQR-30 Spectra

Measuring the density of the intergalactic medium using quasar sight lines in the epoch of reionization is challenging due to the saturation of Ly α absorption. Near a luminous quasar, however, the enhanced radiation creates a proximity zone observable in the quasar spectra where the Ly α absorption is not saturated. In this study, we use 10 high-resolution ( R ≳ 10,000) z ~ 6 quasar spectra from the extended XQR-30 sample to measure the density field in the quasar proximity zones. We find a variety of environments within 3 pMpc distance from the quasars. We compare the observed density cumulative distribution function (CDF) with models from the Cosmic Reionization on Computers simulation and find a good agreement between 1.5 and 3 pMpc from the quasar. This region is far away from the quasar hosts and hence approaching the mean density of the universe, which allows us to use the CDF to set constraints on the cosmological parameter σ 8 = 0.6 ± 0.3. The uncertainty is mainly due to the limited number of high-quality quasar sight lines currently available. Utilizing the more than 200 known quasars at z ≳ 6, this method will allow us to tighten the constraint on σ 8 to the percent level in the future. In the region closer to the quasar within 1.5 pMpc, we find that the density is higher than predicted in the simulation by 1.23 ± 0.17, suggesting that the typical host dark matter halo mass of a bright quasar ( M 1450 < -26.5) at z ~ 6 is .

79 ASTRONOMY AND ASTROPHYSICS↗

Design of radial interferometer–polarimeter for internal magnetic and density fluctuation measurements at multiple space–time scales in the National Spherical Torus Experiment-Upgrade (NSTX-U)

A Faraday-effect radial interferometer–polarimeter is designed for the National Spherical Torus Experiment-Upgrade (NSTX-U) to measure multiscale magnetic and density fluctuations critical to understanding fusion plasma confinement and stability, including those originating from magnetohydrodynamic instabilities, energetic particle-driven modes, and turbulence. The diagnostic will utilize the three-wave technique with 5 MHz bandwidth to simultaneously measure line-integrated magnetic and density fluctuations up to the ion-cyclotron frequency. Probe beams will be launched radially from the low-field side at the NSTX-U midplane, where the measured Faraday fluctuations mainly correspond to radial magnetic fluctuations that directly link to magnetic transport. A correlation technique will be employed to reduce the measurement noise to below 0.01° enabling detection of small amplitude fluctuations. Two toroidally displaced chords with 7° separation will be installed to measure toroidal mode numbers up to n = 25 for mode identification. Finally, solid-state microwave sources operating at 321 μm (935 GHz) will be used to minimize the impact of the Cotton–Mouton effect.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Solubility Predictions for Hanford Tank Concentrates with HSC - 20459

The commercially available Outotec HSC 9.9.0{sup R} provides excellent predictions for the solubilities of many species for Hanford waste tank concentrates. The HSC solubility predictions with a Harvie activity model agreed well with five boildowns that showed solubility limits for NaNO{sub 3}, NaNO{sub 2}, Na{sub 2}CO{sub 3}, NaF, Na{sub 2}SO{sub 4}, and Na{sub 3}PO{sub 4}. However, the HSC did not predict density and therefore water content very well and therefore we used the measured densities and derived water content from the difference between measured density and assays. Furthermore, we adjusted the HSC enthalpy for the minor species Na{sub 3}PO{sub 4}*NaF double salt in order to fit the five boildowns as well. Previous work has shown that gibbsite becomes and remains supersaturated in all of these boildowns and so there was no alumina precipitation despite supersaturation. Furthermore, an equilibrium model like HSC always shows complete oxidation of any TOC in the presence of nitrate and nitrite. We therefore suppressed the HSC oxidation of acetate and oxalate in order to fit measured acetate and oxalate solubilities as TOC. Space in Hanford waste tanks is very limited and therefore evaporator campaigns continue to recover needed tank space from dilute tank liquids. Prior to each evaporator campaign, a boildown of a sample of tank liquid for each campaign provides a basis for planning by measuring density, water activity, soluble species, and solids precipitation as a function of concentration at 18 deg. C. These boildowns then provide validations and calibrations for the HSC solubility prediction for Hanford wastes. Previous work has shown the solubilities of minor electrolytes in these five boildowns follow rather simple power law solubility products. Hanford's 222-S laboratory has reported each of five boildowns for concentrated liquids from five waste tanks and tank blends. All boildowns eventually showed the precipitation of the dominant electrolyte, NaNO{sub 3}, and overall solution activity largely drives all solubility. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Feasibility study of a high spatial and time resolution beam emission spectroscopy diagnostic for localized density fluctuation measurements in Lithium Tokamak eXperiment-β (LTX-β)

Trapped electron mode (TEM) is the main source of turbulence predicted for the unique operation regime of a flat temperature profile under low-recycling conditions in the LTX-β tokamak, while ion temperature gradient driven turbulence may also occur with gas fueling from the edge. To investigate mainly TEM scale density fluctuations, a high spatial and time resolution 2D beam emission spectroscopy (BES) diagnostic is being developed. Apart from spatially localized density turbulence measurement, BES can provide turbulence flow and flow shear dynamics. This BES system will be realized using an avalanche photodiode-based camera and narrow band interference filter. The system can acquire data at 2 MHz. Simulations with the Simulation of Spectra (SOS) code indicate that a high signal to noise ratio can be achieved with the proposed system. This will enable sampling the density fluctuations at this high time resolution. Finally, the design considerations and system optimization using the SOS code are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High resolution density pedestal measurements during edge localized modes by short-pulse reflectometry in the TCV tokamak

This publication presents high spatio-temporal resolution (mm/μs) density profile measurements of the pedestal top during type I, III, and small edge localized mode (ELM) H-mode plasmas in the Tokamak à Configuration Variable (TCV). These measurements were performed using a novel short-pulse reflectometer. Average inter-ELM density profiles are obtained via conditional averaging using the Dα trace as ELM indicator. Changes to the pedestal density profile gradients prior to type-III ELMs reveal unique pedestal dynamics leading to the ELM crash which can provide important experimental data for validation of non-linear MHD ELM simulations. The small-ELM scenario is found to feature a ∼25-35 kHz quasi-coherent density fluctuation near the separatrix rho_psi ∼0.993-1.05 not observed during a similar type-I ELM discharge. This oscillation is also found in low-field-side magnetic pick- up probes displaying a ballooning character and n=+1 toroidal mode number. This oscillation could help explain the markedly different pedestal dynamics observed in the small-ELM regime.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High resolution density pedestal measurements during edge localized modes by short-pulse reflectometry in the TCV tokamak

Here, this publication presents high spatio-temporal resolution (mm µs -1 ) density profile measurements of the pedestal top during type I, III, and small edge localized mode (ELM) H-mode plasmas in the tokamak à configuration variable (TCV). These measurements were performed using a novel short-pulse reflectometer. Average inter-ELM density profiles are obtained via conditional averaging using the D α trace as ELM indicator. Changes to the pedestal density profile gradients prior to type-III ELMs reveal unique pedestal dynamics leading to the ELM crash which can provide important experimental data for validation of non-linear MHD ELM simulations. The small-ELM scenario is found to feature a ~25–35 kHz quasi-coherent density fluctuation near the separatrix ρ ψ 0.993–1.05 not observed during a similar type-I ELM discharge. This oscillation is also found in low-field-side magnetic pick-up probes displaying a ballooning character and n = +1 toroidal mode number. This oscillation could help explain the markedly different pedestal dynamics observed in the small-ELM regime.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Thermophysical Property Measurements: Improved Density, Viscosity and Thermal Diffusivity Methods

The technical bases and methods developed at Argonne to measure thermophysical properties of molten salt mixtures are summarized and representative results provided to show the accuracy and precision achieved. Three key measurements addressed in this report are density, viscosity and thermal diffusivity. The densities of two eutectic FLiNaK mixtures were measured at temperatures to approximately 750 °C and the results are compared with literature values. The results are used to show how the effect of salt surface tension is taken into account in the density calculation and how the surface tension for other salt mixtures is being measured. Viscosity measurements of eutectic FLiNaK are shown to illustrate improvements to the measurement method being made to address and minimize the sources of error and uncertainties in the reported values. Thermal diffusivity measurements of FLiNaK are shown to illustrate the measurement method developed at Argonne and the achieved precision. The thermal diffusivity of the graphite used to make the cells that contain the salts during analyses was measured to assess the relative contribution to the response. The improved procedures developed in this work are being applied in property measurements of other salts of interest.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

New methodology for measuring electron density perturbations caused by plasma coherent modes using profile reflectometry: Magnitudes and radial profiles in DIII-D

New capabilities of fast-sweep frequency-modulated profile reflectometry are explored to measure electron density ne perturbation magnitudes and radial profiles due to plasma coherent modes in DIII-D. The first approach is based on the frequency analysis of phase perturbations associated with high frequency (~MHz) Alfvén eigenmodes (AEs). The measurement of ~5.5 MHz fast-ion-driven global Alfvén eigenmodes (GAEs) is demonstrated in a neutral beam-heated DIII-D plasma. The GAE induced a broad radial distribution of phase perturbations in the profile reflectometer data. Analysis of these data determined the effective cutoff location displacement and the estimated ne fluctuation profile. In the second approach, high resolution ne profiles are used directly to determine the radial structure of ne perturbations due to a neo-classical tearing mode. These new measurements broaden the application of profile reflectometry and advance the development of AE spectroscopy as a tool for non-invasive diagnosis of fast-ion-driven modes in DIII-D and burning plasmas such as ITER.

47 OTHER INSTRUMENTATION↗

Development and application of a low-noise, high-speed optical detector module for carbon density fluctuation measurements on Wendelstein 7-X

A low-noise, high-speed optical detector module is characterized and successfully commissioned for the measurement of high-frequency, low-intensity beam emission on Wendelstein 7-X (W7-X). An ultra-narrow bandpass optical filter is employed to selectively transmit the desired emission line while suppressing broadband plasma background emissions. Carbon density fluctuations are investigated by observing the carbon C-VI emission line (n = 8 → 7, λ ∼ 529 nm), arising from charge exchange (CX) between the neutral beam atoms and the intrinsic carbon population. Here, we present the characterization of the optical detector module and experimental measurements of carbon density fluctuations using available fibers on W7-X. The initial performance of the detector is presented in both active and passive CX measurements of intrinsic carbon density fluctuations. The low frequency dynamics of fluctuation is observed in response to the neutral beam and the pellet injection, demonstrating that the optical detector module is capable of providing a sufficient signal level with an adequate signal-to-noise ratio. In the upcoming OP2.4 campaign, this optical detector module will be adapted for use in a beam emission spectroscopy system by replacing the optical bandpass filter with one centered at 654 nm (90% transmission: 653–655.3 nm), which facilitates two-dimensional measurements of ion gyro-scale turbulence on W7-X.

Charge exchange recombination spectroscopy↗

Verification and validation of the open-source plasma fluid code: Zapdos

Zapdos is an open-source finite element plasma fluid solver based on the MOOSE multiphysics framework. This paper outlines Zapdos verification, benchmarking, and validation efforts for 1D and 2D RF capacitively coupled plasma discharge models for mid-range pressures (0.1 - 1 Torr). The verification process involved using the method of manufactured solutions to assess Zapdos spatial and temporal error convergence. L2 errors ranged from 10 -2 to 10 -4 , while the convergence’s slope were in agreement with the predicted slopes for the tested variable and time integration orders. The benchmarking process involved comparisons to previously results from the validated finite element code, LSODI. These works included 1D and 2D simulations for a range of plasma parameters (densities, temperatures, voltage, etc.). For the 1D cases, Zapdos and LSODI results were in very good agreement. In the 2D cases, variable behaviors matched, with slight discrepancies in peak values. The validation process involved comparisons to experimental works including electron density measurements by microwave interferometry and metastable density measurements by planar laser-induced fluorescence imaging. Results shown reasonable agreement at higher pressure, with results starting to diverge at low pressures. Furthermore, probable causes for this diverges are the limitation of the fluid assumption for plasmas at low pressure, or the need for more robust boundary conditions. Overall, Zapdos shown reasonable results for the verification, benchmarking, and validation efforts, and Zapdos can be downloaded at https://github.com/shannon-lab/zapdos.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurements of Density of Liquid Oxides with an Aero-Acoustic Levitator

Densities of liquid oxide melts with melting temperatures above 2000 °C are required to establish mixing models in the liquid state for thermodynamic modeling and advanced additive manufacturing and laser welding of ceramics. Accurate measurements of molten rare earth oxide density were recently reported from experiments with an electrostatic levitator on board the International Space Station. In this work, we present an approach to terrestrial measurements of density and thermal expansion of liquid oxides from high-speed videography using an aero-acoustic levitator with laser heating and machine vision algorithms. The following density values for liquid oxides at melting temperature were obtained: Y 2 O 3 4.6 ± 0.15; Yb 2 O 3 8.4 ± 0.2; Zr 0.9 Y 0.1 O 1.95 4.7 ± 0.2; Zr 0.95 Y 0.05 O 1.975 4.9 ± 0.2; HfO 2 8.2 ± 0.3 g/cm 3 . The accuracy of density and thermal expansion measurements can be improved by employing backlight illumination, spectropyrometry and a multi-emitter acoustic levitator.

36 MATERIALS SCIENCE↗

A novel method to measure ion density in ICF experiments using x-ray spectroscopy of cylindrical tracers

The indirect drive approach to inertial confinement fusion has undergone important advances in the past few years. Improvements in temperature and density diagnostic methods are leading to more accurate measurements of the plasma conditions inside the Hohlraum and therefore to more efficient experimental designs. The implementation of dot spectroscopy has proven to be a versatile approach to extracting space- and time-dependent electron temperatures. In this method, a microdot of a mid-Z material is placed inside the Hohlraum and its K-shell emission spectrum is used to determine the plasma temperature. However, radiation transport of optically thick lines acting within the cylindrical dot geometry influences the outgoing spectral distribution in a manner that depends on the viewing angle. This angular dependence has recently been studied in the high energy density regime at the OMEGA laser facility, which allowed us to design and benchmark appropriate radiative transfer models that can replicate these geometric effects. By combining these models with the measurements from the dot spectroscopy experiments at the National Ignition Facility, we demonstrate here a novel technique that exploits the transport effects to obtain time-resolved measurements of the ion density of the tracer dots, without the need for additional diagnostics. Furthermore, we find excellent agreement between experiment and simulation, opening the possibility of using these geometric effects as a density diagnostic in future experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗