Search NASA⌕ Search

SEARCH · Search NASA

Results for “Diffraction limited”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Overcoming Dynamic Disturbances in Imaging Systems

We develop and discuss a methodology with the potential to yield a significant reduction in complexity, cost, and risk of space-borne optical systems in the presence of dynamic disturbances. More robust systems almost certainly will be a result as well. Many future space-based and ground-based optical systems will employ optical control systems to enhance imaging performance. The goal of the optical control subsystem is to determine the wavefront aberrations and remove them. Ideally reducing an aberrated image of the object under investigation to a sufficiently clear (usually diffraction-limited) image. Control will likely be distributed over several elements. These elements may include telescope primary segments, telescope secondary, telescope tertiary, deformable mirror(s), fine steering mirror(s), etc. The last two elements, in particular, may have to provide dynamic control. These control subsystems may become elaborate indeed. But robust system performance will require evaluation of the image quality over a substantial range and in a dynamic environment. Candidate systems for improvement in the Earth Sciences Enterprise could include next generation Landsat systems or atmospheric sensors for dynamic imaging of individual, severe storms. The technology developed here could have a substantial impact on the development of new systems in the Space Science Enterprise; such as the Next Generation Space Telescope(NGST) and its follow-on the Next NGST. Large Interferometric Systems of non-zero field, such as Planet Finder and Submillimeter Probe of the Evolution of Cosmic Structure, could benefit. These systems most likely will contain large, flexible optormechanical structures subject to dynamic disturbance. Furthermore, large systems for high resolution imaging of planets or the sun from space may also benefit. Tactical and Strategic Defense systems will need to image very small targets as well and could benefit from the technology developed here. We discuss a novel speckle imaging technique with the potential to separate dynamic aberrations from static aberrations. Post-processing of a set of image data, using an algorithm based on this technique, should work for all but the lowest light levels and highest frequency dynamic environments. This technique may serve to reduce the complexity of the control system and provide for robust, fault-tolerant, reduced risk operation. For a given object, a short exposure image is "frozen" on the focal plane in the presence of the environmental disturbance (turbulence, jitter, etc.). A key factor is that this imaging data exhibits frame-to-frame linear shift invariance. Therefore, although the Point Spread Function is varying from frame to frame, the source is fixed; and each short exposure contains object spectrum data out to the diffraction limit of the imaging system. This novel speckle imaging technique uses the Knox-Thompson method. The magnitude of the complex object spectrum is straightforward to determine by well-established approaches. The phase of the complex object spectrum is decomposed into two parts. One is a single-valued function determined by the divergence of the optical phase gradient. The other is a multi-valued function determined by, the circulation of the optical phase gradient-"hidden phase." Finite difference equations are developed for the phase. The novelty of this approach is captured in the inclusion of this "hidden phase." This technique allows the diffraction-limited reconstruction of the object from the ensemble of short exposure frames while simultaneously estimating the phase as a function of time from a set of exposures.

Young, Eric W.↗

Ultrahigh-accuracy body-pointing system for the Large Space Telescope

The Large Space Telescope (LST) is a 3-m diffraction-limited telescope. Pointing stability requirements necessary to assure diffraction-limited images are plus or minus 0.005 arc-sec, over possible experiment observation times of several hours. In order to determine whether these stringent pointing requirements could be met, a complex simulation model was defined which consisted of detailed dynamic representations of control moment gyros (CMGs) and reaction wheels (RWs), including their noise characteristics, dynamic sensor representations with sensor noise, shock mounts for the CMG actuators, a detailed representation of an image motion compensation (IMC) system, and a detailed flexible body structural model with all significant vehicle and solar panel bending modes. On the basis of both stability and performance studies utilizing this model, it was determined that a body-pointing system will meet LST requirements in the presence of CMG vibrational disturbances and sensor noise. The recommended system consists of three orthogonally mounted RWs for primary short-term control, and a cluster of CMG actuators for continuous RW desaturation and vehicle maneuvering.

Rybak, S. C.↗

High Sensitivity, High Angular Resolution Far-infrared Photometry from the KAO

Most of the luminosity of embedded sources is reemitted in the far-infrared continuum. Measurements in the far-infrared are essential to understand the energetics of the interstellar medium, and of star formation regions in particular. Measurements from the KAO, are made in diffraction limited beams that sample a spatial scale considerably smaller than that given by IRAS. The KAO instrument technology has matured to the point that the single scan limiting flux of IRAS at 100 micro can be reached in a diffraction limited beam in a single typical KAO observing leg. The far-infrared photometer system and selections of recent observations are presented.

Lester, D.↗

Wavefront preserving X-ray optics for Synchrotron and Free Electron Laser photon beam transport systems

We report in the last two decades, after the first light from the new Free Electron Lasers, either in the UV (FLASH and FERMI@Elettra) or X-ray (LCLS and SACLA), more and more new diffraction limited sources have been either constructed or planned. Third generation storage rings are upgraded to provide a more collimated, brighter, and coherent light for the next generation experimental techniques. X-ray optics are the bridge between the light sources and the experimental stations. They are the key to the success of advanced experiments but also the potential bottleneck preventing the exploitation of the full characteristics of the source. The beam degradation originated by any mirror defect (either from mirror polishing or from contamination) is amplified with a coherent source. Delivering diffraction-limited spots, including the option for variable spot sizes in and out of focus, requires the control of the surface of the optics at the 1 nm rms level, if not better. At LCLS, only very recently an almost perfectly uniform beam out of focus has been obtained in the hard X-rays. It has been obtained after two 1-m long mirrors with 0.5 nm rms shape precision (after installation). Those mirrors were not readily available just a decade ago. But, thanks to the pioneering work performed at the Osaka University, those optics are now commercially available with arbitrary tangential profiles. This new generation of mirrors permits achieving unprecedented results. However, they do not remove all road blocks to a perfect photon transport system. Instead, they highlighted the critical importance of mirror mounting, handling of the thermal deformation, and the need of advanced diagnostics to properly exploit all the new potentiality of these optics. Besides the need of “perfect” mirrors, other aspects of the beamline design and elements may impact the quality of the beam in the experimental station, from the lack of blaze gratings to the need of advanced simulation tools, just to cite two. In this article, after a brief historical excursus, we will present the current state of the art of mirrors, gratings, crystals, lenses, diagnostics, and simulation tools. The main problems yet to solve and a look ahead at what would be achievable in the next decade will give the reader an idea on the search for an almost ideal photon transport system and how the path toward experiments, not conceivable today, will unfold.

47 OTHER INSTRUMENTATION↗

50 Mb/s, 220-mW Laser-Array Transmitter

Laser transmitter based on injection locking produces single-wavelength, diffraction-limited, single-lobe beam. Output stage is array of laser diodes producing non-diffraction-limited, multi-mode beam in absence of injection locking. Suitable for both free-space and optical-fiber communication systems. Because beam from transmitter focused to spot as small as 5 micrometers, devices usable for reading and writing optical disks at increased information densities. Application also in remote sensing and ranging.

Cornwell, Donald M., Jr.↗

Detector Arrays for an Airborne Infrared Echelle Spectrometer

The design of a long-slit echelle spectrograph covering the 16 - 210 micron range for use on the Stratospheric Observatory for Infrared Astronomy (SOFIA) is under study at NASA-Ames. This wavelength range is selected for its content of important astrophysical spectral lines accessible from an airborne platform, and availability of suitable detectors. Two dimensional arrays will be used to simultaneously provide spectral coverage in the dispersion direction and imaging in the cross-dispersion direction. Major goals are: (1) to reach sensitivities limited primarily by the background from the residual atmosphere and the telescope; (2) to provide imaging not far from the diffraction limit of the 2.5 meter (effective) aperture of the telescope; and (3) to obtain diffraction-limited spectral resolution from the large echelle grating, which means that the resolving power increases with decreasing wavelength. To meet these requirements, three detector types are forseen: a commercially available monolithic Si:Sb IBC array to cover the wavelength range from 16 to 40 microns, a Ge:Sb photoconductor array to cover the range from 40 to 125 microns, and a stressed Ge:Ga photoconductor array covering the range from 125 to 210 microns. The paper discusses details of the studies and plans for the field optics, detectors, and readouts.

Erickson, E. F.↗

Speckle imaging for planetary research

The present study of speckle imaging technique effectiveness encompasses image reconstruction by means of a division algorithm for Fourier amplitudes, and the Knox-Thompson (1974) algorithm for Fourier phases. Results which have been obtained for Io, Titan, Pallas, Jupiter and Uranus indicate that spatial resolutions lower than the seeing limit by a factor of four are obtainable for objects brighter than Uranus. The resolutions obtained are well above the diffraction limit, due to inadequacies of the video camera employed. A photon-counting camera has been developed to overcome these difficulties, making possible the diffraction-limited resolution of objects as faint as Charon.

Nisenson, P.↗

Design and analysis of a fast, two-mirror soft-x-ray microscope

During the past several years, a number of investigators have addressed the design, analysis, fabrication, and testing of spherical Schwarzschild microscopes for soft-x-ray applications using multilayer coatings. Some of these systems have demonstrated diffraction limited resolution for small numerical apertures. Rigorously aplanatic, two-aspherical mirror Head microscopes can provide near diffraction limited resolution for very large numerical apertures. The relationships between the numerical aperture, mirror radii and diameters, magnifications, and total system length for Schwarzschild microscope configurations are summarized. Also, an analysis of the characteristics of the Head-Schwarzschild surfaces will be reported. The numerical surface data predicted by the Head equations were fit by a variety of functions and analyzed by conventional optical design codes. Efforts have been made to determine whether current optical substrate and multilayer coating technologies will permit construction of a very fast Head microscope which can provide resolution approaching that of the wavelength of the incident radiation.

Shealy, D. L.↗

Optical observations of the sun from a solar probe

The spatial resolution of solar surface structure to ultimate limits with simple instrumentation. The logic is simple: a 10 cm aperture telescope at 4 solar radii resolves the equivalent of a five meter telescope in earth orbit. Given the ease of producing a diffraction limited 10 cm telescope and the difficulty of fabricating a diffraction limited 5 meter telescope, the performance of the small telescope could well be better. The telescope described complements planned solar orbiting telescopes in earth orbit and would need only a few arcs seconds of pointing.

Zirin, H.↗

Visible-to-THz near-field nanoscopy

Optical microscopy has a key role in research, development and quality control across a wide range of scientific, technological and medical fields. However, diffraction limits the spatial resolution of conventional optical instruments to about half the illumination wavelength. A technique that surpasses the diffraction limit in the wide spectral range between visible and terahertz frequencies is scattering-type scanning near-field optical microscopy (s-SNOM). The basis of s-SNOM is an atomic force microscope in which the tip is illuminated with light from the visible to the terahertz spectral range. By recording the elastically tip-scattered light while scanning the sample below the tip, s-SNOM yields near-field optical images with a remarkable resolution of 10 nm, simultaneously with the standard atomic force microscopic topography image. This resolution is independent of the illumination wavelength, rendering s-SNOM a versatile nanoimaging and nanospectroscopy technique for fundamental and applied studies of materials, structures and phenomena. This Review presents an overview of the fundamental principles governing the measurement and interpretation of near-field contrasts and discusses key applications of s-SNOM. We also showcase emerging developments that enable s-SNOM to operate under various environmental conditions, including cryogenic temperatures, electric and magnetic fields, electrical currents, strain and liquid environments. Furthermore, all these recent developments broaden the applicability of s-SNOMs for exploring fundamental solid-state and quantum phenomena, biological matter, catalytic reactions and more.

Hillenbrand, Rainer [CIC nanoGUNE BRTA and Departm↗

Low-cost Large Aperture Telescopes for Optical Communications

Low-cost, large-aperture optical receivers are required to form an affordable optical ground receiver network for laser communications. Among the ground receiver station's multiple subsystems, here, we only discuss the ongoing research activities aimed at reducing the cost of the large-size optics on the receiver. Experimental results of two different approaches for fabricating low-cost mirrors of wavefront quality on the order of 100-200X the diffraction limit are described. Laboratory-level effort are underway to improve the surface figure to better than 20X the diffraction limit.

telescope↗

Image restoration and superresolution as probes of small scale far-IR structure in star forming regions

Far-infrared continuum studies from the Kuiper Airborne Observatory are described that are designed to fully exploit the small-scale spatial information that this facility can provide. This work gives the clearest picture to data on the structure of galactic and extragalactic star forming regions in the far infrared. Work is presently being done with slit scans taken simultaneously at 50 and 100 microns, yielding one-dimensional data. Scans of sources in different directions have been used to get certain information on two dimensional structure. Planned work with linear arrays will allow us to generalize our techniques to two dimensional image restoration. For faint sources, spatial information at the diffraction limit of the telescope is obtained, while for brighter sources, nonlinear deconvolution techniques have allowed us to improve over the diffraction limit by as much as a factor of four. Information on the details of the color temperature distribution is derived as well. This is made possible by the accuracy with which the instrumental point-source profile (PSP) is determined at both wavelengths. While these two PSPs are different, data at different wavelengths can be compared by proper spatial filtering. Considerable effort has been devoted to implementing deconvolution algorithms. Nonlinear deconvolution methods offer the potential of superresolution -- that is, inference of power at spatial frequencies that exceed D lambda. This potential is made possible by the implicit assumption by the algorithm of positivity of the deconvolved data, a universally justifiable constraint for photon processes. We have tested two nonlinear deconvolution algorithms on our data; the Richardson-Lucy (R-L) method and the Maximum Entropy Method (MEM). The limits of image deconvolution techniques for achieving spatial resolution are addressed.

Lester, D. F.↗

Glass mirrors for space telescopes

The Hubble Space Telescope uses a primary mirror having an area of 5 sq m. The mirrors needed for two possible future telescopes, 50 sq m and 500 sq m in area, are considered. The former would be an 8-m diameter monolithic mirror of 'zero-expansion' glass, and would be diffraction-limited at optical wavelengths (0.015 arcsecond images). The 500 sq m mirror, the area proposed for the Large Deployable Reflector, would be diffraction-limited down to 30-micron wavelength (0.3 arcsecond images). Both types of mirror could be of honeycomb sandwich construction made by a new 'air inflation' method. The larger reflector would consist of ultralightweight glass panels.

Angel, J. R. P.↗

15 meter multiple mirror telescope design study

Taking as a starting point the existing Multiple Mirror Telescope (MMT), a concept for a larger and more advanced instrument has been developed. It makes use of four 7.5-m diameter paraboloidal glass primaries of the honeycomb sandwich type being developed by the University of Arizona. These are mounted quite close together in a square configuration, with their axes coaligned. Separate optical configurations are provided, for optical and infrared applications. To minimze telescope emissivity in the thermal infrared at the combined focus, all the beam combining and streering optics that follow the tertiary mirrors are enclosed in a large central dewar and cooled with liquid nitrogen. The diffraction-limited resolution at the combined focus of 0.11 arcsec at 10 micrometers wavelength is equivalent to that of a 20.5 meter filled aperture. Diffraction-limited resolution should be routinely achievable at 10 and 20 micrometers, if active correction of large-scale wavefront errors is implemented.

Angel, J. R. P.↗

Machine learning assisted quantum super-resolution microscopy

One of the main characteristics of optical imaging systems is spatial resolution, which is restricted by the diffraction limit to approximately half the wavelength of the incident light. Along with the recently developed classical super-resolution techniques, which aim at breaking the diffraction limit in classical systems, there is a class of quantum super-resolution techniques which leverage the non-classical nature of the optical signals radiated by quantum emitters, the so-called antibunching super-resolution microscopy. This approach can ensure a factor of $\sqrt{n}$ improvement in the spatial resolution by measuring the n -th order autocorrelation function. The main bottleneck of the antibunching super-resolution microscopy is the time-consuming acquisition of multi-photon event histograms. We present a machine learning-assisted approach for the realization of rapid antibunching super-resolution imaging and demonstrate 12 times speed-up compared to conventional, fitting-based autocorrelation measurements. The developed framework paves the way to the practical realization of scalable quantum super-resolution imaging devices that can be compatible with various types of quantum emitters.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Coherent summation of saturated AlGaAs amplifiers

Coherent summation of the output of two saturated traveling-wave amplifiers, each injected from a common semiconductor laser and all operated CW, has resulted in a single diffraction-limited beam containing 93 percent of the power originally contained in the two individual amplified beams. The 372 mW of power in a single diffraction-limited lobe is a 1.5-fold enhancement over the power available from a single amplifier.

Schuster, Gregory L.↗

Dimensional stability

The temporal stability of glass and glass-ceramic materials is important to the success of a large diffraction-limited telescope. The results are presented of an experimental study of the dimensional stability of glasses and glass ceramics being considered for substrates of massive diffraction-limited mirrors designed for several years of service in earth orbit. The purpose of the study was to measure the relative change in length of the candidate substrate materials, to the order of 5 parts in 10 to the 8th power, as a function of several years time. The development of monolithic test etalons, the development and improvement of two types of ultra-high precision interferometers, and certain aspects of tests data presently achieved are discussed.

Hocken, R.↗

High resolution observations of low contrast phenomena from an Advanced Geosynchronous Platform (AGP)

Present technology allows radiometric monitoring of the Earth, ocean and atmosphere from a geosynchronous platform with good spatial, spectral and temporal resolution. The proposed system could provide a capability for multispectral remote sensing with a 50 m nadir spatial resolution in the visible bands, 250 m in the 4 micron band and 1 km in the 11 micron thermal infrared band. The diffraction limited telescope has a 1 m aperture, a 10 m focal length (with a shorter focal length in the infrared) and linear and area arrays of detectors. The diffraction limited resolution applies to scenes of any brightness but for a dark low contrast scenes, the good signal to noise ratio of the system contribute to the observation capability. The capabilities of the AGP system are assessed for quantitative observations of ocean scenes. Instrument and ground system configuration are presented and projected sensor capabilities are analyzed.

Maxwell, M. S.↗