Search NASA⌕ Search

SEARCH · Search NASA

Results for “Diffractometers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

On the possibility of placing a universal neutron diffractometer in an inclined channel of the PIK reactor

The possibility of placing a universal neutron diffractometer, which is designed for working with perfect crystals, in one of the inclined channels of the PIK reactor is discussed. It is proposed to use a double monochromator block (DMB) in the vertical plane and mounting crystals in the antiparallel position with reflection at a Bragg angle of 15 Degree-Sign . In this configuration, a set of well-known monochromator crystals (pyrolytic graphite, SiO{sub 2}, Si, Ge, Cu, and Pb) provides transmission bands of quasi-monochromatic neutrons in the range of 1-1.8 Angstrom-Sign . The angular and energy distributions of neutrons transmitted through the DMB are calculated. A scheme of the block for filtering radiations is proposed, and its parameters are calculated. The principles of instrument operation in a physical room (beyond the DMB) are determined.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Detector pixel calibration of time-of-flight neutron diffractometers accelerated by machine learning

Modern time-of-flight neutron diffractometers at spallation neutron source are equipped with two dimensional detectors with fine pixelations. The flight path of neutrons from the moderator to the sample and to the detector needs to be precisely calibrated at detector pixel level using standard powders so the diffraction data from all the detector pixels can be correctly time-focused to produce high resolution diffraction peaks. The number of pixels can reach to millions which makes a single-pixel calibration process time-consuming, or even impossible, with conventional fitting routine. Here we presented a machine learning aided calibration process via a “training and predict” process by training machine learning models with the relations between the individual pixel time-of-flight diffraction pattern and fitted diffraction constant. The training models take a portion of the available pixels to predict the diffraction constants precisely and rapidly for massive pixel diffraction patterns.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Position-Dependent Neutron Time-of-Flight Deviation at VULCAN Diffractometer

In neutron diffraction, it is critical to precisely measure the lattice spacing, as it is an indicator of a material’s physical characteristics, such as lattice strain, thermal expansion, and phase structures. In time-of-flight (TOF) measurements, the lattice spacing is determined by the recorded TOF from a well-calibrated instrument. However, changes in neutron time-of-flight are sensitive to many factors, such as the alignment of instrument optics, temperature, sample positions, sample dimensions, internal strains, and chemical or physical heterogeneities at the grain level. At VULCAN (SNS, ORNL), which is a high-flux engineering neutron diffractometer, we used a 1-mm-diameter diamond powder sample to scan for changes in TOF by measuring d-spacing values at different sample positions under several configurations. The 2D map of the TOF deviation or d-spacing deviation, in terms of lattice shift/lattice strain, is reported. The change in TOF is dependent on the scanned location in the beam as well as on detector locations. The results are informative for experimental planning, data interpretation, and future instrument design.

36 MATERIALS SCIENCE↗

Fast and Accurate Pixel Calibration of Tof Neutron Diffractometers with Machine Learning

At a spallation neutron source, neutron pulses of varying energies are generated, and the detection of neutrons by instrument detectors is recorded as time-of-flight from the emission of the neutron pulse to its arrival at specific detector pixels with high time resolution. The flight path of neutrons from the moderator to the sample and then to the detector must be precisely calibrated at the detector-pixel level using standard powders, so the neutron events from all pixels can be time-focused to produce high-resolution diffraction patterns. Modern time-of-flight neutron diffractometers at spallation neutron sources are equipped with two-dimensional detectors with millimeter-scale pixelations. The number of pixels in a diffraction instrument can reach millions, which makes a single-pixel-level calibration process time-consuming or even impossible with conventional refinement or fitting approaches. Here we present a machine-learning-aided calibration process using a train-and-predict approach, in which machine learning models are trained on the relationship between an individual pixel time-of-flight diffraction pattern and its diffraction constant. These models use a portion of the available pixels for training, and a good model then predicts the diffraction constants precisely and rapidly for large sets of pixel diffraction patterns.

detector pixel calibration↗

Neutron Optics Optimization for the SNS EQ-SANS Diffractometer

The extended Q-range small angle neutron scattering (EQ-SANS) diffractometer at the Spallation Neutron Source has recently been completed. Initial commissioning has shown that it has achieved its high intensity, low background, and wide dynamic range design goals. One of the key components that enable these performances is its neutron optics, which are extensively optimized using analytical and Monte Carlo methods. The EQ-SANS optics consist of a curved multichannel beam bender and sections of straight neutron guides on both ends of the bender. The bender and the guide are made of float glass coated with supermirror multilayers. The function of the optics is to ensure low instrument background by avoiding the direct line of sight of the neutron moderator at downstream locations, while transporting thermal and cold neutrons to the sample with maximum efficiency. In this work, the optimization of the EQ-SANS optics is presented.

Monte Carlo Simulations.↗

Design, implementation, and testing of a cryogenic loading capability on an engineering neutron diffractometer

A novel capability was designed, implemented, and tested for in situ neutron diffraction measurements during loading at cryogenic temperatures on the spectrometer for materials research at temperature and stress at Los Alamos National Laboratory. This capability allowed for the application of dynamic compressive forces of up to 250 kN on standard samples controlled at temperatures between 300 and 90 K. The approach comprised of cooling thermally isolated compression platens that in turn conductively cooled the sample in an aluminum vacuum chamber which was nominally transparent to the incident and diffracted neutrons. The cooling/heat rate and final temperature were controlled by regulating the flow of liquid nitrogen in channels inside the platens that were connected through bellows to the mechanical actuator of the load frame and by heaters placed on the platens. Various performance parameters of this system are reported here. The system was used to investigate deformation in Ni-Ti-Fe shape memory alloys at cryogenic temperatures and preliminary results are presented.

36 MATERIALS SCIENCE↗

Plasma ion source for in situ ion bombardment in a soft x-ray magnetic scattering diffractometer

A new plasma ion source for in situ keV He ion bombardment of solid state samples or thin films was designed and built for ion fluences between 1 x 10{sup 12} and 1 x 10{sup 17} ions/cm{sup 2}. The system was designed to be mounted to different diffraction chambers for soft x-ray resonant magnetic scattering. Without breaking the vacuum due to He-ion bombardment, structural and magnetic modifications of the samples can be studied in situ and element specifically.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a soft x-ray diffractometer for a wideband multilayer grating with a novel layer structure in the 2-4 keV range

We have been developing a wavelength-dispersive soft x-ray spectrograph covering an energy region of 50-4000 eV to attach to a conventional electron microscope. Observation of soft x-ray emission in the 2-4 keV range needs a multilayer coated grating. In order to evaluate the performance of the optical component in the energy region, a goniometric apparatus has been newly developed and the preliminary performance has been tested using synchrotron radiation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-energy x-ray diffractometer for nondestructive strain depth profile measurement

We describe a lab-based high-energy x-ray diffraction system and a new approach to nondestructively measuring strain profiles in polycrystalline samples. This technique utilizes the tungsten K{sub α1} characteristic radiation from a standard industrial x-ray tube. We introduce a simulation model that is used to determine strain values from data collected with this system. Examples of depth profiling are shown for shot peened aluminum and titanium samples. Profiles to 1 mm depth in aluminum and 300 μm depth in titanium with a depth resolution of 20 μm are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Electrochemical cell for in operando X-ray diffraction measurements on a conventional X-ray diffractometer

Electrochemical in operando X-ray diffraction (XRD) is a powerful method to analyze structural changes of energy storage materials while inserting/de-inserting charge carriers, such as Li- or Na-ions, into/from a host structure. The design of an XRD in operando cell is presented, which enables the use of thin (6 μm) aluminum foil as X-ray window as a non-toxic alternative to conventional beryllium windows. Owing to the reduced thickness, diffraction patterns and their changes during cycling can be observed with excellent quality, which was demonstrated for two cathode materials for sodium-ion batteries in a half-cell set-up, P2-Na{sub 0.7}MnO{sub 2} and Na{sub 2.55}V{sub 6}O{sub 16} ⋅ 0.6H{sub 2}O.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Initial testing of a Compact Crystal Positioning System for the TOPAZ Single-Crystal Diffractometer at the Spallation Neutron Source

A precise, versatile, and automated method of orienting a sub-millimeter crystal in a focused neutron beam is required for e cient operation of the TOPAZ Single Crystal Di ractometer at the Spallation Neutron Source at Oak Ridge National Laboratory. To ful ll this need, a Compact Crystal Positioning System (CCPS) has been developed in collaboration with Square One Systems Design in Jackson, Wyoming. The system incorporates a tripod design with six vacuum-compatible piezoelectric linear motors capable of < 1 m resolution. National Instruments LabVIEW provides a means of system automation while at the same time accommodating the modular nature of the SNS sample environment control software for straightforward system integration. Initial results in a cryogenic test environment will be presented, as well as results from ambient tests performed at the Advanced Photon Source at Argonne National Laboratory.

43 PARTICLE ACCELERATORS↗

Precise implications for real-space pair distribution function modeling of effects intrinsic to modern time-of-flight neutron diffractometers

Total scattering and pair distribution function (PDF) methods allow for detailed study of local atomic order and disorder, including materials for which Rietveld refinements are not traditionally possible (amorphous materials, liquids, glasses and nanoparticles). With the advent of modern neutron time-of-flight (TOF) instrumentation, total scattering studies are capable of producing PDFs with ranges upwards of 100–200 Å, covering the correlation length scales of interest for many materials under study. Despite this, the refinement and subsequent analysis of data are often limited by confounding factors that are not rigorously accounted for in conventional analysis programs. Furthermore, while many of these artifacts are known and recognized by experts in the field, their effects and any associated mitigation strategies largely exist as passed-down `tribal' knowledge in the community, and have not been concisely demonstrated and compared in a unified presentation. This article aims to explicitly demonstrate, through reviews of previous literature, simulated analysis and real-world case studies, the effects of resolution, binning, bounds, peak shape, peak asymmetry, inconsistent conversion of TOF to d spacing and merging of multiple banks in neutron TOF data as they directly relate to real-space PDF analysis. Suggestions for best practice in analysis of data from modern neutron TOF total scattering instruments when using conventional analysis programs are made, as well as recommendations for improved analysis methods and future instrument design.

36 MATERIALS SCIENCE↗