Search NASA⌕ Search

SEARCH · Search NASA

Results for “Digital Infrastructure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Digital Twinning and Predictive Modeling of Traffic for Safe, Efficient, and Reliable Intersections

Over the last decade, the advances in connected and autonomous vehicles (CAVs) have far surpassed the technological realm of transportation infrastructure. There is a growing need to have a technologically commensurate transportation infrastructure to enable safe and reliable movement of goods and people. The recent creation of Advanced Research Projects Agency - Infrastructure (ARPA-I) through the Infrastructure Investment and Jobs Act by the U.S. Department of Transportation (USDOT) has further amplified the need to revolutionize the transportation infrastructure system in the US. This need is perhaps felt most at traffic intersections, as more than 50 percent of the combined total of fatal and injury crashes occur at or near intersections. The proposed concept of Infrastructure Perception and Control (IPC) is aimed at bridging this technological gap by building a real-time digital twin of traffic by fusing detections from sensors installed at the intersection. This digital twin can then empower a wide variety of applications such as smart traffic signals or infrastructure-to-everything (I2X) communications. Smart signaling can help avoid crashes through early-prediction, while I2X can augment the CAV sensors under uncertain driving conditions and provide connected vehicles (CVs) with traffic information they can use to optimize their travel.

connected vehicles↗

Data Centers and Digital Assurance Workshop 3 – Mitigations for Digital Assurance Risks

The third session of the TADA (Technical Assistance for Digital Assurance) Data Centers Cohort, held on November 18, 2025, focused on developing mitigation strategies for digital assurance risks identified in previous workshops. Hosted by Idaho National Laboratory (INL) and ScottMadden, the session emphasized the application of Cyber-Informed Engineering (CIE) to data center infrastructure, particularly at the utility–data center interface. Participants revisited and ranked key digital assurance risks, including architecture and interface weaknesses, governance gaps, and AI-enabled threats. The workshop introduced the 12 principles of CIE, advocating for consequence-focused design, engineered controls, and secure information architecture to proactively reduce cyber-physical vulnerabilities. These principles were applied to critical data center systems such as power distribution, UPS, cooling, SCADA/BMS, and grid-forming batteries. The session also addressed governance challenges at the interconnection boundary, highlighting the need for clear roles in telemetry sharing, firmware management, and trip settings. Special attention was given to emerging risks from behind-the-meter (BTM) generation, including reverse-power flow and the integration of small modular reactors (SMRs), which shift data centers from large loads to complex generation nodes. Participants explored how interconnection agreements can serve as enforceable instruments for digital assurance, and reviewed gaps in current standards such as NERC CIP, IEC 62443, and IEEE 1547. The workshop concluded with pathways to standardization, including model agreement language, state-level programs, and expanded NERC guidance. INL also presented tools and frameworks for secure procurement and supplier risk management, reinforcing the need for integrated engineering and policy solutions to secure the evolving data center–grid ecosystem. Session 3 of 3.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

SULI End of Summer Presentation

This presentation made on Power Point is a brief summary of my work enhancing the Supervisory Control and Data Acquisition (SCADA) architecture for Idaho National Lab’s Critical Infrastructure Test Range Complex (CITRC). This work was part of an on-going project to create a digital twin of CITRC that will be implemented for resiliency research. Resiliency is growing more important as extreme weather, aging infrastructure, and increasing load all exert stress on the United States power grid. This presentation highlights how I documented the existing devices and data flow on site and then updated specific device settings to better support the needs of the project. It also examines future use of this data in the digital twin data warehouse (DeepLynx), and future Artificial Intelligence and Advanced Distribution Management System applications. It will be presented to the B751 Water and Energy Systems Analysis group at INL during my last week.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Latency Analysis of the Nexus Digital Twin Framework

Real-time digital catalogs are increasingly relied upon to track metadata and connect disparate data sources for cloud-based data integration efforts. One such tool, Deeplynx Nexus is supporting real-time digital twin efforts through event-driven data integration and time-series queries. Nexus’s usefulness for these applications depends critically on how quickly individual records can be uploaded and downloaded, since delays directly affect the responsiveness of any system built on top of it. However, the actual latency a user should expect from Nexus has not been systematically measured before, particularly for the small, frequent transactions typical of live sensor feeds. Here we show that single-record round-trip latency is 61.1 ms on a local Nexus instance and 391.7 ms on the hosted production infrastructure, a roughly 6.4x difference driven primarily by fixed per-request overhead rather than data volume. This overhead dominates at small scale: comparing single-record and ten-record trials suggests approximately 56 ms of each single-record request is fixed connection and authentication cost rather than data-transfer time, meaning batching even a handful of records is substantially more efficient than transmitting them individually. At large batch sizes, this pattern reverses for uploads, which converge to near parity between local and hosted environments by 25,000-50,000 records, while download latency remains persistently 5.7-6.4x slower on hosted infrastructure even at scale. These results suggest that Nexus deployments intended for real-time digital twin applications should prioritize record batching over single-record transactions, and that download-path optimization on hosted infrastructure offers the largest remaining opportunity to reduce latency at scale. We anticipate these baseline measurements will serve as a reference point for future digital twin projects evaluating whether Nexus’s latency profile meets their real-time requirements, and as a benchmark for tracking the effect of future infrastructure or API changes.

99 - GENERAL AND MISCELLANEOUS↗

Digital-Threat Bias and Psychological Distance: Barriers to Foundational Digital-Security Improvement

Modern life is held together by a web of digital dependencies that enable and provide delivery of critical services and functions—think the provision of utilities such as electricity and water, as well as our dependency on digital services for social and economic services (internet, communication, etc.). As this dependency grows, the complexity related to the delivery of these critical services increases as well. As complexity increases, the understanding of the risk and impact associated with potential disruption, degradation, or destruction—due to either malicious or non-malicious events of those digitally enabled functions—decreases. One potential explanation for the difficulty to 1) understand the risks faced and 2) address them appropriately and effectively is the abstractness and psychological distance assigned to “digital threat.” The complexity of these digitally enabled services creates a perceived complicatedness; as a result, digital threats are treated differently than similarly devasting (but more easily understood) kinetic or physical threats. How we categorize these threats also matters. Acts of cyber-enabled sabotage to critical infrastructure need to be defined as irregular warfare. By inadequately defining the threat, we compound the problem. Acknowledging this digital-threat bias is foundational to improving the ability to protect critical infrastructure. Using construal-level theory and psychological-distance concepts provides an intriguing starting point to address these issues, to reframe the challenges faced, and pursue more effective critical infrastructure security and defense policy.

29 - ENERGY PLANNING, POLICY AND ECONOMY↗

Communications Reliability for Vehicle Grid Integration

Electric Vehicles (EVs) adoption rate has been steadily increasing in the US leading to a growing number of charging stations including faster DC (Direct Current) chargers and slower Level 1 and Level 2 AC (Alternating Current) chargers. This increase in demand for electricity is further exacerbated by recent developments in Artificial Intelligence (AI) technology, advanced manufacturing, and digitization. These factors will require electric utilities to upgrade their infrastructure to keep up with the increasing electrical demand (especially during peak hours). An easy way to counteract the need for these upgrades is to shift a major chunk of active charge sessions (durations where there is energy transfer from charger to EV's propulsion battery) to off-peak hours thereby flattening the load curve and making the infrastructure more resilient. This concept is known as Smart Charge Management (SCM). EV owners also benefit from SCM since it lowers their charging costs and consequently their transportation costs by prioritizing charging during off-peak hours. SCM takes advantage of EV's capability to act as a controllable load or DER (Distributed Energy Resource). This report summarizes the reliability analysis performed on the communication required for two of these SCM use-cases. This analysis only focuses on SCM strategies for unidirectional charging (energy transfer from EVSE to EV or V1G) and not bidirectional charging.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Advanced Reactor Safeguards & Security Program: Cybersecurity Scenarios

The use of digital control systems and automation in advanced nuclear power systems introduces different types of vulnerabilities compared to legacy (i.e. analog) control systems that cyber adversaries can exploit. These vulnerabilities pose a challenge to reactor operators and cyber operations staff due to the dynamic nature of the event in which a human response or a lack of response can potentially evolve into a worsening plant condition. Using the Department of Homeland Security Cyber and Infrastructure Security Agency’s (CISA) critical infrastructure exercise framework, this document presents several cyber security scenarios typical of digital control systems that could be used in advanced reactor designs. These scenarios can be used in tabletop exercises to evaluate cyber security posture or conduct training on different aspects of cyber security, including detection, threat hunting using indicators of compromise, evaluating incident response, risk mitigation, incident reporting, information sharing and recovery.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

EVs-at-RISC: A Secure and Resilient Interoperable SCM Control System Architecture for Electric Vehicle’s-at-Scale (Final Technical Report)

The EVs-at-RISC project was a five-year research, development, and demonstration initiative to create foundational tools for utility-scale fleet aggregation and Smart Charge Management (SCM) of Electric Vehicles (EV), Electric Vehicle Charging Infrastructure (EVCI), and related Distributed Energy Resources (DER). Rather than seeking to develop and demonstrate highly perfected SCM algorithms and control strategies, this project instead focused on creating foundational software solutions that enable unprecedented digital interoperability across the communications technologies and vendor platforms used to manage EV , EVCI, and DER, as well as existing energy management infrastructure operated by utilities, grid operators, and aggregators. This project then extends these novel interoperability capabilities to develop and deploy powerful middleware abstractions across grid edge networks and EVCI/DER fleet aggregations incorporating modern software tools and best practices, such as CI/CD, to bring the immense capabilities of infrastructure-as-code and policy-as-code to modern grid edge network environments. This addresses the foremost systemic issues preventing realization of any net operational benefits from scaled deployment of behind-the-meter EV, EVCI, and DER assets in electric power grids and markets today. The results of this approach and project unlock massive potential for new SCM capabilities to be easily prototyped, evaluated, and deployed at-scale within the existing grid edge network infrastructure and EVCI/DER technology ecosystem. The EVs-at-RISC project achieves this by extending Open Field Message Bus (OpenFMB), a conceptual model for digital interoperability and distributed intelligence in traditional front-of-meter utility SCADA networks, validating our hypothesis that OpenFMB could be similarly used to solve systemic digital interoperability issues in behind-the-meter environments and unlock real-world utility-scale SCM capabilities without requiring any new proprietary vendor solutions or significant infrastructure reconfiguration.

24 POWER TRANSMISSION AND DISTRIBUTION↗

HPC Digital Twins for Evaluating Scheduling Policies, Incentive Structures and their Impact on Power and Cooling

Schedulers are critical for optimal resource utilization in high-performance computing. Traditional methods to evaluate sched- ulers are limited to post-deployment analysis, or simulators, which do not model associated infrastructure. In this work, we present the first-of-its-kind integration of scheduling and digital twins in HPC. This enables what-if studies to understand the impact of parameter configurations and scheduling decisions on the physical assets, even before deployment, or regarching changes not easily realizable in production. We (1) provide the first digital twin framework extended with scheduling capabilities, (2) integrate various top-tier HPC systems given their publicly available datasets, (3) implement extensions to integrate external scheduling simulators. Finally, we show how to (4) implement and evaluate incentive structures, as- well-as (5) evaluate machine learning based scheduling, in such novel digital-twin based meta-framework to prototype scheduling. Our work enables what-if scenarios of HPC systems to evaluate sustainability, and the impact on the simulated system.

Maiterth, Matthias [ORNL] (ORCID:000000018698460X)↗

From Vehicles to Systems: Understanding Freight Transportation as a Connected Energy, Infrastructure, and Operations System

The U.S. freight system may need to handle 50% more cargo by 2050. Upgrading our freight system requires modernizing capital-intensive, long-lived assets including freight trains, ports, and terminal infrastructure. NLR is advancing freight system solutions spanning ALTRIOS, the first digital twin for the full freight rail system; ALTRIOS-LIFTS, which can create digital twins of freight terminals; INFORMES, the first national model of the intermodal freight system; MARINESim, used to simulate and optimize ocean-going vessel operations; and more. These modeling and simulation tools enable data-driven decision-making across freight modes and systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Building a Trusted Roaming Hub [Slides]

The Trusted Roaming Hub is a U.S. Department of Energy-backed initiative led by the National Laboratory of the Rockies (NLR) to address one of the most persistent challenges in electric vehicle (EV) charging: fragmented roaming, inconsistent interoperability, and insufficient digital trust across charging networks. As EV adoption accelerates and charging infrastructure scales nationwide, today's many-to-many integration model between eMobility Service Providers (eMSPs) and Charge Point Operators (CPOs) has become increasingly brittle, costly, and difficult to secure. The Trusted Roaming Hub introduces a neutral, cybersecurity-forward "switchboard" architecture that enables standardized, secure, and scalable roaming interactions across the EV charging ecosystem. Rather than replacing existing networks or commercial relationships, the hub acts as a trusted intermediary that enforces consistent identity, authentication, authorization, and routing across participants improving reliability for drivers, lowering integration burden for industry, and creating a foundation for future grid-interactive charging services. This read-ahead provides an overview of the problem the hub is designed to solve, the core functional and security concepts behind the architecture, the value proposition to key stakeholders, and the near-term trajectory of the work.

33 ADVANCED PROPULSION SYSTEMS↗

Defense Resilience Technical Assistance Options - Initial Overview

The Defense Resilience Technical Assistance (TA) project, a collaboration between the DOE Grid Deployment Office and the DoD, aims to enhance energy infrastructure at military installations and utilities and the surrounding community. It focuses on improving energy system performance, addressing power infrastructure inadequacies, enhancing power quality, reducing cyber sabotage impacts, and strengthening digital supply chains. Defense Resilience Technical Assistance Options - Initial Overview. Intend to tailor to the pilot installation.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Cybersecurity Considerations for Hydrogen Infrastructure in Airport Environments

This report explores key cybersecurity concerns and best practices within environments that serve as reference points for the development of hydrogen fueling infrastructure for aviation. This cybersecurity analysis leverages prior NREL studies: 1) hydrogen fueling station component validation to identify vulnerabilities and failure events documented in physical equipment, and 2) electric aircraft charging infrastructure analysis to explore primary cybersecurity vulnerabilities. It reviews the criticality of digitized technologies in sustaining hydrogen fuel production, storage, and fueling systems, noting cybersecurity concerns that are universal to power systems and industrial control systems in general. In considering cybersecurity vulnerabilities within a future landscape of hydrogen energy for aviation applications, a reference architecture was intended to reveal the points of connection between assets and the potential sensors that are vulnerable to manipulation in the event of compromised access or communication within a SCADA system. A generalized reference architecture can help stakeholders, engineers, or strategists understand connections, criticalities, and standard practices when it comes to designing and planning for new systems. There are several gaps to account for in assessing the future of hydrogen production, storage, and fueling for aviation. Engaging stakeholders, including aircraft manufacturers, electric utilities, site property owners, and local communities, will inform decision-making around site structure, operations, and resources for future hydrogen fueling infrastructure to understand operational needs and cybersecurity awareness. Cybersecurity mitigation strategy must consider physical attack vectors that emerge with the integration of hydrogen systems into existing airport security requirements. The cybersecurity risk assessment contained in this report is an entry point into potential future granular-level analyses to be conducted as part of hazard and risk assessments for safe aviation hydrogen infrastructure, determining how the scale of hydrogen fuel infrastructure for aviation impacts the volume of cyber attack vectors, and what, if any, are the vulnerabilities associated with different types of on-board hydrogen systems. In this nascent development phase, assessing how best to integrate cybersecurity practices into an evolving U.S. aviation landscape provides critical insights into building increased awareness and stakeholder engagement to support a cyber-resilient infrastructure.

08 HYDROGEN↗

Cybersecurity Enhancement in Digital Substations: Hidden Markov Model-Based Smart Cyber Switching and Threat Response

The rising incidence of cyber-attacks on critical infrastructure and power grids poses significant threats to the stability and reliability of electrical substations, with potentially devastating consequences such as extended blackouts. This paper introduces an advanced cybersecurity framework aimed at safeguarding IEC 61850-based substations through the integration of software-defined networking (SDN) and digital twin (DT) technologies. The proposed DT-based framework employs smart cyber switching (SCS) for proactive threat mitigation and concurrent intelligent electronic device (CIED) for swift system restoration, thereby maintaining continuous operational integrity and robust cybersecurity defenses. Central to this framework is the adaptive port controller (APC), which enables dynamic port management to adapt to evolving threats, and an intrusion detection system (IDS) designed to detect and neutralize malicious attacks on IEC 61850-based sampled value (SV) and generic object-oriented substation event (GOOSE) messages within the substation’s communication network. Further, novel predictive intrusion detection and response (PIDR) algorithm is implemented on a digital substation (DS) to predict the best route to be taken by the attacker. The efficacy of these comprehensive cybersecurity frameworks is validated through rigorous simulations and a hardware-in-the-loop (HIL) testbed, showcasing the system’s ability to sustain substation operations amidst cyber-attacks.

Digital substation↗

Roadmap for Solar Photovoltaic (PV) Cybersecurity: A vision for improving cyber maturity of distributed and utility-scale solar energy installations

As the solar energy sector continues to expand, its integration into the broader energy infrastructure presents both unprecedented opportunities and new risks. The increasing reliance on digital technologies and interconnected systems in solar energy creates an expanded attack surface for motivated cyber adversaries. Cyberattacks have the potential to cause disruptions in energy production, damage to equipment, financial losses, and compromises in national security. Therefore, ensuring robust cybersecurity measures is paramount to protect the integrity, availability, confidentiality, and access control of solar energy systems. However, there are still key gaps and challenges to be addressed in industry and research, which stakeholders must race to address as they combat a growing number of real-world cyber incidents that affect solar energy systems and a growing number of vulnerabilities discovered and disclosed in key types of equipment. This roadmap explore the current state of solar PV cybersecurity and the gaps and challenges still to be addressed.

14 - SOLAR ENERGY↗

Advanced Transmission Technologies – GETs and HPCs Session 2: Advanced Power Flow Control and Transmission Topology Optimization

The INL TADA GETs Cohort Session 2, held on November 7, 2025, conducted in collaboration with ScottMadden, focused on two core Advanced Transmission Technologies (ATTs): Advanced Power Flow Control (APFC) and Transmission Topology Optimization (TTO). These technologies are pivotal in enhancing grid flexibility, reliability, and cybersecurity resilience. APFC, particularly through modular FACTS devices like Modular Static Synchronous Series Compensators (M-SSSCs), enables dynamic voltage injection to reroute power flows. The session highlighted the deployment benefits of APFC, such as rapid installation, minimal civil works, and re-deployability. Regulatory drivers like FERC Order 2023 mandate the inclusion of Grid-Enhancing Technologies (GETs) in interconnection studies. Case studies from Central Hudson, CAISO, and National Grid (UK) demonstrated APFC’s effectiveness in congestion relief and cost savings. The session also addressed cybersecurity concerns, including firmware vulnerabilities, SCADA integration risks, and supply chain dependencies. Participants engaged in interactive exercises to rank cybersecurity and supply chain risks, emphasizing the need for robust digital assurance strategies. TTO involves software-based reconfiguration of transmission networks to optimize power flow without new infrastructure. The session showcased its operational value, with examples from SPP, PJM, and MISO showing significant congestion cost reductions. Cybersecurity vulnerabilities were discussed, particularly in API security and software supply chains, referencing incidents like SolarWinds and attacks on Danish utilities. Digital assurance exercises explored worst-case scenarios, attack paths, and mitigation responsibilities between vendors and utilities. Reliability challenges such as algorithm stability, vendor dependency, and operator trust were also examined. Cross-cutting themes emphasized the importance of digital assurance tools, including Software Bills of Materials (SBOMs) and hardware-in-loop testing. Human performance, training, and operational confidence were identified as critical enablers of technology adoption. The session concluded with a preview of Session 3, which will focus on High Performance Conductors (HPCs) and risk-based cybersecurity tools. Session 2 of 3.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Resilient information and inference networks under mixed-trust sensing

With ubiquitous digitization, sensing, and computational intelligence deployed in increasingly more and broader domains, including critical infrastructure, potentially misleading and destabilizing effects of multimodal anomalies and adversarial behavior are growing in importance. Here, we develop randomized and reinforcement learning-based strategies for strategically recruiting and utilizing deployed (and, thus, vulnerable and potentially faulty and/or compromised) nodes from information and inference networks, while defending against adversaries that attempt to misguide assessments of inferred variables. Recognizing that, besides communication and other costs, sampling from any observable node can either provide true data or dangerously expose our inference to misinformation (without being easily distinguishable what actually happens), the proposed strategies proceed by progressively recruiting nodes and cautiously scaling their information contribution based on assumed, or, in our reinforcement learning approach, intelligently weighed trustworthiness, with the learning approach also considering network-wide, threat-inclusive risk/value tradeoffs. While avoiding the hardware, communication, analytical and computational burden of explicit redundancy, the proposed defensive schemes enable on-the-fly assessments of underlying processes, and system-wide situational awareness with demonstrable resilience against adversarial activities.

97 - MATHEMATICS AND COMPUTING↗

DeepLynx Ecosystem 2025

Poor data integration and governance continue to plague complex engineering projects, resulting in missed cost, schedule, and performance targets. Departments operate in isolated systems with manual data exchange, creating fragmented information that compounds errors and leads to significant delays and cost overruns. The DeepLynx ecosystem addresses these challenges through an open-source, modular data management platform that transforms fragmented project data into an integrated digital thread. Built on a federated microservice architecture, the ecosystem comprises seven specialized tools centered around DeepLynx Nexus, a unified data catalog with hierarchical organization and graph-based navigation capabilities. The ecosystem includes: DeepLynx Stream for real-time timeseries data ingestion from industrial sources; DeepLynx Ingest for governed data uploads with formal review workflows; DeepLynx Lattice for ontology-based entity and relationship extraction; DeepLynx Run for workflow orchestration and secure AI/ML compute; DeepLynx Visualize for 3D digital twin visualization; and DeepLynx Insight for AI-assisted document analysis with traceable, grounded responses. Deployable in cloud, on-premise, or hybrid environments using containerized Docker applications and Helm charts, the DeepLynx ecosystem provides flexible infrastructure that adapts to organizational requirements. By consolidating project data into a unified data lake with role-based access controls and OAuth2 authentication, DeepLynx enables digital thread and digital twin capabilities that improve decision-making, reduce risk, and support complex engineering workflows throughout the project lifecycle.

42 - ENGINEERING↗