Search NASA⌕ Search

SEARCH · Search NASA

Results for “Digital spectrometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Preprocessing of multispectral data and simulation of ERTS data channels to make computer terrain maps of a Yellowstone National Park test site

The possibility of improving the accuracy of terrain classification by preprocessing spectral data was investigated. Terrain maps were made using the following techniques: 1) preprocessing by scan angle function transformation, using the computer-selected best set of three channels; and 2) preprocessing by ratio transformation, using the specified ERTS data channels, simulated by fitting the spectral response of each of the 12 data channels to the ERTS channels by a set of weighting coefficients. By using a simple technique during printout, the maps were produced in color. The normalized scan angle function transformation resulted in the most accurate classification. The best ratio transformation for the Yellowstone Park data was the ratio of each channel to the sum of all channels. A supervised training program involving maximum likelihood decision for selecting the best spectrometer channels and similar techniques for digitizing the data of the analog magnetic tapes were used. Cloud shadows were recognized in addition to eight classes of terrain. Preprocessing of data resulted in more accurate maps, required fewer training areas (hence less preparation and computer time), and enabled much of the area formerly classified as shadow to be reclassified according to actual terrain type.

Smedes, H. W.↗

Use of the single-breath method of estimating cardiac output during exercise-stress testing.

The single-breath cardiac output measurement technique of Kim et al. (1966) has been modified for use in obtaining cardiac output measurements during exercise-stress tests on Apollo astronauts. The modifications involve the use of a respiratory mass spectrometer for data acquisition and a digital computer program for data analysis. The variation of the modified method for triplicate steady-state cardiac output measurements was plus or minus 1 liter/min. The combined physiological and methodological variation seen during a set of three exercise tests on a series of subjects was 1 to 2.5 liter/min. Comparison of the modified method with the direct Fick technique showed that although the single-breath values were consistently low, the scatter of data was small and the correlation between the two methods was high. Possible reasons for the low single-breath cardiac output values are discussed.

Buderer, M. C.↗

A new high-speed solar radio spectrograph for meter and decameter wavelengths

The design and characteristics of a high resolution, digital solar spectrograph are discussed. The spectrometer operates in the 10 to 80 MHz range. The primary considerations in the design of the spectrograph were: (1) optimun sensitivity, (2) wide dynamic range, (3) flexibility in time and frequency resolution, and (4) modern data handling techniques with a simple computer interface.

Mosier, S. R.↗

An autoranging scanning system and compatible methods of noise reduction

The autoranging scanning system discussed combines in a unique way four different methods for removing noise. The system employs a narrow-band amplifier. Other noise reduction methods make use of digital summation, convolution numbers, and the coaddition of scans. The system was designed to digitize the output of an infrared spectrometer and to record it on magnetic tape. Light passes through a mechanical light chopper and the spectrometer optics, and falls on the PbS cell to produce a signal which is amplified by the first preamplifier.

Saufley, D. C.↗

Atomic emission spectroscopy

The relationship between the Slater-Condon theory and the conditions within the atom as revealed by experimental data was investigated. The first spectrum of Si, Rb, Cl, Br, I, Ne, Ar, and Xe-136 and the second spectrum of As, Cu, and P were determined. Methods for assessing the phase stability of fringe counting interferometers and the design of an autoranging scanning system for digitizing the output of an infrared spectrometer and recording it on magnetic tape are described.

Andrew, K. H.↗

Automated SEM Modal Analysis Applied to the Diogenites

Analysis of volume proportions of minerals, or modal analysis, is routinely accomplished by point counting on an optical microscope, but the process, particularly on brecciated samples such as the diogenite meteorites, is tedious and prone to error by misidentification of very small fragments, which may make up a significant volume of the sample. Precise volume percentage data can be gathered on a scanning electron microscope (SEM) utilizing digital imaging and an energy dispersive spectrometer (EDS). This form of automated phase analysis reduces error, and at the same time provides more information than could be gathered using simple point counting alone, such as particle morphology statistics and chemical analyses. We have previously studied major, minor, and trace-element chemistry of orthopyroxene from a suite of diogenites. This abstract describes the method applied to determine the modes on this same suite of meteorites and the results of that research. The modal abundances thus determined add additional information on the petrogenesis of the diogenites. In addition, low-abundance phases such as spinels were located for further analysis by this method.

Bowman, L. E.↗

Benchtop Detection of Proteins

A process, and a benchtop-scale apparatus for implementing the process, have been developed to detect proteins associated with specific microbes in water. The process and apparatus may also be useful for detection of proteins in other, more complex liquids. There may be numerous potential applications, including monitoring lakes and streams for contamination, testing of blood and other bodily fluids in medical laboratories, and testing for microbial contamination of liquids in restaurants and industrial food-processing facilities. A sample can be prepared and analyzed by use of this process and apparatus within minutes, whereas an equivalent analysis performed by use of other processes and equipment can often take hours to days. The process begins with the conjugation of near-infrared-fluorescent dyes to antibodies that are specific to a particular protein. Initially, the research has focused on using near-infrared dyes to detect antigens or associated proteins in solution, which has proven successful vs. microbial cells, and streamlining the technique in use for surface protein detection on microbes would theoretically render similar results. However, it is noted that additional work is needed to transition protein-based techniques to microbial cell detection. Consequently, multiple such dye/antibody pairs could be prepared to enable detection of multiple selected microbial species, using a different dye for each species. When excited by near-infrared light of a suitable wavelength, each dye fluoresces at a unique longer wavelength that differs from those of the other dyes, enabling discrimination among the various species. In initial tests, the dye/antibody pairs are mixed into a solution suspected of containing the selected proteins, causing the binding of the dye/antibody pairs to such suspect proteins that may be present. The solution is then run through a microcentrifuge that includes a membrane that acts as a filter in that it retains the dye/antibody/protein complexes while allowing any remaining unbound dye/antibody pairs to flow away. The retained dye/antibody/protein complexes are transferred to a cuvette, wherein they are irradiated with light from a miniature near-infrared laser delivered via a fiber-optic cable. The resulting fluorescence from the dye(s) is measured by use of a miniature spectrometer, the output of which is digitized, then analyzed by laptop computer. The software running in the computer identifies the protein species by the wavelengths of their spectral peaks and determines the amounts of the proteins, and thus, one day, microbes of the various species from the intensities of the peaks. The abovementioned removal of the unbound dye/antibody pairs during centrifugation prevents false positive readings. The process proves successful in detecting proteins in solution and thus can now be employed for use in microbe detection.

Scardelletti, Maximilian C.↗

Progress in the Scandia Region Geologic Map of Mars

We are in the second year of a four year project to produce a geologic map of the Scandia region of Mars at 1:3,000,000 scale for publication in the USGS Scientific Investigations Map series. The primary objective of the map is to analyze and reconstruct the resurfacing history of this region in much greater detail than achieved by the previous northern plainswide mapping effort. This region includes (1) a broad swath of the Vastitas Borealis plains that includes various Scandia landforms and the Phoenix lander site; (2) part of the margin of the north polar plateau, Planum Boreum; and (3) the northern margin of the immense Alba Mons volcanic shield. We rely mostly on Mars Orbiter Laser Altimeter (MOLA) digital elevation models, Thermal Emission Imaging Spectrometer infrared and visual range, and Context Camera images for mapping and topographic analysis.

Tanaka, K. L.↗

Adaptive Wavelength Scanning Lidar (AWSL) for 3D Mapping from Space

We present the design and performance of an adaptive wavelength scanning lidar (AWSL) for highly efficient mapping from low Earth orbit (LEO). Mapping is accomplished by steering a laser beam across 1,200 resolvable spots using wavelength tuning and grating dispersion. Any subset of these 1,200 spots can be selected by wavelength switching. The design is validated with an 1550-nm prototype using a fast wavelength-tuned (500-kHz) pulsed (2-ns) fiber laser with the beam dispersed by gratings for beam steering. Reflected pulses are detected with an eight-pixel detector array with single-photon sensitivity. Eight lidar returns are time-multiplexed to one output that is digitized with a single 1-GSPS-digitizer, to save power. A grating spectrometer rejects solar background noise spatially and spectrally, and images laser footprints on to the detector array. The gratings retain the fiber laser beam quality. We are developing a 1030-nm AWSL intended for a LEO SmallSat platform.

Guangning Yang↗

Synopsis of a computer program designed to interface a personal computer with the fast data acquisition system of a time-of-flight mass spectrometer

Briefly described are the essential features of a computer program designed to interface a personal computer with the fast, digital data acquisition system of a time-of-flight mass spectrometer. The instrumentation was developed to provide a time-resolved analysis of individual vapor pulses produced by the incidence of a pulsed laser beam on an ablative material. The high repetition rate spectrometer coupled to a fast transient recorder captures complete mass spectra every 20 to 35 microsecs, thereby providing the time resolution needed for the study of this sort of transient event. The program enables the computer to record the large amount of data generated by the system in short time intervals, and it provides the operator the immediate option of presenting the spectral data in several different formats. Furthermore, the system does this with a high degree of automation, including the tasks of mass labeling the spectra and logging pertinent instrumental parameters.

Bechtel, R. D.↗

Science data systems

Digital generation of acceleration voltage for mass spectrometer, and development of low power, nondestructive readout, plated-wire memory

Source record↗

Fast Data Acquisition For Mass Spectrometer

New equipment has speed and capacity to process time-of-flight data. System relies on fast, compact waveform digitizer with 32-k memory coupled to personal computer. With digitizer, system captures all mass peaks on each 25- to 35-microseconds cycle of spectrometer.

Lincoln, K. A.↗

Portable instant display and analysis reflectance spectrometer

A portable analysis spectrometer (10) for field mineral identification is coupled to a microprocessor (11) and memory (12) through a bus (13) and A/D converter (14) to display (16) a spectrum of reflected radiation in a band selected by an adjustable band spectrometer (20) and filter (23). A detector array (21) provides output signals at spaced frequencies within the selected spectrometer band which are simultaneously converted to digital form for display. The spectrum displayed is compared with a collection of spectra for known minerals. That collection is stored in memory and selectively displayed with the measured spectrum, or stored in a separate portfolio. In either case, visual comparison is made. Alternatively, the microprocessor may use an algorithm to make the comparisons in search for the best match of the measured spectrum with one of the stored spectra to identify the mineral in the target area.

Goetz, Alexander F. H.↗

Compact Imaging Spectrometer for Planetary Missions

We report on the design performance of a compact imaging spectrometer suitable for planetary missions with U-Class spacecraft. It is a fast (F/1.9) and wide field instrument covering the range 600-3600 nm with 10 nm sampling and a 1000 pixel by 18m wide slit. The spectrometer is designed for use with a digital readout focal plane array that further aids miniaturization.

Lin, Myrtle F.↗

Optical spectrum of HDE 245770 /A0535 + 26/

Narrow-band spectrophotometric observations of HDE 245770 with the multichannel spectrometer and slit spectra obtained with the SIT digital spectrograph at the Cassegrain focus of the 5-m Hale telescope indicate that this star is of spectral type B0 with emission at H-alpha, H-beta, and probably 5876 A of He I. There is some evidence that it is of luminosity class III. The reddening is estimated in various ways and corresponds to a B-V color excess of 0.80. If the star is really a giant, its distance is approximately 1.8 kpc. No variations larger than 1% at the reported 104-x X-ray pulse period are evident in the data in visual magnitude, color, or H-alpha emission intensity. This is not surprising, since the optical star is much more luminous than the X-ray object, and the heating effect of the X-ray source (which is assumed to be one component of a binary) on the B0 star's atmosphere can produce at most a few percent modulation in visual light.

Wade, R. A.↗

Digital Signal Processing Techniques for the GIFTS SM EDU

The Geosynchronous Imaging Fourier Transform Spectrometer (GIFTS) Sensor Module (SM) Engineering Demonstration Unit (EDU) is a high resolution spectral imager designed to measure infrared (IR) radiance using a Fourier transform spectrometer (FTS). The GIFTS instrument employs three Focal Plane Arrays (FPAs), which gather measurements across the long-wave IR (LWIR), short/mid-wave IR (SMWIR), and visible spectral bands. The raw interferogram measurements are radiometrically and spectrally calibrated to produce radiance spectra, which are further processed to obtain atmospheric profiles via retrieval algorithms. This paper describes several digital signal processing (DSP) techniques involved in the development of the calibration model. In the first stage, the measured raw interferograms must undergo a series of processing steps that include filtering, decimation, and detector nonlinearity correction. The digital filtering is achieved by employing a linear-phase even-length FIR complex filter that is designed based on the optimum equiripple criteria. Next, the detector nonlinearity effect is compensated for using a set of pre-determined detector response characteristics. In the next stage, a phase correction algorithm is applied to the decimated interferograms. This is accomplished by first estimating the phase function from the spectral phase response of the windowed interferogram, and then correcting the entire interferogram based on the estimated phase function. In the calibration stage, we first compute the spectral responsivity based on the previous results and the ideal Planck blackbody spectra at the given temperatures, from which, the calibrated ambient blackbody (ABB), hot blackbody (HBB), and scene spectra can be obtained. In the post-calibration stage, we estimate the Noise Equivalent Spectral Radiance (NESR) from the calibrated ABB and HBB spectra. The NESR is generally considered as a measure of the instrument noise performance, and can be estimated as the standard deviation of calibrated radiance spectra from multiple scans. To obtain an estimate of the FPA performance, we developed an efficient method of generating pixel performance assessments. In addition, a random pixel selection scheme is developed based on the pixel performance evaluation. This would allow us to perform the calibration procedures on a random pixel population that is a good statistical representation of the entire FPA. The design and implementation of each individual component will be discussed in details.

Tian, Jialin↗

A high-speed digital camera system for the observation of rapid H-alpha fluctuations in solar flares

Researchers developed a prototype digital camera system for obtaining H-alpha images of solar flares with 0.1 s time resolution. They intend to operate this system in conjunction with SMM's Hard X Ray Burst Spectrometer, with x ray instruments which will be available on the Gamma Ray Observatory and eventually with the Gamma Ray Imaging Device (GRID), and with the High Resolution Gamma-Ray and Hard X Ray Spectrometer (HIREGS) which are being developed for the Max '91 program. The digital camera has recently proven to be successful as a one camera system operating in the blue wing of H-alpha during the first Max '91 campaign. Construction and procurement of a second and possibly a third camera for simultaneous observations at other wavelengths are underway as are analyses of the campaign data.

Kiplinger, Alan L.↗