Search NASA⌕ Search

SEARCH · Search NASA

Results for “Dilatancy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Periodically correlated processes and their stationary dilations

An explicit form for a stationary dilation for periodically correlated random processes is obtained. This is then used to give spectral conditions for a periodically correlated process to be non-deterministic, purely deterministic, minimal, and to have a positive angle between its past and future.

Miamee, A. G.↗

Is there cosmological time dilation in gamma-ray bursts?

Norris et al. report that the temporal structure of faint gamma-ray bursts is longer than that of bright bursts, as expected for time dilation in the cosmological models of burst origin. I show that the observed trends can easily be produced by a burst luminosity function and thus may not result from cosmological effects. A cosmological signature may be present, but the tests Norris et al. present are not powerful enough to detect these signatures.

Band, David L.↗

On the nature of gamma-ray burst time dilations

The recent discovery that faint gamma-ray bursts are stretched in time relative to bright ones has been interpreted as support for cosmological distances: faint bursts have their durations redshifted relative to bright ones. It was pointed out, however, that the relative time stretching can also be produced by an intrinsic correlation bewteen duration and luminosity of gamma-ray bursts in a nearby, bounded distribution. While both models can explain the average amount of time stretching, we find a difference between them in the way the duration distribution of faint bursts deviates from that of bright ones, assuming the luminosity function of gamma-ray bursts is independent of distance. This allows us to distinguish between these two broad classes of model on the basis of the duration distributions of gamma-ray bursts, leading perhaps to an unambiguous determination of the distance scale of gamma-ray bursts. We apply our proposed test to the second Burst and Transient Source Experiment (BATSE) catalog and conclude, with some caution, that the data favor a cosmological interpretation of the time dilation.

Wijers, Ralph A. M. J.↗

An Assessment of the Axial and Radial Dilation of a DPIMS Tantalum Cartridge for Space Shuttle Flight Experiments

Ground-based heat treatment tests are planned on an argon gas-filled tantalum cartridge developed as pan of a Diffusion Processes in Molten Semiconductors (DPIMS) experiment conducted on NASA's Space Shuttle. The possibility that the cartridge may creep during testing and touch the furnace walls is of real concern in this program. The present paper discusses the results of calculations performed to evaluate this possibility. Deformation mechanism maps were constructed using literature data in order to identify the creep mechanism dominant under the appropriate stresses and temperatures corresponding to the test conditions. These results showed that power-law creep was dominant when the grain size of the material exceeded 55 gm but Coble creep was the important mechanism below this value of grain size. Finite element analysis was used to analyze the heat treatment tWs assuming a furnace run away condition (which is a worst case scenario) using the appropriate creep parameters corresponding to grain sizes of 1 and 100 gm. Calculations were also conducted to simulate the effect of an initial 3 tilt of the cartridge assembly, the maximum possible tilt angle. The von Mises stress and su-ain distributions were calculated assuming that the cartridge was fixed at one end as it was heated from ambient temperature to 1823 K in 1.42 h, maintained at 1823 K for 9.5 h and then further heated to an over temperature condition of 2028 K in 0.3 h. The inelastic axial and radial displacements of the cartridge walls were evaluated by resolving the von Mises strain along the corresponding directions. These calculations reveal that the maximum axial and radial displacements are expected to be about 2.9 and 0.25 mm, respectively, for both fine and coarse-grained materials at 2028 K. It was determined that these displacements occur during heat-up to temperature and creep of the cartridge is likely to be relatively insignificant irrespective of grain size. Furthermore, with a 3' tilt of the cartridge, the deflection is increased by only 0.39 gm which is negligible. Since the gap between the furnace heating elements and the cartridge is about 7.5 mm and less than the maximum radial dilation of 0.25 mm at 2028 K, it is concluded that the cartridge is unlikely to touch the furnace walls during the experiments.

Raj, S.V.↗

Usefulness of microvolt T-wave alternans for prediction of ventricular tachyarrhythmic events in patients with dilated cardiomyopathy: results from a prospective observational study

OBJECTIVES: This study was designed to evaluate the ability of microvolt-level T-wave alternans (MTWA) to identify prospectively patients with idiopathic dilated cardiomyopathy (DCM) at risk of ventricular tachyarrhythmic events and to compare its predictive accuracy with that of conventional risk stratifiers. BACKGROUND: Patients with DCM are at increased risk of sudden death from ventricular tachyarrhythmias. At present, there are no established methods of assessing this risk. METHODS: A total of 137 patients with DCM underwent risk stratification through assessment of MTWA, left ventricular ejection fraction, baroreflex sensitivity (BRS), heart rate variability, presence of nonsustained ventricular tachycardia (VT), signal-averaged electrocardiogram, and presence of intraventricular conduction defect. The study end point was either sudden death, resuscitated ventricular fibrillation, or documented hemodynamically unstable VT. RESULTS: During an average follow-up of 14 +/- 6 months, MTWA and BRS were significant univariate predictors of ventricular tachyarrhythmic events (p < 0.035 and p < 0.015, respectively). Multivariate Cox regression analysis revealed that only MTWA was a significant predictor. CONCLUSIONS: Microvolt-level T-wave alternans is a powerful independent predictor of ventricular tachyarrhythmic events in patients with DCM.

Evaluation Studies↗

Geometric differences of the mitral apparatus between ischemic and dilated cardiomyopathy with significant mitral regurgitation: real-time three-dimensional echocardiography study

BACKGROUND: This study was conducted to elucidate the geometric differences of the mitral apparatus in patients with significant mitral regurgitation caused by ischemic cardiomyopathy (ICM-MR) and by idiopathic dilated cardiomyopathy (DCM-MR) by use of real-time 3D echocardiography (RT3DE). METHODS AND RESULTS: Twenty-six patients with ICM-MR caused by posterior infarction, 18 patients with DCM-MR, and 8 control subjects were studied. With the 3D software, commissure-commissure plane and 3 perpendicular anteroposterior (AP) planes were generated for imaging the medial, central, and lateral sides of the mitral valve (MV) during mid systole. In 3 AP planes, the angles between the annular plane and each leaflet (anterior, Aalpha; posterior, Palpha) were measured. In ICM-MR, Aalpha measured in the medial and central planes was significantly larger than that in the lateral plane (39+/-5 degrees, 34+/-6 degrees, and 27+/-5 degrees, respectively; P<0.01), whereas Palpha showed no significant difference in any of the 3 AP planes (61+/-7 degrees, 57+/-7 degrees, and 56+/-7 degrees, P>0.05). In DCM-MR, both Aalpha (38+/-8 degrees, 37+/-9 degrees, and 36+/-7 degrees, P>0.05) and Palpha (59+/-6 degrees, 58+/-5 degrees, and 57+/-6 degrees, P>0.05) revealed no significant differences in the 3 planes. CONCLUSIONS: The pattern of MV deformation from the medial to the lateral side was asymmetrical in ICM-MR, whereas it was symmetrical in DCM-MR. RT3DE is a helpful tool for differentiating the geometry of the mitral apparatus between these 2 different types of functional mitral regurgitation.

Evaluation Studies↗

Initial clinical experience of real-time three-dimensional echocardiography in patients with ischemic and idiopathic dilated cardiomyopathy

The geometry of the left ventricle in patients with cardiomyopathy is often sub-optimal for 2-dimensional ultrasound when assessing left ventricular (LV) function and localized abnormalities such as a ventricular aneurysm. The aim of this study was to report the initial experience of real-time 3-D echocardiography for evaluating patients with cardiomyopathy. A total of 34 patients were evaluated with the real-time 3D method in the operating room (n = 15) and in the echocardiographic laboratory (n = 19). Thirteen of 28 patients with cardiomyopathy and 6 other subjects with normal LV function were evaluated by both real-time 3-D echocardiography and magnetic resonance imaging (MRI) for obtaining LV volumes and ejection fractions for comparison. There were close relations and agreements for LV volumes (r = 0.98, p <0.0001, mean difference = -15 +/- 81 ml) and ejection fractions (r = 0.97, p <0.0001, mean difference = 0.001 +/- 0.04) between the real-time 3D method and MRI when 3 cardiomyopathy cases with marked LV dilatation (LV end-diastolic volume >450 ml by MRI) were excluded. In these 3 patients, 3D echocardiography significantly underestimated the LV volumes due to difficulties with imaging the entire LV in a 60 degrees x 60 degrees pyramidal volume. The new real-time 3D echocardiography is feasible in patients with cardiomyopathy and may provide a faster and lower cost alternative to MRI for evaluating cardiac function in patients.

NASA Discipline Cardiopulmonary↗

Investigation of the aerodynamic noise generating region of a jet engine by means of the simple source fluid dilatation model

An experiment was conducted on a full-scale jet engine to investigate the aerodynamic noise generating regions in the free jet. Cross-correlation measurements were made between the static pressure fluctuations and the farfield radiated sound. These measurements were made for two different static pressure probe positions and a large number of farfield positions (at various angles). In addition, each test geometry was run for four different jet exit velocities. The measured, normalized cross-correlation functions varied between 0.004 and 0.155. A new Q-function, based on the above normalized cross correlation is defined and plotted. This function represents the source strength per unit volume within the jet region. This Q-function shows dependence on the probe position, the angular position of the farfield microphone, and the jet exit Mach number. Third-octave analyses of both the probe signal and the farfield radiated sound were made. The results show that cross-correlation techniques are a valuable tool in the investigation of the aerodynamic noise generating regions of an actual jet engine.

Hurdle, P. M.↗