Search NASA⌕ Search

SEARCH · Search NASA

Results for “Display Failure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

63 records · Page 4

Electrochemical performance of ionic polymer metal composite under tensile loading

Abstract Cracks in polymer composites can lead to premature failure, which can be disastrous for polymer-based energy storage devices. Detecting these cracks is essential to guarantee the reliability and safety of such devices. However, detecting cracks in composite polymers such as ionic polymer metal composites (IPMCs) is a challenging task, which makes it difficult to ensure their performance and safety. The overall goal of this study is to investigate the effect of cracks or damage caused by tensile loading on the mechanical properties and electrochemical characteristics of IPMC based capacitors. During tensile testing, the deformation of the IPMC strips causes changes in the ion distribution and concentration in the polymer matrix, influencing the performance of the material. The measurements were conducted utilizing electrochemical impedance spectroscopy at a room temperature ( 21 ∘ C ) and frequency range of 10 KHz to 1 Hz. The method utilized in this study proved to be easy and quick with consistent results. The IPMC capacitor was found to increase its capacitance after major cracking in the Pt electrodes from high tensile mechanical loads. Furthermore, at lower frequency range (<100 Hz), the real ( ε ′ ) and imaginary ( ε ′ ′ ) part of permittivity increase with the addition of loads. This displays that the dielectric property of the material is affected due to the increasing of the loads. It is concluded that, at frequencies above 100 Hz, the permittivity is weakly load dependent.

36 MATERIALS SCIENCE↗

Extracting single fiber transverse and shear moduli from off-axis misalignment fiber tensile testing

Small diameter (<100 μm) fibers (e.g. carbon fibers, Kevlar, and fiberglass) and wires (e.g. ultrafine copper and aluminum wires) are frequently used in many different engineering applications, such as for light weighting structures, electromagnetic shielding for aircraft/infrastructure/EVs, vibration damping, biological sensors, aerospace electrical devices, and electric windings just to name a few. Due to the manufacturing process, the fibers and wires are pulled and stretched to produce a preferential alignment. Therefore, thin fibers and wires typically display different properties along the length of the fiber as opposed to their cross section and many fibers/wires are considered transversely isotropic. The axial properties of fibers/wires can be ascertained via tensile testing of single-filaments or fiber tows, but the radial properties require much more effort to measure. Knowing these properties is important for the accurate prediction of micromechanical models and manipulation of fibers during micromanufacturing. In this paper, a new technique was developed to determine the transverse/shear moduli and strength of a material by conducting tensile tests of the material at increasing misalignment angles from the tensile axis. Due to the transversely isotropic nature of the material, the transverse/shear moduli and strength influence the experimental results recorded by the test machine to different degrees based on the amount of misalignment in the test setup. An equation was derived to determine the influence of each of the material properties based on the misalignment angle by manipulating the stiffness matrix for transversely isotropic materials using the transformation matrices. Then, curve fitted coefficients were used to identify the material properties. Here, the strengths were similarly determined by curve fitting an off-axis Tsai-Hill failure criteria to determine the influence of transverse, shear, and tensile strengths based on the complex loading condition provided by the off-axis tensile test. Zoltek Panex 35 carbon fibers were used to demonstrate this new technique and the determined properties were then compared to those obtained from nanoindentation and from literature. Fracture surfaces provide insight into the different failure mechanisms at various misalignment angles.

36 MATERIALS SCIENCE↗

Superiority of compensatory reserve measurement compared with the Shock index for early and accurate detection of reduced central blood volume status

Shock index (SI) equals the ratio of heart rate (HR) to systolic blood pressure (SBP) with clinical evidence that it is more sensitive for trauma patient status assessment and prediction of outcome compared with either HR or SBP alone. We used lower body negative pressure (LBNP) as a human model of central hypovolemia and compensatory reserve measurement (CRM) validated for accurate tracking of reduced central blood volume to test the hypotheses that SI: (1) presents a late signal of central blood volume status; (2) displays poor sensitivity and specificity for predicting the onset of hemodynamic decompensation; and (3) cannot identify individuals at greatest risk for the onset of circulatory shock. We measured HR, SBP, and CRM in 172 human subjects (19–55 years) during progressive LBNP designed to determine tolerance to central hypovolemia as a model of hemorrhage. Subjects were subsequently divided into those with high tolerance (HT) (n = 118) and low tolerance (LT) (n = 54) based on completion of 60 mm Hg LBNP. The time course relationship between SI and CRM was determined and receiver operating characteristic (ROC) area under the curve (AUC) was calculated for sensitivity and specificity of CRM and SI to predict hemodynamic decompensation using clinically defined thresholds of 40% for CRM and 0.9 for SI. The time and level of LBNP required to reach a SI = 0.9 (~60 mm Hg LBNP) was significantly greater (p < 0.001) compared with CRM that reached 40% at ~40 mm Hg LBNP. Shock index did not differ between HT and LT subjects at 45 mm Hg LBNP levels. ROC AUC for CRM was 0.95 (95% CI = 0.94–0.97) compared with 0.91 (0.89–0.94) for SI (p = 0.0002). Despite high sensitivity and specificity, SI delays time to detect reductions in central blood volume with failure to distinguish individuals with varying tolerances to central hypovolemia.

60 APPLIED LIFE SCIENCES↗

Toughening materials: enhancing resistance to fracture

It has been said that ‘God invented plasticity, but the Devil invented fracture!’ Both mechanisms represent the two prime modes of structural failure, respectively, plastic collapse and the rupture/breaking of a component, but the concept of developing materials with enhanced resistance to fracture can be difficult. This is because fracture resistance invariably involves a compromise—between strength and ductility, between strength and toughness—fundamentally leading to a ‘conflict’ between nano-/micro-structural damage and the mechanisms of toughening. Here, we examine the two major classes of such toughening: (i) intrinsic toughening, which occurs ahead of a crack tip and is motivated by plasticity—this is the principal mode of fracture resistance in ductile materials, and (ii) extrinsic toughening, which occurs at, or in the wake of, a crack tip and is associated with crack-tip shielding—this is generally the sole mode of fracture resistance in brittle materials. We briefly examine how these distinct mechanistic processes have been used to toughen synthetic materials—intrinsically in gradient materials and in multiple principal-element metallic alloys with the example of metallic glasses and high-entropy alloys, and extrinsically in ceramics with the example of ceramic-matrix composites—in comparison to Nature which has been especially adept in creating biological/natural materials which are toughened by one or both mechanistic classes, despite often consisting of constituents with meagre mechanical properties. The success of Nature has been driven by its ability to cultivate the development of materials with multiple length-scale hierarchical structures that display ingenious gradients and structural adaptability, a philosophy which we need to emulate and more importantly learn to synthesize to make structural materials of the future with unprecedented combinations of mechanical properties.

36 MATERIALS SCIENCE↗

Fatigue-crack propagation behavior in a high-carbon chromium SUJ2 bearing steel: Role of microstructure

High-carbon chromium martensite steels are commonly selected for bearing components in the power generation, automotive and aerospace industries where fatigue failure is a major concern. Accordingly, it is of importance to elucidate the structure-property relationships governing the fatigue properties of such bearing steels. Here, the role of microstructure in influencing the fatigue-crack propagation behavior of a high-carbon chromium SUJ2 bearing steel is examined with emphasis on three martensitic structures: (i) a fine-grained (~10 μm) structure with intragranular (but no intergranular) carbides, (ii) a coarser-grained (~25 μm) structure with discontinuous grain-boundary carbides primarily near triple junctions, and (iii) a coarse-grained (~31 μm) structure with continuous grain-boundary carbides. Although growth rates were fairly similar above ~10 -8 m/cycle, significant differences in behavior were observed at lower, near-threshold growth rates; specifically at a load ratio of 0.1, the ΔKth fatigue threshold was increased from 3.8 MPa m ½ in the fine-grained structure to 5.9 to 6.3 MPa m ½ in the two coarser-grained structures. The dominant factor governing such near-threshold behavior was found to be crack-tip shielding from roughness-induced crack closure, which was most pronounced in the coarser-grained structures; additionally, shielding from crack deflection and branching was apparent in these structures as the crack propagated through the network of intersecting martensite lamellae within the coarse grains. Compared to high-strength stainless steels and low-strength carbon steels, the fine-grained SUJ2 steel displays an exceptional combination of high strength and fatigue-crack growth resistance and is considered to be a superior structural alloy for bearing applications.

36 MATERIALS SCIENCE↗

Active Learning A Neural Network Model For Gold Clusters & Bulk From Sparse First Principles Training Data

Small metal clusters are of fundamental scientific interest and of tremendous significance in catalysis. These nanoscale clusters display diverse geometries and structural motifs depending on the cluster size; a knowledge of this size-dependent structural motifs and their dynamical evolution has been of longstanding interest. Given the high computational cost of first-principles calculations, molecular modeling and atomistic simulations such as molecular dynamics (MD) has proven to be an important complementary tool to aid this understanding. Classical MD typically employ predefined functional forms which limits their ability to capture such complex size-dependent structural and dynamical transformation. Neural Network (NN) based potentials represent flexible alternatives and in principle, well-trained NN potentials can provide high level of flexibility, transferability and accuracy on-par with the reference model used for training. A major challenge, however, is that NN models are interpolative and requires large quantities (similar to 10 4 or greater) of training data to ensure that the model adequately samples the energy landscape both near and far-from-equilibrium. A highly desirable goal is minimize the number of training data, especially if the underlying reference model is first-principles based and hence expensive. In this work, we introduce an active learning (AL) scheme that trains a NN model on-the-fly with minimal amount of first-principles based training data. Our AL workflow is initiated with a sparse training dataset (similar to 1 to 5 data points) and is updated on-the-fly via a Nested Ensemble Monte Carlo scheme that iteratively queries the energy landscape in regions of failure and updates the training pool to improve the network performance. Using a representative system of gold clusters, we demonstrate that our AL workflow can train a NN with similar to 500 total reference calculations. Using an extensive DFT test set of similar to 1100 configurations, we show that our AL-NN is able to accurately predict both the DFT energies and the forces for clusters of a myriad of different sizes. Our NN predictions are within 30 meV/atom and 40 meV/angstrom of the reference DFT calculations. Moreover, our AL-NN model also adequately captures the various size-dependent structural and dynamical properties of gold clusters in excellent agreement with DFT calculations and available experiments. We finally show that our AL-NN model also captures bulk properties reasonably well, even though they were not included in the training data.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

OPERATING EXPERIENCE AND ITS RELATIONSHIP TO EMBEDDED DIGITAL DEVICES IN SAFETY SYSTEMS

Interest in embedded digital devices (EDDs) for monitoring and providing control of components is increasing and the added functionality digital brings such as diagnostics, displays, control functions is welcomed in both the nuclear and other industries. As a result, pure analog-based components continue to disappear from the industrial I&C marketplace. Equipment with EDDs, also known by related terms such as smart devices, intelligent devices, and digital devices of limited functionality, can include sensors, breakers, priority logic modules, time delay relays, pumps, valve actuators, motor control centers, and uninterruptible power supplies. Not only is equipment consisting of analog and older digital technology being replaced with commercial grade products containing EDDs, but EDDs can also be retrofitted to work with existing components. EDDs may be installed physically within a component, such as in a relay. There are also external devices that some would not consider an EDD, but that operate in almost all technical ways identically to one internal to a component such as in a valve controller. In fact, the digital portions may be located hundreds of feet from the actual component.Due to the potential of being used in an identical manner and without alteration from their application in other industries, operating experience (OpE) for EDDs may be much more applicable than in the case of other more system level devices. Clear separation and independence of functionality provided with EDDs may also allow greater applicability of existing OpE from industry for changes that can be shown not to affect its safety function. However, OpE also demonstrates issues with different conditions between other industries and nuclear power plants, such as issues with undeclared changes or undeclared digital devices and the new failure modes they may introduce, issues with the reporting of OpE in industry, and a lack of transparency into OpE for EDDs.Understanding and addressing these issues will be key in the future use of EDDs in nuclear power plants, but failure rate data is difficult to obtain for EDDs, and lessons learned from the use of EDDs are difficult to collect and identify.Key words: embedded digital device, smart device, operating experience, failure modes

Muhlheim, Michael↗

Oxide Semiconductor Sensors for Monitoring Advanced Energy Conversion and Manufacturing Processes at High Temperature

To optimize the operation and functionality of high temperature systems such as slagging gasifiers, coal boilers and glass/steel smelters, it is important to monitor temperature, corrosion and erosion of the refractory used in such systems. Both thermocouple and failure sensors (and arrays of these) would be useful to monitor the health of any refractory or coatings in these systems. Many of such type of sensors are installed into the systems through open access ports within the refractory; however, there are some disadvantages of this approach where corrosive/erosive gas and molten materials can penetrate and compromise the system. The current work presents the development and performance of refractory with embedded high temperature sensors such as thermocouples, thermistors, and various spallation/crack monitoring sensors, which may be used within a variety of refractory brick in different high temperature processes and applications. The objective of our work is to develop high-temperature sensors composed of electroceramic materials that are chemically stable at high temperatures (750°-1500°C) and high pressures (up to 1000 psi) that can be used in monitoring temperature, corrosion and erosion process in refractory used in high energy systems. The high-temperature sensors investigated in this work were composed of various oxide composites directly embedded into the refractory oxides. The composites used for this work were synthesized by a mixed-oxide route. Metal oxides were inserted within a matrix material composed of refractory oxides (Al2O3, ZrO2, etc.). The physical and electrical properties were specifically manipulated by altering the level of percolation of the conductive species (metal oxides) within the refractory constituent (refractory oxide). An example of one of these embedded sensors consisted of an electroceramic-based thermocouple fabricated with two separate oxide composite compositions which were patterned to produce a couple within the interior of a refractory matrix. The thermocouple successfully displayed thermoelectric voltage trend (as a function of temperature), and the voltage was 220.0 mV near 1400 °C. In addition, corrosion tests on the refractory embedded sensors were performed. To evaluate corrosion in the refractory was exposed to high-temperature glass compositions over a 90 h period. The penetration of the glass through the refractory could be monitored by both an amperometric and voltametric based sensor. With this experiment, it was demonstrated that the embedded sensor could dynamically monitor the corrosion process, and thus, provide real-time feedback on both temperature and the refractory health.

20 FOSSIL-FUELED POWER PLANTS↗

Smart Refractory Sensors Development for Corrosion and Erosion Monitoring in High Temperature Systems

To optimize the operation and functioning of high temperature systems such as slagging gasifiers, coal boilers and glass/steel melters, it is important to monitor corrosion and erosion of refractory used in such systems. Corrosion test strategies are generally based on continuous gravimetric and chemical reactivity monitoring at operational temperatures (750°-1500°C). Both thermocouples and failure sensors and arrays would be useful to monitor the health of any refractory or coatings in these systems. Many of such type of sensors are installed into the systems through open access ports within the refractory; however, there are some disadvantages of this approach where corrosive/erosive gas and molten materials can penetrate and compromise the system. The current work presents the development and performance demonstration of smart refractory with embedded high temperature sensors such as thermocouples, thermistors, and various spallation/crack monitoring sensors, which may be used within a variety of refractory brick in different high temperature processes and applications. The main feature of this technology is that electroceramic based sensors are embedded into smart refractory without significantly impact to the intrinsic properties of the refractory. This technology circumvents the need to insert an isolated monolithic, stand-alone sensor into the refractory via an access port. This technological approach guarantees the integrity and the chemical stability of the materials used in the sensor fabrication within the harsh environment and does not introduce molten material (such as slag) penetration pathways within the refractory. One interesting and important aspect of this innovation is that these embedded sensors can be used to in situ monitoring processes such as chemical reactions and at the same time give information and a deeper understanding of the corrosion and erosion process of the refractory within the system. As stated above, the objective of our work is to develop high-temperature sensors composed of electroceramic materials that are chemically stable at high temperatures (750°-1500°C) and high pressures (up to 1000 psi) that can be used in monitoring corrosion and erosion process in refractory used in high energy systems. The high-temperature sensors investigated in this work were composed of various oxide composites directly embedded into the refractory oxides. The composites used for this work were synthesized by a mixed-oxide route. Metal oxides were inserted within a matrix material composed of refractory oxides (Al2O3, ZrO2, etc.). The physical and electrical properties were specifically manipulated by altering the level of percolation of the conductive species (metal oxides) within the refractory constituent (refractory oxide). Prior to the development of the high-temperature sensors, the oxides composites developed in this study were sintered up to 1600°C under oxidizing atmosphere in order to investigate densification, microstructural evolution, phase development, and their thermoelectrical performance as a function of the composition. The 4-point DC conductivity measurements were performed between 100°-1500°C. The sensors were fabricated from the composite materials by 3D-printing or screen-printing methods into the refractory brick during the consolidation process. An example of one of these embedded sensors consisted of an electroceramic-based thermocouple fabricated with two separate oxide composite compositions which were patterned to produce a couple within the interior of a refractory matrix. The thermocouple successfully displayed thermoelectric voltage trend (as a function of temperature), and the voltage was 220.0 mV around 1400 °C. Corrosion tests on the refractory embedded sensors were performed. To evaluate corrosion in the refractory brick an in-house glass composition was prepared and pressed into pellets and delivered into a pre-cut cavity in the brick. Corrosion experiments results showed the glass penetrated the brick over a 90 h period, and the penetration of the glass through the brick could be monitored by both an amperometric and voltametric based sensor. With this experiment, it was demonstrated that the embedded sensor could dynamically monitor the corrosion process.

20 FOSSIL-FUELED POWER PLANTS↗