Search NASA⌕ Search

SEARCH · Search NASA

Results for “Distortion correction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Corrections for the geometric distortion of the tube detectors on SANS instruments at ORNL

Small-angle neutron scattering instruments at the Oak Ridge National Laboratory's High Flux Isotope Reactor were upgraded in area detectors from the large, single volume crossed-wire detectors originally installed to staggered arrays of linear position-sensitive detectors (LPSDs). The specific geometry of the LPSD array requires that approaches to data reduction traditionally employed be modified. Here, two methods for correcting the geometric distortion produced by the LPSD array are presented and compared. The first method applies a correction derived from a detector sensitivity measurement performed using the same configuration as the samples are measured. In the second method, a solid angle correction is derived that can be applied to data collected in any instrument configuration during the data reduction process in conjunction with a detector sensitivity measurement collected at a sufficiently long camera length where the geometric distortions are negligible. Furthermore, both methods produce consistent results and yield a maximum deviation of corrected data from isotropic scattering samples of less than 5% for scattering angles up to a maximum of 35°. The results are broadly applicable to any SANS instrument employing LPSD array detectors, which will be increasingly common as instruments having higher incident flux are constructed at various neutron scattering facilities around the world.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Peculiarities of adaptive phase correction of optical wave distortions under conditions of ‘strong’ intensity fluctuations

The reason for the loss of efficiency of adaptive phase correction in the propagation of optical waves in a turbulent atmosphere under conditions of ‘strong’ intensity fluctuations is experimentally explained for the first time. Based on the data from experiments conducted on both horizontal and vertical atmospheric paths, we have found that intensity fluctuations begin to significantly affect phase measurements when the coherence radius of the optical wave becomes less than the radius of the first Fresnel zone. Under these conditions, the main meter of adaptive optics systems, i. e. the Hartmann sensor, no longer provides correct measurements of the phase distribution in the presence of deep amplitude modulation. Based on the study of the behaviour of the mode components of the phase fluctuations reconstructed from the results of measurements in various operating regimes, we have found that, first of all, the amplitudes of the lowest modes of phase fluctuation expansion (tilts, defocusing, and astigmatism) are distorted, which, as the analysis shows, is very different from the regime of weak fluctuations. (atmospheric optics)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Integrators

Many electromagnetic measurements detect signals that are the time derivative of the actual quantity of interest. Examples include so-called “B-dot” and “D-dot” detectors that are used for measuring transient magnetic and electric fields. Integration of these signals to recover the quantity of interest is performed either by hardware integrators in the signal line, or by software coding in the analysis programming. Hardware integration is usually done using a classic resistive-capacitive (RC) circuit, or internally in the detector by induction (L/R) or stray capacitance (RC). These hardware integration methods are only approximate, and must be corrected for distortion. This is usually called “droop correction.” In this note, we will examine this correction in some detail. Transient analysis via Laplace transforms will be used to simplify the mathematics. A rudimentary understanding of this method is assumed.

42 ENGINEERING↗

Calibration of the ProtoDUNE Horizontal-Drift position reconstruction using a laser system

Forthcoming in the next decade of neutrino physics advancements is the construction of the Deep Underground Neutrino Experiment (DUNE), a long baseline neutrino oscillation experiment which has the potential to answer fundamental questions such as why there is more matter than antimatter in the universe, and ultimately why we exist at all. A prototype of this experiment, ProtoDUNE, sits in a charged particle test beam at the European Organization for Nuclear Research (CERN) and uses Liquid Argon time projection chambers to image interactions of these particles. ProtoDUNE Single-Phase (ProtoDUNESP) had positively charged hadrons as well as positrons in its initial 2018 beam data run. Because ProtoDUNE is a surface-based time projection chamber, it experiences a constant influx of cosmic rays. These cosmic rays ionize the liquid argon within the detector, resulting in an accumulation of slow moving positive ions towards the cathode. This local charge distribution results in electric field non uniformities, which can have a significant effect on the accuracy of the event reconstruction. This paper outlines a monte carlo simulation study which adapts methodology from the MicroBooNE experiment, another neutrino oscillation experiment, to derive electric field correction maps which can correct for distortions of the electric field within the detector. These correction maps accurately estimate the electric field throughout the detector volume and correct for uncertainties in reconstructed event data enabling for physics discoveries.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Coulomb corrections in quasi-elastic scattering: Tests of the effective-momentum approximation

Coulomb corrections for quasielastic scattering of electrons by nuclei are calculated using eikonal distorted waves. Corrections to the lowest-order eikonal approximation are included to obtain accurate results. Spin-dependent eikonal phase shifts are evaluated and they yield very small corrections to the longitudinal and transverse cross sections at electron energies of 500 MeV or higher. Because of this the Rosenbluth procedure is accurate for separation of the longitudinal and transverse response functions. The effective-momentum approximation is also found to be accurate with regard to removal of the remaining Coulomb effects from the distorted waves. Calculations are presented for electron scattering from {sup 208}Pb and {sup 56}Fe nuclei at energies of 500 and 800 MeV and momentum transfers q=550 and 900 MeV/c.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Continuous table acquisition MRI for radiotherapy treatment planning: Distortion assessment with a new extended 3D volumetric phantom

Purpose: Accurate geometry is required for radiotherapy treatment planning (RTP). When considering the use of magnetic resonance imaging (MRI) for RTP, geometric distortions observed in the acquired images should be considered. While scanner technology and vendor supplied correction algorithms provide some correction, large distortions are still present in images, even when considering considerably smaller scan lengths than those typically acquired with CT in conventional RTP. This study investigates MRI acquisition with a moving table compared with static scans for potential geometric benefits for RTP. Methods: A full field of view (FOV) phantom (diameter 500 mm; length 513 mm) was developed for measuring geometric distortions in MR images over volumes pertinent to RTP. The phantom consisted of layers of refined plastic within which vitamin E capsules were inserted. The phantom was scanned on CT to provide the geometric gold standard and on MRI, with differences in capsule location determining the distortion. MRI images were acquired with two techniques. For the first method, standard static table acquisitions were considered. Both 2D and 3D acquisition techniques were investigated. With the second technique, images were acquired with a moving table. The same sequence was acquired with a static table and then with table speeds of 1.1 mm/s and 2 mm/s. All of the MR images acquired were registered to the CT dataset using a deformable B-spline registration with the resulting deformation fields providing the distortion information for each acquisition. Results: MR images acquired with the moving table enabled imaging of the whole phantom length while images acquired with a static table were only able to image 50%–70% of the phantom length of 513 mm. Maximum distortion values were reduced across a larger volume when imaging with a moving table. Increased table speed resulted in a larger contribution of distortion from gradient nonlinearities in the through-plane direction and an increased blurring of capsule images, resulting in an apparent capsule volume increase by up to 170% in extreme axial FOV regions. Blurring increased with table speed and in the central regions of the phantom, geometric distortion was less for static table acquisitions compared to a table speed of 2 mm/s over the same volume. Overall, the best geometric accuracy was achieved with a table speed of 1.1 mm/s. Conclusions: The phantom designed enables full FOV imaging for distortion assessment for the purposes of RTP. MRI acquisition with a moving table extends the imaging volume in the z direction with reduced distortions which could be useful particularly if considering MR-only planning. If utilizing MR images to provide additional soft tissue information to the planning CT, standard acquisition sequences over a smaller volume would avoid introducing additional blurring or distortions from the through-plane table movement.

60 APPLIED LIFE SCIENCES↗

Correction of MRI-induced geometric distortions in whole-body small animal PET-MRI

Purpose: The fusion of positron emission tomography (PET) and magnetic resonance imaging (MRI) data can be a challenging task in whole-body PET-MRI. The quality of the registration between these two modalities in large field-of-views (FOV) is often degraded by geometric distortions of the MRI data. The distortions at the edges of large FOVs mainly originate from MRI gradient nonlinearities. This work describes a method to measure and correct for these kind of geometric distortions in small animal MRI scanners to improve the registration accuracy of PET and MRI data. Methods: The authors have developed a geometric phantom which allows the measurement of geometric distortions in all spatial axes via control points. These control points are detected semiautomatically in both PET and MRI data with a subpixel accuracy. The spatial transformation between PET and MRI data is determined with these control points via 3D thin-plate splines (3D TPS). The transformation derived from the 3D TPS is finally applied to real MRI mouse data, which were acquired with the same scan parameters used in the phantom data acquisitions. Additionally, the influence of the phantom material on the homogeneity of the magnetic field is determined via field mapping. Results: The spatial shift according to the magnetic field homogeneity caused by the phantom material was determined to a mean of 0.1 mm. The results of the correction show that distortion with a maximum error of 4 mm could be reduced to less than 1 mm with the proposed correction method. Furthermore, the control point-based registration of PET and MRI data showed improved congruence after correction. Conclusions: The developed phantom has been shown to have no considerable negative effect on the homogeneity of the magnetic field. The proposed method yields an appropriate correction of the measured MRI distortion and is able to improve the PET and MRI registration. Furthermore, the method is applicable to whole-body small animal imaging routines including different standard MRI sequences.

60 APPLIED LIFE SCIENCES↗

Three dimensional imaging and analysis of a single nano-device at the ultimate scale using correlative microscopy techniques

The analysis of a same sample using nanometre or atomic-scale techniques is fundamental to fully understand device properties. This is especially true for the dopant distribution within last generation nano-transistors such as MOSFET or FINFETs. In this work, the spatial distribution of boron in a nano-transistor at the atomic scale has been investigated using a correlative approach combining electron and atom probe tomography. The distortions present in the reconstructed volume using atom probe tomography have been discussed by simulations of surface atoms using a cylindrical symmetry taking into account the evaporation fields. Electron tomography combined with correction of atomic density was used so that to correct image distortions observed in atom probe tomography reconstructions. These corrected atom probe tomography reconstructions then enable a detailed boron doping analysis of the device.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-E-I-41: Non-Cartesian MR Image Reconstruction with Integrated Gradient Non-Linearity Correction

Purpose: Nonlinearities in the spatial encoding gradients of MRI systems cause geometric distortion in images. Typically, this is retrospectively corrected via image-domain interpolation (a.k.a., “gradwarp”) albeit with a loss of spatial resolution. For non-Cartesian MRI, the latter problem is exaggerated by noise and undersampling artifact. In this study, we describe a novel correction strategy that accounts for gradient nonlinearities during — rather than after — non-Cartesian MRI reconstruction, and demonstrate that this approach mitigates the resolution loss that can occur with standard methods. Methods: To test the proposed method, the American College of Radiology (ACR) quality control phantom was scanned on at 1.5 T (General Electric, v16.0, “zoom” gradient) using a 1.6x undersampled 3D non- Cartesian Shells trajectory (GRE, FOV=24 cm3, 120 shells, 16552 shots, 512 readout, matrix=2403). Image reconstruction was first performed via standard k-space density-compensated gridding and retrospectively corrected via cubic spline interpolation. Image reconstruction was then separately performed using a k-space and image-domain densitycompensated type-3 non-uniform fast Fourier transform (NUFFT), which provides a direct mapping between non-Cartesian k-space samples and warped image space voxel locations. Thus, no separate distortion correction procedure is needed for the proposed approach. The gradient distortion field was determined using vendor provided calibration data. Results: Phantom scan results show that both processing approaches successfully correct geometric distortion. However, visual inspection of the ACR phantom spatial resolution inserts shows that the proposed strategy preserves the resolution of the nominal (uncorrected) reconstruction while “gradwarp” imparts marked spatial blurring (especially for the 1.0 and 1.1 mm inserts) and thus resolution loss. Conclusion: We've presented a novel reconstruction strategy for non-Cartesian MRI that corrects for gradient nonlinearities during — rather than after — reconstruction, and thus better preserves image resolution than traditional interpolation-based methods. This approach is expected to be especially advantageous when imaging with non-standard magnet geometries. NIH RR018898; NIH EB10065.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thermodynamically constrained correction to ab initio equations of state

We show how equations of state generated by density functional theory methods can be augmented to match experimental data without distorting the correct behavior in the high- and low-density limits. The technique is thermodynamically consistent and relies on knowledge of the density and bulk modulus at a reference state and an estimation of the critical density of the liquid phase. We apply the method to four materials representing different classes of solids: carbon, molybdenum, lithium, and lithium fluoride. It is demonstrated that the corrected equations of state for both the liquid and solid phases show a significantly reduced dependence of the exchange-correlation functional used.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A CONVENIENT SOLUTION TO GEOMETRIC DISTORTION AND ITS APPLICATION TO PHOEBE'S OBSERVATIONS

A simple but effective approach is proposed for measuring the geometric distortion of a CCD field of view of a ground-based telescope. For three open clusters (M35, M67, and NGC 2324), 425 CCD frames taken by a 1 m telescope at the Yunnan Observatory are used to test this approach. It is found that the geometric distortion pattern depends strongly on the corresponding filter used. The geometric distortion is then used to correct the pixel positions for Phoebe, the ninth satellite of Saturn, and its reference stars imaged in 220 CCD frames taken by the same telescope. The standard deviation of the (O - C; observed minus computed) residuals of Phoebe is significantly improved after correcting the geometric distortions.

79 ASTRONOMY AND ASTROPHYSICS↗

Deep learning-based noise filtering toward millisecond order imaging by using scanning transmission electron microscopy

Application of scanning transmission electron microscopy (STEM) to in situ observation will be essential in the current and emerging data-driven materials science by taking STEM’s high affinity with various analytical options into account. As is well known, STEM’s image acquisition time needs to be further shortened to capture a targeted phenomenon in real-time as STEM’s current temporal resolution is far below the conventional TEM’s. However, rapid image acquisition in the millisecond per frame or faster generally causes image distortion, poor electron signals, and unidirectional blurring, which are obstacles for realizing video-rate STEM observation. Here we show an image correction framework integrating deep learning (DL)-based denoising and image distortion correction schemes optimized for STEM rapid image acquisition. By comparing a series of distortion corrected rapid scan images with corresponding regular scan speed images, the trained DL network is shown to remove not only the statistical noise but also the unidirectional blurring. This result demonstrates that rapid as well as high-quality image acquisition by STEM without hardware modification can be established by the DL. The DL-based noise filter could be applied to in-situ observation, such as dislocation activities under external stimuli, with high spatio-temporal resolution.

47 OTHER INSTRUMENTATION↗

macroMS: Image-Guided Analysis of Random Objects by Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry

Mass spectrometry imaging is well-suited to characterizing sample surfaces for their chemical content in a spatially resolved manner. However, when the surface contains small objects with significant empty spaces between them, more efficient approaches to sample acquisition are possible. Image-guided mass spectrometry (MS) enables high-throughput analysis of a diverse range of sample types, such as microbial colonies, liquid microdroplets, and others, by recognizing and analyzing selected location targets in an image. Here, we describe an imaging protocol and macroMS, an online software suite that can be used to enhance MS measurements of macroscopic samples that are imaged by a camera or a flatbed scanner. Furthermore, the web-based tool enables users to find and filter targets from the optical images, correct optical distortion issues for improved spatial location of selected targets, input the custom geometry files into an MS device to acquire spectra at the selected locations, and finally, perform limited data analysis and use visualization tools to aid locating samples containing compounds of interest. Using the macroMS suite, an enzyme mutant library of Saccharomyces cerevisiae and nL droplet arrays of Escherichia coli and Pseudomonas fluorescens have been assayed at a rate of ~2 s/sample.

47 OTHER INSTRUMENTATION↗

In vivo volumetric imaging of calcium and glutamate activity at synapses with high spatiotemporal resolution

Studying neuronal activity at synapses requires high spatiotemporal resolution. For high spatial resolution in vivo imaging at depth, adaptive optics (AO) is required to correct sample-induced aberrations. To improve temporal resolution, Bessel focus has been combined with two-photon fluorescence microscopy (2PFM) for fast volumetric imaging at subcellular lateral resolution. To achieve both high-spatial and high-temporal resolution at depth, we develop an efficient AO method that corrects the distorted wavefront of Bessel focus at the objective focal plane and recovers diffraction-limited imaging performance. Applying AO Bessel focus scanning 2PFM to volumetric imaging of zebrafish larval and mouse brains down to 500 µm depth, we demonstrate substantial improvements in the sensitivity and resolution of structural and functional measurements of synapses in vivo. This enables volumetric measurements of synaptic calcium and glutamate activity at high accuracy, including the simultaneous recording of glutamate activity of apical and basal dendritic spines in the mouse cortex.

59 BASIC BIOLOGICAL SCIENCES↗

Electron contamination modeling and reduction in a 1 T open bore inline MRI-linac system

Purpose: A potential side effect of inline MRI-linac systems is electron contamination focusing causing a high skin dose. In this work, the authors reexamine this prediction for an open bore 1 T MRI system being constructed for the Australian MRI-Linac Program. The efficiency of an electron contamination deflector (ECD) in purging electron contamination from the linac head is modeled, as well as the impact of a helium gas region between the deflector and phantom surface for lowering the amount of air-generated contamination. Methods: Magnetic modeling of the 1 T MRI was used to generate 3D magnetic field maps both with and without the presence of an ECD located immediately below the MLC’s. Forty-seven different ECD designs were modeled and for each the magnetic field map was imported into Geant4 Monte Carlo simulations including the linac head, ECD, and a 30 × 30 × 30 cm{sup 3} water phantom located at isocenter. For the first generation system, the x-ray source to isocenter distance (SID) will be 160 cm, resulting in an 81.2 cm long air gap from the base of the ECD to the phantom surface. The first 71.2 cm was modeled as air or helium gas, with the latter encased between two windows of 50 μm thick high density polyethlyene. 2D skin doses (at 70 μm depth) were calculated across the phantom surface at 1 × 1 mm{sup 2} resolution for 6 MV beams of field size of 5 × 5, 10 × 10, and 20 × 20 cm{sup 2}. Results: The skin dose was predicted to be of similar magnitude as the generic systems modeled in previous work, 230% to 1400% ofD {sub max} for 5 × 5 to 20 × 20 cm{sup 2}, respectively. Inclusion of the ECD introduced a nonuniformity to the MRI imaging field that ranged from ∼20 to ∼140 ppm while the net force acting on the ECD ranged from ∼151 N to ∼1773 N. Various ECD designs were 100% efficient at purging the electron contamination into the ECD magnet banks; however, a small percentage were scattered back into the beam and continued to the phantom surface. Replacing a large portion of the extended air-column between the ECD and phantom surface with helium gas is a key element as it significantly minimized the air-generated contamination. When using an optimal ECD and helium gas region, the 70 μm skin dose is predicted to increase moderately inside a small hot spot over that of the case with no magnetic field present for the jaw defined square beams examined here. These increases include from 12% to 40% of D {sub max} for 5 × 5 cm{sup 2}, 18% to 55% of D {sub max} for 10 × 10 cm{sup 2}, and from 23% to 65% of D {sub max} for 20 × 20 cm{sup 2}. Conclusions: Coupling an efficient ECD and helium gas region below the MLCs in the 160 cm isocenter MRI-linac system is predicted to ameliorate the impact electron contamination focusing has on skin dose increases. An ECD is practical as its impact on the MRI imaging distortion is correctable, and the mechanical forces acting on it manageable from an engineering point of view.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Geometric Interpretation of the Cluster Location Problem Part I: Theory

We present a new framing of the seismic location problem using principles drawn from differential geometry. Our interpretation relies upon the common assumption that travel times observed across a network are continuous, differentiable functions of source location. In consequence, travel‐time functions constitute a differentiable map between the source region and a Riemannian manifold. The manifold is said to be the image of the source region embedded in a generally high‐dimension travel‐time vector space. A cluster of events in the source region has an image of discrete points on the manifold, that, except in the simplest cases, cannot be viewed directly. However, it is possible to project the image of a cluster into a tangent space of the manifold for direct visualization. The projection operator can be computed directly from the data without a velocity model, but produces a distorted rendering of the cluster geometry. With a model we can predict the distortions and correct them to estimate cluster geometry. We develop these points with the simplest possible example, one for which direct visualization of the manifold is possible, using the example as an introduction to the relevant concepts from differential geometry in a familiar setting. The tangent space, a local linearization of the manifold, plays a key role. We develop a metric to estimate the limits of linearization, that is, to determine when the curvature of the manifold invalidates the linear assumption. We also examine the interplay of model error, inadequate network geometry, and pick error. We then generalize our results from the simple case to the general case of 3D source regions observed by general networks. Although we do suggest a new “project and correct” method for location, we do not develop it into a practical algorithm. In conclusion, our intention rather is to highlight new analytical methods grounded in differential geometry.

East Pacific Ocean Islands↗

AFIP-7 Tomography – 2013 Status Report

This project seeks to assess the geometric stability of the U-Mo monolithic fuel system by evaluating the radiation-induced changes in the AFIP-7 experiment device. Neutron radiography and computed tomography (CT) provide valuable information about the post-irradiation condition of the fuel specimen. Tomographic reconstructions of the AFIP-7 fuel element will be analyzed to assess the geometric condition of the element after irradiation and provide information regarding the condition of the fuel, including gross geometric defects, bowing, twist, plate buckling, cracks, and other defects. The INL, in collaboration with Oregon State University (OSU), Missouri University of Science and Technology (Missouri S&T), and Real Time Tomography, is developing advanced neutron detector systems and tomographic reconstruction techniques to evaluate the AFIP-7 fuel element. Neutron computed tomography using the current neutron radiography technique available at the Neutron Radiography reactor (NRAD) is impractical due to the long time and high cost to produce a set of images for tomographic reconstruction. Advanced neutron radiography systems such as the micro-channel plate (MCP) detector and neutron computed radiography (CR) may reduce the time and cost of acquiring images for neutron CT. The MCP detector system tested at OSU and Missouri S&T provides neutron radiographs and has lower gamma sensitivity compared to other digital acquisition image systems. However, some significant, but not prohibitive, challenges must be overcome to make its use for imaging nuclear fuel more practical. Images taken with the MCP require significant image processing to reduce distortions and correct for the dynamic detector response. Also, the small active area of the detector (~30 mm diameter) requires the collection and combination of several images of a specimen, which may become time-consuming. The MCP is tested in low gamma dose environments, but should also be tested in the gamma field at the INL. In addition to the MCP detector system, the INL is developing neutron computed radiography (CR), which uses the same foil transfer method currently employed at the NRAD, but replaces the film with a photostimulable storage phosphor imaging plate that is sensitive to the decay radiation from the activated transfer foils. Preliminary tests show that neutron CR provides lower, but comparable spatial resolution properties to film radiography images using the transfer method technique already employed at the NRAD. However, there are many factors that affect the spatial resolution of neutron CR that can be adjusted and possibly provide spatial resolution properties that exceed film radiography. The reduction in cost of neutron CR may be significant, which would make neutron imaging more appealing to programs that would benefit from this rare and valuable capability. Because transfer method neutron radiography is expensive and time-consuming, acquisition of a full set of radiographs for tomographic reconstruction is impractical. The INL is developing tomographic reconstruction techniques that require only a small set of radiographs of the AFIP-7 fuel element. These tomosynthesis techniques are tested using archived radiographs of TREAT experiments for CT as a proof of principle. These same techniques are applied to radiographs taken with an MCP detector of a mock-up of the AFIP-7 geometry. Acquisition angle should at least match the curvature of AFIP-7 plates. Lateral (in-plane) reconstruction resolution will be best when the projection angles include views at or near the desired reconstruction view angles. The ends of the fuel plates are angled at ±17.7° relative to the center of the plate. Increasing the number of projections is desirable, but given the constraint of minimizing the number of projections, the projection acquisition angle should also span at least ±17.7° to optimize the lateral resolution of the angled reconstruction planes used to visualize the gaps at the ends of the fuel plates. If possible, enough projections should be used within the initial acquisition angle of 35.4° (±17.7°) to bring the projection angular sampling closer to 1°. Further testing will determine a more specific recommendation for the number and angular distribution of neutron radiographs that will produce the highest quality tomographic reconstruction of the AFIP-7 fuel element.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗