Distribution system state estimation (DSSE) is one of the vital components in the next-generation distribution management system which allows operators to monitor the entire system's operating conditions. Due to the lack of real-time measurements, DSSE has to process measurements whose quality varies significantly across different sources, which causes a convergence issue to the Gauss-Newton solver. In this paper, a semidefinite programming (SDP) framework is proposed to reformulate the DSSE problem into a rank- constrained SDP problem. One challenge of this technique is the nonconvex rank-one constraint, which is generally relaxed. However, the relaxed SDP-DSSE problem cannot guarantee a rank-one solution and hence loses optimality. Therefore, we propose two solution approaches to obtain rank-one solutions for the SDPDSSE problem: the rank reduction approach and the convex iteration approach. The model and the effectiveness of the proposed solution approaches are numerically demonstrated on the IEEE 13-bus, 34-bus, and 123-bus distribution systems.
Distribution systems are currently facing steep operational challenges as a result of the rapidly increasing integration of renewables and other distributed energy resources (DERs)at both the primary and secondary circuit levels. Distribution utilities and system operators have traditionally had some visibility of their primary circuits using low-frequency supervisory control and data acquisition systems, and they have had very poor if not zero visibility of the secondary circuits where the presence of DERs is constantly increasing. Therefore, this paper presents simulation studies to demonstrate the benefits of an advanced, high-fidelity sensor technology, called as the Meta-Alert System (MAS), developed by Electrical Grid Monitoring Ltd. (EGM), on the distribution grid. First, a reliable model of the EGM sensors is developed, and then two use cases - distribution system state estimation (DSSE) and fault identification - are simulated to evaluate the performance of the MAS technology. Simulation results on the Electric Power Research Institute J1feeder demonstrate that the MAS can effectively participate in system-level DSSE programs and can detect and locate faults faster than traditional distribution protection schemes.
Distribution network operation is becoming more challenging because of the growing integration of intermittent and volatile distributed energy resources (DERs). This motivates the development of new distribution system state estimation (DSSE) paradigms that can operate at fast timescale based on real-time data stream of asynchronous measurements enabled by modern information and communications technology. To solve the real-time DSSE with asynchronous measurements effectively and accurately, this paper formulates a weighted least squares DSSE problem and proposes an online stochastic gradient algorithm to solve it. The performance of the proposed scheme is analytically guaranteed and is numerically corroborated with realistic data on IEEE 123-bus feeder.
Not provided.
This paper examines the problem of state estimation in power distribution systems under low-observability conditions. The recently proposed constrained matrix completion method which combines the standard matrix completion method and power flow constraints has been shown to be effective in estimating voltage phasors under low-observability conditions using single-snapshot information. However, the method requires solving a semidefinite programming (SDP) problem, which becomes computationally infeasible for large systems and if multiple-snapshot (time-series) information is used. This paper proposes an efficient algorithm to solve the constrained matrix completion problem with time-series data. This algorithm is based on reformulating the matrix completion problem as a bilinear (non-convex) optimization problem, and applying the alternating minimization algorithm to solve this problem. This paper proves the summable convergence of the proposed algorithm, and demonstrates its efficacy and scalability via IEEE 123-bus system and a real utility feeder system. This paper also explores the value of adding more data from the history in terms of computation time and estimation accuracy.
This paper examines the problem of state estimation in power distribution systems under low-observability conditions. The recently proposed constrained matrix completion method which combines the standard matrix completion method and power flow constraints has been shown to be effective in estimating voltage phasors under low-observability conditions using single-snapshot information. However, the method requires solving a semidefinite programming (SDP) problem, which becomes computationally infeasible for large systems and if multiple-snapshot (time-series) information is used. This paper proposes an efficient algorithm to solve the constrained matrix completion problem with time-series data. This algorithm is based on reformulating the matrix completion problem as a bilinear (non-convex) optimization problem, and applying the alternating minimization algorithm to solve this problem. This paper proves the summable convergence of the proposed algorithm, and demonstrates its efficacy and scalability via IEEE 123-bus system and a real utility feeder system. This paper also explores the value of adding more data from the history in terms of computation time and estimation accuracy.
Promptly perceiving distribution system states is challenged by frequent topology changes and uncertain power injections. To address these issues, a Meta-learning enhanced physics-informed graph attention convolutional network (Meta-PIGACN) model is proposed to handle topological variability in distribution system state estimation (DSSE). Specifically, physics information is integrated into the graph convolutional network, enabling a physics-informed edge-weighting process that incorporates physical information to control the aggregation of neighboring nodes. Besides, the graph attention mechanism automatically adjusts the importance of different neighboring nodes, allowing the capture and preservation of inherent system features across varying topologies, thereby improving state estimation accuracy. Furthermore, meta-learning is proposed to acquire empirical knowledge across multiple topologies so that the model can rapidly adapt to new configurations through iterative gradient descent updates even in large-scale systems. In conclusion, the simulation results based on the 33/118/1746-node distribution systems show the high accuracy and efficiency of the proposed model.
We address the problem of distributed estimation of eigenvectors for power system models using online phasor measurements. The power system is considered to be divided into a set of non-overlapping areas, each of which is equipped with a local estimator. Online measurements of bus voltage and current phasors are first used to generate estimates of the generator states in each area using decentralized Kalman filters. Thereafter, these estimates are used for identifying a reduced-order model of the system in a completely distributed way by sharing state information between the estimators over a strongly connected communication graph. The identified model is then utilized to estimate its right eigenvectors over the same distributed graph. Results are validated using a 50-bus power system model with four areas.
The inclusion of PMU functionality in distribution relays enables the implementation of a linear state estimator (LSE) in Distribution Systems (DS). However, the unbalanced topology and phase coupling in distribution lines necessitate modifications to the LSE formulation. Additionally, the higher fault frequency in distribution systems requires a state estimation approach that is resilient to contingencies. This work proposes an adaptive linear state estimation algorithm tailored for unbalanced distribution systems with single-phase and two-phase laterals. Furthermore, a modified Optimal PMU Placement (OPP) strategy is introduced to ensure full observability in distribution systems with single-phase and two-phase buses. To maintain adaptability to topology changes, the state estimator incorporates circuit breaker status data provided by PMUs, ensuring robust performance during topology changes triggered by faults. The performance of the algorithm is verified on the IEEE 13-bus, 34-bus, and 123-bus systems.
State estimation is often a challenging task in distribution systems due to deploying a limited number of measurement devices. Moreover, the integration of precise distributionlevel phasor measurement unites, a.k.a micro-PMUs, along with inaccurate pseudo-measurements in state estimation introduces another challenge. These issues might decrease the efficiency of traditional standard weighted least squares (WLS) for distribution system state estimation. This paper proposes a novel linear distribution system state estimation with taken different types of measurements, including micro-PMU measurements and line current measurements, into account. To involve pseudomeasurements into the linear state estimation, a linearization method based on the Taylor’s approximation is adopted to reformulate pseudo-measurement functions in a linear form. The results obtained via numerical simulations show that the proposed linear state estimation method performs similarly to the standard nonlinear WLS estimator. In addition, the sensitivity analyses results show that our method has a better performance compared to WLS once a limited number of highly precise micro-PMUs are accompanied with inaccurate pseudo-measurements in state estimation.
To support the operation of modern distribution systems, operators require real-time visibility into system states. Due to a lack of measurements and unbalanced operation, the state estimation in distribution systems is challenging as compared to transmission systems. This paper proposes the utilization of a Multiple Iteration - Extended Kalman Filter based approach for the distribution system state estimation. This modified version of the baseline extended Kalman filter iterates over the update step multiple times thereby reducing the estimation error. The proposed algorithm along with the auxiliary algorithms such as bad data detection is integrated into a co-simulation environment. Case studies show that the proposed state estimation method can result in a lesser estimation error as compared to the baseline approach.
Forensic capabilities to understand chemical and nuclear explosions are greatly aided by an accurate estimate of explosive yield with uncertainty. The relationship between explosive size and geophysical observations of seismic, acoustic, and optical waves can be exploited to provide an estimate of yield. Any near-surface yield estimate is complicated by the surface interaction, so an estimate for the explosion height-of-burst is necessarily included in the relationship. Additionally, the relationship dictates a trade-off between estimates of yield and height-of-burst. Fortunately, the surface interaction for each type of observation is different, which breaks the trade-off, and the inclusion of height-of-burst with multiple data types improves yield estimation. We define simple parametric forward models to relate seismoäcoustoöptic observations from a data set of known explosive yields and height-of-bursts. The parameters of the models and a prediction for the yield and height-of-burst of a new event can then be estimated given new observations via Bayesian inference. We report posterior distribution estimates of the parametric models using a Markov chain Monte Carlo sampling technique. These models are then used to predict the yield and height-of-burst of SUGAR, a historical near-surface nuclear explosion, using its reported historical observations. The reported yield of 1.2 ktonne Trinitrotoluene (TNT)-equivalent (Department of Energy, 2015) is within the estimated posterior. Yield uncertainty can be estimated from the spread of the posterior, which is between 0.9 and 2.1 ktonne TNT-equivalent. The posterior for height-of-burst has a wider range between 10 m below and 8 m above ground that includes the true height-of-burst of 1 m.
This paper studies the optimal meter placement problem for distribution system state estimation given limited measurement resources. We formulate the problem as a mixed integer semi-definite programming that minimizes the worst case estimation errors over a set of operating points. To solve the problem, we first relax the problem as a convex optimization problem. Motivated by the lack of scalability of existing solvers, we next leverage the special structure of the cost function and propose an algorithm based on barrier method that solves the problem with significantly better numerical performance. The proposed method has been validated on the IEEE 13-bus, IEEE 123-bus, and IEEE 8,500-bus feeders.
This article considers the low-observability state estimation problem in power distribution networks and develops a decentralized state estimation algorithm leveraging the matrix completion methodology. Matrix completion has been shown to be an effective technique in state estimation that exploits the low dimensionality of the power system measurements to recover missing information. This technique can utilize an approximate (linear) load flow model, or it can be used with no physical models in a network where no information about the topology or line admittance is available. The direct application of matrix completion algorithms requires solving a semi-definite programming (SDP) problem, which becomes computationally challenging for large networks. We therefore develop a decentralized algorithm that capitalizes on the popular proximal alternating direction method of multipliers (proximal ADMM). The method allows us to distribute the computation among different areas of the network, leading to a scalable algorithm. By doing all computations at individual control areas and only communicating with neighboring areas, the algorithm eliminates the need for data to be sent to a central processing unit and thus increases efficiency and contributes to the goal of autonomous control of distribution networks. We illustrate the advantages of the proposed algorithm numerically using standard IEEE test cases.
The power grid is undergoing massive changes to ensure resiliency and reliability in a more decentralized world. Distributed energy resources are becoming a prominent source of generation, potentially leading to a lack of centralized generation sources. Due to these new behaviors and system topologies, it is important to install measurement devices that are 1) accurate and 2) self-aware of their measurement quality. In this paper, a residential-scale microgrid is used to generate voltage and current waveforms, captured by Verivolt and National Instruments measurement equipment. A least-squares approach is used to separate the “clean” signals from the noise. Finally, Gaussian mixture modeling is used to approximate noise distributions, and it is shown these higher-order distribution estimates are a better fit to voltage and current noise profiles than single-mode Gaussian estimates.