Search NASA⌕ Search

SEARCH · Search NASA

Results for “Distributed Time Protocol”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

A Comparison of Phasor Communication Protocols

In this paper, we compare three approaches used for continuous transfer of real-time synchrophasor data: IEEE C37.118.2-2011, IEC TR 61850-90-5 and a new protocol being developed under the Department of Energy (DOE) project DOE-OE-859 called the Streaming Telemetry Transport Protocol (STTP). STTP is currently being advanced as a potential third standard protocol via the IEEE Power Engineering Society STTP P10 Work Group (P2664). Each of these three synchrophasor protocols is described in detail in this paper along with the basis for their operating characteristics using Internet Protocol (IP) transport. The dominant protocol for the exchange of synchrophasor data is IEEE C37.118, both in the U.S. and internationally. The most recent IEEE C37.118 standard is broken into two parts where IEEE C37.118.1-2011 (Part 1) defines the normative synchrophasor measurement requirements and IEEE C37.118.2-2011 (Part 2) defines the protocol’s data transmission format. Both the IEC TR 61850-90-5 and the emergent STTP specifications only address synchrophasor data transmission; therefore, this paper focuses on comparing the data transmission protocol elements of these standards. The primary dimensions of comparison of these three protocols explored in this paper are: structure, efficiency, susceptibility to data loss, scalability, security, and other operability functionality. Additionally, though not specifically relevant to synchrophasor data telemetry, the three protocols are evaluated with respect to flexibility for transporting non-synchrophasor precise-time data streams.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Review of Design Elements within Power Infrastructure Cyber–Physical Test Beds as Threat Analysis Environments

Cyber–physical systems (CPSs) are an integral part of modern society; thus, enhancing these systems’ reliability and resilience is paramount. Cyber–physical testbeds (CPTs) are a safe way to test and explore the interplay between the cyber and physical domains and to cost-effectively enhance the reliability and resilience of CPSs. Here a review of CPT elements, broken down into physical components (simulators, emulators, and physical hardware), soft components (communication protocols, network timing protocols), and user interfaces (visualization-dashboard design considerations) is presented. Various methods used to validate CPS performance are reviewed and evaluated for potential applications in CPT performance validation. Last, initial simulated results for a CPT design, based on the IEEE 33 bus system, are presented, along with a brief discussion on how model-based testing and fault–injection-based testing (using scaling and ramp-type attacks) may be used to help validate CPT performance.

14 SOLAR ENERGY↗

Hyperentangled Time-Bin and Polarization Quantum Key Distribution

Fiber-based quantum communication networks are currently limited without quantum repeaters. Satellite-based quantum links have been proposed to extend the network domain. Here, we develop a quantum communication system, suitable for realistic satellite-to-ground communication. With this system, we execute an entanglement-based quantum key distribution (QKD) protocol developed by Bennett, Brassard, and Mermin (BBM92), achieving quantum bit-error rates (QBERs) below 2% in all bases. More importantly, we demonstrate low-QBER execution of a higher-dimensional hyperentanglement-based QKD protocol, using photons simultaneously entangled in polarization and time bin, leading to significantly higher secure key rates, at the cost of increased technical complexity and system size. We show that our protocol is suitable for a space-to-ground link, after incorporating Doppler-shift compensation, and verify its security using a rigorous finite-key analysis. Additionally, we discuss system-engineering considerations relevant to those and other quantum communication protocols and their dependence on what photonic degrees of freedom are utilized.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Therapeutic analysis of high-dose-rate {sup 192}Ir vaginal cuff brachytherapy for endometrial cancer using a cylindrical target volume model and varied cancer cell distributions

Purpose: To evaluate high-dose-rate (HDR) vaginal cuff brachytherapy (VCBT) in the treatment of endometrial cancer in a cylindrical target volume with either a varied or a constant cancer cell distributions using the linear quadratic (LQ) model. Methods: A Monte Carlo (MC) technique was used to calculate the 3D dose distribution of HDR VCBT over a variety of cylinder diameters and treatment lengths. A treatment planning system (TPS) was used to make plans for the various cylinder diameters, treatment lengths, and prescriptions using the clinical protocol. The dwell times obtained from the TPS were fed into MC. The LQ model was used to evaluate the therapeutic outcome of two brachytherapy regimens prescribed either at 0.5 cm depth (5.5 Gy × 4 fractions) or at the vaginal mucosal surface (8.8 Gy × 4 fractions) for the treatment of endometrial cancer. An experimentally determined endometrial cancer cell distribution, which showed a varied and resembled a half-Gaussian distribution, was used in radiobiology modeling. The equivalent uniform dose (EUD) to cancer cells was calculated for each treatment scenario. The therapeutic ratio (TR) was defined by comparing VCBT with a uniform dose radiotherapy plan in term of normal cell survival at the same level of cancer cell killing. Calculations of clinical impact were run twice assuming two different types of cancer cell density distributions in the cylindrical target volume: (1) a half-Gaussian or (2) a uniform distribution. Results: EUDs were weakly dependent on cylinder size, treatment length, and the prescription depth, but strongly dependent on the cancer cell distribution. TRs were strongly dependent on the cylinder size, treatment length, types of the cancer cell distributions, and the sensitivity of normal tissue. With a half-Gaussian distribution of cancer cells which populated at the vaginal mucosa the most, the EUDs were between 6.9 Gy × 4 and 7.8 Gy × 4, the TRs were in the range from (5.0){sup 4} to (13.4){sup 4} for the radiosensitive normal tissue depending on the cylinder size, treatment lengths, prescription depth, and dose as well. However, for a uniform cancer cell distribution, the EUDs were between 6.3 Gy × 4 and 7.1 Gy × 4, and the TRs were found to be between (1.4){sup 4} and (1.7){sup 4}. For the uniformly interspersed cancer and radio-resistant normal cells, the TRs were less than 1. The two VCBT prescription regimens were found to be equivalent in terms of EUDs and TRs. Conclusions: HDR VCBT strongly favors cylindrical target volume with the cancer cell distribution following its dosimetric trend. Assuming a half-Gaussian distribution of cancer cells, the HDR VCBT provides a considerable radiobiological advantage over the external beam radiotherapy (EBRT) in terms of sparing more normal tissues while maintaining the same level of cancer cell killing. But for the uniform cancer cell distribution and radio-resistant normal tissue, the radiobiology outcome of the HDR VCBT does not show an advantage over the EBRT. This study strongly suggests that radiation therapy design should consider the cancer cell distribution inside the target volume in addition to the shape of target.

61 RADIATION PROTECTION AND DOSIMETRY↗

TDD LoRa and Delta Encoding in Low-Power Networks of Environmental Sensor Arrays for Temperature and Deformation Monitoring

Abstract Densely distributed sensor networks can revolutionize environmental observations by providing real-time data with an unprecedented spatiotemporal resolution. However, field deployments often pose unique challenges in terms of power provisions and wireless connectivity. We present a framework for wirelessly connected distributed sensor arrays for near-surface temperature and/or deformation monitoring. Our research focuses on a novel time division duplex implementation of the LoRa protocol, enabling battery powered base stations and avoiding collisions within the network. In order to minimize transmissions and improve battery life throughout the network, we propose a dedicated delta encoding algorithm that utilizes the spatial and temporal similarity in the acquired data sets. We implemented the developed technologies in a AA battery powered hardware platform that can be used as a wireless data logger or base station, and we conducted an assessment of the power consumption. Without data compression, the projected battery life for a data logger is 4.74 years, and a wireless base stations can last several weeks or months depending on the amount of network traffic. The delta encoding algorithm can further improve this battery life with a factor of up to 3.50. Our results demonstrate the viability of the proposed methods for low-power environmental wireless sensor networks.

54 ENVIRONMENTAL SCIENCES↗

Quantitative and three-dimensional assessment of holdup material

Nuclear material deposited in equipment, transfer lines, and ventilation systems of a processing facility is usually referred to as holdup. Operators need to know the location and amount of holdup in their facility for radiation safety and material accountability. In this work, we propose to use an array of detectors co-axial to the inspected pipe to measure the holdup material. This method is implementable into an automated system capable of crawling on surfaces and pipes of various curvatures, which would enable faster, easier, and more accurate holdup safeguards measurements. We first demonstrated that the current holdup assay procedure could lead to a non-negligible bias in the estimate of special nuclear material mass, due to the simplified assumption of deposited geometry introduced by the Generalized Geometry Holdup (GGH) model. The new approach consists of imaging the inner holdup material by characterizing the detector array’s response and unfolding it from the measured light output. Our experimental proof of principle consists of three NaI(Tl) detectors surrounding an aluminum pipe containing two cesium-137 ( 137 Cs) sources. We derived the source distribution inside the pipe by first calculating the detector response matrix using a method adaptive to the surface geometry of the object containing the measured holdup material. Creating a matrix of the detector array’s measured counts, we then proceed to solve an inverse problem, resulting in an accurately located source position and activity distribution within the response matrix’s spatial resolution. Furthermore, we then developed a simulated model of the envisioned experimental setup, which accurately described both the activity and position of the source in 2D. Finally, we extended our model onto a discretized three-dimensional model of the system, encompassing 36 detectors. The model was simulated to measure the source distribution and activity of multiple sources in pipes of varied geometries, which could then be conveniently translated to a real-time holdup measurement protocol. For the 3D simulation of four different source geometries, the model accurately localized the source position in 3D, while the activity retained a maximum relative error of ±5.32%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dose reconstruction for real-time patient-specific dose estimation in CT

Purpose: Many recent computed tomography (CT) dose reduction approaches belong to one of three categories: statistical reconstruction algorithms, efficient x-ray detectors, and optimized CT acquisition schemes with precise control over the x-ray distribution. The latter category could greatly benefit from fast and accurate methods for dose estimation, which would enable real-time patient-specific protocol optimization. Methods: The authors present a new method for volumetrically reconstructing absorbed dose on a per-voxel basis, directly from the actual CT images. The authors’ specific implementation combines a distance-driven pencil-beam approach to model the first-order x-ray interactions with a set of Gaussian convolution kernels to model the higher-order x-ray interactions. The authors performed a number of 3D simulation experiments comparing the proposed method to a Monte Carlo based ground truth. Results: The authors’ results indicate that the proposed approach offers a good trade-off between accuracy and computational efficiency. The images show a good qualitative correspondence to Monte Carlo estimates. Preliminary quantitative results show errors below 10%, except in bone regions, where the authors see a bigger model mismatch. The computational complexity is similar to that of a low-resolution filtered-backprojection algorithm. Conclusions: The authors present a method for analytic dose reconstruction in CT, similar to the techniques used in radiation therapy planning with megavoltage energies. Future work will include refinements of the proposed method to improve the accuracy as well as a more extensive validation study. The proposed method is not intended to replace methods that track individual x-ray photons, but the authors expect that it may prove useful in applications where real-time patient-specific dose estimation is required.

60 APPLIED LIFE SCIENCES↗

SolarPlus-Optimizer v0.1

With the falling costs of solar arrays and battery storage and reduced reliability of the grid due to natural disasters, small-scale local generation and storage resources are beginning to proliferate. However, very few software options exist for integrated control of building loads, batteries and other distributed energy resources. The available software solutions on the market can force customers to adopt one particular ecosystem of products, thus limiting consumer choice, and are often incapable of operating independently of the grid during blackouts. In this software package, we present the "Solar+ Optimizer" (SPO), a control platform that provides demand flexibility, resiliency and reduced utility bills, built using open-source software. SPO employs Model Predictive Control (MPC) to produce real time optimal control strategies for the building loads and the distributed energy resources on site. SPO is designed to be vendor-agnostic, protocol-independent and resilient to loss of wide-area network connectivity. The software was evaluated in a real convenience store in northern California with on-site solar generation, battery storage and control of HVAC and commercial refrigeration loads. Preliminary tests showed price responsiveness of the building and cost savings of more than 10% in energy costs alone.

Prakash, AnandKrishnan↗

Solar+ Optimizer: A Model Predictive Control Optimization Platform for Grid Responsive Building Microgrids

With the falling costs of solar arrays and battery storage and reduced reliability of the grid due to natural disasters, small-scale local generation and storage resources are beginning to proliferate. However, very few software options exist for integrated control of building loads, batteries and other distributed energy resources. The available software solutions on the market can force customers to adopt one particular ecosystem of products, thus limiting consumer choice, and are often incapable of operating independently of the grid during blackouts. In this paper, we present the “Solar+ Optimizer” (SPO), a control platform that provides demand flexibility, resiliency and reduced utility bills, built using open-source software. SPO employs Model Predictive Control (MPC) to produce real time optimal control strategies for the building loads and the distributed energy resources on site. SPO is designed to be vendor-agnostic, protocol-independent and resilient to loss of wide-area network connectivity. The software was evaluated in a real convenience store in northern California with on-site solar generation, battery storage and control of HVAC and commercial refrigeration loads. Preliminary tests showed price responsiveness of the building and cost savings of more than 10% in energy costs alone.

14 SOLAR ENERGY↗

Spitzer Microlensing Parallax for OGLE-2016-BLG-1067: A Sub-Jupiter Orbiting an M Dwarf in the Disk

We report the discovery of a sub-Jupiter-mass planet orbiting beyond the snow line of an M dwarf most likely in the Galactic disk as part of the joint Spitzer and ground-based monitoring of planetary microlensing anomalies toward the Galactic bulge. Most of the microlensing parameters are strongly constrained by the light-curve modeling, and in particular there is a Spitzer-based measurement of the microlens parallax, π {sub E}. However, there are no caustic crossings, so the angular Einstein radius has only an upper limit based on the light-curve modeling alone. Additionally, the analysis leads us to identify eight degenerate configurations: the fourfold microlensing parallax degeneracy being doubled by a degeneracy in the caustic structure present at the level of the ground-based solutions. To calculate the physical parameters, and at the same time to break the parallax degeneracy, we make use of a series of arguments: the χ {sup 2} hierarchy, the Rich argument (stating that the small-parallax solution is more likely), and a prior Galactic model. The preferred configuration, favored by a likelihood ratio of at least 4000, is for a host at D{sub L}=3.73{sub −0.67}{sup +0.66} kpc with mass M{sub L}=0.30{sub −0.12}{sup +0.15} M{sub ⊙}, orbited by a Saturn-like planet with M{sub planet} =0.43{sub −0.17}{sup +0.21} M{sub Jup} at projected separation a{sub ⊥}=1.70{sub −0.39}{sup +0.38} au, about 2.1 times beyond the system snow line. Therefore, it adds to the growing population of sub-Jupiter planets orbiting beyond the snow line of M dwarfs discovered by microlensing. Based on the rules of the real-time protocol for the selection of events to be followed up with Spitzer, this planet will not enter the sample for measuring the Galactic distribution of planets.

79 ASTRONOMY AND ASTROPHYSICS↗

EMS and DMS Integration of the Coordinative Real-time Sub-Transmission Volt-Var Control Tool under High DER Penetration

This paper proposes an applicable approach to deploy the Coordinative Real-time Sub-Transmission Volt-Var Control Tool (CReST-VCT), and a holistic system integration framework considering both the energy management system (EMS) and distribution system management system (DMS). This provides an architectural basis and can serve as the implementation guideline of CReST-VCT and other advanced grid support tools, to co-optimize the operation benefits of DERs and assets in both transmission and distribution networks. Potential communication protocols for different physical domains of a real application is included. Performance and security issues are also discussed, along with specific considerations for field deployment. Finally, the paper presents a viable pathway for CReST-VCT and other advanced grid support tools, which could be integrated in an open-source standardized-based platform that supports distribution utilities.

Nguyen, Quan H.↗

Survival After Accidental Extrahepatic Distribution of Y90 Microspheres to the Mesentery During a Radioembolization Procedure

We present the acute management and outcome of a patient after an accidental mesenteric distribution of Y90 microspheres during radioembolization (RE). This report describes and highlights: (1) the incidence of a significant reflux during a RE session while injecting into a replaced right hepatic artery from the superior mesenteric artery, (2) the appearance of diffuse mesenteric Y90 distribution in bremsstrahlung-imaging, (3) the management protocol with the radiation protection agent amifostine, (4) the development of typical adverse effects in the expected time window, and (5) survival of the patient without long-term sequelae. This report should sensitize physicians to this particular problem and may help to avoid as well as manage similar radioembolization incidences.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric comparison of flattened and unflattened beams for stereotactic ablative radiotherapy of stage I non-small cell lung cancer

Purpose: To compare contribution and accuracy of delivery for two flattening filter free (FFF) beams of the nominal energy 6 and 10 MV and a 6 MV flattened beam for early stage lung cancer. Methods: For each of 11 patients with stage I nonsmall cell lung cancer three volumetric modulated arc therapy plans were prepared utilizing a 6 MV flattened photon beam (X6FF) and two nonflattened beams of nominal energy 6 and 10 MV (X6FFF, X10FFF). Optimization constraints were set to produce dose distributions that meet the criteria of the RTOG-0915 protocol. The radiation schedule used for plan comparison in all patients was 50 Gy in five fractions. Dosimetric parameters of planning target volume (PTV) and organs-at-risk and delivery times were assessed and compared. All plans were subject to verification using Delta{sup 4} unit (Scandidos, Sweden) and absolutely calibrated gafchromic films in a thorax phantom. Results: All plans had a qualitatively comparable outcome. Obtained dose distributions were conformal (CI < 1.17) and exhibited a steep dose fall-off outside the PTV. The ratio of monitor units for FFF versus FF plans in the authors' study ranged from 0.95 to 1.21 and from 0.93 to 1.25 for X6FFF/X6FF and X10FFF/X6FF comparisons, respectively. The ratio systematically increased with increasing size of the PTV (up to +25% for 150 cm{sup 3} PTV). Yet the integral dose to healthy tissue did not follow this trend. Comparison of cumulative dose volume histograms for a patient's body showed that X6FFF plans exhibit improved conformity and reduced the volume of tissue that received more than 50% of the prescription dose. Parameters related to dose gradient showed statistically significant improvement. CI{sub 50%}, CI{sub 60%}, CI{sub 80%}, and CI{sub 100%} were on average reduced by 4.6% (p < 0.001), 4.6% (p = 0.002), 3.1% (p = 0.002), and 1.2% (p = 0.039), respectively. Gradient measure was on average reduced by 4.2% (p < 0.001). Due to dose reduction in the surrounding lung tissue, the V{sub 20} {sub Gy} and V{sub 12.5} {sub Gy} were reduced by 5.5% (p = 0.002) and 4.5% (p < 0.001). These dosimetric improvements in the fall-off were not observed for the X10FFF plans. Differences in sparing of normal tissues were not found to be statistically significant for either of the two FFF beams. Mean beam-on times were 111 s (2SD = 11 s) for X10FFF, 128 s (2SD = 19 s) for X6FFF, and X6FF plans required on average 269 s (2SD = 71 s). While the mean dose rate was 1555 ± 264 and 1368 ± 63 MU/min, for X10FFF and X6FFF, plans using the conventional X6FF were delivered with the constant maximum dose rate of 600 MU/min. Verification of all plans showed acceptable and comparable results for all plans in homogeneous as well as heterogeneous phantoms. Mean GS (3%, 2 mm) using the Delta{sup 4} phantom were 98.9% (2SD = 3.2%), 99.2% (2SD = 2.3%), and 99.2% (2SD = 2.3%) for X6FFF, X6FF, and X10FFF modalities. Verification using a thorax phantom showed GS > 98% in all cases. Conclusions: The use of FFF beams for stereotactic radiation therapy of nonsmall cell lung cancer patients yielded dose distributions qualitatively comparable to flattened beams and significantly reduced treatment delivery time. Utilizing the X6FFF beam improved conformity of dose distribution. On the other hand, X10FFF beam offered a slight improvement in treatment efficiency, and lower skin and peripheral dose. All effects were relatively small.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Broadly Adaptive Array of Dose-Constraint Templates for Planning of Intensity-Modulated Radiation Therapy for Advanced T-Stage Nasopharyngeal Carcinoma

Purpose: To develop and validate adaptive dose-constraint templates in intensity-modulated radiotherapy (IMRT) planning for advanced T-stage nasopharyngeal carcinoma (NPC). Method and Materials: Dose-volume histograms of clinically approved plans for 20 patients with advanced T-stage NPC were analyzed, and the pattern of distribution in relation to the degree of overlap between targets and organs at risk (OARs) was explored. An adaptive dose constraint template (ADCT) was developed based on the degree of overlap. Another set of 10 patients with advanced T-stage NPC was selected for validation. Results of the manual arm optimization protocol and the ADCT optimization protocol were compared with respect to dose optimization time, conformity indices, multiple-dose end points, tumor control probability, and normal tissue complication probability. Results: For the ADCT protocol, average time required to achieve an acceptable plan was 9 minutes, with one optimization compared with 94 minutes with more than two optimizations of the manual arm protocol. Target coverage was similar between the manual arm and ADCT plans. A more desirable dose distribution in the region of overlap between planning target volume and OARs was achieved in the ADCT plan. Dose end points of OARs were similar between the manual arm and ADCT plans. Conclusions: With the developed ADCT, IMRT treatment planning becomes more efficient and less dependent on the planner's experience on dose optimization. The developed ADCT is applicable to a wide range of advanced T-stage NPC treatment and has the potential to be applied in a broader context to IMRT planning for other cancer sites.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Clinical Development of Molecularly Targeted Agents in Combination With Radiation Therapy: A Pharmaceutical Perspective

Summary: This paper explores historical and current roles of pharmaceutical industry sponsorship of clinical trials testing radiation therapy combinations with molecularly targeted agents and attempts to identify potential solutions to expediting further combination studies. An analysis of clinical trials involving a combination of radiation therapy and novel cancer therapies was performed. Ongoing and completed trials were identified by searching the (clinicaltrials.gov) Web site, in the first instance, with published trials of drugs of interest identified through American Society of Clinical Oncology, European CanCer Organisation/European Society for Medical Oncology, American Society for Radiation Oncology/European Society for Therapeutic Radiology and Oncology, and PubMed databases and then cross-correlated with (clinicaltrials.gov) protocols. We examined combination trials involving radiation therapy with novel agents and determined their distribution by tumor type, predominant molecular mechanisms examined in combination to date, timing of initiation of trials relative to a novel agent's primary development, and source of sponsorship of such trials. A total of 564 studies of targeted agents in combination with radiation therapy were identified with or without concomitant chemotherapy. Most studies were in phase I/II development, with only 36 trials in phase III. The tumor site most frequently studied was head and neck (26%), followed by non-small cell lung cancer. Pharmaceutical companies were the sponsors of 33% of studies overall and provided support for only 16% of phase III studies. In terms of pharmaceutical sponsorship, Genentech was the most active sponsor of radiation therapy combinations (22%), followed by AstraZeneca (14%). Most radiation therapy combination trials do not appear to be initiated until after drug approval. In phase III studies, the most common (58%) primary endpoint was overall survival. Collectively, this analysis suggests that such trials are not given priority by pharmaceutical companies. The potential reasons for this and some challenges and possible solutions are discussed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Toward a clinical application of ex situ boron neutron capture therapy for lung tumors at the RA-3 reactor in Argentina

Purpose: Many types of lung tumors have a very poor prognosis due to their spread in the whole organ volume. The fact that boron neutron capture therapy (BNCT) would allow for selective targeting of all the nodules regardless of their position, prompted a preclinical feasibility study of ex situ BNCT at the thermal neutron facility of RA-3 reactor in the province of Buenos Aires, Argentina. (L)-4p-dihydroxy-borylphenylalanine fructose complex (BPA-F) biodistribution studies in an adult sheep model and computational dosimetry for a human explanted lung were performed to evaluate the feasibility and the therapeutic potential of ex situ BNCT. Methods: Two kinds of boron biodistribution studies were carried out in the healthy sheep: a set of pharmacokinetic studies without lung excision, and a set that consisted of evaluation of boron concentration in the explanted and perfused lung. In order to assess the feasibility of the clinical application of ex situ BNCT at RA-3, a case of multiple lung metastases was analyzed. A detailed computational representation of the geometry of the lung was built based on a real collapsed human lung. Dosimetric calculations and dose limiting considerations were based on the experimental results from the adult sheep, and on the most suitable information published in the literature. In addition, a workable treatment plan was considered to assess the clinical application in a realistic scenario. Results: Concentration-time profiles for the normal sheep showed that the boron kinetics in blood, lung, and skin would adequately represent the boron behavior and absolute uptake expected in human tissues. Results strongly suggest that the distribution of the boron compound is spatially homogeneous in the lung. A constant lung-to-blood ratio of 1.3 ± 0.1 was observed from 80 min after the end of BPA-F infusion. The fact that this ratio remains constant during time would allow the blood boron concentration to be used as a surrogate and indirect quantification of the estimated value in the explanted healthy lung. The proposed preclinical animal model allowed for the study of the explanted lung. As expected, the boron concentration values fell as a result of the application of the preservation protocol required to preserve the lung function. The distribution of the boron concentration retention factor was obtained for healthy lung, with a mean value of 0.46 ± 0.14 consistent with that reported for metastatic colon carcinoma model in rat perfused lung. Considering the human lung model and suitable tumor control probability for lung cancer, a promising average fraction of controlled lesions higher than 85% was obtained even for a low tumor-to-normal boron concentration ratio of 2. Conclusions: This work reports for the first time data supporting the validity of the ovine model as an adequate human surrogate in terms of boron kinetics and uptake in clinically relevant tissues. Collectively, the results and analysis presented would strongly suggest that ex situ whole lung BNCT irradiation is a feasible and highly promising technique that could greatly contribute to the treatment of metastatic lung disease in those patients without extrapulmonary spread, increasing not only the expected overall survival but also the resulting quality of life.

60 APPLIED LIFE SCIENCES↗

Chapter 2: Commercial and Industrial Lighting Evaluation Protocol. The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures

The Commercial and Industrial Lighting Evaluation Protocol (the protocol) describes methods to account for gross energy savings resulting from the programmatic installation of efficient lighting equipment in large populations of commercial, industrial, and other nonresidential facilities. This protocol does not address savings resulting from changes in codes and standards, or from education and training activities. A separate Uniform Methods Project (UMP) protocol, Chapter 3: Commercial and Industrial Lighting Controls Evaluation Protocol, addresses methods for evaluating savings resulting from lighting control measures such as adding time clocks, tuning energy management system commands, and adding occupancy sensors.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Atomic-ensemble-based quantum repeater against general polarization and phase noise

We present a quantum repeater architecture based on atomic ensembles, which is free of polarization and phase noise. With only simple optical elements, we can obtain the uncorrupted entanglement in the noisy channel. Even if the channel suffers from the general polarization and phase noise, the fidelity of transmitted qubits in our protocol can be stable and have no dependence on the noise parameter, which is a significant advantage compared with previous protocols. Moveover, we can even improve the fidelity by using time delayers. The proposed quantum repeater is feasible and useful in the long-distance quantum entanglement distribution and may be promising in other quantum-information applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗