Search NASASearch

SEARCH · Search NASA

Results for “Doppler effect”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

New ion trap for frequency standard applications

A novel linear ion trap was designed, which permits storage of a large number of ions with reduced susceptibility to the second-order Doppler effect caused by the RF confining fields. This new trap should store about 20 times the number of ions as a conventional RF trap with no corresponding increase in second-order Doppler shift from the confining field. In addition, the sensitivity of this shift to trapping parameters, i.e., RF voltage, RF frequency, and trap size, is greatly reduced.

Prestage, J. D.

Linear ion trap for second-order Doppler shift reduction in frequency standard applications

The authors have designed and are presently testing a novel linear ion trap that permits storage of a large number of ions with reduced susceptibility to the second-order Doppler effect caused by the RF confining fields. This new trap should store about 20 times the number of ions as a conventional RF trap with no corresponding increase in second-order Doppler shift from the confining field. In addition, the sensitivity of this shift to trapping parameters, i.e., RF voltage, RF frequency, and trap size, is greatly reduced. The authors have succeeded in trapping mercury ions and xenon ions in the presence of helium buffer gas. Trap times as long as 2000 s have been measured.

Prestage, John D.

Coherent Laser Instrument Would Measure Range and Velocity

A proposed instrument would project a narrow laser beam that would be frequency-modulated with a pseudorandom noise (PN) code for simultaneous measurement of range and velocity along the beam. The instrument performs these functions in a low mass, power, and volume package using a novel combination of established techniques. Originally intended as a low resource- footprint guidance sensor for descent and landing of small spacecraft onto Mars or small bodies (e.g., asteroids), the basic instrument concept also lends itself well to a similar application guiding aircraft (especially, small unmanned aircraft), and to such other applications as ranging of topographical features and measuring velocities of airborne light-scattering particles as wind indicators. Several key features of the instrument s design contribute to its favorable performance and resource-consumption characteristics. A laser beam is intrinsically much narrower (for the same exit aperture telescope or antenna) than a radar beam, eliminating the need to correct for the effect of sloping terrain over the beam width, as is the case with radar. Furthermore, the use of continuous-wave (CW), erbium-doped fiber lasers with excellent spectral purity (narrow line width) permits greater velocity resolution, while reducing the laser s power requirement compared to a more typical pulsed solid-state laser. The use of CW also takes proper advantage of the increased sensitivity of coherent detection, necessary in the first place for direct measurement of velocity using the Doppler effect. However, measuring range with a CW beam requires modulation to "tag" portions of it for time-of-flight determination; typically, the modulation consists of a PN code. A novel element of the instrument s design is the use of frequency modulation (FM) to accomplish both the PN-modulation and the Doppler-bias frequency shift necessary for signed velocity measurements. This permits the use of a single low-power waveguide electrooptic phase modulator, while simultaneously mitigating the effects of speckle as a noise source in the coherent detection.

Chang, Daniel

New ion trap for atomic frequency standard applications

A novel linear ion trap that permits storage of a large number of ions with reduced susceptibility to the second-order Doppler effect caused by the radio frequency (RF) confining fields has been designed and built. This new trap should store about 20 times the number of ions a conventional RF trap stores with no corresponding increase in second-order Doppler shift from the confining field. In addition, the sensitivity of this shift to trapping parameters, i.e., RF voltage, RF frequency, and trap size, is greatly reduced.

Prestage, J. D.

Discovery of a periodic pulsating binary X-ray source in Hercules from Uhuru.

We have discovered a new pulsating X-ray source with a 1.24-sec period in the constellation Hercules. Analysis of 5 months of data has shown the existence of periodic variations in the intensity of the source and correlated sinusoidal variations in the period of the 1.24-sec pulsations. As in the case of the pulsating X-ray source Cen X-3, we interpret this effect as due to an occulting binary system, with the intensity changes due to occultation of the X-ray source by its companion and with the sinusoidal variations in the period of the 1.24-sec pulsations due to the Doppler effect. In addition, we have observed a longer-time scale cycle in which the source is bright and pulsing for approximately 9 days during which we can observe the 1.7-day occulting, followed by approximately 27 days during which the source is not detected above background on individual 20-sec scans.

Tananbaum, H.

Advanced research to qualify man for long term weightlessness.

NASA is in the process of conducting a broad program of research and development of technology to qualify, support, and permit the successful use of man in long-term space flight. The technological tasks include human engineering, extravehicular engineering, life support, and human research to assess the effect of space stresses on human physiology and psychology. Various testing techniques that are being used may have future relevance to world health. These include a biocybernetic approach to the study of cardiovascular stresses, measurement of blood flow by means of the Doppler effect, and a device for simulating radiation dosages similar to those produced in solar flares. The planned program includes a study of both humans and animals.

Jones, W. L.

Evidence for the binary nature of Centaurus X-3 from Uhuru X-ray observations.

Analysis of data spanning a year of observations of the pulsating X-ray source Cen X-3 from Uhuru has revealed the existence of periodic variations in intensity of the source and correlated sinusoidal variations in the period of the 4.8-sec pulsations. We interpret this effect as due to an occulting binary system. The changes in intensity are then due to occultation of the X-ray source by a large massive companion, and the sinusoidal variations in the period of the 4.8-sec pulsations are due to Doppler effect. Physical parameters for the system are derived, and evidence for the existence and nature of an extended atmosphere surrounding the massive occulting object is discussed.

Schreier, E.

Visualizing ultrasound through computational modeling

The Doppler Ultrasound Hematocrit Project (DHP) hopes to find non-invasive methods of determining a person s blood characteristics. Because of the limits of microgravity and the space travel environment, it is important to find non-invasive methods of evaluating the health of persons in space. Presently, there is no well developed method of determining blood composition non-invasively. This projects hopes to use ultrasound and Doppler signals to evaluate the characteristic of hematocrit, the percentage by volume of red blood cells within whole blood. These non-invasive techniques may also be developed to be used on earth for trauma patients where invasive measure might be detrimental. Computational modeling is a useful tool for collecting preliminary information and predictions for the laboratory research. We hope to find and develop a computer program that will be able to simulate the ultrasound signals the project will work with. Simulated models of test conditions will more easily show what might be expected from laboratory results thus help the research group make informed decisions before and during experimentation. There are several existing Matlab based computer programs available, designed to interpret and simulate ultrasound signals. These programs will be evaluated to find which is best suited for the project needs. The criteria of evaluation that will be used are 1) the program must be able to specify transducer properties and specify transmitting and receiving signals, 2) the program must be able to simulate ultrasound signals through different attenuating mediums, 3) the program must be able to process moving targets in order to simulate the Doppler effects that are associated with blood flow, 4) the program should be user friendly and adaptable to various models. After a computer program is chosen, two simulation models will be constructed. These models will simulate and interpret an RF data signal and a Doppler signal.

Guo, Theresa W.

Ultra-stable Hg(+) trapped ion frequency standard

A fieldable trapped ion frequency standard based on Hg-199(+) ions confined in a hybrid rf/dc linear ion trap is developed. This trap permits storage of large numbers of ions with reduced susceptibility to the second-order Doppler effect caused by the rf confining fields. In preliminary measurements a stability of 2 to 3 x 10(exp -15) was obtained for 10000 second averaging times. These measurements were carried out with a 120 mHz wide atomic resonance line for the 40.5 GHz clock transition with a second order Doppler shift from the rf trapping field of 6 x 10(exp -13).

Prestage, John D.

A modified Lorentz theory as a test theory of special relativity

Attention has been given recently to a modified Lorentz theory (MLT) that is based on the generalized Galilean transformation. Some explicit formulas within the framework of MLT, dealing with the one-way velocity of light, slow-clock transport, and the Doppler effect are derived. A number of typical experiments are analyzed on this basis. Results indicate that the empirical equivalence between MLT and special relativity is still maintained to second order terms. The results of previous works that predict that the MLT might be distinguished from special relativity at the third order by Doppler centrifuge tests capable of a fractional frequency detection threshold of 10 to the -15th are confirmed.

Chang, T.

Laser Doppler And Range Systems For Spacecraft

Report discusses two types of proposed laser systems containing active transponders measuring distance (range) and line-of-sight velocity (via Doppler effect) between deep space vehicle and earth-orbiting satellite. Laser system offers diffraction advantage over microwave system. Delivers comparable power to distant receiver while using smaller transmitting and receiving antennas and less-powerful transmitter. Less subject to phase scintillations caused by passage through such inhomogeneous media as solar corona. One type of system called "incoherent" because range and Doppler measurements do not require coherence with laser carrier signals. Other type of system called "coherent" because successful operation requires coherent tracking of laser signals.

Kinman, P. W.

Channel simulation to facilitate mobile-satellite communications research

The mobile-satellite-service channel simulator, which is a facility for an end-to-end hardware simulation of mobile satellite communications links is discussed. Propagation effects, Doppler, interference, band limiting, satellite nonlinearity, and thermal noise have been incorporated into the simulator. The propagation environment in which the simulator needs to operate and the architecture of the simulator are described. The simulator is composed of: a mobile/fixed transmitter, interference transmitters, a propagation path simulator, a spacecraft, and a fixed/mobile receiver. Data from application experiments conducted with the channel simulator are presented; the noise converison technique to evaluate interference effects, the error floor phenomenon of digital multipath fading links, and the fade margin associated with a noncoherent receiver are examined. Diagrams of the simulator are provided.

Davarian, Faramaz

Estimations of model parameters for gravity wave spectra observed by MST radar

The general theory of MST radar observations of gravity wave spectra is developed. This effort extends the previous results to include anisotropy and Doppler effects for the spectra, as well as the consequences for the multibeam configuration. The relationships between the observed one- or two-dimensional spectra for the line-of-sight velocity in the gravity wave spectra are derived. Expressions for cross spectra, as well as covariances between velocities observed on different beams, are computed. Using these results, studies are carried out to show how model parameters for gravity wave spectra can be estimated from the observed quantities. Model parameters include the variance, power law indices, anisotropy parameters, Doppler parameters, mean scale sizes, etc. Cases with different numbers of beams are investigated.

Scheffler, A. O.

Method and system of doppler correction for mobile communications systems

Doppler correction system and method comprising receiving a Doppler effected signal comprising a preamble signal (32). A delayed preamble signal (48) may be generated based on the preamble signal (32). The preamble signal (32) may be multiplied by the delayed preamble signal (48) to generate an in-phase preamble signal (60). The in-phase preamble signal (60) may be filtered to generate a substantially constant in-phase preamble signal (62). A plurality of samples of the substantially constant in-phase preamble signal (62) may be accumulated. A phase-shifted signal (76) may also be generated based on the preamble signal (32). The phase-shifted signal (76) may be multiplied by the delayed preamble signal (48) to generate an out-of-phase preamble signal (80). The out-of-phase preamble signal (80) may be filtered to generate a substantially constant out-of-phase preamble signal (82). A plurality of samples of the substantially constant out-of-phase signal (82) may be accumulated. A sum of the in-phase preamble samples and a sum of the out-of-phase preamble samples may be normalized relative to each other to generate an in-phase Doppler estimator (92) and an out-of-phase Doppler estimator (94).

Georghiades, Costas N.

Doppler Broadening and Other Temperature Effects

In this paper I attempt to document what I have learned and still remember about temperature effects, particularly Doppler broadening, on nuclear data, as it applies to ENDF formatted data. My focus is on the SIGMA1 method of Doppler broadening that I developed over 50 years ago. However, I do realize that there are currently many different methods used in computer codes, and I have tried to keep my discussion general as it applies to ALL of these methods. In particular, ALL of the MYTHS I describe below apply to all Doppler broadening methods: they all solve the parabolic diffusion equation in spherical geometry in (speed, reaction rate) versus temperature. These methods differ only in how the cross section is represented. So, at 85 years old here is what I still remember.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS

Investigation and study of a multi-aperture antenna system final report, 1 jan. - 1 apr. 1964

This investigation was concerned with a multiple aperture adaptive antenna system for application to receiving telemetered data from remote space vehicles or satellites. The primary criterion for determining the feasibility of such a system has been economic considerations, but of necessity many physical constraints imposed on both a single antenna and a multiple aperture system have been evaluated. These include such factors as acquisition and combining of signals, look angle, shadowing, propagation influences system spatial bandwidth, collimation, interference, doppler effects, reliability, and noise. Specific conclusions have been made for a system operating at a frequency of 2 Gc, but the system model adopted allows quick evaluation at other frequencies. At a frequency of 2Gc, the crossover point between a single antenna or a multiple aperture configuration occurs for an 85 foot reflector. However this transition region is not critical. For lunar range communications a single antenna appears to be the most economical, whereas at interplanetary ranges aperture equivalents of around 400 feet are required and achieved by arraying eight 142 foot antennas.

TELEMETRY