Search NASA⌕ Search

SEARCH · Search NASA

Results for “Doppler spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Wavelength modulation laser-induced fluorescence for plasma characterization

Laser-Induced Fluorescence (LIF) spectroscopy is an essential tool for probing ion and atom velocity distribution functions (VDFs) in complex plasmas. VDFs carry information about the kinetic properties of species that is critical for plasma characterization. Accurate interpretation of these functions is challenging due to factors such as multicomponent distributions, broadening effects, and background emissions. Our research investigates the use of Wavelength Modulation (WM) LIF to enhance the sensitivity of VDF measurements. Unlike standard Amplitude Modulation (AM) methods, WM–LIF measures the derivative of the LIF signal. This approach makes variations in VDF shape more pronounced. VDF measurements with WM–LIF were investigated with both numerical modeling and experimental measurements. The developed model enables the generation of both WM and AM signals, facilitating comparative analysis of fitting outcomes. Experiments were conducted in a weakly collisional argon plasma with magnetized electrons and non-magnetized ions. Measurements of the argon ion VDFs employed a narrow-band tunable diode laser, which scanned the 4p 4 D 7/2 –3d 4 F 9/2 transition centered at 664.553 nm in vacuum. A lock-in amplifier detected the second harmonic WM signal, which was generated by modulating the laser wavelength with an externally controlled piezo-driven mirror of the diode laser. Finally, our findings indicate that the WM–LIF signal is more sensitive to fitting parameters, allowing for better identification of VDF parameters such as the number of distribution components, their temperatures, and velocities. In addition, WM–LIF can serve as an independent method to verify AM measurements and is particularly beneficial in environments with substantial light noise or background emissions, such as those involving thermionic cathodes and reflective surfaces.

47 OTHER INSTRUMENTATION↗

Lifetime measurements of excited states in 15 O

The CNO cycle is the main energy source in stars more massive than our Sun, it defines the energy production and the cycle time that lead to the lifetime of massive stars, and it is an important tool for the determination of the age of globular clusters. One of the largest uncertainties in the CNO chain of reactions comes from the uncertainty in the 14 N(p,γ) 15 O reaction rate. This uncertainty arises predominantly from the uncertainty in the lifetime of the subthreshold state in 15 O at E x = 6792 keV. Previous measurements of this state's lifetime are significantly discrepant. Here, we report on a new lifetime measurement of this state, as well as the excited states in 15 O at E x = 5181 keV and E x = 6172 keV, populated via the 14 N(p,γ) 15 O reaction at proton energies of E p = 1020 keV and E p = 1570 keV. Furthermore, the lifetimes have been determined with the Doppler-Shift Attenuation Method (DSAM) with three separate, nitrogen-implanted targets with Mo, Ta, and W backing. We obtained lifetimes from the weighted average of the three measurements, allowing us to account for systematic differences between the backing materials. For the 6792 keV state, we obtained a τ = 0.6 ± 0.4 fs. To provide cross-validation of our method, we measured the known lifetimes of the states at 5181 and 6172 keV to be τ = 7.5 ± 3.0 and τ = 0.7 ± 0.5 fs, respectively, in good agreement with previous measurements.

6 ≤ A ≤ 19↗

Coincidence Doppler Broadening Analysis Program

A graphical user interface (GUI) that helps analyze data from coincidence Doppler broadening positron annihilation spectroscopy. It is a quick tool to rapidly reduce large data and conveniently analyze multiple datasets.

Watkins, JosephM.↗

Dissemination of information about the technologies of the Vision Research Lab through the World Wide Web

The Vision Research Lab at NASA John Glenn Research Center is headed by Dr. Rafat Ansari. Dr. Ansari and other researchers have developed technologies that primarily use laser and fiber optics to non-invasively detect different ailments and diseases of the eye. One of my goals as a LERCIP intern and ACCESS scholar for the 2004 summer is to inform other NASA employees, researchers and the general public about these technologies through the development of a website. The website incorporates the theme that the eye is a window to the body. Thus by investigating the processes of the eye, we can better understand and diagnosis different ailments and diseases. These ailments occur in not only earth bound humans, but astronauts as well as a result of exposure to elevated levels of radiation and microgravity conditions. Thus the technologies being developed at the Vision Research Lab are invaluable to humans on Earth in addition to those astronauts in space. One of my first goals was to research the technologies being developed at the lab. The first several days were spent immersing myself in the various articles, journals and reports about the theories behind Dynamic Light Scattering, Laser Doppler Flowmetry, Autofluoresence, Raman Spectroscopy, Polarimetry and Oximetry. Interviews with the other researchers proved invaluable to help understand these theories as well gain hands on experience with the devices being developed using these technologies. The rest of the Vision Research Team and I sat down and discussed how the overall website should be presented. Combining this information with the knowledge of the theories and applications of the hardware being developed, I worked out different ideas to present this information. I quickly learned Paint Shop Pro 8 and FrontPage 2002, as well as using online tutorials and other resources to help design an effective website. The Vision Research Lab website incorporates the anatomy and physiology of the eye, different diseases that affect the eye and the technologies being develop at the lab to help diagnosis these diseases. It also includes background information on Dr. Ansari as well as other researchers involved in the lab and it includes segments on patents, awards and achievements. There are links to help viewers navigate to internal and external websites to further investigate different ideas and hrther understand the implications of these technologies at being developed.

Dorais, Christopher M.↗

Measurement and analysis of the Doppler broadened energy spectra of gamma radiation originating from the annihilation of positrons incident on clean and adsorbate-covered surfaces

We present measurements and theoretical modeling demonstrating the capability of coincidence Doppler broadened (CDB) annihilation gamma spectroscopy to provide element-specific information from the topmost atomic layer of surfaces. Our measurements show that the energy spectra of Doppler-shifted annihilation gamma photons emitted following the annihilation of positrons from the topmost atomic layers of clean and adsorbate covered surfaces of gold (Au), silver (Ag) and copper (Cu) differ significantly. The shape of the Doppler-broadened gamma spectrum, as analyzed using ratio curves, indicates that the elemental composition of the surface can still be identified despite contributions from positronium annihilation and a significant reduction in core electron annihilation. We estimate the chemical composition of the various probed surfaces by modeling the ratios of the measured Doppler spectra with respect to the Doppler spectra from a clean Cu surface using a linear combination of calculated ratio curves. The fitting of the experimental ratio curves was used to obtain an estimate of the elemental composition of Cu surfaces with sulfur segregation, oxygen adsorption, a thin film of Selenium (Se), and a single layer of graphene (SLG). A similar analysis was performed on the Ag surface with environmental adsorbates, the same surface after argon ion sputtering, as well as a sputter cleaned Au surface. The surface compositions obtained from the analysis of the CDB data were compared to the compositions obtained using positron annihilation induced Auger electron spectroscopy (PAES). Our results show that CDB can detect, identify, and quantify, sub-monolayer adsorbates and a single atomic layer deposited on metal substrates.

Lotfimarangloo, Sima [Univ. of Texas, Arlington, T↗

TOI 540 b: A Planet Smaller than Earth Orbiting a Nearby Rapidly Rotating Low-mass Star

We present the discovery of TOI 540 b, a hot planet slightly smaller than Earth orbiting the low-mass star 2MASS J05051443-4756154. The planet has an orbital period of P = 1.239149 days (±170 ms) and a radius of r=0.903±0.052R{sub ⊕}, and is likely terrestrial based on the observed mass–radius distribution of small exoplanets at similar insolations. The star is 14.008 pc away and we estimate its mass and radius to be M=0.159±0.014 M{sub ⊙} and R=0.1895±0.0079R{sub ⊙}, respectively. The star is distinctive in its very short rotational period of P{sub rot}=17.4264±0.0094 hr and correspondingly small Rossby number of 0.007 as well as its high X-ray-to-bolometric luminosity ratio of L{sub X}/L{sub bol}=0.0028 based on a serendipitous XMM-Newton detection during a slew operation. This is consistent with the X-ray emission being observed at a maximum value of L{sub X}/L{sub bol}≃10{sup −3} as predicted for the most rapidly rotating M dwarfs. TOI 540 b may be an alluring target to study atmospheric erosion due to the strong stellar X-ray emission. It is also among the most accessible targets for transmission and emission spectroscopy and eclipse photometry with the James Webb Space Telescope, and may permit Doppler tomography with high-resolution spectroscopy during transit. This discovery is based on precise photometric data from the Transiting Exoplanet Survey Satellite and ground-based follow-up observations by the MEarth team.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Defect Characterization Using Positron Annihilation Spectroscopy on Laser-Ablated Surfaces

In recent years, short, pulsed laser ablation has been gaining popularity for machining small-scale test geometries from bulk samples and for efficient serial sectioning. These laser-based techniques are being added to the toolbox in material science, which makes it necessary to understand the changes in the material that occur from the laser–material interaction. Positron annihilation spectroscopy is a unique, nondestructive technique to investigate small defects in materials difficult to investigate by other tools. In this work, Doppler broadening and positron lifetime annihilation spectroscopy are utilized to help quantify the damage in materials treated with short, pulsed lasers. Using a femtosecond laser on single crystal silicon, this manuscript shows that clusters of vacancy-like defects and small voids increase systematically with laser power. Lastly, the damage induced by the laser can also reach to micrometer depths.

36 MATERIALS SCIENCE↗

Role of Tensile Stress in DNA Nanoresonators for Epigenetic Studies

The evaluation of epigenetic features such as DNA methylation is becoming increasingly important in many biochemical processes like gene expression and transcription as well as in several diseases like schizophrenia or diabetes. Here, in this work, we report that self-assembled nanomechanical resonators entirely composed of DNA molecules can be used to explore gross changes in DNA methylation levels (0–25–50%), while careful control of tensile stress is needed to reduce the variability of resonance frequency for rigorous quantification. The effect of the tensile stress retained by the suspended DNA nanoresonators on the application of the technique is extensively explored using a combination of laser Doppler vibrometry and atomic force spectroscopy. DNA nanoresonators are real-time, label-free sensors and could avoid chemical functionalization and sample amplification. Therefore, they may represent in the future a key complementary routine tool for global DNA methylation analysis needed to evaluate the consequences of environmental stresses on the human genome.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluation of a Method to Retrieve Temperature and Wind Velocity Profiles of the Venusian Nightside Mesosphere from Mid-Infrared CO2 Absorption Line Observed by Heterodyne Spectroscopy

We evaluated a method for retrieving vertical temperature and Doppler wind velocity profiles of the Venusian nightside mesosphere from the CO2 absorption line resolved by mid-infrared heterodyne spectroscopy. The achievable sensitive altitude and retrieval accuracy were derived with multiple model spectra generated from various temperature and wind velocity profiles with several noise levels. The temperature profiles were retrieved at altitudes of 70–100 km with a vertical resolution of 5 km and a retrieval accuracy of ±15 K. The wind velocity was also retrieved at an altitude of approximately 85 km with a vertical resolution of 10 km and a retrieval accuracy of ± 25–50 m/s. In addition, we studied an event and applied our method to spectra obtained by the HIPWAC instrument attached to the NASA/IRTF 3-m telescope on May 19–22, 2012. Retrieved wind velocities in a latitude of 33° S at 3:00 LT were interpreted as subsolar-to-antisolar (SS-AS) flows at altitudes of 84 ±6 km and 94 ±7 km, and they were stronger than expected. This result suggested that the transition between the retrograde super rotational zonal (RSZ) wind and SS-AS flow may occur at altitudes below 90 km which previously was predicted to be the transition region. This work provides a basis for our analysis of further observations obtained by a mid-infrared heterodyne spectrometer MILAHI attached to the Tohoku University 60-cm telescope at Haleakalā, Hawaii.

Venus↗

Multi-delay coherence imaging spectroscopy optimized for ion temperature measurements in the divertor plasma of the Wendelstein 7-X stellarator

A new coherence imaging spectroscopy (CIS) diagnostic optimized to measure the C 2+ impurity ion temperature T i spatial distribution in the divertor plasma of the W7-X stellarator is designed, tested, and validated. Using CIS to obtain T i in the edge of magnetically confined plasmas has historically been challenging because Doppler broadening and Zeeman splitting have comparable effects on the shape of spectral emission lines. To distinguish between these two mechanisms, a novel approach to birefringent crystal design is employed to minimize the diagnostic’s sensitivity to Zeeman splitting. The recently developed pixelated multi-delay CIS approach is also used to obtain four times as much spectral information as traditional CIS approaches. The T i -optimized CIS diagnostic is validated in a long-pulse W7-X plasma by comparison with a high-resolution spectrometer whose sightlines overlap with the CIS field of view. The CIS and spectrometer T i profiles have the same shape and agree to within 10% on average and 25% in the worst case. Images of the T i distribution near the divertor show toroidally elongated bands aligned with the magnetic field, with T i ranging between 10 and 40 eV.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Gallium vacancy formation in oxygen annealed β-Ga 2 O 3

Here, the formation and character of gallium vacancies (V Ga ) and their complexes in near surface and bulk regions of single crystal β-Ga 2 O 3 were explored using unintentionally doped single crystals grown by the Czochralski method. As-grown and O 2 annealed (up to 1550 °C) samples were investigated using positron annihilation spectroscopy (PAS) to study the top 0.05–6 μm, and also current–voltage measurements and infrared (IR) spectroscopy, with hydrogenated samples to probe V Ga , to study the bulk. After annealing in O 2 > 1000 °C, the β-Ga 2 O 3 resistivity begins increasing, up to ~10 9 Ω cm for 1550 °C treatment, with the top 0.5 mm being many orders of magnitude more resistive. PAS measurements of the top 6 μm (S values) and very near surface 200 nm (diffusion length, L) indicate differential behavior as a function of peak annealing temperature. At least four temperature regimes of behavior are described. V Ga are present in the bulk after growth, but considerable changes occur upon annealing at a temperature ≈1000 °C, where L and S decrease simultaneously, suggesting an increasing defect concentration (L) but a decreasing defect volume (S). Annealing at a temperature ≈1400 °C increases S again, showing an increasing volume concentration of V Ga , with IR absorption showing a large signature of V Ga -2H, indicative of increased V Ga formation that was not present when annealing at a temperature ≈1000 °C. These results suggest that defect changes from annealing in oxygen are depth dependent, and that V Ga configuration may not be the same near the oxygen-exposed surface of the sample and in the bulk.

74 ATOMIC AND MOLECULAR PHYSICS↗

Titanium alloy response sensitivity to variations in spectral reconstructions of National Ignition Facility xenon line-emission x-ray sources

Thermomechanical shock experiments on the National Ignition Facility (NIF) aim to study high strain rate dynamic material response. In such experiments, the NIF laser is used to generate high fluence x-ray emission sources, which irradiate material samples of interest. Under sufficiently high x-ray energy deposition, thermomechanical impulses are generated in the materials. While it is known that the characteristics of x-ray generated impulses vary as a function of incident x-ray spectra, it remains unclear how spectral assumptions and uncertainties in NIF spectral reconstructions affect our interpretation of impulsive loading. Here, in this paper, we simulate the response of a standard titanium alloy baseline sample to synthetic analytically derived and measured NIF xenon line-emission x-ray sources with a radiation hydrodynamics code. We vary the source spectral characteristics based on different source reconstruction techniques to understand the resulting variation in baseline sample response and compare the simulated response with experimental results. We find that the response is highly sensitive to assumptions made about the spectral contents and that knowledge of spectral uncertainties bounds our understanding of the resulting material response. The results of this effort help to extend our ability to use baseline material samples to extract quantitative properties from x-ray experiments on the NIF.

Alloys↗

A new mechanism for void-cascade interaction from nondestructive depth-resolved atomic-scale measurements of ion irradiation–induced defects in Fe

The nondestructive investigation of single vacancies and vacancy clusters in ion-irradiated samples requires a depth-resolved probe with atomic sensitivity to defects. The recent development of short-pulsed positron beams provides such a probe. Here, we combine depth-resolved Doppler broadening and positron annihilation lifetime spectroscopies to identify vacancy clusters in ion-irradiated Fe and measure their density as a function of depth. Despite large concentrations of dislocations and voids in the pristine samples, positron annihilation measurements uncovered the structure of vacancy clusters and the change in their size and density with irradiation dose. When combined with transmission electron microscopy measurements, the study demonstrates an association between the increase in the density of small vacancy clusters with irradiation and a remarkable reduction in the size of large voids. This, previously unknown, mechanism for the interaction of cascade damage with voids in ion-irradiated materials is a consequence of the high porosity of the initial microstructure.

36 MATERIALS SCIENCE↗

Momentum-exchange interactions in a Bragg atom interferometer suppress Doppler dephasing

Large ensembles of laser-cooled atoms interacting through infinite-range photon-mediated interactions are powerful platforms for quantum simulation and sensing. Here we realize momentum-exchange interactions in which pairs of atoms exchange their momentum states by collective emission and absorption of photons from a common cavity mode, a process equivalent to a spin-exchange or XX collective Heisenberg interaction. The momentum-exchange interaction leads to an observed all-to-all Ising-like interaction in a matter-wave interferometer. A many-body energy gap also emerges, effectively binding interferometer matter-wave packets together to suppress Doppler dephasing in analogy to Mössbauer spectroscopy. The tunable momentum-exchange interaction expands the capabilities of quantum interaction–enhanced matter-wave interferometry and may enable the realization of exotic behaviors, including simulations of superconductors and dynamical gauge fields.

Science & Technology - Other Topics↗

Molecular velocimetry using stimulated Raman spectroscopy

Molecular flow velocity of N2 was measured in a supersonic wind tunnel using inverse Raman spectroscopy. This technique employs the large Doppler shift exhibited by the molecules when the pump and probe laser beams are counter-propagating (backward scattering). A retrometer system is employed to yield a vibration-free optical configuration which has the additional advantage of obtaining both the forward and backward scattered spectra simultaneously. The linebreadths and their relative Doppler shift can be used to determine the static pressure, translational temperature, and molecular flow velocity. A demonstration of the concept was performed in a supersonic wind tunnel and included: (1) measurements over the Mach number range 2.50 to 4.63; (2) static pressure measurements (at Mach 2.50) corresponding to a Reynolds number per foot range of 1 to 5 x 10 to the 6th power; and (3) measurements behind the shock wave of a flat plate model.

Exton, R. J.↗

The permanent electric dipole moment of chromium monoxide

The permanent electric dipole moments for the X 5Pi and B 5pi states of gas-phase CrO have been experimentally determined using the sub-Doppler optical technique of intermodulated fluorescence spectroscopy in conjunction with the Stark effect. The measured values are 3.88 + or - 0.13 and 4.1 + or - 1.8 D for the X and B states, respectively. The theoretical values determined for the X state using multireference CI iterative-natural-orbital and finite-field calculations are in excellent agreement with the experimental value.

Steimle, Timothy C.↗