Search NASA⌕ Search

SEARCH · Search NASA

Results for “Doppler spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Intrinsic Lyα Profiles of High-velocity G, K, and M Dwarfs

Observations of HILymanα, the brightest UV emission line of late-type stars, are critical for understanding stellar chromospheres and transition regions, modeling photochemistry in exoplanet atmospheres, and measuring the abundances of neutral hydrogen and deuterium in the interstellar medium. Yet Lyαobservations are notoriously challenging owing to severe attenuation from interstellar gas, hindering our understanding of this important emission line’s basic morphology. We present high-resolution far- and near-UV spectroscopy of five G, K, and M dwarfs with radial velocities large enough to Doppler-shift the stellar Lyαemission line away from much of the interstellar attenuation, allowing the line core to be directly observed. We detect self-reversal in the Lyαemission-line core for all targets, and we show that the self-reversal depth decreases with increasing surface gravity. Mg II self-reversed emission-line profiles provide some useful information to constrain the Lyαline core, but the differences are significant enough that Mg II cannot be used directly as an intrinsic Lyαtemplate during reconstructions. We show that reconstructions that neglect self-reversal could overestimate intrinsic Lyαfluxes by as much as 60%–100% for G and K dwarfs and 40%–170% for M dwarfs. The five stars of our sample have low magnetic activity and subsolar metallicity; a larger sample size is needed to determine how sensitive these results are to these factors.

Allison Youngblood↗

Instrumental sensing of stationary source emissions

A variety of programs have been conducted within EPA to evaluate the capability of various ground-based remote-sensing techniques for measuring the SO2 concentration, velocity, and opacity of effluents from coal-burning power plants. The results of the remote measurements were compared with the results of instack measurements made using EPA reference methods. Attention is given to infrared gas-filter correlation radiometry for SO2 concentration, Fourier-transform infrared spectroscopy for SO2 concentration, ultraviolet matched-filter correlation spectroscopy for SO2 concentration, infrared and ultraviolet television for velocity and SO2 concentration, infrared laser-Doppler velocimetry for plume velocity, and visible laser radar for plume opacity.

Herget, W. F.↗

Ultranarrowband searches for extraterrestrial intelligence with dedicated signal-processing hardware

An evaluation is made of the prospects for SETI applications of multichannel spectroscopy, assuming narrowband RF beacon transmission, with a mHz resolution that matches interstellar medium properties. Receiver Doppler corrections must furnish substantial interference rejection. Results are presented from an Arecibo antenna search of 250 sunlike stars at 1.4 and 2.8 GHz. A meridian transit search of the northern sky is also in progress with the Harvard-Smithsonian 26-m antenna.

Horowitz, P.↗

Cerebrovascular Responses During Lower Body Negative Pressure-Induced Presyncope

Reduced orthostatic tolerance is commonly observed after space flight, occasionally causing presyncopal conditions. Although the cerebrovascular system may play an important role in presyncope, there have been few reports concerning cerebral hemodynamics during presyncope. The purpose of this study was to investigate cerebrovascular responses during presyncope induced by lower body negative pressure (LBNP). Seven healthy male volunteers were exposed to LBNP in steps of -10 mmHg every 3 min until presyncopal symptoms were detected. Blood pressure (BP) and heart rate (HR) were measured with a finger cuff. Cerebral tissue oxy- and deoxy- hemoglobin (Hb) concentrations were estimated using near infrared spectroscopy (NIRS). Cerebral blood flow (CBF) velocity at the middle cerebral artery was measured with Transcranial Doppler Sonography (TCD). We focused on the data during the 2 min before endpoint. BP marked a gradual decrease (91 to 86 mmHg from 2 min to 30 sec before endpoint), which was accelerated along with HR decrease during the final 30 sec (86 to 71 mmHg). Cerebral oxy-Hb concentration decreases as presyncope is approached while total-Hb concentration remains fairly constant. TCD reveals a decrease in the CBF velocity. The TCD and NIRS results suggest that CBF decreases along with the BP decrease. Cerebrovascular responses during presyncope are closely related to cardiovascular responses.

Kuriyama, Kana↗

Coherent Raman spectroscopy for supersonic flow measurments

In collaboration with NASA/Langley Research Center, a truly nonintrusive and nonseeding method for measuring supersonic molecular flow parameters was proposed and developed at Colorado State University. The feasibility of this Raman Doppler Velocimetry (RDV), currently operated in a scanning mode, was demonstrated not only in a laboratory environment at Colorado State University, but also in a major wind tunnel at NASA/Langley Research Center. The research progress of the RDV development is summarized. In addition, methods of coherent Rayleigh-Brillouin spectroscopy and single-pulse coherent Raman spectroscopy are investigated, respectively, for measurements of high-pressure and turbulent flows.

She, C. Y.↗

Review of cometary spectra

The spectra of comet Kohoutek, comet Bradfield, and comet Mrkos are reviewed and compared in relation to stellar spectroscopy and evolution. The possibility of observing the absorption spectrum of a comet and direct measurement of Doppler shifts due to expansion or streaming motions in comets are considered along with the spectra of giant comets, such as, comet Minkowski, comet Baade, and comet Lovas. A speculative explanation for possible intrinsic abundance differences between comets is given.

Herbig, G. H.↗

Remote sensing of stratospheric and mesospheric winds by gas correlation electrooptic phase-modulation spectroscopy

A method is developed for directly measuring atmospheric winds in the 20-120 km altitude interval from a spacecraft. The wind sensor measures the Doppler shift between the spectral absorption lines of a gas in a cell within the instrument and the thermal emission lines of the same gas in the atmosphere. The wind measurements are performed using a spacecraft-borne gas correlation spectrometer viewing the limb of the atmosphere. The wind-induced Doppler shift between the two spectra, and thus the magnitude of the wind itself, is obtained by phase modulating the incoming thermal radiation (equivalent to frequency modulation) by means of an electrooptically active crystal to determine the frequency shift required to reestablish exact correlation between the lines in the cell and the lines from the atmosphere. Results of numerical simulations of the wind-sensor performance indicate that the noise-equivalent-wind is between 1-5 m/s over most of the stratosphere and mesosphere.

Mccleese, D. J.↗

Beam spectroscopy at tandem energies.

Beam-foil spectroscopy above 5.5 Mev for multiply ionized atoms, noting use of Tandem accelerator, spectral resolution, beam intensity and Doppler effect

Jordan, J. A., Jr.↗

Spectroscopic measurements of Mars and Venus with heterodyne techniques

Measurements were made of the exact shape of CO2 absorption lines in Mars and Venus to determine the vertical pressure temperature structure using high resolution heterodyne spectroscopy. Accurate measurements of absolute wind velocities in both the mesosphere and stratosphere of Venus were made from Doppler shifts of narrow CO2 lines, and searches were made for minor molecular species of interest in modeling the stratospheric photochemistry for Mars and Venus.

Betz, A.↗

Time Resolved Spectroscopy of High Field Polars (FUSE 00)

The following work has been accomplished: 1) The emission lines of O VI1 and He II were used to produce Doppler tomograms of the plasma emission. 2) An improved interstellar absorption model is being developed for the CIAO spectral fitting program, Sherpa. Use of the earlier version of this model showed it to be inadequate for its purpose. Once this model is working, we intend to complete our analysis of V884 Her and those of other FUSE programs. In addition to the above work, this grant has helped support the following related work: 1) The publication of the paper "Periodicities in the X-ray intensity variations of TV Columbae: an Intermediate Polar" by Rana, V. R., Singh, K. P., Schlegel, E. M., & Barrett, P. 2004, AJ, 126,489, and 2) FUSE data of a possible nova-like variable Ret 1 has been analyzed and shown to contain a hot (37000 deg) white dwarf (WD 0334-6400). The FUV spectrum shows strong absorption lines of C III.

Barrett, Paul↗

Frequency Correction for MIRO Chirp Transformation Spectroscopy Spectrum

This software processes the flyby spectra of the Chirp Transform Spectrometer (CTS) of the Microwave Instrument for Rosetta Orbiter (MIRO). The tool corrects the effect of Doppler shift and local-oscillator (LO) frequency shift during the flyby mode of MIRO operations. The frequency correction for CTS flyby spectra is performed and is integrated with multiple spectra into a high signal-to-noise averaged spectrum at the rest-frame RF frequency. This innovation also generates the 8 molecular line spectra by dividing continuous 4,096-channel CTS spectra. The 8 line spectra can then be readily used for scientific investigations. A spectral line that is at its rest frequency in the frame of the Earth or an asteroid will be observed with a time-varying Doppler shift as seen by MIRO. The frequency shift is toward the higher RF frequencies on approach, and toward lower RF frequencies on departure. The magnitude of the shift depends on the flyby velocity. The result of time-varying Doppler shift is that of an observed spectral line will be seen to move from channel to channel in the CTS spectrometer. The direction (higher or lower frequency) in the spectrometer depends on the spectral line frequency under consideration. In order to analyze the flyby spectra, two steps are required. First, individual spectra must be corrected for the Doppler shift so that individual spectra can be superimposed at the same rest frequency for integration purposes. Second, a correction needs to be applied to the CTS spectra to account for the LO frequency shifts that are applied to asteroid mode.

Lee, Seungwon↗

Analysis of spectra using correlation functions

A novel method is presented for the quantitative analysis of spectra based on the properties of the cross correlation between a real spectrum and either a numerical synthesis or laboratory simulation. A new goodness-of-fit criterion called the heteromorphic coefficient H is proposed that has the property of being zero when a fit is achieved and varying smoothly through zero as the iteration proceeds, providing a powerful tool for automatic or near-automatic analysis. It is also shown that H can be rendered substantially noise-immune, permitting the analysis of very weak spectra well below the apparent noise level and, as a byproduct, providing Doppler shift and radial velocity information with excellent precision. The technique is in regular use in the Atmospheric Trace Molecule Spectroscopy (ATMOS) project and operates in an interactive, realtime computing environment with turn-around times of a few seconds or less.

Beer, Reinhard↗

Analysis of He I 1083 nm Imaging Spectroscopy Using a Spectral Standard

We develop a technique. for the analysis of He I 1083 nanometer spectra which addresses several difficulties through determination of a continuum background by comparison with a well calibrated standard and through removal of nearby solar and telluric blends by differential comparison to an average spectrum. The method is compared with earlier analysis of imaging spectroscopy obtained at the National Solar Observatory/Kitt Peak Vacuum Telescope (NSO/KPVT) with the NASA/NSO Spectromagnetograph (SPM). We examine distributions of Doppler velocity and line width as a function of central intensity for an active region, filament, quiet Sun, and coronal hole. For our example, we find that line widths and central intensity are oppositely correlated in a coronal hole and quiet Sun. Line widths are comparable to the quiet sun in the active region, are systematically lower in the filament, and extend to higher values in the coronal hole. Outward velocities of approximately equal to 2 to 4 kilometers per second are typically observed in the coronal hole. The sensitivity of these results to analysis technique is discussed.

Malanushenko, Elena V.↗

Non-intrusive flow measurements on a reentry vehicle

This study evaluates the utility of various non-intrusive techniques for the measurement of the flow field on the windward side of the Space Shuttle or a similar re-entry vehicle. Included are linear (Rayleigh, Raman, Mie, Laser Doppler Velocimetry, Resonant Doppler Velocimetry) and nonlinear (Coherent Anti-Stokes Raman, Laser Induced Fluorescence) light scattering, electron beam fluorescence, thermal emission and mass spectroscopy. Flow field properties are taken from a nonequilibrium flow model by Shinn, Moss and Simmonds at NASA Langley. Conclusions are, when possible, based on quantitative scaling of known laboratory results to the conditions projected. Detailed discussion with researchers in the field contributed further to these conclusions and provided valuable insights regarding the experimental feasibility of each of the techniques.

Miles, R. B.↗

Tunable diode laser Stark modulation spectroscopy for rotational assignment of the HNO3 7.5-micron band

The technique of Stark modulation spectroscopy for unraveling and assigning rotationally resolved dense molecular spectra has been employed using a tunable diode laser (TDL) source. Doppler-limited absorption and Stark modulation spectra of the HNO3 7.5-micron band near the 1326/cm band origin are presented with preliminary values of the excited-state rovibrational constants derived from both TDL and Bomem Fourier transform IR spectra.

Webster, C. R.↗

Laboratory molecular spectroscopy

The precision required in making spectroscopic measurements is discussed. Remarks are directed specifically to vibration-rotation spectra rather than continuum absorptions. The ultimate precision that is required for line positions is related to the width of the lines which may be no narrower than the Doppler width. The spectroscopic methods considered are those which are of the most general value to the astronomers; those which acquire and can handle large volumes of spectra in digital form, or in a form which is compatible with computer analysis, and in a form which is at least internally consistent. The use of dye laser, grating instruments, and the most versatile instrument for laboratory spectroscopy, the Fourier transform spectrometer is discussed.

Margolis, J.↗

Evaluation of non-intrusive flow measurement techniques for a re-entry flight experiment

This study evaluates various non-intrusive techniques for the measurement of the flow field on the windward side of the Space Shuttle orbiter or a similar reentry vehicle. Included are linear (Rayleigh, Raman, Mie, Laser Doppler Velocimetry, Resonant Doppler Velocimetry) and nonlinear (Coherent Anti-Stokes Raman, Laser-Induced Fluorescence) light scattering, electron-beam fluorescence, thermal emission, and mass spectroscopy. Flow-field properties were taken from a nonequilibrium flow model by Shinn, Moss, and Simmonds at the NASA Langley Research Center. Conclusions are, when possible, based on quantitative scaling of known laboratory results to the conditions projected. Detailed discussion with researchers in the field contributed further to these conclusions and provided valuable insights regarding the experimental feasibility of each of the techniques.

Miles, R. B.↗

Absolute wind measurements in the lower thermosphere of Venus using infrared heterodyne spectroscopy

The first absolute wind velocities above the Venusian cloud-tops were obtained using NASA/Goddard infrared heterodyne spectrometers at the NASA Infrared Telescope Facility (IRTF) and the McMath Solar Telescope. Beam-integrated Doppler displacements in the non-thermal emission core of (12)C(16)O2 10.33 micron R(8) sampled the line of sight projection of the lower thermospheric wind field (100 to 120 km). A field-usable Lamb-dip laser stabilization system, developed for spectrometer absolute frequency calibration to less than + or - 0.1 MHz, allowed S/N-limited line of sight velocity resolution at the 1 m/s level. The spectrometer's diffraction-limited beam (1.7 arc-second HPBW at McMath, 0.9 arc-second HPBW at IRTF), and 1 to 2 arc-second seeing, provided the spatial resolution necessary for circulation model discrimination. Qualitative analysis of beam-integrated winds provided definitive evidence of a dominant subsolar-antisolar circulation in the lower thermosphere. Beam-integrated winds were modelled with a 100x100 grid over the beam, incorporating beam spatial rolloff and across-the-beam gradients in non-thermal emission intensity, line of sight projection geometry, and horizontal wind velocity. Horizontal wind velocity was derived from a 2-parameter model wind field comprised of subsolar-antisolar and zonal components. Best-fit models indicated a dominant subsolar-antisolar flow with 120 m/s cross-terminator winds and a retrograde zonal component with a 25 m/s equatorial velocity. A review of all dynamical indicators above the cloud-tops allowed development of an integrated and self-consistent picture of circulation in the 70 to 200 km range.

Goldstein, Jeffrey J.↗