Search NASA⌕ Search

SEARCH · Search NASA

Results for “Dose Characterization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Report on Evolution of Inconel 718 Following HFIR Irradiation

The report presents the microstructure and mechanical properties of 3D printed Inconel 718 after irradiation in the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory (ORNL) to assess its potential use as a structural material. The structural components near the outlets of several proposed reactor cores will experience significant neutron fluxes and outlet coolant temperatures ranging from the hot standby temperature of 300 °C to nearly 550 °C at the center of the part. These components must support the core in appropriate loading conditions and require structural analysis at relevant temperatures. In FY21, three heat treatments were designed and conducted to simplify the microstructure and to determine how each precipitating phase contributed to the overall strength. In FY21, baseline mechanical properties were measured from uniaxial tensile tests on subsize SS-J2 specimens at room temperature and at elevated temperatures of 300, 450, and 600 °C to serve a comparison to the irradiated properties. Four capsules containing 3D printed Inconel 718 were inserted into HFIR in FY21 for a matrix of two temperatures and two doses. The lower of the two doses was available for characterization in FY22. Multiple heat treatments of Inconel 718 irradiated to nominal conditions of 2 displacements per atom (dpa) at either 300 or 600 °C were strained with uniaxial tensile tests at the Irradiated Material Examination and Testing (IMET) Facility to discern the mechanical properties. Transmission electron microscopy was performed to correlate the observed mechanical properties with nanoscale features. The initially homogenous AM718-HM increased in strength at both irradiation temperatures based on a high density of nanometer-scale radiation-induced cavities at lower temperature and nucleation and growth of γ" precipitates at higher temperatures. The precipitate-hardened AM718-HT2 showed very small differences in strength before and after irradiation: the contribution to strength from γ" precipitates was replaced with dislocation loops. Because the radioactivity of the nickel superalloys from neutron activation limited the scope of the analysis, a feasibility study examined the possibility of an ultra-miniature specimen geometry, colloquially SS-Tiny (SS-T), for mechanical property determination using the nonirradiated Inconel 718. This study found an overestimation of ductility from the SS-T geometry with yield strength and ultimate tensile strength slightly above the SS-J2 geometry: this could be contributed to a reduction in specimen thickness.

36 MATERIALS SCIENCE↗

Transformative Technology for FLASH Radiation Therapy

The general concept of radiation therapy used in conventional cancer treatment is to increase the therapeutic index by creating a physical dose differential between tumors and normal tissues through precision dose targeting, image guidance, and radiation beams that deliver a radiation dose with high conformality, e.g., protons and ions. However, the treatment and cure are still limited by normal tissue radiation toxicity, with the corresponding side effects. A fundamentally different paradigm for increasing the therapeutic index of radiation therapy has emerged recently, supported by preclinical research, and based on the FLASH radiation effect. FLASH radiation therapy (FLASH-RT) is an ultra-high-dose-rate delivery of a therapeutic radiation dose within a fraction of a second. Experimental studies have shown that normal tissues seem to be universally spared at these high dose rates, whereas tumors are not. While dose delivery conditions to achieve a FLASH effect are not yet fully characterized, it is currently estimated that doses delivered in less than 200 ms produce normal-tissue-sparing effects, yet effectively kill tumor cells. Despite a great opportunity, there are many technical challenges for the accelerator community to create the required dose rates with novel compact accelerators to ensure the safe delivery of FLASH radiation beams.

43 PARTICLE ACCELERATORS↗

C30665L CD3740 Displacement Damage and Total Ionizing Dose Test Report

The purpose of this testing is to provide preliminary characterization of the displacement damage and total ionizing dose effects via 63 MeV protons on InGaAs PIN photodiodes fabricated and assembled by Excelitas for use in a LIDAR system. The testing is being conducted to determine the susceptibility of the component to the radiation environment that it will be exposed to during mission duration.

Landen D Ryder↗

Translating nanoparticle dosimetry from conventional in vitro systems to occupational inhalation exposures

As encouraged by Toxicity Testing in the 21st Century, researchers increasingly apply high-throughput in vitro approaches to identify and characterize nanoparticle hazards, including conventional aqueous cell culture systems to assess respiratory hazards. Translating nanoparticle dose from conventional toxicity testing systems to relevant human exposures remains a major challenge for assessing occupational risk of nanoparticle exposures. Here, we explored existing computational tools and data available to translate nanoparticle dose metrics from cellular test systems to inhalation exposures of silver nanoparticles in humans. We used the Multiple-Path Particle Dosimetry (MPPD) Model to predict deposition of humans exposed to 20 and 110 nm silver nanoparticles at 0.9 µg/m3 over an 8 hr period, the proposed a National Institute of Occupational Safety and Health (NIOSH) recommended exposure limit (REL). MPPD predicts 1.88 and 0.98 µg of silver deposited in an 8 hr period for 20 and 110 nm nanoparticles, respectively, with 20 nm particles displaying nearly 11-fold higher total surface area deposited. Peak nanoparticle concentrations occurred more proximal in the pulmonary tract compared to mass deposition patterns (generation 5 vs. generations 20-21, respectively) due to regional differences in lung lining fluid volumes. Assuming 0.4% nanoparticle dissolution by mass as previously measured, we predict peak concentrations of silver ions in cells of 0.24 and 0.17 µg/mL for 20 and 110 nm particles, respectively. Both predicted concentrations are below the measured toxic threshold of 1.7 µg/mL of silver ions in cells from in vitro assessments. Assuming 4% dissolution by mass, we predict 10-fold higher silver concentrations in tissues, peaking at 2.4 and 1.7 µg/mL, for 20 and 110 nm nanoparticles respectively, exceeding the observed in vitro toxic threshold and highlighting the importance and sensitivity of dissolution rates. Overall, this approach offers a framework for extrapolating nanotoxicity results from in vitro cell culture systems to human exposures. Aligning appropriate dose metrics from in vitro and in vivo hazard characterizations and human pulmonary doses from occupational exposures are critical components for successful nanoparticle risk assessment and worker protection and provide guidance for designing future in vitro studies aimed at relevant human exposures.

Smith, Jordan N.↗

DirectINJECT: Dosing Systems for Concentrated Liquid Biocides

Reliable and mass-efficient techniques for biocide dosing are necessary to enable residual microbial control in spacecraft potable water systems. DirectINJECT is an approach to provide residual microbial control by injection of concentrated aqueous biocide solution (e.g., highly soluble silver salt), and associated dosing systems technology developments. This would allow for well-controlled liquid biocide injection that requires low consumable mass and is insensitive to the chemistry of the target water. With a 40 g Ag+/l solution, required dosing rates would be ~1 μl/minute during water processing (for a system similar to the ISS WPA), requiring only approximately 20 ml/crew-year of concentrate. We identified and characterized the performance of three dosing systems: pressure-driven flow through a robust micro-capillary tube, a miniature peristaltic pump, and a multi-piston pump with integrated valving. We began to address several potential system reliability concerns including prevention or segregation of gas bubbles in the concentrate reservoirs as well as long-term materials compatibility and mechanical life.

Lance Dean Delzeit↗

Total Ionizing Dose Test Report Microchip JANTXV2N6284 NPN Darlington Power Si Transistor

This study was undertaken to determine the effects of total ionizing dose (TID) on the JANTXV2N6284 NPN Darlington power bipolar junction transistor (BJT). The device was parametrically characterized prior to, at each incremental dose step, and after irradiation. Testing was at a low-dose rate using the NASA GSFC Radiation Effects Facility (REF).

Kaitlyn L Ryder↗

Evaluation of Skyshine from an Accelerator Facility: Dependence on Distance and Angle

Neutron skyshine from Linac Coherent Light Source II 4 GeV electron beam operation at SLAC National Accelerator Laboratory can contribute to prompt radiation exposure to the public at distances far beyond the accelerator tunnel housing. One of the shielding design requirements at SLAC is that the annual dose to a member of the public is no more than 0.05 mSv y -1 . Our work uses Monte Carlo code FLUKA to simulate the generation of neutrons from 4 GeVelectron beam losses on a thick copper target inside a generalized geometry of the Linac Coherent Light Source II Beam Transport Hall accelerator tunnel section. The effective dose from neutron skyshine was characterized as a function of both distance from the tunnel wall (up to 1 km away) and angle relative to the beam direction (between 0° and 180°). Furthermore, this new methodology for evaluating neutron skyshine dose is applicable to high-energy GeV-range electron accelerator facilities both at SLAC and elsewhere.

43 PARTICLE ACCELERATORS↗

Si5345, SY88422L, LT3482, and MSK130 components Total Ionizing Dose Test Report

The purpose of this test was to characterize the SI-5345, SY88422L, LT3482 and MSK130 parameter degradation for total dose response. The components are associated with REAG ID #21-024. In the test, each device was exposed to high dose rate (HDR) irradiation using gamma radiation. Device parameters such as leakage currents, timing, and overall chip health were investigated. These devices were tested for an interstellar mission on a trajectory between 0.9 AU and 5.3 AU with a 2.5-year mission, yielding an expected overall dose of 29 krad(Si)behind 1 mm of aluminum shielding (at 95% confidence; environment and dose determined through SPENVIS). This test report gives an initial look at candidate parts. Extremely small sample sizes (only 1 or 2 devices tested) do not allow consideration of part-to-part variability. High dose rates were used despite LT3482 and MSK130 having potential enhanced low dose rate sensitivity (ELDRS). Care should be taken in interpreting results given these limitations.

Total Ionizing Dose (TID)↗

Effect of low-dose scopolamine on autonomic control of the heart

Background: In low doses, scopolamine paradoxically enhances parasympathetic outflow to the heart. The mechanisms which mediate this action are not fully understood. Moreover, there are conflicting data regarding the potential role of sympathetic activity. This study in 17 healthy individuals was designed to characterize the influence of low dose transdermal scopolamine on the gain of the baroreflex and respiratory heart rate reflex and to determine the role of sympathetic activity. Methods: The effect of scopolamine was analyzed in the time and frequency domain by computing heart rate variability indices. The gains of the respiratory heart rate reflex and the baroreflex were estimated simultaneously by means of a cardiovascular system identification approach using an optimized autoregressive moving average algorithm. Measurements were repeated in the upright posture to assess the influence of enhanced sympathetic activity. In six subjects ambulatory ECGs were recorded to determine whether there are diurnal variations of the effect of scopolamine. Results: Scopolamine enhances vagal modulation of heart rate through both the respiratory-heart rate reflex and the baroreflex, as the gains of both were augmented by the drug in the supine and in the upright postures. Conclusions: Scopolamine increases parasympathetic cardiac control by augmenting the gain of the respiratory-heart rate and baroreflex. This action is not attenuated in the upright posture when sympathetic tone is increased.

NASA Discipline Regulatory Physiology↗

Radiometric and Radiation Response of Visible FPAs

The readout integrated circuit (ROIC) used in these devices was originally developed for use in space based infrared systems operating at deep cryogenic temperatures and was selected because of its proven tolerance to total ionizing radiation? The detectors are a 128 x 128 array of 60 pm x 60 pm pixel elements that have been anti-reflection (AR) coated to improve the response at very short wavelengths. These visible focal plane arrays were operated at -40 C (233 K). Two focal planes were characterized using cobalt-60 radiation to produce ionizing total dose damage in the VFPAs. Both operational and performance data were obtained as functions of total dose. The first device tested showed no appreciable change in responsivity or noise up to 300 krad(Si). However, at the next dose level of 600 krad(Si), the readout was non-operational due to failure in the digital circuitry. The second device was characterized to a total dose of 750 krad(Si) with no observed change in responsivity. An increase dark current was observed in both devices, and in the second device, the dark current caused an increase in noise at low irradiance at 400 krad(Si) and above. The increase in dark current was somewhat un-expected for visible PIN detectors. The median dark current increased more than two orders of magnitude at 300 krad(Si) for the first device and a factor of 350 at 750 krad(Si) for pixels near the edge for the second device. The dark current was found to be a strong function of detector bias, with pixels near the edge of the array showing a greater increase in dark current with bias than those near the center. Since the optical response was not a function of bias, it is hypothesized that the dark current is a surface effect and that the variation in dark current with location is due to a variation in pixel bias, caused by a voltage drop across the pixel common lead. As the total dose increased, the dark current and the voltage drop increased

Hubbs, John↗

Biophysical Characterization of the Leukemic Bone Marrow Vasculature Reveals Benefits of Neoadjuvant Low-Dose Radiation Therapy

Although vascular alterations in solid tumor malignancies are known to decrease therapeutic delivery, the effects of leukemia-induced bone marrow vasculature (BMV) alterations on therapeutic delivery are not well known. Additionally, functional quantitative measurements of the leukemic BMV during chemotherapy and radiation therapy are limited, largely due to a lack of high-resolution imaging techniques available preclinically. This study develops a murine model using compartmental modeling for quantitative multiphoton microscopy (QMPM) to characterize the malignant BMV before and during treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Overview of the Translational Radiation Research and Countermeasures (TRRaC) Project in Space Radiation

The Translational Radiation Research and Countermeasures (TRRaC) Project was initiated by the Space Radiation (SR) Element within NASA’s Human Research Program (HRP) to support the SR mission to understand and characterize the space radiation environment, understand and quantify radiation-associated risks, and mitigate the impacts of radiation-induced adverse health outcomes to enable human space exploration. TRRaC’s mission is to translate radiation research results from experimental studies and epidemiological data to humans and astronauts using bioinformatics and computational modeling. TRRaC will leverage existing datasets such as those available from NASA’s GeneLab repository and human medical radiation exposure registries, along with relevant data generated from ground-based research at molecular, cellular, tissue, and system levels, to: (1) refine the radiation dose rate effectiveness factor, (2) characterize radiation quality effects to improve estimates of the risk of exposure-induced death (REID) from space-relevant radiation exposures, and (3) identify pathways and biomarkers for cancer, cardiovascular disease, and central nervous system changes that are impacted by space radiation exposure.

Parastou Eslami↗

DirectINJECT: Dosing Systems for Concentrated Liquid Biocides

Reliable and mass-efficient techniques for biocide dosing are necessary to enable residual microbial control in spacecraft potable water systems. DirectINJECT is an approach to provide ultra-low flow rate injection of stable aqueous biocide concentrate solution (e.g., highly soluble silver salt). This method has the benefit of low consumable mass and is insensitive to the chemistry of the target water. With a 40 g Ag+/liter solution, required dosing rates would be ~1 μl/minute during water processing (for a system similar to the ISS WPA), requiring only approximately 20 ml/crew-year of concentrate. The performance of three dosing systems were identified and characterized: pressure-driven flow through a robust micro-capillary tube with a solenoid valve shut-off, a miniature peristaltic pump, and a multi-piston pump with integrated valving. Several potential system reliability concerns are addressed including prevention or segregation of gas bubbles in the concentrate reservoirs as well as long-term materials compatibility and mechanical life.

silver↗

Error Characterization and Mitigation for 16Nm MLC NAND Flash Memory Under Total Ionizing Dose Effect

A data device includes a memory having a plurality of memory cells configured to store data values in accordance with a predetermined rank modulation scheme that is optional and a memory controller that receives a current error count from an error decoder of the data device for one or more data operations of the flash memory device and selects an operating mode for data scrubbing in accordance with the received error count and a program cycles count.

Li, Yue↗

Selected Area Manipulation of MoS 2 via Focused Electron Beam-Induced Etching for Nanoscale Device Editing

Here we demonstrate direct-write patterning of single and multilayer MoS 2 via a focused electron beam-induced etching (FEBIE) process mediated with the XeF 2 precursor. MoS 2 etching is performed at various currents, areal doses, on different substrates, and characterized using scanning electron and atomic force microscopies as well as Raman and photoluminescence spectroscopies. Scanning transmission electron microscopy reveals a sub-40 nm etching resolution and the progression of point defects and lateral etching of the consequent unsaturated bonds. The results confirm that the electron beam-induced etching process is minimally invasive to the underlying material in comparison to ion beam techniques, which damage the subsurface material. Single-layer MoS 2 field-effect transistors are fabricated, and device characteristics are compared for channels that are edited via the selected area etching process. The source–drain current at constant gate and source–drain voltage scale linearly with the edited channel width. Moreover, the mobility of the narrowest channel width decreases, suggesting that backscattered and secondary electrons collaterally affect the periphery of the removed area. Focused electron beam doses on single-layer transistors below the etching threshold were also explored as a means to modify/thin the channel layer. The FEBIE exposures showed demonstrative effects via the transistor transfer characteristics, photoluminescence spectroscopy, and Raman spectroscopy. While strategies to minimize backscattered and secondary electron interactions outside of the scanned regions require further investigation, here, we show that FEBIE is a viable approach for selective nanoscale editing of MoS 2 devices.

36 MATERIALS SCIENCE↗

X-Ray Induced Chemical Reaction Revealed by In Situ X-Ray Diffraction and Scanning X-Ray Microscopy in 15 nm Resolution

The detection sensitivity of synchrotron-based X-ray techniques has been largely improved due to the ever-increasing source brightness, which has significantly advanced ex situ and in situ research for energy materials such as lithium-ion batteries. However, the strong beam–material interaction arising from the high beam flux can substantially modify the material structure. The beam-induced parasitic effect inevitably interferes with the intrinsic material property, making the interpretation of the experimental results difficult and requiring comprehensive assessments. Here, we present a quantitative study of the beam effect on an electrode material Ag 2 VO 2 PO 4 using four different X-ray characterization methods with different radiation dose rates. The material system exhibits interesting and reversible radiation-induced thermal and chemical reactions, further evaluated under electron microscopy to illustrate the underlying mechanism. Further, the work will provide a guideline for using synchrotron X-rays to distinguish the intrinsic behavior from extrinsic structure change of materials induced by X-rays.

36 MATERIALS SCIENCE↗

Tank Waste Characterization: History, Challenges, and Success Stories

The preparation and chemical and radiochemical analysis of Hanford tank waste samples can be performed with standard laboratory equipment and instruments as relatively routine processes that are not particularly challenging. Rather, the main challenges of tank waste characterization are associated with radiological dose and sampling limitations. Accurate, representative and effective sampling techniques are difficult with the waste tanks because they were not designed for routine sampling. There are a finite number of sampling locations for each tank based on riser positioning, depth and the operational functionality of the sampling riser. For example, in one recently emptied SST, there was one riser that was found to have had concrete dumped down it, thereby eliminating that sampling port. Additionally, the waste within the tank; especially true for the saltcake and sludge, is not homogenous. The ability to adequately mix a million-gallon double shell tank (DST) is a concern for data reproducibility. Another real challenge that must be addressed for sampling single shell tanks, is how to dissolve the salt cake waste in a compromised (leaking) SST. These physical constraints mean that uncertainty in the representativeness of samples must be considered when applying analytical results to the bulk contents of the tank. The tank waste is highly radioactive and thus can only be handled initially by facilities that can receive samples into concrete-shielded hot cells with remote operation with an example provided in Figure 1. The shielding protects the worker from the radiological dose while mineral oil windows and remotely operated manipulators enables the samples to be handled. At Hanford, analytical laboratories with these hot cell capabilities are limited to the Pacific Northwest National Laboratory and the main Hanford operations support laboratory, 222-S Laboratory. Because of their highly radioactive nature, samples must be sufficiently diluted to facilitate their analysis outside of a shielded cell. In some cases, this means some accuracy must be compromised to complete the analysis beyond that normally encountered for non-radioactive material.

Waste Characterization, BBI, PHOENIX: Tank Farms: ↗