Search NASA⌕ Search

SEARCH · Search NASA

Results for “Dose Rate Calculations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

SCALE 6.2.4 Validation: Radiation Shielding

For safe and reliable use of computer codes by the community, accuracy must be clearly evaluated. In particular, the nuclear reactor engineering and licensing field needs accurate tools for radiation shielding modeling. Monaco with Automated Variance Reduction using Importance Calculations (MAVRIC) is one such tool, with built-in variance reduction methods distributed within the SCALE code, and its validity is demonstrated in this report for the released version 6.2.4. Representative benchmarks corresponding to shielding analysis are selected for the validation study. Typical experimental results analyzed from those benchmarks include neutron fluxes, detector count rates, detector energy response functions, neutron and gamma doses, foil neutron activation rates and activities, neutron leakage fluxes, and skyshine dose rates. Thousands of points of comparison between experiment and calculation are presented in this work. Other than rare outliers typically explained by either a lack of information or large uncertainties in the experiment conditions, material, or dimensions, MAVRIC agrees well with the experiment results. MAVRIC is also compared to Monte Carlo N-Particle (MCNP) calculations when available, and both codes generally produce good agreements within estimated uncertainties. The selected benchmarks are obtained from reliable sources such as the International Criticality Safety Benchmark Evaluation Project Handbook (ICSBEP Handbook), the Shielding Integral Benchmark Archive & Database (SINBAD), and other shielding validation work found in the literature. Additional datapoints and benchmarks will be added to future versions of this report to incrementally expand the shielding validation suite incrementally.

61 RADIATION PROTECTION AND DOSIMETRY↗

Generation of Beamline Sources – Preliminary Design (Second Target Station (STS) Project)

This report provides a short summary of how four neutron beamline sources at the US Department of Energy’s Oak Ridge National Laboratory were generated for use in shielding and activation analysis along Second Target Station (STS) neutron beamlines, inside and outside the bunker, and inside instrument caves. Analysis of these sources shows that an angular acceptance of ±2° from the axis of the neutron beamline is all that is needed to accurately model dose rates for these applications. Further analysis shows that the surface area of the tallies used to calculate these sources, and therefore the number of particles in the sources (normalization), should be scaled up to ~19 × 19 cm to provide conservative estimates of dose rate outside the bunker. The spectrum of neutrons entering beamline 11 (ST11), which has the hardest spectrum at high energies and the most neutrons below 100 eV, produces the largest prompt dose rates inside and outside the bunker and the largest number of activation products inside the bunker, therefore, producing the largest residual dose rates.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Shielding Thickness Recommendations for an Activated Target Segment Vertical Stave

This analysis examines the shielding requirements needed to plan maintenance and handling operations of the target segment assembly vertical stave. It provides the analyses and results that fulfill the requirements of Task Order TO-150. The vertical stave is a stainless-steel welded assembly that carries cooling water to and from the target block. In this report, we characterize the dose rates and shielding requirements for the vertical stave only, i.e., separated from the target block. Shielding and dose rates for the target block only have been calculated in response to TO-008.

61 RADIATION PROTECTION AND DOSIMETRY↗

Overview on Analyses of Dose Rates During RID Parts Removal/Exchange

One of the most irradiated Spallation Neutron Source (SNS) accelerator components is ring injection dump (RID), which is located downstream of the accumulator ring injection section. The unstripped and only partially stripped H- beam is discarded in the injection into the accumulator ring and is redirected to the RID, which is about 5% of the full beam current. According to the accelerator operation plan, the beam stop and the window assemblies of the existing RID will be removed and replaced, when they have reached their end-of-life. This procedure, which includes multiple steps, is scheduled to take place during facility maintenance period in January 2023.In order to support job planning and meet ALARA requirements during removal and exchange of the components, dose rates for each stage of exchange operation are calculated.

Popova, Irina I.↗

Comparison and calibration of dose delivered by 137 Cs and x-ray irradiators in mice

Objective. The Office of Radiological Security, U.S. Department of Energy's National Nuclear Security Administration, is implementing a radiological risk reduction program which seeks to minimize or eliminate the use of high activity radiological sources, including 137 Cs, by replacing them with non-radioisotopic technologies, such as x-ray irradiators. The main goal of this paper is to evaluate the equivalence of the dose delivered by gamma- and x-ray irradiators in mice using experimental measurements and Monte Carlo simulations. We also propose a novel biophantom as an in situ dose calibration method. Approach. We irradiated mouse carcasses and 3D-printed mouse biophantoms in a 137 Cs irradiator (Mark I-68) and an x-ray irradiator (X-Rad320) at three voltages (160 kVp, 225 kVp and 320 kVp) and measured the delivered radiation dose. A Geant4-based Monte Carlo model was developed and validated to provide a comprehensive picture of gamma- and x-ray irradiation in mice. Main Results. Our Monte Carlo model predicts a uniform dose delivered in soft-tissue for all the explored irradiation programs and in agreement with the absolute dose measurements. Our Monte Carlo model shows an energy-dependent difference between dose in bone and in soft tissue that decreases as photon energy increases. Dose rate depends on irradiator and photon energy. We observed a deviation of the measured dose from the target value of up to –9% for the Mark I-68, and up to 35% for the X-Rad320. The dose measured in the 3D-printed phantoms are equivalent to that in the carcasses within 6% uncertainty. Significance. Our results suggest that 320 kVp irradiation is a good candidate to substitute 137 Cs irradiation barring a few caveats. There is a significant difference between measured and targeted doses for x-ray irradiation that suggests a strong need for in situ calibration, which can be achieved with 3D-printed mouse biophantoms. A dose correction is necessary for bone doses, which can be provided by a Monte Carlo calculation. Lastly, the biological implications of the differences in dose rates and dose per photon for the different irradiation methods should be carefully assessed for each small-animal irradiation experiment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SCALE 6.3 Validation: Radiation Shielding

Safe and reliable use of scientific and engineering computer codes requires validation for the types of applications in which they will be used. An example in the nuclear reactor engineering and licensing field is radiation transport employed in shielding analyses. The validity of computer codes for shielding applications is demonstrated in this report for SCALE version 6.3.0. Representative benchmarks corresponding to shielding analyses are selected for the validation study. Typical measurement results analyzed from these benchmarks include neutron fluxes, detector count rates, detector energy response functions, neutron and gamma dose rates, neutron activation rates and activities, neutron leakage fluxes, and skyshine dose rates. Thousands of points of comparison between measurement and calculation are presented in this work. Other than rare outliers typically explained by either a lack of information or large uncertainties in the experiment conditions, material, or dimensions, the Monaco with Automated Variance Reduction using Importance Calculations (MAVRIC) radiation transport computer code with built-in variance reduction methods distributed with the SCALE computer code system agrees well with the measurement results. In selected benchmarks, MAVRIC is also compared to Monte Carlo N- Particle® (MCNP® ) 1 calculations. Both computer codes generally agree well within the estimated uncertainties. With the release of SCALE 6.3.0, Shift was integrated as an alternative transport solver in MAVRIC, denoted MAVRIC-Shift. Although the traditional MAVRIC using Monaco was used primarily in this validation study, many results have also been generated using MAVRIC-Shift. Agreement between MAVRIC-Monaco and MAVRIC-Shift is generally very good. The benchmarks presented in this report were obtained from reliable sources such as the International Criticality Safety Benchmark Evaluation Project Handbook, the Shielding Integral Benchmark Archive & Database, and other shielding validation work found in the literature. Additional datapoints and benchmarks will be added to future versions of this report to expand the shielding validation suite.

61 RADIATION PROTECTION AND DOSIMETRY↗

A fast Monte Carlo cell-by-cell simulation for radiobiological effects in targeted radionuclide therapy using pre-calculated single-particle track standard DNA damage data

Introduction: We developed a new method that drastically speeds up radiobiological Monte Carlo radiation-track-structure (MC-RTS) calculations on a cell-by-cell basis. Methods: The technique is based on random sampling and superposition of single-particle track (SPT) standard DNA damage (SDD) files from a “pre-calculated” data library, constructed using the RTS code TOPAS-nBio, with “time stamps” manually added to incorporate dose-rate effects. This time-stamped SDD file can then be input into MEDRAS, a mechanistic kinetic model that calculates various radiation-induced biological endpoints, such as DNA double-strand breaks (DSBs), misrepairs and chromosomal aberrations, and cell death. As a benchmark validation of the approach, we calculated the predicted energy-dependent DSB yield and the ratio of direct-to-total DNA damage, both of which agreed with published in vitro experimental data. We subsequently applied the method to perform a superfast cell-by-cell simulation of an experimental in vitro system consisting of neuroendocrine tumor cells uniformly incubated with 177 Lu. Results and discussion: The results for residual DSBs, both at 24 and 48 h post-irradiation, are in line with the published literature values. Our work serves as a proof-of-concept demonstration of the feasibility of a cost-effective “in silico clonogenic cell survival assay” for the computational design and development of radiopharmaceuticals and novel radiotherapy treatments more generally.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dose Calculations from Source Models and Gamma-Ray Spectra

Gamma-ray dose rates computed by two radiation source model-based methods and five measured spectrum-based methods are compared. With the exception of a Detective DX-100, which reported dose rates that are about 25% less than the mean, dose rates are generally within 10% of mean values. Methods for computation of dose rates employed by the Gamma Detector Response and Analysis Software (GADRAS) are described and critically evaluated. Results are presented for a feasibility evaluation that seeks to use spectra recorded inside vehicles to estimate the minimum dose outside the vehicles.

61 RADIATION PROTECTION AND DOSIMETRY↗

Thermal impacts on nondestructive analysis measurements of uranium hexafluoride

A series of nondestructive assay measurements were performed before, during, and after localized heating of an industrial standard 12B cylinder of uranium hexafluoride to replicate dose variations previously observed on commercial 30B cylinders. While cylinders represent a closed system, enrichment measurements may be impacted by altered uranium and daughter product distributions due to sublimation. A series of measurements were performed to examine localized heating impacts on dose rates, ratios of uranium and daughter product distributions, and measured 235 U enrichment as calculated by two different approaches. The less complex enrichment meter approaches were found to be more robust and less prone to deviation than isotope ratio approaches such as FRAM, but the impact can be minimized by using observable dose changes to avoid impacted areas.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Modeling a generic TRISO-fueled heat pipe microreactor using SCALE: Depletion, transportation criticality, and shielding

This paper demonstrates the applicability of the SCALE code system to tristructural-isotropic (TRISO)-fueled heat pipe microreactors through depletion, transportation criticality, and shielding analyses of a generic reference design. The study conducted supports US Nuclear Regulatory Commission code readiness efforts for advanced non–light-water reactor technologies and is intended as a code capability demonstration rather than as an optimization of a specific microreactor design. The modeled reactor employs high-assay low-enriched uranium (HALEU) uranium oxycarbide (UCO) TRISO fuel and beryllium oxide (BeO) reflectors and operates at 7.5 MWth with a nominal lifetime of about 3 effective full power years. Representative cases for fresh and irradiated cores were selected to exercise SCALE methods relevant to reactor operation and post-irradiation transport. The discharged-core decay heat is approximately 6% of operating power immediately after shutdown. Transportation criticality calculations show that internal water ingress is the dominant reactivity effect, with fully flooded fresh core and irradiated core configurations remain above the subcriticality criterion, even with the available control mechanisms. Shielding calculations for a simplified transportation package indicate that normal-condition dose rates are governed mainly by shielding thickness and cooling time, whereas the breached hypothetical accident case is governed primarily by cooling time. Overall, the study shows that SCALE supports depletion, transportation criticality, and shielding evaluations efficiently for TRISO-fueled heat pipe microreactors within a single code system.

Criticality↗

Verification and Validation Tests of Gamma Library of MC2-3 for Coupled Neutron and Gamma Heating Calculation

For the accurate assessment of the heat generation rate in fast reactors, the gamma library of MC2 -3 and the MC2 -3 + GAMSOR procedure employing the coupled neutron and gamma heating calculation has been thoroughly verified against Monte Carlo results and validated using the ZPPR-15D gamma dose measurement data. NJOY outputs are post-processed in a consistent way with the NJOY procedure to avoid any missing data or double counting of data. Prompt heating for 379 out of 391 isotopes in the gamma library was verified against MCNP6.2 to within 1% relative error in total heating for most isotopes. For both a simple one-dimensional slab problem representing a sodium cooled fast reactor and the Experimental Breeder Reactor II (EBR-II) benchmark problem, the root-mean-square values of assembly power error were less than 0.5% for fuel assemblies, ~1% in blankets and ~1 to ~3% in reflectors compared to MCNP6.2 results. The most plausible cause for the 3% error in a reflector assembly is believed to be the error in the multigroup neutron cross sections for the reflector assembly. For validation, gamma doses measured with thermoluminiscent dosimeters (TLDs) in the ZPPR-15D experiment were calculated using GAMSOR. Due to the uncertainty in the TLD measurement with regards to the energy deposition of photons and neutrons, the validation data leads to a 12.7% uncertainty on the experimental measurement. With this uncertainty bound, the calculated doses all fell within one standard deviation of the measured value. Combined with the accurate calculation of reaction rate distributions and neutron spectrum measurements, these results indicate good agreement for the neutron and gamma heating calculations that were performed.

coupled neutron and gamma heating↗

Radiological analysis and transmutation calculation of representative castable nanostructured alloys

In this work, radiological analysis regarding the waste management was performed on two current reduced-activation ferritic-martensitic (RAFM) steels Eurofer 97 and F82H and two castable nanostructured alloys (CNAs) CNA1 and CNA3 using the European DEMO first wall spectrum. CNA1 and CNA3 are a new generation of RAFM steels, which have increased amounts of nanoscale carbonitrides and carbides precipitates, respectively, via small composition modifications. Furthermore, the increased nitrogen in CNA1 leads to higher activity at ≥50 years, and thus to the disposal concern under the current NRC regulation. However, the calculation using Fetter’s evaluation leads to reduced waste disposal rating (WDR) of down to 0.25 depending on the damage dose from ~0.05 wt percent nitrogen in CNA1, and thus less concern on the waste disposal. Contact dose rate after 10 years from the first wall replacement primarily depends on the initial Co and Nb impurity levels. Other added elements, such as V and Si in CNA1 and Ti and Mn in CNA3, do not have significant effect on the specific activity, contact dose rate, or decay heat. Composition limits of CNAs are given based on the shallow burial disposal and materials recycling. In addition, composition evolution of typical precipitates in the CNAs was calculated using the DEMO first wall and the HFIR spectra. Larger transmutation-induced composition evolution occurs in the V/Ta-rich carbonitrides in CNA1 than that in the Ti-rich carbides in CNA3.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Radiation-induced bowing of SiC/SiC composites under neutron flux gradients—integral experimental data for model validation

Here, the radiation-induced swelling of SiC and its composites, including strong dependencies on temperature and dose, can drive significant lateral bowing in the presence of temperature and/or dose gradients. In recent years, simulations have been performed to assess the extent of bowing in SiC composite light-water reactor (LWR) fuel cladding and boiling water reactor (BWR) channel boxes. However, to date, no integral experimental data exist to validate these models. This work provides the first experimental bowing evaluation of three ∼380 mm long SiC composite specimens irradiated under varying neutron dose gradients (∼50°C–60°C, 0.03–0.06 dpa): two tubes (∼9.8 mm diameter) and a miniature BWR channel box (∼30 mm square). The measured radiation-induced length swelling (∼0.3%–0.7% linear) was consistently 10%–21% higher than values obtained from 3D finite element structural analyses with inputs from 3D radiation transport calculations. This discrepancy could be at least partially explained by differences in dose rate (∼10 -8 dpa/s) compared to the literature data (∼10-6 dpa/s) used to establish the dose-to-swelling correlations in the model. Nevertheless, the modeled bowing magnitudes (<2 mm) obtained from finite element analyses and simple analytical equations were within the bounds of the experimental measurements for all specimens. With improved confidence in the ability to predict the structural response and measure the macroscopic deformations, future experiments will target transient bowing under neutron flux gradients at representative LWR temperatures and assess whether grid spacers can mitigate the tens of millimeters of bowing that would otherwise be expected in ∼4 m long LWR components.

bowing↗

Methodology for inferring reactor core power distribution from an optical fiber based gamma thermometer array

Here, a 4-step data analytic methodology has been devised for the purpose of inferring the distribution of power in a reactor core, based on the response of an array of optical fiber based gamma thermometers (OFBGTs). This data analytic methodology is crucial for the development of a system of OFBGTs for the purpose of calibrating local power range monitors in boiling water reactors. Such a system would be an improvement to the present calibration system in boiling water reactors, in terms of safety, efficiency, and permanence. The first step of this methodology is to establish an energy balance method. In this method, one uses MCNP to determine response functions, which allow one to convert from gamma thermometer response to power. The gamma thermometers and the reactor core are segmented, such that each gamma thermometer segment provides an estimate of power for each reactor core segment. The estimates of power for the reactor core segments (hereafter referred to as fuel assembly segments) are calculated based on the measured response of the gamma thermometers. The second step of the methodology is to employ a weighting scheme to combine the estimates of the power of the various fuel assembly segments, based on the response of the various OFGBT segments and the incremental dose rates of the various fuel assembly segments to the OFBGT segments. The third step is to iteratively calculate the estimates of the power of the fuel assembly segments, until a convergence criterion is met, which indicates that the calculation has converged. The fourth and final step of the methodology is to estimate the uncertainty of the power for each fuel assembly segment. The mathematical basis for this step is not the focus of this paper. We have used a 3-D homogeneous reactor model to demonstrate the data analytic methodology; and have found that the data analytic methodology operates as intended.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Energy Characterization of the UMD Electron Accelerator

Multiple different groups at Los Alamos National Laboratory have a cited interest in understanding the effects of ionizing radiation in materials. Of especial interest to the ISR division is understanding the effects in materials that are used in the space environment, where radiation is omnipresent and impossible to fully shield from. Development is under way to simulate the effects of radiation damage in detectors and electronics, primarily with particle transport codes such as Geant4 and RAMPART, a code that provides a user friendly interface to Geant4. However, these simulations need benchmarking to experimental tests, some of which have been performed at a variety of small electron accelerator facilities. One of these facilities is the Linear Electron Accelerator at the University of Maryland Radiation Facilities. This facility can provide electron beams on the order of 100 mA delivered in tight macropulse bunches, which allows for experiments where the behavior of electronics is monitored as a function of pulse number. While the beam rates per macropulse of this accelerator is monitored during an experiment via a current pick-off connected to a large graphite beamstop, the energy distribution of this electron beam is not measured during the experiment and has not been well characterized. The energy distribution of the beam is pertinent for these types of experiments, since dose is directly related to energy deposited in a medium. Further, these experiments are performed in open air and sample placement in the room can dictate what dose rate they receive per macropulse. We have created simulated dosemaps for the UMD vault room, but these simulations assume a given energy of the beam, both for calculating the dose and to simulate how much the beam diverges in the air. There have been two attempts now to characterize this accelerator beam energy with a plate type spectrometer, including the most recent experiment earlier this year to quantify the beam energy distribution. These results will also be compared to a dosimetry experiment performed by collaborators at the UMD facility, the details of which are described in Reference. Understanding the electron beam energy is important for future experiments, because the energy directly impacts the dose and radiation damage given to a sample and is important for properly simulating the electron beam when comparing simulation to experiment.

43 PARTICLE ACCELERATORS↗

Initial Steps Towards a Clinical FLASH Radiotherapy System: Pediatric Whole Brain Irradiation with 40 MeV Electrons at FLASH Dose Rates

In this work, we investigated the delivery of a clinically acceptable pediatric whole brain radiotherapy plan at FLASH dose rates using two lateral opposing 40-MeV electron beams produced by a practically realizable linear accelerator system. The EGSnrc Monte Carlo software modules, BEAMnrc and DOSXYZnrc, were used to generate whole brain radiotherapy plans for a pediatric patient using two lateral opposing 40-MeV electron beams. Electron beam phase space files were simulated using a model of a diverging beam with a diameter of 10 cm at 50 cm SAD (defined at brain midline). The electron beams were collimated using a 10-cm-thick block composed of 5 cm of aluminum oxide and 5 cm of tungsten. For comparison, a 6-MV photon plan was calculated with the Varian AAA algorithm. Electron beam parameters were based on a novel linear accelerator designed for the PHASER system and powered by a commercial 6-MW klystron. Calculations of the linear accelerator's performance indicated an average beam current of at least 6.25 µA, providing a dose rate of 115 Gy/s at isocenter, high enough for cognition-sparing FLASH effects. The electron plan was less homogenous with a homogeneity index of 0.133 compared to the photon plan's index of 0.087. Overall, the dosimetric characteristics of the 40-MeV electron plan were suitable for treatment. In conclusion, Monte Carlo simulations performed in this work indicate that two lateral opposing 40-MeV electron beams can be used for pediatric whole brain irradiation at FLASH dose rates of >115 Gy/s and serve as motivation for a practical clinical FLASH radiotherapy system, which can be implemented in the near future.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Analysis of Material Properties of Aged Rigid Polyurethane Foam

Foams are classified as either rigid or flexible and are commonly used in applications such as pipe insulation, carpet fibers, and chair foam cushions. Polyurethane foams are excellent thermal insulators, have excellent mechanical properties, and are chemically inert. With the addition of fire protective additives, polyurethane foams have the ability to intumescence when exposed to high temperatures. For the future storage of the 9977 nuclear shipping packages, the material properties of the General Plastics 3716 rigid polyurethane foam were evaluated for long term performance by comparing aged samples to unaged samples. General Plastics 3716 rigid polyurethane foam was aged from November 2014 to June 2019 at varying temperatures of: 160 deg. F, 160 deg. F + 50% relative humidity (RH), 185 deg. F, 215 deg. F, and 250 deg. F. The foam was then analyzed via Fourier Transform Infrared Spectroscopy (FTIR), 3D Optical Microscope, Thermal Gravimetric Analysis (TGA), Differential Scanning Calorimetry (DSC). FTIR and Optical Microscope: No significant change to chemical or physical structure was evident by FTIR or optical microscope analysis. DSC: Decrease of heat capacity over time for all oven temperatures except a slight increase for the 185 deg. F conditioned foams. Largest decrease evident with foams conditioned at 250 deg. F. A slight increase in heat capacity for humid samples. Similar trends in heat capacities at 71 deg. C and 102 deg. C. TGA: As conditioning temperature increased, a decline was evident in the average percent weight loss, onset temperature, and first derivative peak temperature. No significant effect due to humidity except for a decrease in first derivative peak temperature. Unaged samples exhibited strong intumescence. Foams conditioned at 160 deg. F exhibited slight intumescence. Results suggest fire protective additives decomposed at higher temperatures, which contributed to a lower average percent mass loss in higher temperature conditioning. Further thermal degradation testing would be beneficial to evaluate the ability of the conditioned foams to intumesce. Evaluate irradiation dose rate effects on conditioned foam. Possible conditioning in an environment with a known humidity or analyzing a new aliquot of sample for each trial to achieve a more representative heat capacity calculation.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Radiation shielding analysis of the small-angle X-ray scattering flight tube end station of APS upgrade project

The CSSI beamline of the APSU will have a 20.5 m long, 2.75 m diameter SS end station designed to accept pink beam. In this work, the radiation shielding analysis of this end station is analyzed using STAC8 and FLUKA codes. Effect of mirror properties such as reflectivity, coating, inclination and roughness as well as variation in the steel composition are also studied. 8 mm thick SS is found to be adequate if the source is defined by a pinhole and the white beam is reflected with two mirrors inclined at 3.0 mradian or more. The dose rates from monochromatic beams are found to be below the desired levels when the XOP calculated bandwidth (BW) are used while the use of a flat 0.1% BW requires the mirror inclinations to be above 2.5 mradian or more. STAC8 results are consistently higher than the FLUKA results by about 1.5–2.0 times.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗