Search NASA⌕ Search

SEARCH · Search NASA

Results for “Dose Response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

SU-D-16A-02: A Novel Methodology for Accurate, Semi-Automated Delineation of Oral Mucosa for Radiation Therapy Dose-Response Studies

Purpose: The significant morbidity caused by radiation-induced acute oral mucositis means that studies aiming to elucidate dose-response relationships in this tissue are a high priority. However, there is currently no standardized method for delineating the mucosal structures within the oral cavity. This report describes the development of a methodology to delineate the oral mucosa accurately on CT scans in a semi-automated manner. Methods: An oral mucosa atlas for automated segmentation was constructed using the RayStation Atlas-Based Segmentation (ABS) module. A radiation oncologist manually delineated the full surface of the oral mucosa on a planning CT scan of a patient receiving radiotherapy (RT) to the head and neck region. A 3mm fixed annulus was added to incorporate the mucosal wall thickness. This structure was saved as an atlas template. ABS followed by model-based segmentation was performed on four further patients sequentially, adding each patient to the atlas. Manual editing of the automatically segmented structure was performed. A dose comparison between these contours and previously used oral cavity volume contours was performed. Results: The new approach was successful in delineating the mucosa, as assessed by an experienced radiation oncologist, when applied to a new series of patients receiving head and neck RT. Reductions in the mean doses obtained when using the new delineation approach, compared with the previously used technique, were demonstrated for all patients (median: 36.0%, range: 25.6% – 39.6%) and were of a magnitude that might be expected to be clinically significant. Differences in the maximum dose that might reasonably be expected to be clinically significant were observed for two patients. Conclusion: The method developed provides a means of obtaining the dose distribution delivered to the oral mucosa more accurately than has previously been achieved. This will enable the acquisition of high quality dosimetric data for use in dose-response studies. We would like to thank the Engineering and Physical Sciences Research Council for funding. We acknowledge support from the NIHR RM/ICR Biomedical Research Centre. RayStatation was used under an evaluation agreement with RaySearch Laboratories AB.

60 APPLIED LIFE SCIENCES↗

Plasma and liver acetaminophen-protein adduct levels in mice after acetaminophen treatment: Dose–response, mechanisms, and clinical implications

At therapeutic doses, acetaminophen (APAP) is a safe and effective analgesic. However, overdose of APAP is the principal cause of acute liver failure in the West. Binding of the reactive metabolite of APAP (NAPQI) to proteins is thought to be the initiating event in the mechanism of hepatotoxicity. Early work suggested that APAP-protein binding could not occur without glutathione (GSH) depletion, and likely only at toxic doses. Moreover, it was found that protein-derived APAP-cysteine could only be detected in serum after the onset of liver injury. On this basis, it was recently proposed that serum APAP-cysteine could be used as diagnostic marker of APAP overdose. However, comprehensive dose–response and time course studies have not yet been done. Furthermore, the effects of co-morbidities on this parameter have not been investigated. We treated groups of mice with APAP at multiple doses and measured liver GSH and both liver and plasma APAP-protein adducts at various timepoints. Our results show that protein binding can occur without much loss of GSH. Importantly, the data confirm earlier work that showed that protein-derived APAP-cysteine can appear in plasma without liver injury. Experiments performed in vitro suggest that this may involve multiple mechanisms, including secretion of adducted proteins and diffusion of NAPQI directly into plasma. Induction of liver necrosis through ischemia–reperfusion significantly increased the plasma concentration of protein-derived APAP-cysteine after a subtoxic dose of APAP. While our data generally support the measurement of serum APAP-protein adducts in the clinic, caution is suggested in the interpretation of this parameter. - Highlights: • Extensive GSH depletion is not required for APAP-protein binding in the liver. • APAP-protein adducts appear in plasma at subtoxic doses. • Proteins are adducted in the cell and secreted out. • Coincidental liver injury increases plasma APAP-protein adducts at subtoxic doses. • Plasma APAP-protein adducts are diagnostically useful, but interpret with care.

60 APPLIED LIFE SCIENCES↗

Dose Response for Chromosome Aberrations in Human Lymphocytes and Fibroblasts after Exposure to Very Low Doses of High LET Radiation

The relationship between biological effects and low doses of absorbed radiation is still uncertain, especially for high LET radiation exposure. Estimates of risks from low-dose and low-dose-rates are often extrapolated using data from Japanese atomic bomb survivors with either linear or linear quadratic models of fit. In this study, chromosome aberrations were measured in human peripheral blood lymphocytes and normal skin fibroblasts cells after exposure to very low dose (1-20 cGy) of 170 MeV/u Si-28- ions or 600 MeV/u Fe-56-ions. Chromosomes were analyzed using the whole chromosome fluorescence in situ hybridization (FISH) technique during the first cell division after irradiation, and chromosome aberrations were identified as either simple exchanges (translocations and dicentrics) or complex exchanges (involving greater than 2 breaks in 2 or more chromosomes). The curves for doses above 10 cGy were fitted with linear or linear-quadratic functions. For Si-28- ions no dose response was observed in the 2-10 cGy dose range, suggesting a non-target effect in this range.

Hada, M.↗

SU-F-T-202: An Evaluation Method of Lifetime Attributable Risk for Comparing Between Proton Beam Therapy and Intensity Modulated X-Ray Therapy for Pediatric Cancer Patients by Averaging Four Dose-Response Models for Carcinoma Induction

Purpose: To examine how much lifetime attributable risk (LAR) as an in silico surrogate marker of radiation-induced secondary cancer would be lowered by using proton beam therapy (PBT) in place of intensity modulated x-ray therapy (IMXT) in pediatric patients. Methods: From 242 pediatric patients with cancers who were treated with PBT, 26 patients were selected by random sampling after stratification into four categories: a) brain, head, and neck, b) thoracic, c) abdominal, and d) whole craniospinal (WCNS) irradiation. IMXT was re-planned using the same computed tomography and region of interest. Using dose volume histogram (DVH) of PBT and IMXT, the LAR of Schneider et al. was calculated for the same patient. The published four dose-response models for carcinoma induction: i) full model, ii) bell-shaped model, iii) plateau model, and ix) linear model were tested for organs at risk. In the case that more than one dose-response model was available, the LAR for this patient was calculated by averaging LAR for each dose-response model. Results: Calculation of the LARs of PBT and IMXT based on DVH was feasible for all patients. The mean±standard deviation of the cumulative LAR difference between PBT and IMXT for the four categories was a) 0.77±0.44% (n=7, p=0.0037), b) 23.1±17.2%,(n=8, p=0.0067), c) 16.4±19.8% (n=8, p=0.0525), and d) 49.9±21.2% (n=3, p=0.0275, one tailed t-test), respectively. The LAR was significantly lower by PBT than IMXT for the the brain, head, and neck region, thoracic region, and whole craniospinal irradiation. Conclusion: In pediatric patients who had undergone PBT, the LAR of PBT was significantly lower than the LAR of IMXT estimated by in silico modeling. This method was suggested to be useful as an in silico surrogate marker of secondary cancer induced by different radiotherapy techniques. This research was supported by the Translational Research Network Program, JSPS KAKENHI Grant No. 15H04768 and the Global Institution for Collaborative Research and Education (GI-CoRE), Hokkaido University, founded by the Ministry of Education, Culture, Sports, Science and Technology (MEXT), Japan.

60 APPLIED LIFE SCIENCES↗

Systems Biology Model of Interactions between Tissue Growth Factors and DNA Damage Pathways: Low Dose Response and Cross-Talk in TGFβ and ATM Signaling

The etiology of radiation carcinogenesis has been described in terms of aberrant changes that span several levels of biological organization. Growth factors regulate many important cellular and tissue functions including apoptosis, differentiation and proliferation. A variety of genetic and epigenetic changes of growth factors have been shown to contribute to cancer initiation and progression. It is known that cellular and tissue damage to ionizing radiation is in part initiated by the production of reactive oxygen species, which can activate cytokine signaling, and the DNA damage response pathways, most notably the ATM signaling pathway. Recently, the transforming growth factor β (TGFβ) pathway has been shown to regulate or directly interact with the ATM pathway in the response to radiation. The relevance of this interaction with the ATM pathway is not known although p53 becomes phosphorylated and DNA damage responses are involved. However, growth factor interactions with DNA damage responses have not been elucidated particularly at low doses, and further characterization of their relationship to cancer processes is warranted. Our goal will be to use a systems biology approach to mathematically and experimentally describe the low-dose responses and cross-talk between the ATM and TGFβ pathways initiated by low- and high-LET radiation. We will characterize ATM and TGFβ signaling in epithelial and fibroblast cells using 2D models and ultimately extending to 3D organotypic cell culture models to begin to elucidate possible differences that may occur for different cell types and/or inter-cellular communication. We will investigate the roles of the Smad and Activating transcription factor 2 (ATF2) proteins as the potential major contributors to crosstalk between the TGFβ and ATM pathways, and links to cell cycle control and/or the DNA damage response, and potential differences in their responses at low and high doses. We have developed various experimental approaches to apply to these problems using confocal microscopy and flow cytometry to detail changes at low dose/dose-rate in order to understand individual cell responses, and will establish our mathematical models based on the experimental findings resulting from changes in DNA repair, apoptosis and proliferation.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Heavy particle irradiation, neurochemistry and behavior: thresholds, dose-response curves and recovery of function

Exposure to heavy particles can affect the functioning of the central nervous system (CNS), particularly the dopaminergic system. In turn, the radiation-induced disruption of dopaminergic function affects a variety of behaviors that are dependent upon the integrity of this system, including motor behavior (upper body strength), amphetamine (dopamine)-mediated taste aversion learning, and operant conditioning (fixed-ratio bar pressing). Although the relationships between heavy particle irradiation and the effects of exposure depend, to some extent, upon the specific behavioral or neurochemical endpoint under consideration, a review of the available research leads to the hypothesis that the endpoints mediated by the CNS have certain characteristics in common. These include: (1) a threshold, below which there is no apparent effect; (2) the lack of a dose-response relationship, or an extremely steep dose-response curve, depending on the particular endpoint; and (3) the absence of recovery of function, such that the heavy particle-induced behavioral and neural changes are present when tested up to one year following exposure. The current report reviews the data relevant to the degree to which these characteristics are common to neurochemical and behavioral endpoints that are mediated by the effects of exposure to heavy particles on CNS activity. c2004 COSPAR. Published by Elsevier Ltd. All rights reserved.

Review↗

Dose-Response Data Collection Preparation for the NASA Quesst Mission With the X-59

Supersonic flight has the potential to cut travel times in half; however, community annoyance to sonic booms led to the ban on overland commercial supersonic flight by the Federal Aviation Administration in 1973. As part of its Quesst mission, NASA is developing the X-59 aircraft to demonstrate quiet supersonic flight and collect dose-response data to inform regulators in their efforts to establish noise standards to replace the current supersonic speed limit. This talk presents an overview of the NASA Quesst mission and poses some challenges in collecting and analyzing X-59 dose-response data. For the upcoming community flight campaign, the noise dose is the loudness of a supersonic overflight of the X-59 and the perceptual response from participants is captured via surveys after the flyover events. Establishing a relationship between noise dose and perceptual response will be a key product of these efforts.

X-59↗

False Indications of Dose-Response Nonlinearity in Large Epidemiologic Cancer Radiation Cohort Studies; A Simulation Exercise

This study explores the likely prevalence of false indications of dose-response nonlinearity in large epidemiologic cancer radiation cohort studies (A-bomb survivors, INWORKS, Techa River). Reasons: Increasing numbers of tests of nonlinearity are being made in studies. Hypothesized nonlinear dose-response models have been justified to policy makers by analyses that rely in part on isolated findings that could be statistical fluctuations. After removing dose nonlinearity (linearization) by adjusting person-years of observation at each dose category, indications of nonlinearity, necessarily false, were counted in 5,000 randomized replications of six datasets. The average frequency of any false positive for five indicators of nonlinearity tested against a linear null was roughly 25% in Monte Carlo simulations per study, consistent with binomial calculations, increasing to ~50% within 6 studies assessed. Comparable frequencies were found using Akaike's information criterion (AIC) for model selection or multi-model averaging. False above-zero threshold doses were found more than 50% of the time, averaging to 0.05 Gy, consistent with findings in the 6 studies. Such bias, uncorrected, could distort meta-analyses of multiple studies, because meta-analyses can incorporate high P value findings. AIC-based correction for the extra threshold parameter lowered these false occurrences to 8 to 19%. Given the simulation rates, the possibility of false positives might be noted when isolated findings of nonlinearity are discussed in a regulatory context. When reporting a threshold dose with a P value > 0.05, it would be informative to note the expected high false prevalence rate due to bias.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dose-response curve of EBT, EBT2, and EBT3 radiochromic films to synchrotron-produced monochromatic x-ray beams

Purpose: This work investigates the dose-response curves of GAFCHROMIC{sup Registered-Sign} EBT, EBT2, and EBT3 radiochromic films using synchrotron-produced monochromatic x-ray beams. EBT2 film is being utilized for dose verification in photoactivated Auger electron therapy at the Louisiana State University Center for Advanced Microstructures and Devices (CAMD) synchrotron facility. Methods: Monochromatic beams of 25, 30, and 35 keV were generated on the tomography beamline at CAMD. Ion chamber depth-dose measurements were used to determine the dose delivered to films irradiated at depths from 0.7 to 8.5 cm in a 10 Multiplication-Sign 10 Multiplication-Sign 10-cm{sup 3} polymethylmethacrylate phantom. AAPM TG-61 protocol was applied to convert measured ionization into dose. Films were digitized using an Epson 1680 Professional flatbed scanner and analyzed using the net optical density (NOD) derived from the red channel. A dose-response curve was obtained at 35 keV for EBT film, and at 25, 30, and 35 keV for EBT2 and EBT3 films. Calibrations of films for 4 MV x-rays were obtained for comparison using a radiotherapy accelerator at Mary Bird Perkins Cancer Center. Results: The sensitivity (NOD per unit dose) of EBT film at 35 keV relative to that for 4-MV x-rays was 0.73 and 0.76 for doses 50 and 100 cGy, respectively. The sensitivity of EBT2 film at 25, 30, and 35 keV relative to that for 4-MV x-rays varied from 1.09-1.07, 1.23-1.17, and 1.27-1.19 for doses 50-200 cGy, respectively. For EBT3 film the relative sensitivity was within 3% of unity for all three monochromatic x-ray beams. Conclusions: EBT and EBT2 film sensitivity showed strong energy dependence over an energy range of 25 keV-4 MV, although this dependence becomes weaker for larger doses. EBT3 film shows weak energy dependence, indicating that it would be a better dosimeter for kV x-ray beams where beam hardening effects can result in large changes in the effective energy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Oxidative Stress and Neuroconsequences of the Spaceflight Environment –A 5-ion GCRsim Dose-response Study

The overall scope of this project is to test the hypothesis that Ionizing Radiation (IR), microgravity and social isolation combine synergistically to trigger an oxidative stress response that alters immune homeostasis, brain structure/function, and neurobehavioral/cognitive performance. Specific Aims for this project are to: (1) Determine dose-response curves for acute ‘Five-Ion GCR Simulation’ exposure for immune, brain and performance responses in crew age-matched adult male and female mice; (2) Determine effects of acute ‘Five-Ion GCR Simulation’ exposure singly and in combination with simulated microgravity and social isolation, on immune, brain and performance responses in crew age-matched male and female mice mimicking deep space missions; and (3) Determine efficacy of the dietary antioxidant, Nicotinamide Mononucleotide (NMN), a key intermediate in nicotinamide adenine dinucleotide (NAD+) biosynthesis. Here we exposed mature (23-24-week-old) male and female mice to simulated 5-Ion GCR (either 0, 5, 15, or 50cGy) at the NASA Space Radiation Laboratory (NSRL). Across ‘Acute’ (IR+72hrs and IR+14 days) and ‘Delayed’ (IR+28 to IR+124 days) phases of the 6-month-long study, we assessed immune, neural, and functional (sensorimotor/behavioral/cognitive) responses anticipated during a transit to Mars. This presentation will report on dose-response curves for 5-ion GCRsim related to potential biomarkers; structural/functional changes in the immune and nervous systems; and behavioral/cognitive performance deficits. This project addresses NASA’s efforts to characterize risks and identify appropriate countermeasures in anticipation of future deep space missions. Ensuring crew health and performance during extended transits necessitates that sensorimotor and cognitive abilities remain strong to avoid potentially catastrophic health and safety outcomes.

deep space↗

Systems Biology Model of Interactions Between Tissue Growth Factors and DNA Damage Pathways: Low Dose Response and Cross-Talk in TGFbeta and ATM Signaling

The etiology of radiation carcinogenesis has been described in terms of aberrant changes that span several levels of biological organization. Growth factors regulate many important cellular and tissue functions including apoptosis, differentiation and proliferation. A variety of genetic and epigenetic changes of growth factors have been shown to contribute to cancer initiation and progression. It is known that cellular and tissue damage to ionizing radiation is in part initiated by the production of reactive oxygen species, which can activate cytokine signaling, and the DNA damage response pathways, most notably the ATM signaling pathway. Recently the transforming growth factor β (TGFβ) pathway has been shown to regulate or directly interact with the ATM pathway in the response to radiation. The relevance of this interaction with the ATM pathway is not known although p53 becomes phosphorylated and DNA damage responses are involved. However, growth factor interactions with DNA damage responses have not been elucidated particularly at low doses and further characterization of their relationship to cancer processes is warranted. Our goal will be to use a systems biology approach to mathematically and experimentally describe the low dose responses and cross-talk between the ATM and TGFβ pathways initiated by low and high LET radiation. We will characterize ATM and TGFβ signaling in epithelial and fibroblast cells using 2D models and ultimately extending to 3D organotypic cell culture models to begin to elucidate possible differences that may occur for different cell types and/or inter-cellular communication. We will investigate the roles of the Smad and Activating transcription factor 2 (ATF2) proteins as the potential major contributors to cross- talk between the TGFβ and ATM pathways, and links to cell cycle control and/or the DNA damage response, and potential differences in their responses at low and high doses. We have developed various experimental approaches to apply to these problems using confocal microscopy and flow cytometry to detail changes at low dose/dose-rate in order to understand individual cell responses, and will establish our mathematical models based on the experimental findings resulting from changes in DNA repair, apoptosis and proliferation.

O'Neill, Peter↗

The impact of hydrogen contamination on the Total Dose Response of Linear Bipolar Microcircuits

Recent enhanced low dose rate sensitivity (ELDRS) investigations carried out by RLP Research, Crane, Arizona State University (ASU), and Jet Propulsion Laboratory (JPL) have shown significant differences in the degradation of bipolar microcircuits with total dose in the presence of molecular hydrogen (H2) in packages. This has a significant impact on radiation hardness assurance and opens up opportunity to improve device performance. The objectives of this program are 1) to investigate and confirm the causal relationship between packaging recipes, hydrogen contamination, and total dose response of linear bipolar microcircuits; and 2) to develop a guideline that will take into account these effects at the radiation level for future NASA space missions. This program is geared to benefit all future NASA space missions using bipolar or BiCMOS linear devices.

McClure, Steve S.↗

SU-F-303-15: Ion Chamber Dose Response in Magnetic Fields as a Function of Incident Photon Energy

Purpose: In considering the continued development of synergetic MRI-radiation therapy machines, we seek to quantify the variability of ion chamber response per unit dose in the presence of magnetic fields of varying strength as a function of incident photon beam quality and geometric configuration. Methods: To account for the effect of magnetic fields on the trajectory of charged particles a new algorithm was introduced into the EGSnrc Monte Carlo code. In the egs-chamber user code the dose to the cavity of an NE2571 ion chamber is calculated in two configurations, in 0 to 2 T magnetic fields, with an incoming parallel 10×10 cm{sup 2} photon beam with energies ranging between 0.5 MeV and 8 MeV. In the first, the photon beam is incident on the long-axis of the ion chamber (config-1), and in the second the beam is parallel to the long-axis and incident from the conical end of the chamber (config-2). For both, the magnetic field is perpendicular to the direction of the beam and the long axis of the chamber. Results: The ion chamber response per unit dose to water at the same point is determined as a function of magnetic field and is normalized to the 0T case for each of incoming photon energies. For both configurations, accurate modeling of the ion chamber yielded closer agreement with the experimental results obtained by Meijsing et. al (2009). Config-1 yields a gradual increase in response with increasing field strength to a maximum of 13.4% and 1.4% for 1 MeV and 8 MeV photon beams, respectively. Config-2 produced a decrease in response of up to 6% and 13% for 0.5 MeV and 8 MeV beams, respectively. Conclusion: These results provide further support for ion chamber calibration in MRI-radiotherapy coupled systems and demonstrates noticeable energy dependence for clinically relevant fields.

60 APPLIED LIFE SCIENCES↗

Non-Targeted Effects and the Dose Response for Heavy Ion Tumorigenesis

BACKGROUND: There is no human epidemiology data available to estimate the heavy ion cancer risks experienced by astronauts in space. Studies of tumor induction in mice are a necessary step to estimate risks to astronauts. Previous experimental data can be better utilized to model dose response for heavy ion tumorigenesis and plan future low dose studies. DOSE RESPONSE MODELS: The Harderian Gland data of Alpen et al.[1-3] was re-analyzed [4] using non-linear least square regression. The data set measured the induction of Harderian gland tumors in mice by high-energy protons, helium, neon, iron, niobium and lanthanum with LET s ranging from 0.4 to 950 keV/micron. We were able to strengthen the individual ion models by combining data for all ions into a model that relates both radiation dose and LET for the ion to tumor prevalence. We compared models based on Targeted Effects (TE) to one motivated by Non-targeted Effects (NTE) that included a bystander term that increased tumor induction at low doses non-linearly. When comparing fitted models to the experimental data, we considered the adjusted R2, the Akaike Information Criteria (AIC), and the Bayesian Information Criteria (BIC) to test for Goodness of fit.In the adjusted R2test, the model with the highest R2values provides a better fit to the available data. In the AIC and BIC tests, the model with the smaller values of the summary value provides the better fit. The non-linear NTE models fit the combined data better than the TE models that are linear at low doses. We evaluated the differences in the relative biological effectiveness (RBE) and found the NTE model provides a higher RBE at low dose compared to the TE model. POWER ANALYSIS: The final NTE model estimates were used to simulate example data to consider the design of new experiments to detect NTE at low dose for validation. Power and sample sizes were calculated for a variety of radiation qualities including some not considered in the Harderian Gland data set and with different background tumor incidences. We considered different experimental designs with varying number of doses and varying low doses dependant on the LET of the radiation. The optimal design to detect a NTE for an individual ion had 4 doses equally spaced below a maximal dose where bending due to cell sterilization was < 2%. For example at 100 keV/micron we would irradiate at 0.03 Gy, 0.065 Gy, 0.13 Gy, and 0.26 Gy and require 850 mice including a control dose for a sensitivity to detect NTE with 80% power. Sample sizes could be improved by combining ions similar to the methods used with the Harderian Gland data.

Chappelli, Lori J.↗

Dose--response of initial G2-chromatid breaks induced in normal human fibroblasts by heavy ions

PURPOSE: To investigate initial chromatid breaks in prematurely condensed G2 chromosomes following exposure to heavy ions of different LET. MATERIAL AND METHODS: Exponentially growing human fibroblast cells AG1522 were irradiated with gamma-rays, energetic carbon (13 keV/ microm, 80 keV/microm), silicon (55 keV/microm) and iron (140 keV/microm, 185keV/microm, 440keV/microm) ions. Chromosomes were prematurely condensed using calyculin-A. Initial chromatid-type and isochromatid breaks in G2 cells were scored. RESULTS: The dose response curves for total chromatid breaks were linear regardless of radiation type. The relative biological effectiveness (RBE) showed a LET-dependent increase, peaking around 2.7 at 55-80keV/microm and decreasing at higher LET. The dose response curves for isochromatid-type breaks were linear for high-LET radiations, but linear-quadratic for gamma-rays and 13 keV/microm carbon ions. The RBE for the induction of isochromatid breaks obtained from linear components increased rapidly between 13keV/microm (about 7) and 80keV/microm carbon (about 71), and decreased gradually until 440 keV/microm iron ions (about 66). CONCLUSIONS: High-LET radiations are more effective at inducing isochromatid breaks, while low-LET radiations are more effective at inducing chromatid-type breaks. The densely ionizing track structures of heavy ions and the proximity of sister chromatids in G2 cells result in an increase in isochromatid breaks.

Non-NASA Center↗

Total Ionizing Dose Response of SDRAM, DDR2 and DDR3 Memories

Total Ionizing Dose response (ID) of SDRAM (Synchronous Dynamic Random Access Memory), DDR2 (Double Data Rate2) and DDR3 (Double Data Rate3) memories is reported in static bias, and auto refresh modes. Data analysis reveals some types of memory have significant increases in stuck bits during TID exposure when refreshed.

Amrbar, Mehran↗

WE-D-BRE-06: Quantification of Dose-Response for High Grade Esophagtis Patients Using a Novel Voxel-To-Voxel Method

Purpose: Radiation induces an inflammatory response in the esophagus, discernible on CT studies. This work objectively quantifies the voxel esophageal radiation-response for patients with acute esophagitis. This knowledge is an important first-step towards predicting the effect of complex dose distributions on patient esophagitis symptoms. Methods: A previously validated voxel-based methodology of quantifying radiation esophagitis severity was used to identify the voxel dose-response for 18 NSCLC patients with severe esophagitis (CTCAE grading criteria, grade2 or higher). The response is quantified as percent voxel volume change for a given dose. During treatment (6–8 weeks), patients had weekly 4DCT studies and esophagitis scoring. Planning CT esophageal contours were deformed to each weekly CT using a demons DIR algorithm. An algorithm using the Jacobian Map from the DIR of the planning CT to all weekly CTs was used to quantify voxel-volume change, along with corresponding delivered voxel dose, to the planning voxel. Dose for each voxel for each time-point was calculated on each previous weekly CT image, and accumulated using DIR. Thus, for each voxel, the volume-change and delivered dose was calculated for each time-point. The data was binned according to when the volume-change first increased by a threshold volume (10%–100%, in 10% increments), and the average delivered dose calculated for each bin. Results: The average dose resulting in a voxel volume increase of 10–100% was 21.6 to 45.9Gy, respectively. The mean population dose to give a 50% volume increase was 36.3±4.4Gy, (range:29.8 to 43.5Gy). The average week of 50% response was 4.1 (range:4.9 to 2.8 weeks). All 18 patients showed similar dose to first response curves, showing a common trend in the initial inflammatoryresponse. Conclusion: We extracted the dose-response curve of the esophagus on a voxel-to-voxel level. This may be useful for estimating the esophagus response (and patient symptoms) to complicated dose distributions.

60 APPLIED LIFE SCIENCES↗

The alanine detector in BNCT dosimetry: Dose response in thermal and epithermal neutron fields

Purpose: The response of alanine solid state dosimeters to ionizing radiation strongly depends on particle type and energy. Due to nuclear interactions, neutron fields usually also consist of secondary particles such as photons and protons of diverse energies. Various experiments have been carried out in three different neutron beams to explore the alanine dose response behavior and to validate model predictions. Additionally, application in medical neutron fields for boron neutron capture therapy is discussed. Methods: Alanine detectors have been irradiated in the thermal neutron field of the research reactor TRIGA Mainz, Germany, in five experimental conditions, generating different secondary particle spectra. Further irradiations have been made in the epithermal neutron beams at the research reactors FiR 1 in Helsinki, Finland, and Tsing Hua open pool reactor in HsinChu, Taiwan ROC. Readout has been performed with electron spin resonance spectrometry with reference to an absorbed dose standard in a {sup 60}Co gamma ray beam. Absorbed doses and dose components have been calculated using the Monte Carlo codes FLUKA and MCNP. The relative effectiveness (RE), linking absorbed dose and detector response, has been calculated using the Hansen and Olsen alanine response model. Results: The measured dose response of the alanine detector in the different experiments has been evaluated and compared to model predictions. Therefore, a relative effectiveness has been calculated for each dose component, accounting for its dependence on particle type and energy. Agreement within 5% between model and measurement has been achieved for most irradiated detectors. Significant differences have been observed in response behavior between thermal and epithermal neutron fields, especially regarding dose composition and depth dose curves. The calculated dose components could be verified with the experimental results in the different primary and secondary particle fields. Conclusions: The alanine detector can be used without difficulty in neutron fields. The response has been understood with the model used which includes the relative effectiveness. Results and the corresponding discussion lead to the conclusion that application in neutron fields for medical purpose is limited by its sensitivity but that it is a useful tool as supplement to other detectors and verification of neutron source descriptions.

07 ISOTOPE AND RADIATION SOURCES↗