FY25 double shell shot requests at the National Ignition Facility [Slides]
FY25 Double Shells will perform first mix and burn experiments with Mo and DT at 1.5 MJ. Motivation: Validate predictions of implosion performance using nuclear diagnostics.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
FY25 Double Shells will perform first mix and burn experiments with Mo and DT at 1.5 MJ. Motivation: Validate predictions of implosion performance using nuclear diagnostics.
(1) Background: Non-destructive evaluation of double-shell nuclear-waste storage tanks at the U.S. Department of Energy’s Hanford site requires a robot to navigate a network of air slots in the confined space between primary and secondary tanks. Situational awareness, data collection, and data interpretation require continuous tracking of the robot’s location. (2) Methods: Robot location is continuously monitored using video image analysis for short distances and laser ranging for absolute location. (3) Results: The technique was demonstrated in our laboratory using a mockup of air slot and robot. (4) Conclusions: Location tracking and display provide decision support to inspectors and lay the groundwork for automated data collection.
Waste chemistry controls for the Hanford double-shell tanks (DSTs) were established in the 1980's in response to tank failures caused by stress corrosion cracking (SCC) at the Savannah River Site (SRS). The controls were established based on a combination of SRS chemistry limits and corrosion testing results. Conditions in the Hanford DSTs have changed over time, with the temperature in the majority of the DSTs dropping below 50 deg. C. Testing indicated that the original chemistry control specification and SCC testing performed in 2010 did not protect against pitting corrosion mechanisms - what is believed to have caused the failure of tank 241-AY-102. New waste chemistry controls are necessary to protect the DSTs from both SCC and pitting corrosion. Savannah River National Laboratory (SRNL), with input from the Tank Integrity Expert Panel (TIEP) Corrosion Subgroup (CSG), performed a statistically based investigation of nitrate and halide ion induced pitting corrosion. The investigation was intended to develop a comprehensive waste chemistry envelope that minimizes the risk of both SCC and pitting caused by halide and nitrate ions. The waste chemistry envelope needed to be robust enough to address future waste retrieval and process changes which could significantly change the waste composition of the DSTs. The experimental design allowed the statistically significant ions and their effect on pitting corrosion to be determined. SRNL developed the 'pitting factor' which is an empirical relationship between the statistically significant inhibitive species (hydroxide, and nitrite), and pitting inducing species (nitrate, chloride, and fluoride). The coefficients are weighted factors that show the degree of influence the species have on the propensity for pitting. New waste chemistry control limits were recommended by SRNL, and concurred with by the TIEP CSG, that incorporated the pitting factor along with other limits. The controls developed to reduce the risk of pitting corrosion were evaluated to determine if they also protected against SCC. Hundreds of test results were reviewed and compared against the proposed limits. With the exception of one test result, instances where cracking was observed corresponded to chemistry that was outside of the proposed limits - indicating that the chemistry controls developed for pitting also adequately addressed SCC concerns. Existing tank composition estimates were evaluated against the new chemistry controls - three current tank chemistries are suspect, and may not meet the new chemistry control requirements. These included the interstitial liquid (liquid associated with solids) of DSTs 241-AN-102, 241-AN-106, 241-AN-107, and 241-AY-101. Measures are ongoing to evaluate the tanks with the suspect chemistry. These include varying combinations of: performing additional evaluations (history of use, modeling); DST specific laboratory testing; and, pursuing core samples of the DSTs. (authors)
Access to reliable, clean energy sources is a major concern for national security. Much research is focused on the “grand challenge” of producing energy via controlled fusion reactions in a laboratory setting. For fusion experiments, specifically inertial confinement fusion (ICF), to produce sufficient energy, the fusion reactions in the ICF fuel need to become self-sustaining and burn deuterium-tritium (DT) fuel efficiently. The recent record-breaking NIF ignition shot was able to achieve this goal as well as produce more energy than used to drive the experiment. This achievement brings self-sustaining fusion-based power systems closer than ever before, capable of providing humans with access to secure, renewable energy. In order to further progress toward the actualization of such power systems, more ICF experiments need to be conducted at large laser facilities such as the United States's National Ignition Facility (NIF) or France's Laser Mega-Joule. The high cost per shot and limited number of shots that are possible per year make it prohibitive to perform large numbers of experiments. As such, experimental design relies heavily on complex predictive physics simulations for high-fidelity “preshot” analysis. These multidimensional, multi-physics, high-fidelity simulations have to account for a variety of input parameters as well as modeling the extreme conditions (pressures and densities) present at ignition. Such simulations (especially in 3D) can become computationally prohibitive to turn around for each ICF experiment. In this work, we explore using Bayesian optimization with Gaussian processes (GPs) to find optimal designs for ICF double shell targets, while keeping computational costs to manageable levels. These double shell targets have an inner shell that grades from beryllium on the outer surface to the higher Z material molybdenum, as opposed to the nominally used tungsten, on the inside in order to trade off between the high performance associated with high density inner shells and capsule stability. We describe our results for “capsule-only” xRAGE simulations to study the physics between different capsule designs, inner shell materials, and potential for future experiments.
This work provides a numerical study of how double shell capsule deformations caused by drive asymmetries and fabrication imperfections affect implosion symmetry and neutron yield. Hydrodynamics simulations are performed in two dimensions and focus on low-mode deformations that are caused by corresponding asymmetries in the Hohlraum drive, component offsets, and ablator joint gaps. By providing a parameter study of these features, our goal is to understand the dominant sources for inner shell deformation and yield degradation. The discussed capsules are composed of an aluminum ablator with a chromium inner shell. The latter encloses a carbon-deuterium foam ball that serves as fuel. We find that for clean capsules, even-numbered low-mode asymmetries in the drive are imprinted on the ablator and smoothly transferred to the inner shell during shell collision. The resulting deformation of the inner shell is more pronounced with larger fuel radius, while the yield is inversely proportional to the amplitude of the drive asymmetry and varies by factors ≤4 in comparison with clean simulations. Capsule component offsets in the vertical direction and ablator thickness nonuniformity result in p1-type deformations of the imploding inner shell. Finally, joint gaps have the largest effect in deforming the ablator and inner shell and degrading yield. While small gap widths (1 μm) result in prolate inner shells, larger gap widths (4 μm) cause an oblate deformation. More importantly, capsules with a small outer gap (1 μm) experience a dramatic drop in yield, typically <3% of a clean simulation.
Leaks in the primary liner of double-shell tank (DST) 241-AY-102 at Hanford have prompted the need for the development of inspection tools that are able to access confined spaces around and underneath the tanks. Last year, Florida International University (FIU) has continued to improve inspection tools that were developed in the previous years, to ensure that the resultant tools are able to overcome the challenges posed by the DSTs. Experimental testing conducted last year at the full-scale sectional mock-up of the DST's refractory slots revealed some shortcomings of the miniature rover, particularly in traversing over weld seams of different heights. The weld seams are the results of welded steel plate-joints for the DST. It was advised by the site engineers that the weld seams height could range from 6.35 mm - 9.525 mm (1/4 to 3/8 inches), and with 12.7 mm (1/2 inches) width. As the rover traverses over a weld seam, the gap between the rover's magnets and tank surface increases, causing the adhesive force to drop. The rover loses its surface contact if this adhesive force drops below its weight, jeopardizing the inspection tasks. In this paper, we present the numerical studies to calculate the minimum magnetic force required for the miniature rover to traverse over weld seams with different heights and the corresponding modifications to the rover design. Initial bench scale tests were conducted using a steel bar with 5 welds of varying heights. The testing validated the results from the simulation studies and established the rover's capability in traversing weld seams. Another challenge for the miniature rover is the use of a joystick or keypad for manual control. Utilizing these controls will likely be difficult for the operators due to the tight channels underneath the tank. Having a semi-autonomous navigational capability would alleviate the complexity of the inspection tasks and allow the operator to focus on the channel inspection. The goal is to implement lane-keeping capability, akin to that of a driverless car, for the inspection tool, so that it will maintain its relative position with respect to the wall of the channels. Am image processing pipeline has been developed using both the Robot Operating System (ROS) and OpenCV to process the image stream coming from the onboard camera, for the purpose of lane identification. Additionally, a PID controller has been implemented to navigate the miniature rover along the central location of the detected lane, while allowing the operator to control the tool's forward and backward motion. (authors)
The Hanford Site in Washington State currently stores millions of gallons of radioactive waste in underground, carbon steel, double shell tanks (DSTs) that were constructed between 1968 and 1986. A chemistry control and monitoring program has been established mitigate corrosion in order to extend the service life for the DSTs. The current waste temperatures in the DSTs are at historical lows (i.e., typically less than 50 °C). The previous chemistry control requirements were determined for conditions at temperatures significantly higher. SRNL undertook a statistically based investigation of the role of nitrate and halide ion (i.e., chloride and fluoride) induced pitting corrosion. The objective was to develop a comprehensive waste chemistry envelope for the simultaneous minimization of the pitting and SCC risks caused by halide and nitrate ions at the lower temperature conditions. On the basis of these tests, new chemistry control requirements were proposed and have since been implemented for pitting corrosion control.
The synthesis of double shell (Au-Ag)-Au nanoparticles is accomplished through suppression of the galvanic replacement reaction caused by an electron transfer phenomenon. The resulting nanoparticles are monodisperse with a thin and uniform second Au shell. These particles are ultimately expected to lead to sensitive probes for biomolecular sensing and diagnostics.
ICF researchers benefit by gaining immediate insight into indirect double-shell target physics. Manufacturing Hohlraum out of DU results in additional 6.5% energy “gained” in drive. Final results indicated the validity of Callahan’s model.
During FY15, SRNL performed corrosion testing that supported Washington River Protection Solutions (WRPS) with their double shell tank (DST) integrity program. The testing investigated six concerns including, 1) the possibility of corrosion of the exterior of the secondary tank wall; 2) the effect of ammonia on vapor space corrosion (VSC) above waste simulants; 3) the determination of the minimum required nitrite and hydroxide concentrations that prevent pitting in concentrated nitrate solutions (i.e., waste buffering); 4) the susceptibility to liquid air interface (LAI) corrosion at proposed stress corrosion cracking (SCC) inhibitor concentrations; 5) the susceptibility of carbon steel to pitting in dilute solutions that contain significant quantities of chloride and sulfate; and 6) the effect of different heats of A537 carbon steel on the corrosion response. For task 1, 2, and 4, the effect of heat treating and/ or welding of the materials was also investigated.
Corrosion studies of Hanford Double-Shell Tanks (DSTs) at Savannah River National Laboratory (SRNL) were focused on New Limits testing using statistically design matrices for a high concentration of hydroxide (1.2 M) and testing at various interior points to establish corrosion control guidelines towards pitting corrosion. Ammonia was also added into the statistical design to determine inhibition effects. Additional electrochemical studies of individual organic species and nitrous oxide were tested in a AN-102 based simulant with no organics to compare inhibiting properties of a specific specie and measure any electrochemical improvement towards pitting corrosion.
The performance of epoxy sealants used in the refurbishment of double-shell tank (DST) systems requires balancing processability, thermomechanical stability, and adhesion to cementitious substrates. This study incorporates Heloxy 8 as a reactive diluent into Westlake 862 epoxy to tailor workability and cured-state properties. Rheological time-sweep analysis demonstrates that increasing the diluent content significantly reduces complex viscosity and extends workability, thereby improving pumpability and flow for large-area applications. However, the targeted 2-hour processing window is not fully achieved. Differential scanning calorimetry (DSC) confirms that all formulations cure at room temperature to glass transition temperatures ( T g ) at least 20 °C above the maximum DST operating temperature (27 °C), thereby ensuring service in the glassy regime. Dynamic mechanical analysis (DMA) reveals formulation-dependent reductions in tan delta and increases in storage modulus, indicating increasingly elastic and mechanically stable networks with diluent incorporation. Pull-off adhesion testing shows that modified formulations (70–90% Westlake epoxy) exhibit significantly higher adhesion strengths than the unmodified system. Grout cohesive failure indicates that interfacial bonding exceeds substrate strength. Collectively, these results demonstrate that controlled reactive diluent incorporation enables optimization of processing behavior, interfacial adhesion, and thermomechanical performance, supporting the suitability of the modified epoxy systems as durable sealant layers for cementitious barrier applications in hazardous waste containment infrastructure.
Waste found in the annulus of the AY-102 double-shell tank (DST) at Hanford has prompted the need for the development of inspection tools that are able to access confined spaces around and underneath the tanks. During the last year, Florida International University (FIU) has been developing inspection tools that are capable of accessing the tank floors through the air supply line, the air refractory channels and the drain lines. This effort has led to the development of a pneumatic pipe crawler and a miniature rover. In this paper, updates to the inspection tool designs and the full scale testing of both systems are presented. The tools provide visual feedback for the operator, carrying with them onboard cameras and light sources. The images are streamed back live via a tether, which also provides power to the devices. To increase the sensing capabilities of both tools, temperature, humidity and radiation sensor modules are being integrated onto the developed systems, and can be interchanged depending on the inspection objectives. The miniature rover measures 7 cm in length and 3.8 cm in width, and travels upside down on the bottom of the tank to avoid debris accumulated in the channels. The video is also being processed real-time to provide control of the unit semi-autonomously. The pipe crawler measures approximately 76 cm in length and 6.4 cm in diameter, and travels using pneumatic actuators that emulate the peristaltic movement contractions typical of worm type robots. A full-scale sectional mock-up of the DST foundation, refractory system and annulus is currently being developed as a test-bed for the testing of the inspection tools. The intention of the test-bed is to demonstrate the viability of using both inspection tools in configurations similar to the actual tank. The test-bed includes a 2.43 m wide section of both tank liners, refractory channels and concrete foundation with drain slots. The test-bed is designed to be modular so that various plate thicknesses can be easily utilized and different refractory configurations can be incorporated. Currently, the refractory channels are of the tree type structure with turns that are approximately 30 degrees. Both inspection tools were demonstrated in the mock-up facility. The miniature rover ran successfully through the drain slots from the annulus to central plenum and had no issues making the 90-degree turns. The peristaltic crawler was able to navigate through the 7.62 cm air supply line from the annulus to the central plenum. (authors)
Since at least August 2012, Hanford Tank 241-AY-102 (AY-102) has been leaking from its primary tank into its secondary containment. A pumping plan was developed in 2013 to provide a path forward for recommended remediation actions to be implemented as part of the AY-102 Recovery Project. On March 21, 2014, the Washington State Department of Ecology issued Administrative Order No. 10618 requiring Washington River Protection Solutions and the United States Department of Energy to conduct actions related to and including the removal of waste from AY-102. The three parties agreed to resolve the appeal of the Administrative Order through a Settlement Agreement which addresses the remaining requirements and implements enforceable milestone dates, including initiation of waste retrieval by March 4, 2016 and completion of waste retrieval operations by March 4, 2017. The AY-102 Recovery Project was developed to address the Settlement Agreement requirements. While retrieval of waste from Single-Shell Tanks has been performed at Hanford for decades, retrieval from Double-Shell Tank AY-102 required adaptation of the existing technologies to a new environment on a larger scale than previously encountered. A significant number of obstructions and in-tank equipment limit accessibility to the high source term AY-102 waste and the location of the selected receiver tank required installation of an extensive, heavily-shielded above-ground transfer line. Despite countless challenges and obstacles encountered throughout, the project successfully completed system design, fabrication, installation, testing, and the first phase of operations within a highly compressed, aggressive schedule. Waste retrieval operations in AY-102 commenced on March 3, 2016 and the initial operating phase concluded on April 30. Additional sluicing capability was required to complete the mission and four Extended Reach Sluicers were installed to support the second operating phase, which began on December 8, 2016. As of December 31, 2016, approximately 97% of the original waste volume had been removed, resulting in an estimated remaining waste volume of about 75,000 liters. (authors)
This report highlights the documentation that supported Cold Spray field deployment in double-shell tank (DST) 241-AN-105 (AN-105) in July of 2025. This work was a collaborative effort between VRC Metal Systems (VRC), Robotic Technologies of Tennessee (RTT), the Hanford Tank Waste Operation and Closure (H2C) Chief Technology Office, H2C Tank Farm Projects Engineering, H2C Tank and Pipeline Integrity (TAPI) and H2C Ultrasonic Testing (UT) Operations & Support. Since 2019, the Chief Technology Office has been developing Cold Spray technology for refurbishing Hanford’s DSTs (RPP-RPT-65015). This technology is particularly relevant for addressing localized corrosion within the annulus of the DSTs by propelling metal powder particles at supersonic speeds to targeted areas. This process results in high-quality coatings characterized by high bond strength and low porosity result.
Tank AY-102 was the first of 28 double-shell radioactive waste storage tanks constructed at the U. S. Department of Energy’s Hanford Site, near Richland, WA. The tank was completed in 1970, and entered service in 1971. In August, 2012, an accumulation of material was discovered at two sites on the floor of the annulus that separates the primary tank from the secondary liner. The material was sampled and determined to originate from the primary tank. This paper summarizes the changes in leak behavior that have occurred during the past two years, inspections to determine the capability of the secondary liner to continue safely containing the leakage, and the initial results of testing to determine the leak mechanism.
Tank AY-102 was the first of 28 double-shell radioactive waste storage tanks constructed at the U.S. Department of Energy's Hanford Site, near Richland, WA. The tank was completed in 1970, and entered service in 1971. In August, 2012, an accumulation of material was discovered at two sites on the floor of the annulus that separates the primary tank from the secondary liner. The material was sampled and determined to originate from the primary tank. This paper summarizes the changes in leak behavior that have occurred during the past two years, inspections to determine the capability of the secondary liner to continue safely containing the leakage, and the initial results of testing to determine the leak mechanism. (authors)
Up to this point, ultrasonic inspection-based condition data has only been available for double-shell tank (DST) sidewalls because direct inspection access to the primary tank bottom is limited to vent duct channels in an insulating refractory pad that the primary tank rests on. Probe access through the air slot would provide the opportunity to get information about the condition of the bottom of the primary tank, but it is a challenge to deploy a crawling robot that is capable of performing nondestructive ultrasonic and visual inspection through confined air slots. As such, a conceptual prototype of a deployable inspection robot system to enable ultrasonic and visual inspection for DST base through ventilation ducts was designed and fabricated. This prototype dual robot system consisting of the AnnulusBot and the MouseBot can be integrated with nondestructive evaluation (NDE) sensors to inspect and examine the physical properties of the underside of DSTs to enable status assessment. The AnnulusBot was designed to carry the MouseBot and to be deployed to the annulus space through a riser. To deploy the MouseBot to every ventilation channel in the annulus, the arm consisting of a boom and a forearm was used to place the MouseBot on the underside of the tank. The AnnulusBot used segmented wheels enable to traverse pipes and other potential obstacles. The cable management system utilized motorized wheels to feed the cable into the ventilation channel. This would reduce the amount of work that the MouseBot would have to do during inspection. This feeding mechanism would also be used to retrieve the MouseBot at the end of its inspection. Additionally, if the MouseBot fails, this mechanism would be used for retrieval. Once deployed, the MouseBot navigates to the center of the tank via the air ventilation channel beneath the inner shell (the primary tank) while inspecting the space. The MouseBot is then retrieved from the channel by a combination of its own drive power and the AnnulusBot retracting the attached umbilical cord. Compare with the AnnulusBot, the physical dimensional limitations of the MouseBot were a greater challenge. As the surface state of the concrete of the air channels could have variable texture, and may contain debris, it was decided not to travel along this surface. The ceiling of these channels is carbon steel and can be utilized throughout the channel. To use this travel surface, magnetic wheels were employed. A foreseeable problem with the use of magnets on this surface, is that they would preclude the use of eddy currents sensors. However, other technologies like ultrasonic technology sensors should be unaffected. Laboratory scale test was performed on a mock-up single wedge of the refractory pad to evaluate maneuverability of the MouseBot. The electronic components for the prototype would work in the ranges of 150-185 deg. F (65.6-85 deg. C). Both the AnnulusBot and MouseBot will be subject to constant radiation. All major printed circuit board (PCB) microcontroller components were designed to be situated outside of the annulus space and inside the main control panel to avoid radiation-induced failure. As future work, electronic components including the Arduinos that used Atmel commercial microcontrollers will be replaced with the high temperature rated Atmel microcontrollers so that the robots can be operated reliably at ambient temperatures up to 200 deg. F (93.3 deg. C). In addition, the robots will be service life tested to evaluate performance at elevated temperature and under gamma irradiation. (authors)