Search NASA⌕ Search

SEARCH · Search NASA

Results for “Drug Design”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Automatic Detection of Seizures with Applications

There are an estimated two million people with epilepsy in the United States. Many of these people do not respond to anti-epileptic drug therapy. Two devices can be developed to assist in the treatment of epilepsy. The first is a microcomputer-based system designed to process massive amounts of electroencephalogram (EEG) data collected during long-term monitoring of patients for the purpose of diagnosing seizures, assessing the effectiveness of medical therapy, or selecting patients for epilepsy surgery. Such a device would select and display important EEG events. Currently many such events are missed. A second device could be implanted and would detect seizures and initiate therapy. Both of these devices require a reliable seizure detection algorithm. A new algorithm is described. It is believed to represent an improvement over existing seizure detection algorithms because better signal features were selected and better standardization methods were used.

Olsen, Dale E.↗

Spinoff 2011

Topics include: Bioreactors Drive Advances in Tissue Engineering; Tooling Techniques Enhance Medical Imaging; Ventilator Technologies Sustain Critically Injured Patients; Protein Innovations Advance Drug Treatments, Skin Care; Mass Analyzers Facilitate Research on Addiction; Frameworks Coordinate Scientific Data Management; Cameras Improve Navigation for Pilots, Drivers; Integrated Design Tools Reduce Risk, Cost; Advisory Systems Save Time, Fuel for Airlines; Modeling Programs Increase Aircraft Design Safety; Fly-by-Wire Systems Enable Safer, More Efficient Flight; Modified Fittings Enhance Industrial Safety; Simulation Tools Model Icing for Aircraft Design; Information Systems Coordinate Emergency Management; Imaging Systems Provide Maps for U.S. Soldiers; High-Pressure Systems Suppress Fires in Seconds; Alloy-Enhanced Fans Maintain Fresh Air in Tunnels; Control Algorithms Charge Batteries Faster; Software Programs Derive Measurements from Photographs; Retrofits Convert Gas Vehicles into Hybrids; NASA Missions Inspire Online Video Games; Monitors Track Vital Signs for Fitness and Safety; Thermal Components Boost Performance of HVAC Systems; World Wind Tools Reveal Environmental Change; Analyzers Measure Greenhouse Gasses, Airborne Pollutants; Remediation Technologies Eliminate Contaminants; Receivers Gather Data for Climate, Weather Prediction; Coating Processes Boost Performance of Solar Cells; Analyzers Provide Water Security in Space and on Earth; Catalyst Substrates Remove Contaminants, Produce Fuel; Rocket Engine Innovations Advance Clean Energy; Technologies Render Views of Earth for Virtual Navigation; Content Platforms Meet Data Storage, Retrieval Needs; Tools Ensure Reliability of Critical Software; Electronic Handbooks Simplify Process Management; Software Innovations Speed Scientific Computing; Controller Chips Preserve Microprocessor Function; Nanotube Production Devices Expand Research Capabilities; Custom Machines Advance Composite Manufacturing; Polyimide Foams Offer Superior Insulation; Beam Steering Devices Reduce Payload Weight; Models Support Energy-Saving Microwave Technologies; Materials Advance Chemical Propulsion Technology; and High-Temperature Coatings Offer Energy Savings.

Source record↗

Improved Devices for Collecting Sweat for Chemical Analysis

Improved devices have been proposed for collecting sweat for biochemical analysis - especially for determination of the concentration of Ca2+ ions in sweat as a measure of loss of Ca from bones. Unlike commercially available sweat-collection patches used previously in monitoring osteoporosis and in qualitative screening for some drugs, the proposed devices would not allow evaporation of the volatile chemical components (mostly water) of sweat. Moreover, the proposed devices would be designed to enable determination of the volumes of collected sweat. From these volumes and the quantities of Ca(2+) and/or other analytes as determined by other means summarized below, one could determine the concentrations of the analytes in sweat. A device according to the proposal would be flexible and would be worn like a commercial sweat-collection patch. It would be made of molded polydimethylsiloxane (silicone rubber) or other suitable material having properties that, for the purpose of analyzing sweat, are similar to those of glass. The die for molding the silicone rubber would be fabricated by a combination of lithography and electroplating. The die would reproducibly form, in the silicone rubber, a precisely defined number of capillary channels per unit area, each channel having a precisely defined volume. Optionally, electrodes for measuring the Ca(2+) content of the sweat could be incorporated into the device. The volume of sweat collected in the capillary channels of the device would be determined from (1) the amount of light or radio waves of a given wavelength absorbed by the device and (2) the known geometry of the array of capillary channels. Then, in one of two options, centrifugation would be performed to move the sweat from the capillary tubes to the region containing the electrodes, which would be used to measure the Ca(2+) content by a standard technique. In the other option, centrifugation would be performed to remove the sweat from the device to make the sweat available to other analytical instruments for measuring concentrations of substances other than Ca(2+).

Feedback, Daniel L.↗

Improved Devices for Collecting Sweat for Chemical Analysis

Improved devices have been proposed for collecting sweat for biochemical analysis especially for determination of the concentration of Ca2+ ions in sweat as a measure of loss of Ca from bones. Unlike commercially available sweat-collection patches used previously in monitoring osteoporosis and in qualitative screening for some drugs, the proposed devices would not allow evaporation of the volatile chemical components (mostly water) of sweat. Moreover, the proposed devices would be designed to enable determination of the volumes of collected sweat. From these volumes and the quantities of Ca2+ and/or other analytes as determined by other means summarized below, one could determine the concentrations of the analytes in sweat. A device according to the proposal would be flexible and would be worn like a commercial sweat-collection patch. It would be made of molded polydimethylsiloxane (silicone rubber) or other suitable material having properties that, for the purpose of analyzing sweat, are similar to those of glass. The die for molding the silicone rubber would be fabricated by a combination of lithography and electroplating. The die would reproducibly form, in the silicone rubber, a precisely defined number of capillary channels per unit area, each channel having a precisely defined volume. Optionally, electrodes for measuring the Ca2+ content of the sweat could be incorporated into the device. The volume of sweat collected in the capillary channels of the device would be determined from (1) the amount of light or radio waves of a given wavelength absorbed by the device and (2) the known geometry of the array of capillary channels. Then, in one of two options, centrifugation would be performed to move the sweat from the capillary tubes to the region containing the electrodes, which would be used to measure the Ca2+ content by a standard technique. In the other option, centrifugation would be performed to remove the sweat from the device to make the sweat available to other analytical instruments for measuring concentrations of substances other than Ca2+.

Feeback, Daniel L.↗

Bisphosphonates as a Countermeasure to Space Flight Induced Bone Loss

This poster reviews the possibility of using Bisphosphonates to counter the bone loss that is experienced during space flight. The Hypothesis that is tested in this experiment is that the combined effect of anti-resorptive drugs plus in-flight exercise regimen will attenuate space flight induced loss in bone mass and strength and reduce renal stone risk. The experiment design, the status and the results are described.

LeBlanc, A.↗

Bioavailability and Pharmacodynamics of Promethazine in Human Subjects

The acute effects of exposure to microgravity include the development of space motion sickness, which usually requires therapeutic intervention. The current drug of choice, promethazine (PMZ), is available to astronauts in three different dosage forms during space flight; its side effects include nausea, dizziness, sedation and impaired psychomotor performance. This ground-based study is designed to validate flight-suitable methods for pharmacodynamic evaluation of PMZ and to estimate bioavailability and pharmacodynamics of PMZ. Experimental design consists of intramuscular administration of three doses of PMZ (12.5,25 and 50 mg) and placebo in a randomized double blind fashion to human subjects and collecting blood, urine and saliva samples for 72 h. Subjects also complete cognitive performance test batteries, WinSCAT (Windows based Space Cognitive Assessment Test) and ARES (ANAM Readiness Evaluation System). Preliminary results indicate a significant relationship (p=9.88e-05) between circulating PMZ levels and cognitive performance parameters. Time to accurately complete memory tasks increases significantly with concentrations; higher concentrations also increase response time and decrease accuracy of substitution and matching tasks. AUC and half-life estimates for PMZ ranged between 0.12 and 1.7 mg.h/L and 15 and 50 h, respectively. These preliminary results indicate that PMZ may exhibit dose-dependent pharmacokinetics in humans; also, WinSCAT and ARES are sensitive for pharmacodynamic assessment of PMZ, and may be applicable for assessing the pharmacodynamics of other neurocognitive drugs.

Boyd, J. L.↗

Catecholaminergic responses to stressful motion stimuli, scopolamine plus amphetamine, and dexamethasone

Peripheral levels of epinephrine (EPI) and neoepinephrine (NE) generally rise following stressful motion stimuli. Effective anti-motion sickness drugs, scopolamine plus, d-amphetamine (S/D) and dexamthasone (DEX) modulate release of EPI and NE. This modulation may be of etiological relevance. Methods: Severe nausea was induced by exposure to coriolis simulation using a rotating chair. Chronic administration of S/D (0.4 and 5 mg/da) DEX (3 mg/day) and placebo preceded coriolis simulation. EPI and NE were measured immediately before and after simulation. A double-blind crossover design was used. Results: Nausea-induced elevations of EPI (2.5 fold, p less than .01) and NE were not diminished upon repeated exposure and adaptation to the stressor. Subjects with more pronounced elevations of EPI following simulation displayed higher resistance to stressful motion (p less .05). Alteration of peripheral catechlomaine levels following drug suggested that motion sickness was not mediated by peripheral catechlolamine receptor simulation. EPI and NE levels were 2.8 and 3.6-fold higher (p less than .03 and .01) after nausea without DEX treatment. DEX loading halved pre-stress levels of EPI and NE (p less than .05). Conclusions: Marked differences were noted in individual responses to drug and systematic responses of EPI and NE. It is possible that the responses of EPI to motion sickness may predict resistance to stressful motion and represent a peripheral manifestation of some as yet unknown central event of etiologic relevance.

Kohl, R. L.↗

Prognostic significance of electrical alternans versus signal averaged electrocardiography in predicting the outcome of electrophysiological testing and arrhythmia-free survival

OBJECTIVE: To investigate the accuracy of signal averaged electrocardiography (SAECG) and measurement of microvolt level T wave alternans as predictors of susceptibility to ventricular arrhythmias. DESIGN: Analysis of new data from a previously published prospective investigation. SETTING: Electrophysiology laboratory of a major referral hospital. PATIENTS AND INTERVENTIONS: 43 patients, not on class I or class III antiarrhythmic drug treatment, undergoing invasive electrophysiological testing had SAECG and T wave alternans measurements. The SAECG was considered positive in the presence of one (SAECG-I) or two (SAECG-II) of three standard criteria. T wave alternans was considered positive if the alternans ratio exceeded 3.0. MAIN OUTCOME MEASURES: Inducibility of sustained ventricular tachycardia or fibrillation during electrophysiological testing, and 20 month arrhythmia-free survival. RESULTS: The accuracy of T wave alternans in predicting the outcome of electrophysiological testing was 84% (p < 0.0001). Neither SAECG-I (accuracy 60%; p < 0.29) nor SAECG-II (accuracy 71%; p < 0.10) was a statistically significant predictor of electrophysiological testing. SAECG, T wave alternans, electrophysiological testing, and follow up data were available in 36 patients while not on class I or III antiarrhythmic agents. The accuracy of T wave alternans in predicting the outcome of arrhythmia-free survival was 86% (p < 0.030). Neither SAECG-I (accuracy 65%; p < 0.21) nor SAECG-II (accuracy 71%; p < 0.48) was a statistically significant predictor of arrhythmia-free survival. CONCLUSIONS: T wave alternans was a highly significant predictor of the outcome of electrophysiological testing and arrhythmia-free survival, while SAECG was not a statistically significant predictor. Although these results need to be confirmed in prospective clinical studies, they suggest that T wave alternans may serve as a non-invasive probe for screening high risk populations for malignant ventricular arrhythmias.

Non-NASA Center↗

The Use of Heavy Ion Radiation as an Analog for Space Radiation Environment and Its Effects on Drug Stability

While it is common knowledge that electromagnetic radiation such as x-rays and gamma rays affect physical-chemical characteristics (PC) of compounds in addition to their toxic and mutagenic effects on biological systems, there are no reports on the effects of cosmic radiation encountered during space missions on stability of pharmaceuticals. Alterations in PC of drug formulations can adversely affect treatment with medications in space. Preliminary evaluation of stability and shelf-life of select pharmaceuticals (12) flown on space missions revealed that 37% and 40% of the formulations failed to meet USP requirements after shuttle and ISS flights, respectively. Based on these results, the current investigation is designed to examine the effect of proton (P) and heavy ion (Fe) radiation on 20 pharmaceutical preparations flown aboard the shuttle and ISS. The objectives of this project are: 1) Examine susceptibility of pharmaceuticals to short acute bouts of high intensity ionizing radiation species encountered during space flights; 2) Estimate extent of degradation of susceptible formulations as a function of intensity of each beam (P & Fe); and 3) compare and contrast the effects of single beam irradiation to that of a combined beam (P + Fe) that simulates space craft environment on drug stability. Irradiations were conducted at the Brookhaven National Laboratories (BNL) with beam strengths of 10 cGy, 10 or 50Gy of P and Fe beams separately. Preliminary evaluation of results revealed a reduction in the chemical content of label claim ranging 12-55 % for Augmentin, 7% for promethzine tablets and 9% for ciprofloxacin ointment. These results are in agreement, although less in magnitude than those observed during space flight and after gamma irradiation.

Vaksman, Z.↗

The Pathway to a Safe and Effective Medication Formulary for Exploration Spaceflight

PURPOSE: Exploration space missions pose several challenges to providing a comprehensive medication formulary designed to accommodate the size and space limitations of the spacecraft; while addressing the individual medications needs and preferences of the Crew; the negative outcome of a degrading inventory over time, the inability to resupply before expiration dates; and the need to properly forecast the best possible medication candidates to treat conditions that will occur in the future. METHODS: The Pharmacotherapeutics Discipline has partnered with the Exploration Medical Capabilities (ExMC) Element to develop and propose a research pathway that is comprehensively focused on evidence-based models and theories, as well as on new diagnostic tools and treatments or preventive measures aimed at closure of the Med02 “Pharmacy” Gap; defined in the Human Research Program’s (HRP) risk-based research strategy. The Med02 Gap promotes the challenge to identify a strategy to ensure that medications used to treat medical conditions during exploration space missions are available, safe, and effective. It is abundantly clear that pharmaceutical intervention is an essential component of risk management planning for astronaut healthcare during exploration space. However, the quandary still remains of how to assemble a formulary that is comprehensive enough to prevent or treat anticipated medical events; and is also chemically stable, safe, and robust enough to have sufficient potency to last for the duration of an exploration space mission. In cases where that is not possible, addressing this Gap requires exploration of novel drug development techniques, dosage forms, and dosage delivery platforms that enhance chemical stability as well as therapeutic effectiveness. RESULTS: The proposed research pathway outlines the steps, processes, procedures, and a research portfolio aimed at identifying a capability that will provide a safe and effective pharmacy for any specific exploration Design Reference Mission (DRM). The proposed approach to building this research portfolio is to seek research projects that concentrate on four major focus areas; (1) Formulary selection, (2) Formulary potency and shelf life, (3) Formulary safety and toxicity, and (4) Novel technology and innovation such as portable real-time chemical analysis innovative drug therapies and dosage and delivery platforms. CONCLUSION: The research pathway has been completed and presented to the HRP. In spring 2017, it is scheduled to be reviewed by a panel of pharmaceutical and clinical experts that will evaluate the scientific merit and operational feasibility of the research pathway, as well as make suggestions for any warranted additions or improvements. Once finalized, the ExMC Element will proceed with the execution of this research pathway with the goal of gathering as much data, and learning as much as possible, to provide a safe and effective pharmaceutical formulary for use during exploration missions.

Daniels, V. R.↗

Taxane recovery from cells of Taxus in micro- and hypergravity

Cell suspension cultures of Taxus cuspidata produce taxanes that are released from the outer surface of cells into the culture medium as free and bound alkaloids. Paclitaxel (Taxol (TM)), is an anti-cancer drug in short supply. It has a taxane ring derived from baccatin III and a C-13 phenylisoserine side-chain. This drug is produced over a wide range of gravitational forces. Monoclonal and polyclonal antibodies to paclitaxel, baccatin III, and the C-13 phenylisoserine side chain were combined in multiple-labeling studies to localize taxanes and paclitaxel on cell surfaces or on particles released into the culture medium. Bioreactor vessel design altered the composition of taxanes recovered from cells in simulated microgravity. At 10(-2) and 2x10(-4)g, taxane recovery was reduced but biomass growth and percent paclitaxel was significantly increased. At 1 to 24g, growth was reduced with a significant recovery of total taxanes with low percent paclitaxel. Bound paclitaxel was also localized in endonuclease-rich fragmenting nuclei of individual apoptotic cells. A model is presented comprising TCH (touch) genes encoding enzymes that modify taxane-bearing xylan residues in cell walls, the calcium-sensing of gravitational forces by the cytoplasm, and the predisposition of nuclei to apoptosis. This integrates the adaptive physiological and biochemical responses of drug-producing genomes with gravitational forces.

Plants, Medicinal/chemistry/cytology↗

Development of an Antimicrobial Susceptibility Testing Method Suitable for Performing During Space Flight

Very little is known regarding the affects of the microgravity environment of space flight upon the action of antimicrobial agents on bacterial pathogens. This study was undertaken to develop a simple method for conducting antibacterial susceptibility tests during a Space Shuttle mission. Specially prepared susceptibility test research cards (bioMerieux Vitek, Hazelwood, MO) were designed to include 6-11 serial two-fold dilutions of 14 antimicrobial agents, including penicillins, cephalosporins, a Beta-lactamase inhibitor, vancomycin, erythromycin, tetracycline, gentamicin, ciprofloxacin, and trimethoprim/sulfamethoxazole. Minimal inhibitory concentrations (MICS) of the drugs were determined by visual reading of color endpoints in the Vitek research cards made possible by incorporation of a colorimetric growth indicator (alamarBlue(Trademark), Accumed International, Westlake, OH). This study has demonstrated reproducible susceptibility results when testing isolates of Staphylococcus aurezis, Group A Streptococcus, Enterococcusfaecalis, Escherichia coli (beta-lactamase positive and negative strains), Klebsiella pneumoniae, Enterobacter cloacae, and Pseudomoiias aeruginosa. In some instances, the MICs were comparable to those determined using a standard broth microdilution method, while in some cases the unique test media and format yielded slightly different values, that were themselves reproducible. The proposed in-flight experiment will include inoculation of the Vitek cards on the ground prior to launch of the Space Shuttle, storage of inoculated cards at refrigeration temperature aboard the Space Shuttle until experiment initiation, then incubation of the cards for 18-48 h prior to visual interpretation of MICs by the mission's astronauts. Ground-based studies have shown reproducible MICs following storage of inoculated cards for 7 days at 4-8 C to accommodate the mission's time schedule and the astronauts' activities. For comparison, ground-based control (normal gravity) MIC values will be generated by simultaneous inoculation and incubation of a second set of test cards in a laboratory at the launch site. This procedure can provide a safe and compact experiment that should yield new information on the affects of microgravity on the biological activities of various classes of antibiotics.

Jorgensen, James H.↗

Structural Evaluation of Radially Expandable Cardiovascular Stents Encased in a Polyurethane Film

A method of encasing cardiovascular stents with an expandable polyurethane coating has been developed to provide a smooth homogeneous inner wall allowing for a confluent growth of endothelial cells. In this design, the metal wire stent structure is completely covered by the polyurethane film minimizing biocorrosion of the metal (stainless steel or nitinol), and providing a homogeneous surface for surface treatment and incorporation of various eluting drugs to prevent platelet aggregation while supporting endothelialization. The polyurethane surface was treated with a helium plasma for sterilization and promotes growth of cells. The paper details the performance of the coated film to expand with the metal stent up to 225 % during deployment. We present stress/strain behavior of polyurethane films, and subsequent plasma treatment of the surface and the adhesion of the coating to the stent structure upon expansion. A film of less than 25 tm was found to be sufficient for corrosion resistance and flexibility without producing any excess stress on the stent structure. Straining the film to 225 % and plasma modification did not affect the mechanical and surface properties while allowing for improved biocompatibility as determined by the critical surface tension, surface chemistry, and roughness.

Trigwell, Steve↗

Three-Dimensional Cell Culture Models for Infectious Disease and Drug Development

Three-dimensional (3-D) cell cultures hold enormous potential to advance our understanding of infectious disease and to effectively translate basic cellular research into clinical applications. Using novel NASA bioreactor technology, the rotating wall vessel (RWV), we have engineered physiologically relevant 3-D human tissue culture models for infectious disease studies. The design of the RWV is based on the understanding that organs and tissues function in a 3-D environment, and that this 3-D architecture is critical for the differentiated form and function of tissues in vivo. The RWV provides large numbers of cells which are amenable to a wide variety of experimental manipulations and provides an easy, reproducible, and cost-effective approach to enhance differentiated features of cell culture models.

Nickerson, Cheryl A.↗

The 'Pro-Drug' RibCys Decreases The Mutagenicity of High LET Radiation in Cultured Mammalian Cells

We have initiated studies aimed at reducing the mutational effects of high LET radiation such as Fe-56 ions and C-12 ions with certain drugs. The mutagenicity of high LET (143 keV/micrometer) Fe-56 or C-12 ions (LET = 100 keV/micrometer) was quantified at the CD59 locus of human-hamster hybrid AL cells. RibCys [2,S)-D-ribo-(1',2',3',4'- Tetrahydroxybutyl)-thiazolidine-4(R)-ca riboxylic acid], formed by condensation of L-cysteine with D-ribose, is designed so that the sulfhydryl amino acid L-cysteine is released intracellularly via nonenzymatic ring opening and hydrolysis leading to increased levels of glutathione (GSH). RibCys (4 or 10 mM), present during irradiation and a few hours post-irradiation, significantly decreased the yield of CD59(-) mutants induced by radiation. RibCys did not affect the clonogenic survival of irradiated cells, nor was it mutagenic itself. These results, together with the minimal side effects reported in mice and pigs, indicate that RibCys may be useful, perhaps even when used prophylactically, in reducing the load of mutations created by high LET radiation in astronauts or other exposed individuals. RibCys is an attractive drug that may reduce the risk of carcinogenesis in people exposed to high LET radiation.

Lenarczyk, M.↗

Optimal sampling theory and population modelling - Application to determination of the influence of the microgravity environment on drug distribution and elimination

The optimal sampling theory is evaluated in applications to studies related to the distribution and elimination of several drugs (including ceftazidime, piperacillin, and ciprofloxacin), using the SAMPLE module of the ADAPT II package of programs developed by D'Argenio and Schumitzky (1979, 1988) and comparing the pharmacokinetic parameter values with results obtained by traditional ten-sample design. The impact of the use of optimal sampling was demonstrated in conjunction with NONMEM (Sheiner et al., 1977) approach, in which the population is taken as the unit of analysis, allowing even fragmentary patient data sets to contribute to population parameter estimates. It is shown that this technique is applicable in both the single-dose and the multiple-dose environments. The ability to study real patients made it possible to show that there was a bimodal distribution in ciprofloxacin nonrenal clearance.

Drusano, George L.↗

Validation of a Best-Fit Pharmacokinetic Model for Scopolamine Disposition after Intranasal Administration

An intranasal gel formulation of scopolamine (INSCOP) was developed for the treatment of Motion Sickness. Bioavailability and pharmacokinetics (PK) were determined per Investigative New Drug (IND) evaluation guidance by the Food and Drug Administration. Earlier, we reported the development of a PK model that can predict the relationship between plasma, saliva and urinary scopolamine (SCOP) concentrations using data collected from an IND clinical trial with INSCOP. This data analysis project is designed to validate the reported best fit PK model for SCOP by comparing observed and model predicted SCOP concentration‐time profiles after administration of INSCOP.

Wu, L.↗

Preliminary Results Using Galvanic Vestibular Reduction as a Non-Pharmaceutical Tool for Motion Sickness Mitigation

Introduction: Alterations in vestibular sensory processing following G-transitions lead to motion sickness and spatial disorientation upon return to Earth’s gravity. The use of non-pharmaceutical mitigation for motion sickness has several potential advantages over drug treatment options. The purpose of this study was to validate a non-pharmaceutical tool using galvanic vestibular reduction (GVR) to mitigate G-transitional induced motion sickness and spatial disorientation. Methods: Using a repeated measures counter-balanced design, motion sickness and perception are obtained during Coriolis cross-coupling stimuli on a rotating chair across three GVR treatment interventions: throughout stimulus testing (prevention), following symptom onset (rescue), and placebo control. Subjects perform up to 10 sets of pitch head movements during constant rotation. For each set, head movement is cued every 10 seconds, alternating between pitch forward (chin resting to chest) and pitch backward (head upright) for a total of 7 forward and backward movements. During each head movement, subjects are asked to use a joystick to record the magnitude of their perceived rotation along all three axes. During the 2-minute pause between sets, motion sickness symptom scoring was obtained using the Pensacola Diagnostic Index and subject discomfort (0-20) ratings. Performance on a sensorimotor and cognitive test battery is measured during a fourth session to map changes in GVR level with functional performance. Results: Fifteen of 30 subjects have completed testing to date. Preliminary findings suggest GVR may be more effective in reducing symptoms in subjects who self-report less susceptibility on a pre-test motion sickness susceptibility questionnaire. Based on the joystick measures, GVR significantly reduces both the magnitude (mean 22% - 34%) and duration (mean 42% - 49%) of perceived roll and pitch sensation with head movements during constant rotation. It is important to note that comparable levels of GVR (up to 2.5mA) does not impair performance on a functional test battery including mobility and balance tasks. Discussion: Our preliminary findings suggest GVR may be useful in reducing disorienting roll and pitch illusions associated with Coriolis cross-coupling stimuli. While transfer to post-flight treatment will need to be validated, the potential advantages of our non-pharmaceutical countermeasure approach would be to provide rapid therapeutic effect while allowing continuous titration of GVR amplitude during recovery to maintain operational performance.

Gaurav Pradhan↗