Search NASA⌕ Search

SEARCH · Search NASA

Results for “ECCS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Development of sustainable low carbon Engineered Cementitious Composites with waste polyethylene fiber, sisal fiber and carbonation curing

Engineered cementitious composites (ECC) is an advanced fiber-reinforced cementitious composite with high tensile ductility. However, the binder and fiber system in ECC incur high economic and environmental cost. In this study, a low carbon ECC was developed by substituting virgin polyethylene fiber with waste polyethylene fiber (WPE) from waste marine fishing nets. Carbonation curing was applied to further reduce embodied carbon footprint via direct CO 2 mineralization. This research examined the low carbon ECC’s mechanical properties, including compressive strength and tensile strength and ductility. The CO 2 footprint and material costs of ECC were also investigated. The objective was to develop an ECC competitive to normal concrete economically and environmentally while maintain the unique ductile performance of ECC. Results suggest that carbonation-cured WPE reinforced ECC possesses 50% of the CO 2 footprint and 37% of the cost of traditional concrete. Meanwhile, this low carbon ECC maintains at least 4 MPa tensile strength and 6% tensile ductility. This research demonstrates the feasibility of developing construction materials with low environmental impact while maintaining high performance for civil infrastructure applications. As a result, the adoption of WPE in ECC provides a plausible pathway to recycle marine waste into the construction industry that urgently needs to be decarbonized.

42 ENGINEERING↗

Storing Co 2 in Built Infrastructure: Co 2 Carbonation of Precast Concrete Products

The overall objective of the proposed study was to advance the technical understanding of CO 2 incorporation into novel cementitious materials for the development of high value products that provide a net reduction in carbon emissions. This project combined two primary phases of research that addressed technical barriers related to (i) optimizing CO 2 storage capability of cementitious materials, (ii) evaluating and enhancing physical properties of novel carbonated materials, and (iii) assessing the reductions in life cycle CO 2 emissions attributed to CO 2 carbonation of precast cementitious materials. Engineered cementitious composites (ECC) are a class of highly ductile concrete composites that have been shown to be very durable when used in the built environment. CO 2 carbonation of ECC was examined in this study and it was found that precast ECC specimens could sequester up to 35% CO 2 by cement mass after 24 hours of curing at a CO 2 pressure of 0.5 MPa and 23°C and had a strain capacity of 3%. Carbonation conditions were optimized at the bench-scale and then utilized to create full-scale CO 2 -cured ECC railroad ties that were field tested on a train track. Rail ties were selected for this initial assessment of CO 2 storage in precast concrete materials due to the large market for concrete ties in the railroad industry. Although the full-scale rail ties passed all of the required American Railway Engineering and Maintenance-of-Way Association qualifying mechanical tests, on-track testing of the CO 2 -cured ECC rail ties was unsuccessful due to fiber alignment in the ECC the during the rail tie casting process which prevented the material from achieving the expected level of strain capacity. This result highlights the challenge in scaling up bench-scale processes to full-scale product manufacturing and requires additional investigation into the casting process of large-scale infrastructure elements using ECC combined with carbonation curing. Life cycle assessment of a CO 2 -cured ECC rail tie versus a traditional concrete rail tie indicates that the ECC tie can have lifecycle carbon savings of between 11% and 51% depending on how much longer its useful lifetime is compared to traditional concrete rail ties. Both carbon and cost savings are driven by a reduction in the need to replace broken rail ties, so the key factor is the extent to which a CO 2 -cured ECC rail tie will have increased lifetime durability compared to alternative rail ties.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Sulphate resistance of low‐clinker engineered cementitious composites examined by MicroXRF imaging

Abstract Engineered cementitious composites (ECC) are a class of high‐performing fibre‐reinforced cementitious materials recognised for their increased ductility and durability compared to conventional cement‐based materials, owing to their autogenously controlled tight crack widths, even when subjected to high strains. To reduce ECC's environmental impact, this research examines the use of a low‐clinker binder − limestone‐calcined clay cement (LC3) − as an alternative to portland cement (PC), along with fly ash to further reduce the clinker proportion and the embodied CO 2 of the formulations. In conventional concrete, LC3 hydrates to a denser microstructure resulting from the synergistic reaction between limestone and calcined clay. At the lower water contents typical of ECC and with the presence of fly ash, the influence of the binder composition on the microstructure is difficult to anticipate. To examine the influence of these compositional variables on microstructure, permeability and durability, the sulphate resistance of LC3‐based ECC is explored. Specifically, the ECC‐LC3 blends are designed with high clinker replacement rate of 75% by mass of binder and contain either conventional fly ash or reclaimed fly ash at 50% by mass of binder. Expansion of ECC‐LC3 samples subjected to standard sodium sulphate test conditions was measured up to 12 months and the depth of penetration of sulphates into the ECC‐LC3 of varying compositions was quantified using micro‐X‐Ray Fluorescence (microXRF) imaging and modelling. The expansion results show that the ECC‐LC3 formulations performed better than the PC samples and can provide adequate resistance to external sulphate attack, even when reclaimed fly ashes are used in place of the conventional ash. In addition, the shallow penetration of sulphate into these cementitious composites demonstrates the low diffusion coefficients values that were determined using the quantitative data from MicroXRF imaging.

Microscopy↗

Novel ductile wellbore cementitious composite for geologic CO 2 storage

CO 2 leakage through damaged wellbore cement sheaths is a major risk of geologic CO 2 storage (GCS), as conventional wellbore cement is brittle and can be damaged due to acid attack and downhole stresses during CO 2 injection. Here we examine a novel fiber-reinforced engineered cementitious composite (ECC) proposed as a substitute to conventional wellbore cement due to its superior ductility and intrinsic crack width control. ECC and conventional wellbore cement coupons were exposed to water in equilibrium with CO 2 at 50 °C and 10 MPa. The samples were retrieved after several days and their mechanical performance was evaluated using a four-point bending test, microhardness, and compressive strength analyses. Optical microscopy and mercury intrusion porosimetry were used to characterize the progression of the carbonation front and pore structures of the specimens. Control experiments were conducted under the same temperature and pressure conditions but with a N 2 headspace to isolate the impact of CO 2 . It was found that carbonation increased the ultimate flexural strength of ECC but decreased its ductility. However, the ductility of carbonated ECC remained higher than that of conventional wellbore cements that exhibited brittle failure under all test conditions. Additionally, ECC exhibited minimal material loss and continued resistance to deformation in comparison to conventional wellbore cements. This suggests that while the exposure of ECC to CO 2 will alter its mechanical properties, altered ECC will continue to exhibit mechanical performance superior to conventional wellbore cement, and therefore shows promise as a highly durable wellbore cementing material for GCS applications.

58 GEOSCIENCES↗

Life cycle assessment of railway ties fabricated with ductile cementitious composites and carbonation curing

This paper evaluates the lifecycle economic and environmental benefits of implementing CO 2 utilization and storage within advanced engineered cementitious composite (ECC) railway ties. Using CO 2 -treated ECC ties can yield lifecycle benefits primarily due to enhanced material properties – increased lifespan in this case – instead of due to the stored CO 2 that would otherwise enter the atmosphere. Sequestration-based policies such as 45Q in the United States would therefore not incentivize deployment of ECC railway ties, despite their considerable CO 2 avoidance opportunities. To reach these conclusions, cradle-to-grave lifecycle models were developed for ECC ties and conventional concrete ties and evaluated under 1000 possible use-phase scenarios. The models incorporated premature tie failures – consistent with real-world observations – that were used to study a wide range of non-linear impacts arising from the random nature of tie failures and replacements. The results show that past studies that neglected premature failure of ties may have underestimated lifecycle greenhouse gas (GHG) emissions of concrete rail ties by nearly three times. Overall, servicing a track with ECC ties instead of concrete ties can reduce the lifecycle costs and GHG emissions by 12% and 21% respectively, based on median values of 1000 model run results. The expected benefits would be larger for entities like Amtrak that plan to expand concrete tie infrastructure despite significant challenges with premature concrete tie failures. Furthermore, the results of this study suggest that the lifespan of ECC ties needs to be at least 25% longer than concrete ties to achieve net lifecycle benefits. The possibility of this should be tested and confirmed under real-world conditions.

42 ENGINEERING↗

Extensible Computational Chemistry Environment

ECCE provides a sophisticated graphical user interface, scientific visualization tools, and the underlying data management framework enabling scientists to efficiently set up calculations and store, retrieve, and analyze the rapidly growing volumes of data produced by computational chemistry studies. ECCE was conceived as part of the Environmental Molecular Sciences Laboratory construction to solve the problem of researchers being able to effectively utilize complex computational chemistry codes and massively parallel high performance compute resources. Bringing the power of these codes and resources to the desktops of researcher and thus enabling world class research without users needing a detailed understanding of the inner workings of either the theoretical codes or the supercomputers needed to run them was a grand challenge problem in the original version of the EMSL. ECCE allows collaboration among researchers using a web-based data repository where the inputs and results for all calculations done within ECCE are organized. ECCE is a first of kind end-to-end problem solving environment for all phases of computational chemistry research: setting up calculations with sophisticated GUI and direct manipulation visualization tools, submitting and monitoring calculations on remote high performance supercomputers without having to be familiar with the details of using these compute resources, and performing results visualization and analysis including creating publication quality images. ECCE is a suite of tightly integrated applications that are employed as the user moves through the modeling process.

Source record↗

DEPOSITION TANK CORROSION TESTING FOR ENHANCED CHEMICAL CLEANING POST OXALIC ACID DESTRUCTION

An Enhanced Chemical Cleaning (ECC) process is being developed to aid in the high level waste tank closure at the Savannah River Site. The ECC process uses an advanced oxidation process (AOP) to destroy the oxalic acid that is used to remove residual sludge from a waste tank prior to closure. The AOP process treats the dissolved sludge with ozone to decompose the oxalic acid through reactions with hydroxyl radicals. The effluent from this oxalic acid decomposition is to be sent to a Type III waste tank and may be corrosive to these tanks. As part of the hazardous simulant testing that was conducted at the ECC vendor location, corrosion testing was conducted to determine the general corrosion rate for the deposition tank and to assess the susceptibility to localized corrosion, especially pitting. Both of these factors impact the calculation of hydrogen gas generation and the structural integrity of the tanks, which are considered safety class functions. The testing consisted of immersion and electrochemical testing of A537 carbon steel, the material of construction of Type III tanks, and 304L stainless steel, the material of construction for transfer piping. Tests were conducted in solutions removed from the destruction loop of the prototype ECC set up. Hazardous simulants, which were manufactured at SRNL, were used as representative sludges for F-area and H-area waste tanks. Oxalic acid concentrations of 1 and 2.5% were used to dissolve the sludge as a feed to the ECC process. Test solutions included the uninhibited effluent, as well as the effluent treated for corrosion control. The corrosion control options included mixing with an inhibited supernate and the addition of hydroxide. Evaporation of the uninhibited effluent was also tested since it may have a positive impact on reducing corrosion. All corrosion testing was conducted at 50 C. The uninhibited effluent was found to increase the corrosion rate by an order of magnitude from less than 1 mil per year (mpy) for an inhibited waste to a range of 5 to 23.4 mpy, depending on sludge chemistry. F-area-based effluents were, in general, more corrosive. Effective corrosion control measures included evaporation, hydroxide additions and mixing with supernates containing a representative supernate chemistry (5 M hydroxide and 1.5 M nitrite). Corrosion rates with these measures were generally 0.2 mpy. The A537 carbon steel was found to be susceptible to pitting when the corrosion control measure involved mixing the ECC effluent with a supernate chemistry having minimal inhibitor concentrations (0.5 M hydroxide and 0.3 M nitrite). Corrosion rates in this case were near 1 mpy.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Actual-Waste Testing of Ultraviolet Light to Augment the Enhanced Chemical Cleaning of SRS Sludge

In support of Savannah River Site (SRS) tank closure efforts, the Savannah River National Laboratory (SRNL) conducted Real Waste Testing (RWT) to evaluate Enhanced Chemical Cleaning (ECC), an alternative to the baseline 8 wt% oxalic acid (OA) chemical cleaning technology for tank sludge heel removal. ECC utilizes a more dilute OA solution (2 wt%) and an oxalate destruction technology using ozonolysis with or without the application of ultraviolet (UV) light. SRNL conducted tests of the ECC process using actual SRS waste material from Tanks 5F and 12H. The previous phase of testing involved testing of all phases of the ECC process (sludge dissolution, OA decomposition, product evaporation, and deposition tank storage) but did not involve the use of UV light in OA decomposition. The new phase of testing documented in this report focused on the use of UV light to assist OA decomposition, but involved only the OA decomposition and deposition tank portions of the process. Compared with the previous testing at analogous conditions without UV light, OA decomposition with the use of UV light generally reduced time required to reach the target of <100 mg/L oxalate. This effect was the most pronounced during the initial part of the decomposition batches, when pH was <4. For the later stages of each OA decomposition batch, the increase in OA decomposition rate with use of the UV light appeared to be minimal. Testing of the deposition tank storage of the ECC product resulted in analogous soluble concentrations regardless of the use or non-use of UV light in the ECC reactor.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Extensible Computational Chemistry Environment

ECCE provides a sophisticated graphical user interface, scientific visualization tools, and the underlying data management framework enabling scientists to efficiently set up calculations and store, retrieve, and analyze the rapidly growing volumes of data produced by computational chemistry studies. ECCE was conceived as part of the Environmental Molecular Sciences Laboratory construction to solve the problem of researchers being able to effectively utilize complex computational chemistry codes and massively parallel high performance compute resources. Bringing the power of these codes and resources to the desktops of researcher and thus enabling world class research without users needing a detailed understanding of the inner workings of either the theoretical codes or the supercomputers needed to run them was a grand challenge problem in the original version of the EMSL. ECCE allows collaboration among researchers using a web-based data repository where the inputs and results for all calculations done within ECCE are organized. ECCE is a first of kind end-to-end problem solving environment for all phases of computational chemistry research: setting up calculations with sophisticated GUI and direct manipulation visualization tools, submitting and monitoring calculations on remote high performance supercomputers without having to be familiar with the details of using these compute resources, and performing results visualization and analysis including creating publication quality images. ECCE is a suite of tightly integrated applications that are employed as the user moves through the modeling process.

Source record↗

Method and apparatus for selective and power-aware memory error protection and memory management

A method for providing selective memory error protection responsive to a predictable failure notification associated with at least one portion of a memory in a computing system includes: obtaining an active error correcting code (ECC) configuration corresponding to the portion of the memory; determining whether the active ECC configuration is sufficient to correct at least one error in the portion of the memory affected by the predictable failure notification; when the active ECC configuration is insufficient to correct the error, determining whether data corruption can be tolerated by an application running on the computing system; when data corruption cannot be tolerated by the application, determining whether a stronger ECC level is available and, if a stronger ECC level is available, increasing a strength of the active ECC configuration; and when data corruption can be tolerated, performing page reassignment and aggregation of non-critical data.

97 MATHEMATICS AND COMPUTING↗

Actual-Waste Tests of Enhanced Chemical Cleaning for Retrieval of SRS HLW Sludge Tank Heels and Decomposition of Oxalic Acid - 12256

Savannah River National Laboratory conducted a series of tests on the Enhanced Chemical Cleaning (ECC) process using actual Savannah River Site waste material from Tanks 5F and 12H. Testing involved sludge dissolution with 2 wt% oxalic acid, the decomposition of the oxalates by ozonolysis (with and without the aid of ultraviolet light), the evaporation of water from the product, and tracking the concentrations of key components throughout the process. During ECC actual waste testing, the process was successful in decomposing oxalate to below the target levels without causing substantial physical or chemical changes in the product sludge. During ECC actual waste testing, the introduction of ozone was successful in decomposing oxalate to below the target levels. This testing did not identify physical or chemical changes in the ECC product sludge that would impact downstream processing. The results from these tests confirm observations made by AREVA NP during larger scale testing with waste simulants. This testing, however, had a decreased utilization of ozone, requiring approximately 5 moles of ozone per mole of oxalate decomposed. Decomposition of oxalates in sludge dissolved in 2 wt% OA to levels near 100 ppm oxalate using ECC process conditions required 8 to 12.5 hours without the aid of UV light and 4.5 to 8 hours with the aid of UV light. The pH and ORP were tracked during decomposition testing. Sludge components were tracked during OA decomposition, showing that most components have the highest soluble levels in the initial dissolved sludge and early decomposition samples and exhibit lower soluble levels as OA decomposition progresses. The Deposition Tank storage conditions that included pH adjustment to approximately 1 M free hydroxide tended to bring the soluble concentrations in the ECC product to nearly the same level for each test regardless of storage time, storage temperature, and contact with other tank sludge material. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Determination of CO 2 capture during accelerated carbonation of engineered cementitious composite pastes by thermogravimetry

The concerns about greenhouse gas emissions have triggered investigations among the scientific community. The accelerated carbonation curing has been used as a tool to capture CO 2 at early stages of cement-based material fabrication. In a previous study, the authors quantified the amount of CO 2 captured in portland cement pastes by thermal analysis, at high relative humidity precure conditions. In the present work, the authors quantified the amount of CO 2 captured in binary pastes derived from engineered cementitious composites (ECC), a family of composites worldwide used, whose one of their features is the precure at low relative humidity conditions. Two types of ECC pastes (1.2 and 2.2) were submitted to 4 h and 24 h of accelerated carbonation after 24 h of initial hydration. Using thermogravimetry and derivative thermogravimetry, the amounts of captured CO 2 and respective carbonation degrees were quantified. Furthermore, the results showed that ECC paste 1.2 presented the highest values of captured CO 2 and carbonation degree, considering all reactive components. In contrast, ECC paste 2.2 presented the highest values of these two parameters, when considering only portland cement as reactive component. For both pastes, the hydration degrees of the carbonated samples were higher than those of the non-carbonated references, indicating that in the used operating conditions, carbonation enhances ECC paste hydration.

42 ENGINEERING↗

Optimization of matrix viscosity improves polypropylene fiber dispersion and properties of engineered cementitious composites

Engineered cementitious composites (ECC) is a durable cementitious material with high tensile ductility and strain-hardening characteristics. Although considered as a cost-effective fiber for ECC, polypropylene (PP) fiber is reportedly difficult to disperse in mortar matrix due to its high aspect ratio and hydrophobicity. In this study, the matrix viscosity of a low-carbon ECC based on limestone calcined clay cement was tailored as a variable to improve PP fiber dispersion under a pre-determined mixing protocol. The effect of matrix viscosity on the composite fresh and hardened properties was investigated experimentally. Results suggested an optimal range of matrix viscosity (10.3–11.5 Pa . s) favors the composite tensile strength and strain capacity at 28 days. At the optimal state with a 0.1 % viscosity modifying admixture (VMA)-to-binder mass ratio, PP-ECC achieved 7.0 % tensile strain capacity and 3.5 MPa ultimate tensile strength. When matrix viscosity falls outside the desired range, both ultimate tensile strength and strain capacity were diminished. By tailoring the VMA dosage, the matrix viscosity can be adjusted for desired fiber dispersion, workability, and mechanical properties. Finally, the findings of this study provide a technical reference for the practical design and application of PP-ECC.

36 MATERIALS SCIENCE↗

Prediction of radiation doses during the dismantling of the pressurized tank from emergency core cooling system of RBMK- 1500 reactor

Preparation for the decommissioning of the Ignalina Nuclear Power Plant involves multiple problems. Personnel radiation safety during the performance of dismantling activities is one of them. In order to assess the optimal personnel radiation safety, the modelling is performed for large components by the means of computer code 'VISIPLAN 3D ALARA Planning tool' developed by SCK CEN (Belgium). Modelling results of radiation doses during the dismantling of the pressurized tank from the emergency core cooling system (ECCS PT) of RBMK-1500 reactor are presented in this paper. The mass of one ECCS PT is approximately 47.6 tons. The radiological surveys indicate that the inner surface of the ECCS PT is contaminated with radioactive products of corrosion and sediments due to the radioactive water. The assessment of workers exposure was performed to comply with ALARA. The effective doses to the workers were modeled for different strategies of ECCS PT dismantling. The impact of dismantling tools and shielding types and extract ventilation flow rate during the dismantling of ECCS PT on effective doses were analyzed. The total effective personnel doses were obtained by summarizing the effective personnel doses from various sources of exposure, i. e., direct radiation from radioactive equipment, internal radiation due to inhalation of radioactive aerosols, and direct radiation from radioactive aerosols arising during hot cutting in premises. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

TESTING OF ENHANCED CHEMICAL CLEANING OF SRS ACTUAL WASTE TANK 5F AND TANK 12H SLUDGES

Forty three of the High Level Waste (HLW) tanks at the Savannah River Site (SRS) have internal structures that hinder removal of the last approximately five thousand gallons of waste sludge solely by mechanical means. Chemical cleaning can be utilized to dissolve the sludge heel with oxalic acid (OA) and pump the material to a separate waste tank in preparation for final disposition. This dissolved sludge material is pH adjusted downstream of the dissolution process, precipitating the sludge components along with sodium oxalate solids. The large quantities of sodium oxalate and other metal oxalates formed impact downstream processes by requiring additional washing during sludge batch preparation and increase the amount of material that must be processed in the tank farm evaporator systems and the Saltstone Processing Facility. Enhanced Chemical Cleaning (ECC) was identified as a potential method for greatly reducing the impact of oxalate additions to the SRS Tank Farms without adding additional components to the waste that would extend processing or increase waste form volumes. In support of Savannah River Site (SRS) tank closure efforts, the Savannah River National Laboratory (SRNL) conducted Real Waste Testing (RWT) to evaluate an alternative to the baseline 8 wt. % OA chemical cleaning technology for tank sludge heel removal. The baseline OA technology results in the addition of significant volumes of oxalate salts to the SRS tank farm and there is insufficient space to accommodate the neutralized streams resulting from the treatment of the multiple remaining waste tanks requiring closure. ECC is a promising alternative to bulk OA cleaning, which utilizes a more dilute OA (nominally 2 wt. % at a pH of around 2) and an oxalate destruction technology. The technology is being adapted by AREVA from their decontamination technology for Nuclear Power Plant secondary side scale removal. This report contains results from the SRNL small scale testing of the ECC process using SRS sludge tank sample material. A Task Technical and Quality Assurance Plan (TTQAP) details the experimental plan as outlined by the Technical Task Request (TTR). The TTR identifies that the data produced by this testing and results included in this report will support the technical baseline with portions having a safety class functional classification. The primary goals for SRNL RWT are as follows: (1) to confirm ECC performance with real tank sludge samples, (2) to determine the impact of ECC on fate of actinides and the other sludge metals, and (3) to determine changes, if any, in solids flow and settling behavior.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Remediation Guidance for Major Airports after a Bioterrorist Attack

This document provides general guidelines for airport managers, local officials, and other stakeholders for developing a response and recovery plan for a major airport following the release of a biological warfare agent, with specific guidance for remediation. San Francisco International Airport was selected as the example airport during development of the guidance to illustrate specific details. The spore-forming bacterium Bacillus anthracis was selected as the biological agent of primary concern because it is the most difficult of known bioterrorism agents to inactivate and is considered to be one of the agents most likely to be used as a biological weapon. The focus of the guidance is on cleanup and disposal activities associated with the Characterization, Decontamination, and Clearance Phases that are defined herein. Activities associated with the Notification and First-Response Phases are brieÀy discussed in Appendixes A and B, respectively. In addition to the main text of this Remediation Guidance document and associated appendixes, a data supplement was developed specifically for San Francisco International Airport. Requests for the data supplement must be made directly to the Emergency Planning Operations Division of San Francisco International Airport. This document does not describe public health responses to release of a biological warfare agent. If laboratory analytical results confirm the presence of a biological agent, the responsible public health agency involved in the response will commence appropriate public health actions, such as treatment (CDC 2004) and decontamination of potentially contaminated individuals, distribution of prophylaxis, and medical examinations. See the Centers for Disease Control and Prevention web site for more information on emergency public health responses (http://www.bt.cdc.gov/). Effective communication with the media and the public is an essential component of airport remediation and recovery. Whereas such communication is beyond the scope of this document, many helpful resources are available. (See Section 1.1 for more information.) The concept of operations described in this document for cleanup of a Bacillus anthracis release at a major airport conforms to the National Response Framework (NRF) (DHS 2008) and implementation of the National Incident Management System (NIMS 2004). In most cases, a Unified Command would be formed to direct the cleanup process jointly and to take ultimate responsibility for all cleanup decisions. The Unified Command would likely include the Airport Manager or Airport Emergency Operations Manager, representatives from state and local public health and emergency management agencies, and Federal agencies, such as the U.S. Environmental Protection Agency. The Unified Command and Incident Command Staff would ideally be co-located in an Incident Command Post in an uncontaminated area of the airport. If a release is large or complex, co-location of all key players may not be possible. If a major incident is declared, a Principal Federal Official may be appointed by the Department of Homeland Security to facilitate Federal support to the Unified Command. In some facilities and jurisdictions, additional response plans or procedures (such as BioWatch or other emergency response plans, procedures, or protocols) may govern notification and first response. Facility personnel, responders, and emergency management coordinators should be aware of all applicable plans and procedures and how to implement them. Cleanups following the anthrax attacks of 2001 in the U.S. pre-dated the NRF and NIMS and did not make use of a NIMS Incident Command System as we know it today. Most Incident Commanders for the larger of those cleanups chose to convene a Technical Working Group (TWG) of multi-agency, multi-disciplinary, outside experts to advise in developing sampling and decontamination plans. Most of the Incident Commanders also convened a separate Environmental Clearance Committee (ECC) to independently review pre- and post decontamination sampling data as well as data on decontamination parameters, to evaluate whether the decontamination was effective, and to add credibility regarding a decision that decontaminated areas may be reoccupied. Use of such specialized technical expertise is strongly recommended, although it would now operate within the construct of the NIMS Incident Command System. The TWG, if convened, would act in an advisory capacity to the Environmental Unit within the Planning Section. Likewise, the ECC, if convened, would provide independent peer review of products and recommendations by the Environmental Unit. For maximum impartiality, the ECC could also provide recommendations directly to the Unified Command. Cleanup activities commence with site characterization. The principal goal of characterization is to define the extent of contamination and to gather information needed to design the decontamination approach. Initial sampling data collected by first responders are assessed to approximate the location(s) of contamination. Confirmation of the agent type and viability is obtained from a Laboratory Response Network laboratory. Additional characterization data are collected to determine the extent of contamination and where decontamination actions are needed. Areas suspected of being contaminated are contained and isolated to the degree possible to prevent further movement of an agent to uncontaminated areas or the environment, and to reduce the potential for future exposure from the agent or fumigant, if fumigation is needed. Agent air monitoring in areas adjacent to the contained contamination zones is done to ensure the protection of remediation personnel and to monitor any release from the contained zones. Various sampling approaches are considered. For example, wipe samples can be used to sample hard, nonporous surfaces. Swab samples can be used to sample nooks, crannies, joints, and seams. Appendix I is a template for preparing an incident-specific, operational characterization plan. Upon completion of the characterization plan, an internal review is initiated. Upon approval of the plan by the Unified Command, characterization commences. The Site Safety Officer develops a Health and Safety Plan to ensure that coordinated health and safety measures are in place for all responding personnel. This plan describes physical, chemical, and biological hazards at the site, personal protective equipment, personal decontamination procedures, and emergency procedures to be used by sampling and remediation personnel. An incident-specific Remediation Action Plan is developed, which describes the decontamination methods to be used and other details, including waste disposal. Under NIMS, this overall plan, as well as other plans described below, are implemented through a series of standardized, shorter-term Incident Action Plans, which describe specific activities that will take place during a shift or a day. The template in Appendix J is designed to facilitate preparation of the Remediation Action Plan. If fumigation will be done, a Sampling and Analysis Plan will be needed, as well as an Ambient Air Monitoring Plan, which can be a component of the Remediation Action Plan. These three plans are needed to obtain a crisis exemption from the U.S. Environmental Protection Agency for authorized use of an unregistered sterilant or pesticide during cleanup. If pesticide products become registered for inactivation of B. anthracis in the future, the three plans will likely be required by the product’s labeling, but the plans would no longer be submitted to the U.S. Environmental Protection Agency for approval; rather, the Incident Commander would approve them. If fumigation is used, an Emergency Response Plan is also recommended, although such a plan is not required for a crisis exemption. For some nonpersistent biological warfare agents, natural attenuation may be an adequate decontamination option. In cases where contamination is not extensive or an agent is not persistent, application of surface decontaminants or other methods of medical infection control may be effective. For extensive contamination by persistent agents, such as Bacillus anthracis, fumigation may be necessary. In those cases, the Decontamination Phase commences with source reduction, such as pre-cleaning surfaces to reduce the contaminant load. To expedite cleanup and prevent costs from escalating unnecessarily, a cost–benefit analysis should be incorporated in the decision process related to retention versus disposal of facility items and materials. Certain materials and structural components can be decontaminated for reuse, but it may not be feasible or cost-effective to decontaminate other items. Those items must be pre-treated, packaged (with the package decontaminated externally), and removed for disposal as waste. Site preparation includes sealing openings to prevent leaks and setting up equipment. Decontamination reagents and delivery systems are selected, and pre-testing all systems is done before carrying out chemical treatment(s). The important choice of decontamination technologies depends on characteristics of the agent, the nature and extent of contamination, and other site parameters identified during characterization. Decontamination-related decisions can have a major impact on waste-disposal costs, and it is necessary to develop a disposal plan that identifies a means of disposal, necessary approvals, transportation, and other details. A clearance strategy is developed to ensure that after decontamination, the risk of exposure to residual contamination is negligible. A clearance sampling plan is developed, which sets clearance criteria, specifies how to determine whether the criteria have been met, and describes how and where to collect clearance samples after decontamination. In most cases, clearance sampling includes both surface and aggressive air samples. Appendix K is a clearance plan template that identifies the types of required information. To determine whether the decontaminated area may be reoccupied, the Environmental Unit (and the ECC separately, if one is convened) evaluates the results of clearance samples. For the anthrax incidents to date, and given methods that have been used, cleanup was considered successful only when there was no growth of B. anthracis cultured from any environmental samples taken after decontamination. Other factors that will be considered include the decontamination process parameters (e.g., temperature, relative humidity, decontaminant concentration, and contact time) and the results from post-decontamination culture of biological indicators that may have been used during fumigation or sterilization processes. From such an evaluation the Environmental Unit or ECC, or both, recommend whether the area may be reoccupied, or whether further decontamination is necessary. The UC makes the final decision that a facility is appropriately decontaminated for reoccupancy. The facility owner or responsible public health agency makes the final decision to reopen a decontaminated facility. A theme that is emphasized throughout this document is that many activities can greatly reduce the time required to restore airport operations if those activities are conducted prior to an actual release of biological warfare agent. A summary of specific resources (such as Federal, state, and local agency contacts; contractors; prospective team members; subject-matter experts; laboratory facilities; and other entities) that should be identified in advance by airport officials is provided in each pertinent section of this document, and summary contact lists of such resources are provided in Appendix L. A summary of overall pre-planning actions that should be completed by airport officials is presented at the end of this document.

59 BASIC BIOLOGICAL SCIENCES↗

THE EFFECT OF THE PRESENCE OF OZONE ON THE LOWER FLAMMABILITY LIMIT OF HYDROGEN IN VESSELS CONTAINING SAVANNAH RIVER SITE HIGH LEVEL WASTE

The Enhanced Chemical Cleaning (ECC) process uses ozone to effect the oxidation of metal oxalates produced during the dissolution of sludge in the Savannah River Site (SRS) waste tanks. The ozone reacts with the metal oxalates to form metal oxide and hydroxide precipitants, and the CO{sub 2}, O{sub 2}, H{sub 2}O and any unreacted O{sub 3} gases are discharged into the vapor space. In addition to the non-radioactive metals in the waste, however, the SRS radioactive waste also contains a variety of radionuclides, hence, hydrogen gas is also present in the vapor space of the ECC system. Because hydrogen is flammable, the impact of this resultant gas stream on the Lower Flammability Limit (LFL) of hydrogen must be understood for all possible operating scenarios of both normal and off-normal situations, with particular emphasis at the elevated temperatures and pressures of the typical ECC operating conditions. Oxygen is a known accelerant in combustion reactions, but while there are data associated with the behavior of hydrogen/oxygen environments, recent, relevant studies addressing the effect of ozone on the flammability limit of hydrogen proved scarce. Further, discussions with industry experts verified the absence of data in this area and indicated that laboratory testing, specific to defined operating parameters, was needed to comprehensively address the issue. Testing was thus designed and commissioned to provide the data necessary to support safety related considerations for the ECC process. A test matrix was developed to envelope the bounding conditions considered credible during ECC processing. Each test consists of combining a gas stream of high purity hydrogen with a gas stream comprised of a specified mixture of ozone and oxygen in a temperature and pressure regulated chamber such that the relative compositions of the two streams are controlled. The gases are then stirred to obtain a homogeneous mixture and ignition attempted by applying 10J of energy to a fuse wire. A gas combination is considered flammable when a pressure rise of 7% of the initial absolute pressure is observed. The specified testing methodology is consistent with guidelines established in ASTM E-918-83 (2005) 'Standard Practices for Determining Limits of Flammability of Chemicals at Elevated Temperature and Pressure'.

08 HYDROGEN↗

Emergency core cooling system performance criteria for Multi-Layered Silicon Carbide nuclear fuel cladding

Multi-layered Silicon Carbide (SiC) cladding has been proposed to replace the current Zircaloy (Zr) cladding in existing nuclear power plants. Due to its ceramic property, SiC may have a different failure mechanism from that of metallic Zr clad. This characteristic should be considered in designing the plant’s safety system performance, such that the fuel’s integrity is reasonably assured during accident scenarios. This paper aims at optimizing the Emergency Core Cooling System (ECCS) performance criteria in mitigating LBLOCA accidents at a Pressurized Water Reactor (PWR) using the uranium dioxide fuel and duplex or triplex SiC cladding structures. Clad failures by brittle fractures and thermal degradation were modeled in a fuel analysis code. This fuel model was coupled with the RELAP5 plant model by adapting the fuel’s mesh configuration and formulating the effective heat transfer coefficients. A model to quantify the likelihood of clad functional failure as a combination of individual layer fractures at various axial positions was proposed. Updated SiC material properties were gathered from recent reference studies. Clad reliability estimates using the proposed model were compared with the estimates obtained using other models. The results were used to relax the criterion of required actuation timing of ECCS, such that the risk of the new plant design is less or equal to that of the initial plant configuration. Triplex clad was more reliable than duplex clad and Zr, reducing the conditional core damage probability by three orders of magnitude in the reference LBLOCA scenario. Compressive stresses due to irradiation swelling played the determining role in the vulnerabilities of each clad design. The duplex clad was vulnerable to pressure-loading stresses while triplex clad was prone to fail due to thermal shocks experienced during the LOCA reflood phase. Additionally, it was concluded that the most vulnerable axial fuel rod location in the reference LBLOCA scenario was located at the highest axial power peaking location. A sensitivity study on the ECCS timing density was conducted. The results showed that ECCS actuation timing could be extended from the initial technical specification, without increasing the fuel damage likelihood. The time extension was distributed in the order of several hundreds of seconds, which was comparable with time extensions offered by FeCrAl and Cr-coated-Zr clad designs in LBLOCA scenarios. This time extension may potentially reduce the failure probabilities of EDGs and pumps, hence improving the plant safety further.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗