Search NASA⌕ Search

SEARCH · Search NASA

Results for “EIS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Determining Proton Transport in Pseudo Catalyst Layers Using Hydrogen Pump DC and AC Techniques

Optimizing electrode morphology with a more uniform ionomer distribution is key to reducing ohmic losses and increasing electrocatalyst utilization in polymer electrolyte fuel cells (PEFCs). Inherent ionomer conductivity, volume fraction and tortuosity determine effective ionic conductivity. We use hydrogen pump (HP) method to measure effective ionic conductivity of a pseudo catalyst layer (PCL) comprised of Vulcan XC-72 carbon black and 3M 825 EW ionomer with ionomer to carbon (I/C) ratios of 0.6, 1 and 1.4 and relative humidity (RH) range of 50 to 120%. These direct current (DC) experiments are then compared with electrochemical impedance spectroscopy (EIS). Both DC and EIS methods show good agreement, indicating that EIS can be used as an alternative to DC method in HP experiment. Ionic conductivity for PCL with I/C of 1 and 1.4 was found to be about one order of magnitude higher than I/C of 0.6 for most of the RH range. At 90% RH tortuosities for I/C = 1 and 1.4 were close to 1, whereas tortuosity for I/C = 0.6 was 3. With decrease in relative humidity tortuosities increased linearly and at 50% relative humidity a PCL with I/C = 0.6 had the highest tortuosity of 6.1.

25 ENERGY STORAGE↗

Interpreting Ionic Conductivity for Polymer Electrolyte Fuel Cell Catalyst Layers with Electrochemical Impedance Spectroscopy and Transmission Line Modeling

A cathode catalyst layer containing optimally distributed ionomer is critical to reduce the platinum loading and increase its utilization in polymer electrolyte fuel cells. Here, electrochemical impedance spectroscopy (EIS) was used to measure effective ionic conductivity of pseudo catalyst layers (PCLs) at a relative humidity (RH) range of 50%-120%. These results are compared to previous work using the hydrogen pump (HP) method. EIS effective ionic conductivity results reported here are higher than those from the HP because in the HP set-up ionic pathways must be effectively connected through the PCL to be counted, whereas in the EIS measurement, ionomer segments that are in contact with the membrane but are not effectively connected all the way through the PCL can be detected. Double layer capacitances and effective ionic conductivities of Pt/C catalyst layers with various supports and ionomer to carbon (I/C) ratios were studied. High surface area carbon support resulted in a lower effective ionic conductivity compared to the graphitized carbon support due to worse ionomer dispersion. Effective ionic conductivities of Pt/C layers were compared to that of PCLs. On average, effective ionic conductivities of Pt/C layers were higher than PCLs because of possible carbon agglomeratio n within the PCLs.

25 ENERGY STORAGE↗

Machine Learning Benchmarks for the Classification of Equivalent Circuit Models from Electrochemical Impedance Spectra

Analysis of Electrochemical Impedance Spectroscopy (EIS) data for electrochemical systems often consists of defining an Equivalent Circuit Model (ECM) using expert knowledge and then optimizing the model parameters to deconvolute various resistance, capacitive, inductive, or diffusion responses. For small data sets, this procedure can be conducted manually; however, it is not feasible to manually define a proper ECM for extensive data sets with a wide range of EIS responses. Automatic identification of an ECM would substantially accelerate the analysis of large sets of EIS data. We showcase machine learning methods to classify the ECMs of 9,300 impedance spectra provided by QuantumScape for the BatteryDEV hackathon. The best-performing approach is a gradient-boosted tree model utilizing a library to automatically generate features, followed by a random forest model using the raw spectral data. A convolutional neural network using boolean images of Nyquist representations is presented as an alternative, although it achieves a lower accuracy. We publish the data and open source the associated code. The approaches described in this article can serve as benchmarks for further studies. A key remaining challenge is the identifiability of the labels, underlined by the model performances and the comparison of misclassified spectra.

25 ENERGY STORAGE↗

Early Detection of Li-Ion Battery Thermal Runaway Using Commercial Diagnostic Technologies

The rate of electric vehicle (EV) adoption, powered by the Li-ion battery, has grown exponentially; largely driven by technological advancements, consumer demand, and global initiatives to reduce carbon emissions. As a result, it is imperative to understand the state of stability (SoS) of the cells inside an EV battery pack. That understanding will enable the warning of or prevention against catastrophic failures that can lead to serious injury or even, loss of life. The present work explores rapid electrochemical impedance spectroscopy (EIS) coupled with gas sensing technology as diagnostics to monitor cells and packs for failure markers. These failure markers can then be used for onboard assessment of SoS. Experimental results explore key changes in single cells and packs undergoing thermal or electrical abuse. Rapid EIS showed longer warning times, followed by VOC sensors, and then H 2 sensors. While rapid EIS gives the longest warning time, with the failure marker often appearing before the cell vents, the reliability of identifying impedance changes in single cells within a pack decreases as the pack complexity increases. This provides empirical evidence to support the significant role that cell packaging and battery engineering intricacies play in monitoring the SoS.

25 ENERGY STORAGE↗

Criterion validity of wrist accelerometry for assessing energy intake via the intake-balance technique

Background: Intake-balance assessments measure energy intake (EI) by summing energy expenditure (EE) with concurrent change in energy storage (ΔES). Prior work has not examined the validity of such calculations when EE is estimated via open-source techniques for research-grade accelerometry devices. The purpose of this study was to test the criterion validity of accelerometry-based intake-balance methods for a wrist-worn ActiGraph device. Methods: Healthy adults (n = 24) completed two 14-day measurement periods while wearing an ActiGraph accelerometer on the non-dominant wrist. During each period, criterion values of EI were determined based on ΔES measured by dual X-ray absorptiometry and EE measured by doubly labeled water. A total of 11 prediction methods were tested, 8 derived from the accelerometer and 3 from non-accelerometry methods (e.g., diet recall; included for comparison). Group-level validity was assessed through mean bias, while individual-level validity was assessed through mean absolute error, mean absolute percentage error, and Bland–Altman analysis. Results: Mean bias for the three best accelerometry-based methods ranged from -167 to 124 kcal/day, versus -104 to 134 kcal/day for the non-accelerometry-based methods. The same three accelerometry-based methods had mean absolute error of 323–362 kcal/day and mean absolute percentage error of 18.1-19.3%, versus 353–464 kcal/day and 19.5-24.4% for the non-accelerometry-based methods. All 11 methods demonstrated systematic bias in the Bland–Altman analysis. Conclusions: Accelerometry-based intake-balance methods have promise for advancing EI assessment, but ongoing refinement is necessary. We provide an R package to facilitate implementation and refinement of accelerometry-based methods in future research (see paulhibbing.com/IntakeBalance).

60 APPLIED LIFE SCIENCES↗

Proximal Observations of Epicentral Infrasound Generated by Shallow Low-Magnitude Earthquakes in the Permian Basin, West Texas

Infrasound generated by earthquakes and explosions is generally detected at receivers at epicentral distances of hundreds to thousands of kilometers. However, proximal (<50 km) observations are especially important for low-magnitude earthquakes and low-yield explosions that may not generate signals capable of being detected at great ranges. Here, in this study, we present on the signals detected on an infrasound array 3 km away from two M L 2.9 earthquakes in the Permian Basin of west Texas. Local infrasound (LIS), generated at receivers during the passage of seismic waves, was detected following each earthquake. Epicentral infrasound (EIS), created at or near the epicenter and propagating away as a sound wave, was also detected. Array processing methods show that the EIS signals arrive from the same direction as the earthquake epicenters and at acoustic speeds. To our knowledge, these are the first observations of laterally propagating EIS at proximal ranges following an earthquake of any magnitude.

58 GEOSCIENCES↗

Performance Assessment of Photovoltaic Panels Using Impedance Spectroscopy

The goal of this project was to develop a technique for measuring internal characteristics of a PV module using light modulation under a fixed voltage bias while measuring the resulting alternating current. This technique, light-intensity modulated impedance spectroscopy (LIMIS), has the promise of detecting early signs of panel aging and degradation that could be used for example by solar farm operators to have early warnings to repair or replace panels to maintain reliability of the overall PV array. LIMIS would be complementary with the previously developed electrochemical impedance spectroscopy (EIS), which uses an alternating voltage applied electrically to a solar cell with a similar alternating current measurement. EIS has mostly been developed for individual PV cells rather than whole modules. The project was intended to assess what different information could be revealed by LIMIS, which may in some cases be more scalable to larger modules and potentially more practical to apply in field measurements without needing to electrically disconnect PV modules. We began with small 10 W PV modules and built a testbed capable of oscillating the light intensity with frequencies up to 50 kHz. In parallel, we built a large testbed for testing large 250 W PV modules. Meanwhile, we developed procedures for established measurement techniques: current–voltage (I–V), EIS, and electroluminescence (EL) imaging, where panels are subjected to forward bias while their infrared emission is recorded using a camera modified to be sensitive to IR wavelengths. In addition, we developed protocols for accelerated aging of PV modules in two ways. Thermal cycling from –40°C to +90°C simulates the diurnal temperature cycles on a rooftop. Mechanical stress by dropping a 227 g ball from a height of 1 m simulates damage such as that due to hail impacts.

14 SOLAR ENERGY↗

A mathematical approach to survey electrochemical impedance spectroscopy for aging in lithium-ion batteries

Electrochemical impedance spectroscopy (EIS) is a valuable technique to detect the health status and aging phenomena in lithium-ion batteries (LiB). Equivalent circuit modeling (ECM) is conventionally used when interpreting EIS data and gaining physical insights into the aging mechanisms. However, performing ECM is resource intensive and expert-level of knowledge is usually required to select suitable models and fitting parameters. This article presents a quick and user-friendly data analysis algorithm as an alternative to ECM by mathematically fitting geometric features in Nyquist plots and obtaining the growth trends of the features. The evolving trends in the Nyquist plots, such as chord lengths of the arcs and interception points, are consistent with the growth of resistance components obtained using ECM with R 2 values from 0.67 to 0.99, and therefore can be used as indicators of battery aging. Our results show that the quick-fitting approach is suitable for analyzing a series of EIS data acquired during battery cycling and identifying the underlying aging mechanisms.

Chen, Bor-Rong↗

Building Analytics Tool Deployment at Scale: Benefits, Costs, and Deployment Practices

Buildings are becoming more data-rich. Building analytics tools, including energy information systems (EIS) and fault detection and diagnostic (FDD) tools, have emerged to enable building operators to translate large amounts of time-series data into actionable findings to achieve energy and non-energy benefits. To expedite data analytics adoption and facilitate technology innovation, building owners, technology developers, and researchers need reliable cost–benefit data and evidence-based guidance on deployment practices. This paper fulfills these needs with the energy use and survey data from a wide-ranging research and industry partnership program that covers thousands of buildings installed with analytics tools. The paper indicates that after two years of implementation, organizations using FDD tools and EIS tools achieved 9% and 3% median annual energy savings, respectively. The median base cost and annual recurring cost for FDD are USD 0.65 per square meter (m2) (USD 0.06 per square foot [ft2]) and USD 0.22 per m2 (USD 0.02 per ft2), and are USD 0.11 per m2 (USD 0.01 per ft2) and USD 0.11 per m2 (USD 0.01 per ft2) for EIS. The common metrics and analyses that are used in the tools to support the discovery of energy efficiency measures are summarized in detail. Two best practice examples identified to maximize the benefits of tool implementation are also presented. Opportunities to advance the state of technology include simplified data integration and management, and more efficient processes for acting on analytics outputs. Compared with previous efforts in the literature, the findings presented in this paper demonstrate the effectiveness of building analytics tools with the largest known dataset.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Electrochemical Impedance Spectroscopy and Cyclic Voltammetry Methods for Monitoring SmCl 3 Concentration in Molten Eutectic LiCl-KCl

Molten salt solutions consisting of eutectic LiCl-KCl and concentrations of samarium chloride (0.5 to 3.0 wt%) at 500 C were analyzed using both cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The CV technique gave the average diffusion coefficient for Sm 3+ over the concentration range. Equipped with Sm 3+ diffusion coefficient, the Randles-Sevcik equation predicted Sm 3+ concentration values that agree with the given experimental values. From CV measurements; the anodic, cathodic, and half-peak potentials were identified and subsequently used as a parameter to acquire EIS spectra. A six-element Voigt model was used to model the EIS data in terms of resistance-time constant pairs. The lowest resistances were observed at the half-peak potential with the associated resistance-time constant pairs characterizing the reversible reaction between Sm 3+ and Sm 2+ . By extrapolation, the Voigt model estimated the polarization resistance and established a polarization resistance-concentration relationship.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Estimation of Electromechanical Modes of Oscillation in the Eastern Interconnection from Ambient PMU Data

A power system's inter-area electromechanical modes of oscillation determine if the system is small-signal stable. Mode meters are tools that estimate the modes based on ambient synchrophasor measurements, allowing continuous monitoring of the system's stability margin. This paper reports on the application of mode meter algorithms to 21 months of synchrophasor measurements from the United States Eastern Interconnection (EI). Estimates for three modes were updated every minute, providing a much more comprehensive set of results than previous studies based on disturbance recordings. The detailed signal designs and mode meter configurations provided in this paper can be used to accelerate mode meter deployments in the EI. Analysis of the mode estimates reveal for the first time how seasonal load changes and system reconfiguration impact the EI system's dynamics.

Follum, James D.↗

Draft Environmental Impact Statement for Proposed Energy Conservation Standards for Manufactured Housing

This draft environmental impact statement (EIS) analyzes the impacts related to DOE’s proposed energy conservation standards for manufactured homes. DOE’s proposed energy conservation standards are based on the 2021 International Energy Conservation Code (IECC) and relate to the building thermal envelope; air sealing; installation of insulation; duct sealing; heating, ventilation and air conditioning (HVAC); service hot water systems; mechanical ventilation fan efficacy; and heating and cooling equipment sizing. The draft EIS evaluates DOE’s proposed action (energy conservation standards tiered based the manufacturers retail list price), alternatives to the proposed action (including energy conservation standards tiered based on size of the manufactured home and untiered standards), and a no action alternative. The draft EIS presents analysis of impacts related to (1) energy resources; (2) air resources (including greenhouse gases, climate change, ambient air quality and indoor air quality); (3) health and safety; (4) socioeconomics; and (5) environmental justice.

MacDonell, Margaret↗

Online Tracking of Two Dominant Inter-Area Modes of Oscillation in the Eastern Interconnection

Reliable power system operation requires that small-signal stability be maintained at all times. Mode meters are measurement-based tools that provide operators with situational awareness of the system's stability margin. They operate by continually tracking the inter-area modes of oscillation that govern small-signal stability. This paper reports on the deployment of mode meters for online monitoring of two dominant modes of oscillation in the United States' Eastern Interconnection (EI). The use of measurements from system operators across the interconnection to provide continuous tracking is novel in the EI. Results from over four months of analysis reveal diurnal patterns in the modes and demonstrate that they can be tracked through a variety of system conditions. The results from this study continue to build an understanding of the EI's modes that will inform future modeling and monitoring efforts.

Follum, James D.↗

Kinetic study of hydrogen transport in graphite under molten fluoride salt environment

Here, in this work, a kinetic model, which describes the reactions occurring during the hydrogen charging process on a graphite surface, was optimized on Electrochemical Impedance Spectroscopic (EIS) to study the entry of hydrogen into graphite in high temperature molten FLiNaK salt. The results show that the rate constants of k 1 increases with decreasing applied potential (becoming more negative), and k 2 and k 3 are independent of the applied potential. At the same charging potential, all the three rate constants are independent of the water concentration in the FLiNaK salt. The surface coverage of absorbed hydrogen increases with decreasing the charging potential and increasing the moisture content in the salt. The adsorption efficiency of hydrogen increases with increasingly charging potential and decreases with increasing moisture content of the FLiNaK salt. These results demonstrate that EIS is a promising technique for measuring the kinetic parameters for hydrogen transport in graphite under molten fluoride salt environment.

EIS↗

Exploring the Impacts of Conditioning on Proton Exchange Membrane Electrolyzers by In Situ Visualization and Electrochemistry Characterization

For a proton exchange membrane electrolyzer cell (PEMEC), conditioning is an essential process to enhance its performance, reproducibility, and economic efficiency. To get more insights into conditioning, a PEMEC with Ir-coated gas diffusion electrode (IrGDE) was investigated by electrochemistry and in situ visualization characterization techniques. The changes of polarization curves, electrochemical impedance spectra (EIS), and bubble dynamics before and after conditioning are analyzed. The polarization curves show that the cell efficiency increased by 9.15% at 0.4 A/cm 2 , and the EIS and Tafel slope results indicate that both the ohmic and activation overpotential losses decrease after conditioning. The visualization of bubble formation unveils that the number of bubble sites increased greatly from 14 to 29 per pore after conditioning, at the same voltage of 1.6 V. Under the same current density of 0.2 A/cm 2 ; the average bubble detachment size decreased obviously from 35 to 25 µm. Furthermore, the electrochemistry and visualization characterization results jointly unveiled the increase of reaction sites and the surface oxidation on the IrGDE during conditioning, which provides more insights into the conditioning and benefits for the future GDE design and optimization.

08 HYDROGEN↗

Morphological Degradation of Oxygen Evolution Reaction-Electrocatalyzing Nickel Selenides at Industrially Relevant Current Densities

We investigated electrodeposited nanoparticulate nickel selenide (pre)catalysts that transform into nickel oxides/ oxyhydroxides under oxygen evolution reaction conditions in alkaline solutions. Previous studies of this transformation were conducted at lower current densities than those of industrial relevance (≥1 A cm −2 ). We used ultramicroelectrodes (UMEs) to achieve such current densities, benefiting from their small size, ensuring low absolute currents and low ohmic drop but high current densities. Morphological degradation of the catalyst material was only observed at current densities exceeding 1 A cm −2 but not for smaller ones. Using X-ray absorption, Xray photoemission spectroscopy, and X-ray diffraction, we confirmed that the degradation was accompanied by the literature-known transformation of nanoparticulate Ni 3 Se 2 (bulk)/NiSe (surface) into nickel oxyhydroxide. The transformation of the precatalyst goes along with a significant improvement in the charge transfer kinetics observed by decreasing Tafel slopes with ongoing experimental time extracted from cyclic voltammetry (CV) experiments and electrochemical impedance spectroscopy (EIS) in the high-frequency range. However, these kinetic improvements are accompanied by limitations in mass transport concluded from decreasing current responses at high overpotentials in CVs and increasing impedance in the low-frequency range of the EIS spectra after extended CV cycling. These mass transport limitations originated from morphological degradations at the UME exceeding 1 A cm −2 which we proved by applying identical location scanning electron microscopy. This has not been reported in studies that have been limited to lower current densities before. Our findings showcase how UMEs can be used to study (pre)catalysts (herein nickel selenides) under current densities of industrial relevance in the absence of ohmic drop-related ambiguities, combined with in-depth materials characterization studies, e.g., identical location microscopy and advanced spectroscopic methods. This approach enables direct evaluation and comparison of catalyst materials and thus demonstrates how to overcome long-standing limitations of electrocatalyst design and testing.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electron emission from bromouracil and uracil induced by protons and radiosensitization

Absolute double differential cross sections (DDCS) of electrons emitted from uracil and 5-bromouracil (BrU) in collisions with protons of energy 200 keV have been measured for various forward and backward emission angles over wide range of electron energies. The measured DDCS are compared with the continuum distorted wave-eikonal initial state (CDW-EIS) calculations. The optimized structure of the BrU was estimated along with the population analysis of all the occupied orbitals using a self-consistent field density. A comparison between the measured DDCS data for the two molecules show that the cross section of low energy electrons emitted from BrU is substantially larger than that for uracil. The BrU-to-uracil DDCS ratios obtained from the present measurements indicate an enhancement of the electron emission by a factor which is as large as 2.0 to 2.5. These electrons being the major agent for damaging the DNA/RNA of the malignant tissues, the present results are expected to provide an important input for the radiosensitization effect in hadron therapy. It is noteworthy to mention that the CDW-EIS calculations for Coulomb ionization cannot predict such enhancement. A large angular asymmetry is observed for uracil with a broad structure, which is absent in case of BrU.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

On Stability and Electrochemical Performance of 316 Stainless Steel in Wastewater: Implications for Resource Recovery

Electrochemical nutrient recovery systems rely on stable electrode materials capable of operating in chemically complex wastewater environments. We investigated corrosion resistance and interfacial electrochemical behavior of 316 stainless steel (SS316) in a synthetic wastewater matrix representative of centrate streams, a key knowledge gap in electrochemical phosphorus recovery. A comprehensive suite of electrochemical techniques (chronoamperometry, cyclic voltammetry, potentiodynamic polarization, and electrochemical impedance spectroscopy (EIS)) and surface characterization methods (scanning electron microscopy, X-ray diffraction) were employed. Results revealed that wastewater containing typical ionic constituents (such as PO 4 3- , NH 4 + , and divalent cations) exhibited enhanced cathodic activity and the formation of a more stable, protective surface film on SS316 that mitigated chloride-induced corrosion. In contrast, SS316 in the NaCl solution showed significant susceptibility to passive layer breakdown and localized corrosion. Time-resolved EIS further confirmed improved interfacial stability and restricted charge transfer in WW over time, in stark contrast to the progressive passive layer degradation in NaCl. Surface analyses corroborated these findings, showing limited surface attack in WW compared to distinct localized corrosion features in NaCl. These findings indicate that competing ionic species in WW effectively mitigate chloride aggressiveness, enhance SS316 stability, and demonstrate improved electrode longevity and reliability for sustainable wastewater-based electrochemical phosphorus recovery applications.

36 MATERIALS SCIENCE↗