Search NASA⌕ Search

SEARCH · Search NASA

Results for “ELECTRIC ENERGY STORAGE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

System and operation for thermochemical renewable energy storage

Systems and methods for energy storage and energy recovery are provided. An electrical-to-electrical energy storage system includes a thermochemical energy storage device, a blower, a compressor, a turbine, and an electrical generator. The TCES device includes a vessel, a porous bed, and a heater. The porous bed is disposed within an interior volume of the vessel. The porous bed comprises a reactive material. The reactive material is configured to release oxygen upon being heated to a reduction temperature, and generate heat when exposed to oxygen. The heater is in thermal contact with the reactive material. The blower is configured to remove oxygen from the interior volume. The compressor is configured to flow oxygen into the interior volume. The turbine is configured to receive a heated, oxygen-depleted gas from the interior volume. The generator is configured to be powered by the turbine to generate electricity.

Klausner, James F.↗

Thermochemical renewable energy storage

Systems and methods for energy storage and energy recovery are provided. An electrical-to-electrical energy storage system includes a thermochemical energy storage device, a blower, a compressor, a turbine, and an electrical generator. The TCES device includes a vessel, a porous bed, and a heater. The porous bed is disposed within an interior volume of the vessel. The porous bed comprises a reactive material. The reactive material is configured to release oxygen upon being heated to a reduction temperature, and generate heat when exposed to oxygen. The heater is in thermal contact with the reactive material. The blower is configured to remove oxygen from the interior volume. The compressor is configured to flow oxygen into the interior volume. The turbine is configured to receive a heated, oxygen-depleted gas from the interior volume. The generator is configured to be powered by the turbine to generate electricity.

Klausner, James F.↗

Value of Geothermal Energy Storage for Supply-Side and Demand-Side Applications

This report presents the results of a study examining the value potential for geothermal energy storage (GES), a long-duration energy storage resource that stores thermal and/or geomechanical energy in the subsurface. GES could benefit the overall U.S. power system by temporally shifting electricity generation (supply-side) or meeting building heating and cooling load (demand-side). This report analyzes supply-side and demand-side opportunities independently because of differences in applications and models. Currently there is significant uncertainty about the development costs for GES, with only a limited number of demonstration plants for electric energy storage and building heating and cooling storage developments. In this report, we estimate the value of supply-side and demand-side GES to the bulk power system in the contiguous United States. Because of the significant uncertainty about GES development costs, this analysis does not consider GES deployment costs but instead focuses on the value of GES to the U.S. electricity system. The estimated values of GES provide reference points for economically competitive commercial cost targets. Supply-side GES is modeled as part of an enhanced geothermal system (EGS) generation plant in NREL's Regional Energy Deployment System (ReEDS) capacity expansion model (Ho et al. 2021). In contrast to conventional geothermal plants, which generate constant power, EGS plants have unique features that may allow for in-reservoir energy storage for flexible generation. Demand-side GES for heating and cooling, including seasonal hot and cold storage and short-duration heat pump storage, is incorporated into a price-taker model using Cambium electricity marginal cost projections. To establish an upper bound for the value of GES, analysis focused on favorable scenarios for storage with high generation from zero marginal cost, variable renewable energy resources. High penetrations of variable renewable energy generation can increase hourly electricity price variability, which increases the value of temporal energy arbitrage for storage technologies like GES.

15 GEOTHERMAL ENERGY↗

Global Perspective of Energy Storage (2019 Annual Peer Review Report)

This report provides information about the DOE Office of Electricity Energy Storage Peer Review held in 2019 and includes posters reviewed in these categories: postdoctoral, validated reliability and safety performance, equitable regulatory environment and analytics, applied materials (Materials I), power electronics, industry acceptance, partnerships, and Materials I.

13 HYDRO ENERGY↗

The Impact of Behind-the-Meter Heterogeneous Distributed Energy Resources on Distribution Grids

The increasing integration of distributed energy resources (DERs) on the electric grid brings new challenges and opportunities for utility grid operations. With the rapid deployment of DERs, there is emerging interest in integrating these controllable devices with utility operations at all levels for monitoring and management. To understand the challenges with increasing behind-the-meter (BTM) DERs and to identify the needs in deploying advanced controls, a comprehensive grid impact study is indispensable. This paper presents the analysis which help visualize the DER impact on the grid, identify the challenges and provides an insight into the new distribution management and control needs to enable reliable and resilient grid operations.

behind-the-meter↗

Electric vehicle batteries alone could satisfy short-term grid storage demand by as early as 2030

The energy transition will require a rapid deployment of renewable energy (RE) and electric vehicles (EVs) where other transit modes are unavailable. EV batteries could complement RE generation by providing short-term grid services. However, estimating the market opportunity requires an understanding of many socio-technical parameters and constraints. We quantify the global EV battery capacity available for grid storage using an integrated model incorporating future EV battery deployment, battery degradation, and market participation. We include both in-use and end-of-vehicle-life use phases and find a technical capacity of 32–62 terawatt-hours by 2050. Low participation rates of 12%–43% are needed to provide short-term grid storage demand globally. Participation rates fall below 10% if half of EV batteries at end-of-vehicle-life are used as stationary storage. Short-term grid storage demand could be met as early as 2030 across most regions. Our estimates are generally conservative and offer a lower bound of future opportunities.

25 ENERGY STORAGE↗

Emerging Technologies Review: Pumped Storage Hydropower

The Air Force Civil Engineer Center (AFCEC) has tasked Pacific Northwest National Laboratory with investigating emerging technologies to inform the Air Force’s understanding of the technology and to guide key considerations for implementing technologies that are resilient and alternative sources to the traditional methods used in the Air Force today. This report explores pumped storage hydropower. Pumped storage hydropower (PSH) currently provides 93% of grid-scale storage capacity (MW) and 99% of electrical energy storage (MWh) in the United States. PSH exploits the potential energy that can be stored by pumping water to higher elevations or pressures to be dispatched when needed. In its simplest form, PSH uses energy to pump water to an upper reservoir for storage, then releases this water through a turbine and generator into a lower reservoir when needed for energy generation. This report provides a thorough technology description, technical considerations, siting considerations, economic/funding considerations associated with the technology. A Regulatory overview and risks associated with the technology are also included in the report.

13 HYDRO ENERGY↗

FY22 Grid Modernization & Energy Storage Program: Accomplishments & Impacts

Sandia’s Grid Modernization and Energy Storage program works to advance a national vision of a secure, resilient, and sustainable electric system for all users. Our achievements reflect a strategic approach combining technology development; modeling, simulation, and data analytics; and partnered demonstrations and outreach to further the adoption of advanced grid and storage technologies. Our FY22 efforts leverage the strengths of our partnerships—spanning Sandia’s core science and technology competencies as well as external technology leaders—to develop the solutions today which enable the grid of tomorrow. Much of the material in this report comes from the separate 2022 Accomplishments Report compiled by our Energy Storage subprogram team, a cornerstone of our grid research and achievements. The Grid Energy Storage Program at Sandia is focused on making energy storage cost-effective through research and development (R&D) in new battery technologies, advanced power electronics and power conversion systems, improved safety and reliability for energy storage systems, analytical tools for the valuation of energy storage, and the validation of new energy storage technologies through demonstration projects. During the 2022 fiscal year, Sandia executed R&D work supported by the U.S. Department of Energy’s (DOE) Office of Electricity – Energy Storage Program under the leadership of Dr. Imre Gyuk. This report indicates key areas of research and engagement and summarizes the impact of Sandia’s contributions through notable accomplishments, journal publications, patents, and technical conferences and presentations. It is provided with the hope that readers discover ways we can further team to create our modern grid and apply the outcomes of our efforts. The bulk of work described herein is funded by the DOE Office of Electricity and key programs within the DOE Office of Energy Efficiency and Renewable Energy. As we indicated in our report from last year, the contributors to our successes are too numerous to name here, though our team wishes to express our deep gratitude to the numerous program and project sponsors at the US Department of Energy, who often function equally as technical collaborators; our many partners in industry, academia, utilities, and other national labs; and fellow researchers and business partners at Sandia whose leadership and creativity have enabled the accomplishments described herein.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Electrochemical dynamics of imidazolium ionic liquids at graphene electrodes for energy storage applications

Electric double layer capacitors (EDLCs) are prominent energy storage systems that constitute the foundation of more reliable and sustainable energy infrastructures. Modern EDLCs often incorporate ionic liquids (ILs) as a key component in their electrolytes, leveraging the high electrochemical stability of ILs to enhance device performance. The performance and functionality of these capacitors also hinge on the interfacial behavior of ILs at electrode surfaces, which remain insufficiently understood. Here, we performed synchrotron infrared nanospectroscopy (SINS) in combination with density functional theory (DFT) calculations to investigate the electric double layers (EDLs) of three imidazolium-based ILs in a custom-designed graphene liquid cell. This approach revealed new insights into the dynamics of IL EDLs and the underpinning factors originating from the IL structures. Variations in anion size and structure were found to tune the ILs’ ability to form EDLs with compact and closely-correlated ion arrangements, which are critical for enhancing their capacitive performance. These findings highlight the intricate interactions between ions governed by their structures and charge behaviors, which underscores the opportunities for targeted design of IL-based electrolytes to optimize EDLC functionality.

Electric double layers↗

Isothermal Versus Sensible Cold Storage: A Model-Based Performance Comparison for Pumped Thermal Electricity Storage

Pumped-thermal energy storage (PTES) systems consume and produce electrical energy using thermal storage media as an intermediate stage. PTES lends itself to long-duration energy storage to facilitate high penetration of intermittent electricity generation. This study presents a model-based comparison of two thermal storage types within a PTES system: a conventional, single-phase, stratified water-glycol sensible storage system (SGS), and an ideal isothermal, two-phase heat exchanger that freezes a water reservoir (isothermal heat exchanger (IHEX)). The SGS thermal storage capacity is based on the liquid’s sensible heat change with temperature, whereas the capacity of the IHEX is based on the latent heat of isothermally freezing and melting water. The idealized IHEX modeled here undergoes steady-state melting and freezing (in contrast to transient rates, as observed with ice-on-coil storage). A computational model of a complete PTES system is presented and used to evaluate the PTES system-level performance with each type of cold storage. Compared to SGS-based PTES, under nominal operating conditions, the IHEX-based PTES increased electrical round-trip efficiency from 61% to 82% and increased energy density from 1.13 to 8.09 kWh/m 3 In conclusion, the performance of the PTES configured with IHEX storage was also analyzed under varying operating parameters.

25 ENERGY STORAGE↗

Advanced Compressors for CO2-Based Power Cycles and Energy

Pumped thermal energy storage (PTES) is a cost-effective method for grid-scale, long-duration electrical energy storage (LDES). PTES uses a heat pump cycle to transfer thermal energy from a low temperature reservoir (LTR) to a high temperature reservoir (HTR), later using a heat engine cycle to reverse the process. A key component of the PTES system, the heat pump compressor, represents a significant driver to the cost, performance and operating characteristics of the PTES system. For grid-scale charging (>100 MW), traditional compressor scaling charts indicate that the operating conditions needed would be best served by a multistage axial compressor. While frame gas turbine compressors at these power ratings exist and operate at higher pressure ratios than needed for the CO2 PTES system, the inlet pressure and fluid density of this application exceed experience values. A conceptual design of a large-scale CO2 axial compressor was completed, including mean-line estimates of the compressor performance at full power conditions. The results of the conceptual design were used to refine the PTES cycle design, and updated operating conditions provided for further aero design optimization. A roughly one third scale of the first three stages of the 100 MW compressor was designed, built, and tested at relevant PTES charging conditions. Results of this test program are compared against high-resolution computational fluid dynamics models.

Compressor Heat↗

Optimal Sizing of PV and Energy Storage in an Electric Vehicle Extreme Fast Charging Station

This paper proposes an optimization model for the optimal sizing of photovoltaic (PV) and energy storage in an electric vehicle extreme fast charging station considering the coordinated charging strategy of the electric vehicles. The proposed model minimizes the annualized cost of the extreme fast charging station, including investment and maintenance cost of PV and energy storage, cost of purchasing energy from utility and demand charge. The decision variables are capacity of invested PV and the power and energy ratings of invested energy storage. To further reduce the annualized cost of the extreme fast charging station, the charging strategy of electric vehicles are integrated into the optimization model and coordinated with the power output of PV and charging/discharging of energy storage. Results of numerical simulations indicate that investment of PV and energy storage could help reduce the annualized cost of the extreme fast charging station significantly. Meanwhile, the impacts of various parameters on the optimal solution are investigated by sensitivity analysis.

Liu, Guodong↗

High Rate Sodium Storage Mechanisms in Non-Graphitic Carbons

Lithium ion batteries (LIBs) have been commercialized as electrical energy storage devices in many common applications. Unlike lithium, sodium (Na) is both easy to find and is inexpensive, with wide supplies of precursors available on land and from salt water through desalination. Hybrid sodium ion capacitors and dedicated high power sodium ion batteries (NIBs) are emerging extremely fast charge time systems that employ two-dimensional carbon electrodes to store the charge. They are finding use in regenerative braking energy storage for cars, busses and public rail. To date, fast charge storage mechanisms in two-dimensional carbons are not understood. This combined experimental – simulation research will provide new fundamental insight into these unexplored but essential aspects of Na storage. A range of carbon structures and chemistries will be analyzed using advanced methods, including neutron scattering and first principles simulation. This work will yield the first new series of scientific insights on where in the carbon structure the Na ions reside and on their transport characteristics.

25 ENERGY STORAGE↗

Solving the duck curve in a smart grid environment using a non-cooperative game theory and dynamic pricing profiles

With the intermittency that comes with electricity generation from renewables, utilizing dynamic pricing will encourage the demand-side to respond in a smart way that would minimize the electricity costs and flatten the net electricity demand curve. Determining the optimal dynamic pricing profile that would leverage distributed storage to flatten the curve is a novel idea that needs to be studied. Moreover, the economic feasibility of utilizing distributed electrical energy storage is still not given in the literature. Therefore, in this paper, a novel way of solving a citywide dynamic model using a bilevel programming algorithm is introduced. The problem is developed as a novel non-cooperative Stackelberg game that utilizes air-conditioning systems and electrical storage through the end-users to determine the optimal dynamic pricing profile. The results show that the combined effect of utilizing demand-side air-conditioning systems and distributed storage together can flatten the curve while employing the optimal dynamic pricing profile. An economic study is performed to determine the economic feasibility of 20 different cases with different battery designs and the level of solar penetration. Three metrics were used to evaluate the economic performance of each case: the levelized cost of storage, the levelized cost of energy, and the simple payback period. Most cases had levelized cost of storage values lower than 0.457 $/kWh, which is the lower bound available in the literature. Seven out of 16 cases have a simple payback period shorter than the lifetime of the system (25 years). The case with a 100 MW PV power plant and a battery storage of size 597 MWh, was found to be the most promising case with a simple payback period of 12.71 years for the photovoltaic plant and 19.86 years for the demand-side investments.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Durian-Inspired Design of Bismuth–Antimony Alloy Arrays for Robust Sodium Storage

Sodium-ion batteries have attracted widespread attention for cost-effective and large-scale electric energy storage. However, their practical deployment has been largely retarded by the lack of choice of efficient anode materials featuring large capacity and electrochemical stability and robustness. Herein, we report a durian-inspired design and template-free fabrication of a robust sodium anode based on triangular pyramid arrays of Bi 0.75 Sb 0.25 alloy electrodeposited on Cu substrates. The Bi 0.75 Sb 0.25 arrays exhibit an appreciable electrochemical robustness for sodium storage, sustaining a reversible capability 335 mAh g –1 at a high rate of 2.5 A g –1 and 87% of the initial capacity over 2000 cycles. We further demonstrate the applicability of the Bi 0.75 Sb 0.25 array anode in sodium full cells by pairing it with a Na 3 V 2 (PO 4 ) 3 /C cathode. This full cell achieves a high specific energy of 203 Wh kg –1 (based on both active electrodes). Such an enhanced performance is attributed to the thorny-durian-like architecture and bimetallic alloy composition. In conclusion, the pyramid tip induces ion enrichment for rapid charge-transfer reaction, while the alloy design reduces the electrode volume swelling for stable Na cycling.

25 ENERGY STORAGE↗

A Computational Framework for Energy Storage Participation in Transmission Planning with Electricity Market Participation

Energy storage technologies—including pumped storage hydropower (PSH), batteries, and other technologies—have been technically proven to be capable of providing transmission services by regulating power flows and providing voltage support. These technologies will potentially increase the flexibility of transmission infrastructure and may defer (or eliminate) the need for transmission upgrades or new investments. On the regulatory side, Congress and the Federal Energy Regulatory Commission (FERC) have issued several orders over decades that have established energy storage’s (ES) eligibility as a transmission asset. The orders have required transmission planning entities to provide a level playing field where ES can participate in the transmission planning process (TPP) without undue discrimination and preference of technology. These developments pave the way for ES to participate in transmission planning as a transmission asset. On the other hand, as a flexible resource, ES can play an important role in the electricity market to enable more renewable energy integration by providing energy and grid reliability services. This could bring more revenue in return.

25 ENERGY STORAGE↗

The Impact of Behind-the-Meter Heterogeneous Distributed Energy Resources on Distribution Grids: Preprint

The increasing integration of distributed energy resources (DERs) on the electric grid brings new challenges and opportunities for utility grid operations. With the rapid deployment of DERs, there is emerging interest in integrating these controllable devices with utility operations at all levels for monitoring and management. Different types of DERs such as Photovoltaics (PV), energy storage, electric vehicles (EVs), etc. have varying effects on the grid based on how and where they are deployed. Again, the DER deployment and its impact are network-dependent, while the traditional electric grids were not designed to host DERs. To understand the challenges with increasing behind-the-meter (BTM) DERs and to identify the needs in deploying advanced controls, a comprehensive grid impact study is indispensable. This paper investigates the impacts of integrating a mix of DERs in the utility distribution network in Colorado, U.S. Firstly, BTM DERs at the residential scale including distributed PV; battery energy storage systems (BESS); heating, ventilation, and air-conditioning (HVAC) load; electric water heater (EWH) load; and EVs are modeled. The impacts of integrating these resources on the distribution network are evaluated by conducting time-series simulations for different scenarios considering different days to capture the worst-case conditions. Monte Carlo simulations are conducted to generate the realistic EV charging profile. The voltage issues, substation transformer loadings, and critical nodes in the network are identified with the incorporation of uncoordinated EV charging loads and other DER in the network. This analysis helps visualize the DER impact on the grid, identify the challenges, and provides an insight into the new distribution management and control needs to enable reliable and resilient distribution grid operations. Additionally, further analysis is performed to estimate the daily residential electricity cost with the inclusion of DERs under time-of-use tariffs. The result shows the daily residential electricity cost reduced by 20:7% on average with DERs compared to the case without DERs.

27 ARPA - Advanced Research Projects Agency-Energy↗