Design Didn't Prevent These Hazard Exposures

Two recent electrical incidents demonstrate how the design of equipment encouraged electrical workers to take actions that violated NFPA 70E principles. The features that encouraged non-compliant work execution will be described, as well as how the equipment was improved to facilitate safe work practices. Design-stage processes that help identify features that will foster rather than compromise safe work practices will be identified as well.

Mertz, David E. [Fermilab] (ORCID:0009000068872719↗

EVI-LOCATE User Manual

One of the longest stages in the deployment of electric vehicle supply equipment (EVSE) is the initial planning of the infrastructure itself. Engineers and fleet experts from the National Renewable Energy Laboratory (NREL) have supported dozens of charging infrastructure site plans over the past couple decades, including the generation of site schematics, determinations of electric capacity, and estimates for likely costs. As the market for electric vehicles (EVs) has matured, this approach should no longer require a time and personnel intensive process. In order to shorten the time taken to develop site plans and cost estimates, NREL developed a tool that fleet managers, facility managers, electricians, EVSE installers, and members of the public can use to develop initial schematics and ballpark pricing for charging station installations. The Electric Vehicle Infrastructure - Locally Optimized Charger Assessment Tool and Estimator (EVI-LOCATE) provides a structured and consistent way for users to enter information about their planned EVSE project in a relatively simple web-based format. EVI-LOCATE then calculates electrical equipment capacity, wiring runs, and project costs. It produces a site diagram optimized around surface characteristics with differential trenching costs for softscape such as grass compared to hardscape such as asphalt that can be adjusted by users in the tool. It also stores the resulting site plans and costs in a dashboard for access at a later date, including plan revisions if necessary. This document guides users through the EVI-LOCATE screens and associated questions. It contains tip text boxes throughout on how best to interface with the tool and find additional information or context. The appendices contain the assumptions and calculations underpinning the tool. Much of the information for EVI-LOCATE was gathered through industry engagements with EVSE installers, invoices from completed EVSE installations, Gordian's RS Means construction data, and the General Services Administration blanket purchase agreement for EVSE. For a visual tutorial of the tool, users can watch EVI-LOCATE Step-by-Step Video. The tool itself is available at https://evi-locate.nrel.gov.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Electric Vehicle Charging Data Falsification Attacks Utilizing Behavioral Models

A charging station (CS) and its associated electric vehicle supply equipment (EVSE) and charging electric vehicle (EV) interactions are potential targets for data falsification attacks since CSs are typically unmanned public facilities that are connected to the internet and EVs incorporate the vulnerable CAN bus network, which are both susceptible to remote attacks. The research question being addressed is how is the EV owner and CS negatively affected by CAN bus EV battery current sensor and battery temperature sensor data falsification attacks. Negative effects include economic losses from reduced life span of the battery, battery thermal runaway and fire (and potential loss of surrounding structure), and reduced utilization of the CS due to delayed departure time (longer charging times).

25 ENERGY STORAGE↗

Evaluations of Connectors, Inlets, and Adapters on Side-Load and Withstand Force

This report examines the mechanical forces that direct current fast charging (DCFC) electric vehicle supply equipment (EVSE) connectors and electric vehicle (EV) inlet ports experience during normal usage. As we witness the fast and growing variety of EVs, charge port locations, and bigger and more powerful EVSE configurations including the SAE J3400 North American Charging Standard (NACS), which has increased the use of adapters with J3400 and J1772 compatibility. These new conditions contribute to increased mechanical forces due to their size, weight and lever arm effect, which creates the need to study and compare these forces to the limits on UL2251 and IEC 62196-1 standards. This report focuses solely on high power DC charging EVSE connectors, EV inlets and adapters for the specific compatibility cases on J3400 with J1772. We first describe the details of the 100N and the 750N side-load evaluations as described in the standards, then present the data obtained by replicating these tests to finally go into more detail on the findings and our recommendations.

100N↗

Evolution of Plug-In Electric Vehicle Charging Infrastructure in the United States: Preprint

The U.S. Department of Energy’s Alternative Fuels Data Center (AFDC) has tracked alternative fueling and electric vehicle charging infrastructure in the United States since 1991. This paper explores the history of the AFDC Station Locator, which was launched in 1999, and discusses the growth of electric vehicle supply equipment. It also looks at how electric vehicle drivers access public charging, and evaluates challenges, gaps, and opportunities facing both electric vehicle drivers and the industry as a whole.

ADVANCED PROPULSION SYSTEMS↗

Preconceptual Designs of Coupled Power Delivery between a 4-Loop PWR and 100-500 MWe HTSE Plants

This study develops a preconceptual design for the integration between a large-scale high-temperature electrolysis facility and a NPP. Two hydrogen facility sizes are considered: 100 MWnom and 500 MWnom. Both steam supply designs use cold reheat steam extraction as a heat source. A reboiler inside the protected area of the power plant transfers steam heat to the demineralized water supply for the hydrogen plant. After the heat transfer, the extracted steam condenses and returns to the condenser while the process steam routes out of the protected area to the electrolyzers. Electrical power is tapped off from the high voltage side of the GSU transformer, where it is then transported via a 345-kV transmission line to the hydrogen facility. Circuit breakers and disconnects are located at both ends of the transmission line. Step down transformers and miscellaneous switchgear/buses are located at the end of the transmission line inside the HTEF boundary. Control capabilities for the steam interfacing equipment and electrical dispatch are accessible from the Main Control Room, and protective relays for the transmission line are located inside the Relay Room. Computer modeling was performed for the thermal and electrical designs. PEPSE analysis provided the steady-state parameters for thermal extraction from the turbine cycle. These parameters were used to inform transients and size equipment in combination with Applied Flow Technology (AFT) Arrow and AFT Fathom modeling for steam and water piping, respectively. Electrical transients were analyzed using PSCAD. An ETAP model was used to evaluate power flow and short circuit, which enabled the sizing of transformers and protective equipment. A cost estimate was developed for both integration designs when considering plant separation distances of 250 m and 500 m. From these estimates, the modifications for thermal and electrical interfacing of a first-of-a-kind nuclear-integrated hydrogen facility are anticipated to cost between $60–250/kWnom., where the subscript “nom” refers to the nominal size of the hydrogen plant. On a thermal power basis, the thermal power has a cost of approximately $8/MWth for a 500 MWnom high temperature electrolysis plant located 500 m distant from the NPP. That value decreases to approximately $7.5/MWth for a 250 m separation distance between the hydrogen plant and the NPP. This value is lower than previous estimates of the cost of heat extracted from NPPs primarily because in this work the steam is extracted from cold reheat instead of the main steam line, which reduces the cost of the dispatched steam by approximately $3.5/MWth. Nuclear steam extraction can provide a profit avenue for many plants and is not restricted to hydrogen production. Ammonia production, oil refining, and paper production, among other industrial processes all require thermal energy, which can be provided by NPPs. Future work should look further at the details of thermal extraction for a variety of use cases. This can include increased levels of extraction and multiple simultaneous users. Additionally, site-specific studies should be performed to develop industry experience and improve cost accuracy.

08 HYDROGEN↗

A Scalable Quantum Cryptography Network for Protected Automation Communication (Final Report)

This is the final report for a CEDS-funded project aimed at developing a new quantum technology for securing utility communication networks used to control and monitor electrical grid equipment. Securing these control networks represents a unique challenge as the performance of the security solution has a direct impact on the stability and reliability of the electrical grid. Traditional, software-based solutions - developed for information networks - are not suitable for utility control networks because they introduce latency, require burdensome maintenance and upgrades, are often incompatible with legacy equipment, and introduce operational complexity that reduces grid reliability. Consequently, many U.S. utilities do not use existing solutions and, instead, protect their critical control networks through the careful isolation and obscuration of their networked equipment. With more utilities embracing grid automation, the attack surface that utilities must defend from hackers has grown to an unmanageable size. To address this situation, Qubitekk and its partners proposed and developed a hardware-based solution that can secure critical control networks without negatively impacting grid performance. This new solution is based on quantum key distribution (QKD) techniques that guarantee secure key generation and distribution across a utility control network. Through deployment and field testing of a prototype QKD system, we have shown that this solution delivers long-term network security, is technically feasible to implement and maintain on a utility’s distribution substation network and does not negatively impact grid operations. In addition, the project has identified and solved key challenges associated with generating, transmitting, and measuring coherent photonic quantum states on a real-world fiber optic network. These additional findings are playing a critical role in advancing quantum networks for quantum computing applications. An overview of the QKD prototype development effort, field testing activities and results, and additional findings relevant to emerging quantum networks are presented in this report.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Energy, power, and infrastructure demands from electrifying airport ground support equipment at United States airports

As the airline industry seeks to reduce costs and transition to clean energy, electric ground support equipment is emerging as a favorable option. The integration of electric ground support equipment into airport operations requires careful planning for vehicle deployment, charging infrastructure, and grid impacts. We develop a flexible, bottom-up modeling framework to assess energy and infrastructure needs across more than 300 U.S. airports. Our analysis estimates site-specific power and energy demand, equipment counts by type, charger requirements, and costs. Here we quantify the magnitude of new electrical loads created by the electrification of airport ground support equipment, finding that peak power demand at the largest airports can reach up to 20 megawatts, with annual electricity consumption approaching 51,000 megawatt-hours. We further show that behind-the-meter battery energy storage systems and solar photovoltaic systems can reduce peak load and lower total system costs by as much as 10 million dollars.

24 POWER TRANSMISSION AND DISTRIBUTION↗

EVs@Scale: NextGen Profiles EVSE Characterization 2025

As part of the U.S. DOE EVs@Scale consortium, the Next-Generation Profiles (NextGen Profiles [NGP]) project presents analysis and results from the characterization of high-power conductive and wireless charging infrastructure. High Power Charging equipment is capable of recharging electric vehicle traction batteries at power levels of 200KW and above. Electric Vehicle Service Equipment (EVSE) characterization involves testing over a wide range of DC charging currents and voltages during nominal and off-nominal conditions. This testing allows for a better understanding of the impact that high-power charging will have on the electric grid. A common set of standard test plans, procedures, and data requirements were applied to the characterization in this document with minor updates and improvements. This report covers all conductive characterization activities performed between October 2024 and September 2025 on the Delta Electronics 350KW Electric Vehicle Charging System, consisting of power cabinet model EIDN-U350KTA01 and dispenser model EIDD-U350SSUUAEG-350.Key Findings include: Output regulation, Efficiency and power factor, Load management, Grid Resilience, Smart Charge Management (SCM) performance, Thermal control system performance, Multi-port simultaneous charging performance, and Selected performance comparisons with other EVSEs characterized in the NextGen Profiles project. Hot and cold temperature testing was not conducted on the Delta 350KW due to laboratory limitations. Future research could include continued testing the Delta hardware under off-nominal temperature conditions including multi-port/multi-session simultaneous charge testing, in addition to collecting data on other high-power conductive chargers to augment.

25 ENERGY STORAGE↗

CB10412: Bulk CWA Destruction

The objective of this project was to eliminate and/or render bulk agent unusable by a threat entity via neutralization and/or polymerization of the bulk agent using minimal quantities of additives. We proposed the in situ neutralization and polymerization of bulk chemical agents (CAs) by performing reactions in the existing CA storage container via wet chemical approaches using minimal quantities of chemical based materials. This approach does not require sophisticated equipment, fuel to power generators, electricity to power equipment, or large quantities of decontaminating materials. By utilizing the CA storage container as the batch reactor, the amount of logistical resources can be significantly reduced. Fewer personnel are required since no sophisticated equipment needs to be set up, configured, or operated. Employing the CA storage container as the batch reactor enables the capability to add materials to multiple containers in a short period of time as opposed to processing one container at a time for typical batch reactor approaches. In scenarios where a quick response is required, the material can be added to all the CA containers and left to react on its own without intervention. Any attempt to filter the CA plus material solution will increase the rate of reaction due to increased agitation of the solution.

36 MATERIALS SCIENCE↗

A Preliminary Investigation on the Performance of a Dual-Source Heat Pump using both the Air and the Ground

Air source heat pumps (ASHPs) and ground source heat pumps (GSHPs) are the two most common types of electric-driven heat pumps in the marketplace to replace fossil fuel-based heating systems. However, the performance and efficiency of ASHPs depend on the ambient air conditions. Therefore, ASHPs usually are equipped with electric resistance heaters to provide supplemental heating when the ambient temperature is low, and the heating demand is high. The electric resistance heaters could result in high power draws when they are turned on. On the other hand, due to the relatively steady temperature of the ground, GSHPs are more energy efficient than ASHPs when providing space heating and cooling to the buildings. However, the adoption of GSHP is hindered by its high initial cost, mostly due to the cost of drilling boreholes for installing ground heat exchangers (GHE). To solve the above issues, our study investigates the performance of dual-source heat pumps (DSHPs) with respect to that of ASHPs and GSHPs. The DSHP will use ambient air when its temperature is favorable for the efficient operation of the heat pump. When the ambient temperature is too hot or too cold, the ground source will be utilized to retain the high-efficiency operation of the heat pump. Because the cumulative thermal load of the GHE is shared with the ambient air, the size of the GHE could be smaller than those of the conventional GSHPs. The study will model the DSHP and simulate its performance in providing heating and cooling for a typical single-family house in regions with hot, mild, or cold climates. In addition, the required GHE size of the DSHP system will be determined through annual simulations and compared with that of conventional GSHPs.

Anees, Fady↗

Case Study: BESS Capacity Building for Malawi

To strengthen Malawi's national electricity grid and to enhance reliability, the government of Malawi and the Electricity Supply Corporation of Malawi are partnering with the Global Alliance for People and Planet to develop a 20-megawatt/30-megawatt-hour battery energy storage system at Kanengo, Malawi, expected to come online in 2026. In parallel, the Global Energy Alliance for People and Planet and the National Laboratory of the Rockies implemented a comprehensive technical capacity-building program to equip the Electricity Supply Corporation of Malawi, the Malawi Energy Regulatory Authority, and the Malawi University of Business and Applied Sciences with the expertise needed to plan, regulate, and operate advanced storage systems.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Reliable, High Power Density Inverters for Heavy Equipment Applications

With this final report, the combined team of the University of Arkansas (UA), University of Illinois, Urbana-Champaign (UIUC), Wolfspeed, Caterpillar, and Ampaire have successfully met all of their project objectives. Noteworthy for the heavy equipment portion of the project with Caterpillar is that the team made its project milestones two years into the project by designing a power dense motor drive for a permanent magnet synchronous machine. Upon finding out that Caterpillar had pivoted to switched-reluctance machines (SRMs), the team subsequently redesigned and implemented the SRM drive with a coolant temperature of 105°C! The other major task that the UA, UIUC, and Wolfspeed teams took on was the design of a PMSM drive for a hybrid aircraft that was flown on Feb. 20, 2023 by Ampaire after extensive testing and evaluation. While there were also technical objectives in thermal management, integrated gate drivers, reliability studies, and high temperature capacitors with integrated bussing, each of these have been fully reported on in quarterly reports. In brief, advances in thermal management and high temperature capacitors were utilized in order to achieve a 105°C motor drive. The integrated gate driver work resulted in a higher density drive with no loss of efficiency. Most of the last year, during a no-cost extension, was spent waiting for the Ampaire motor drive to be tested (outside of our project). Many months passed with the device just sitting in California while the company dealt with battery-related issues. This delayed the integration and testing activities until Fall 2022. Once those began, then the process took about 4-5 months to complete culminating in the test flight in Feb. 2023. By providing technical advances and integration into final platforms, the barrier to economic impact has been lowered. This project benefits the public by overcoming key technical barriers to electrified and hybrid electric heavy equipment and aircraft. This, in turn, leads to lower greenhouse gas emissions and a cleaner environment. This final report summarizes the integrated gate driver work and the Ampaire hybrid electric aircraft integration and test flight efforts. All other information has been previously reported in quarterly reports. A summary of the motor drives created during this project is provided along with a listing of publications.

42 ENGINEERING↗

Development of Real-Time System Identification to Detect Abnormal Operations in a Gas Turbine Cycle

Here, we present a novel online system identification methodology for monitoring the performance of power systems. This methodology was demonstrated in a gas turbine recuperated power plant designed for a hybrid configuration. A 120-kW Garrett microturbine modified to test dynamic control strategies for hybrid power systems designed at the National Energy Technology Laboratory (NETL) was used to implement and validate this online system identification methodology. The main component of this methodology consists of an empirical transfer function model implemented in parallel to the turbine speed operation and the fuel control valve, which can monitor the process response of the gas turbine system while it is operating. During fully closed-loop operations or automated control, the output of the controller, fuel valve position, and the turbine speed measurements were fed for a given period of time to a recursive algorithm that determined the transfer function parameters during the nominal condition. After the new parameters were calculated, they were fed into the transfer function model for online prediction. The turbine speed measurement was compared against the transfer function prediction, and a control logic was implemented to capture when the system operated at nominal or abnormal conditions. To validate the ability to detect abnormal conditions during dynamic operations, drifting in the performance of the gas turbine system was evaluated. A leak in the turbomachinery working fluid was emulated by bleeding 10% of the airflow from the compressor discharge to the atmosphere, and electrical load steps were performed before and after the leak. This tool could detect the leak 7 s after it had occurred, which accounted for a fuel flow increase of approximately 15.8% to maintain the same load and constant turbine speed operations.

algorithms↗

Estimating the Breakeven Cost of Delivered Electricity to Charge Class 8 Electric Tractors

As vehicle electrification expands from the light-duty sector to include larger commercial medium- and heavy-duty vehicles, businesses need to decide if electrification is appropriate for their fleets. A key factor in this decision will be the total cost of ownership for on-road electric Class 8 tractors compared to their combustion counterparts. This report examines the breakeven price of electricity for electric Class 8 tractor charging to address its importance in the total cost of ownership for the operation of an electrified fleet and to account for the inherent differences of higher-power charging. To understand the likely cost of delivered energy--in this report the breakeven price--to charge electric tractors, this study followed an analysis framework that considers a wide range of factors to estimate the breakeven price to charge at various station types. This requires an estimation of electric vehicle adoption trajectories and analysis of real-world fleet data to assess energy needs of heavy-duty electric tractors and to determine expected charging station demand over time. Station demand informs the level of electric vehicle supply equipment (EVSE) deployment that is necessary at each station type, as well as the site utilization and anticipated load profiles. Then, by accounting for a wide range of capital investments, operating costs, and other expenses, a breakeven price of energy is determined.

33 ADVANCED PROPULSION SYSTEMS↗

Optimizing Power Line Undergrounding Decisions under Varying Wildfire Risk and Weather Scenarios

Abstract—The threat of wildfire ignitions from electric power equipment has led utilities to increasingly turn to preemptive power shutoffs, which, while effective in reducing grid-induced wildfire risk, can cause significant load loss. Undergrounding power lines is an alternative strategy for preventing grid-induced wildfires. However, undergrounding lines is costly, so an efficient undergrounding plan must balance reductions in wildfire risk and load loss with the cost of undergrounding lines. We propose a robust optimization model to identify which power lines to underground to maximize load served while limiting wildfire risk across a range of wildfire risk and weather scenarios. Since solving this problem may be computationally heavy for large power grids and many operating scenarios, we present a delayed constraint generation algorithm to iteratively add scenarios until an optimal solution is found. We evaluate the performance of this framework on the RTS-GMLC with scenarios representing a year of operating conditions and compare it with a stochastic programming formulation. Our results indicate that our undergrounding model is successful in reducing load shed and risk compared to baseline cases in which no mitigation action is taken and only power shutoffs are implemented (no undergrounding). The robust formulation also reduces more load shed than the stochastic formulation in the most extreme scenarios. Index Terms—grid resilience, optimization, transmission systems, underground power lines, wildfire risk.

Taylor, S. [Department of Electrical and Computer ↗

Determining spectral response of the National Ignition Facility particle time of flight diagnostic to x rays

The Particle Time of Flight (PTOF) diagnostic is a chemical vapor deposition diamond detector used for measuring multiple nuclear bang times at the National Ignition Facility. Due to the non-trivial, polycrystalline structure of these detectors, individual characterization and measurement are required to interrogate the sensitivity and behavior of charge carriers. In this paper, a process is developed for determining the x-ray sensitivity of PTOF detectors and relating it to the intrinsic properties of the detector. We demonstrate that the diamond sample measured has a significant non-homogeneity in its properties, with the charge collection well described by a linear model ax + b, where a = 0.63 ± 0.16 V –1 mm –1 and b = 0.00 ± 0.04 V –1 . Finally, we also use this method to confirm an electron to hole mobility ratio of 1.5 ± 1.0 and an effective bandgap of 1.8 eV rather than the theoretical 5.5 eV, leading to a large sensitivity increase.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

End-Use Savings Shapes Measure Documentation: Thermostat Control for Load Shedding in Large Offices

This documentation focuses on a single End-Use Savings Shape measure - thermostat control for load shedding. The thermostat control for load shedding measure applies heating and cooling temperature setpoint offsets for reducing the heating and cooling load during peak window. The measure takes daily peak load schedule inputs generated by the method "Dispatch Schedule Generation" described in the "Supplemental Documentation: Dispatch Schedule Generation for Demand Flexibility Measures" to determine the start and end times of the peak window, and then adjusts the thermostat cooling and/or heating setpoints by an offset value from original schedules during the peak window to reduce the HVAC or whole building daily peak load. The measure is flexible and allows users to adjust the heating and cooling offset values respectively, but for this study, the adjustment for heating and cooling setpoints are set to -2 degrees Celsius and +2 degrees Celsius by default. The measure provides options of adding rebound control period (default 2 hours) after peak windows for the setpoints to be ramped back to default values, to prevent the system from generating higher peak demand with step changes of setpoints in post-peak periods . This measure is applicable t o large offices equipped with electric HVAC system (either electric cooling only or both electric heating and cooling), which account for approximately 8.72% of the ComStock floor area. The thermostat control for load shedding measure demonstrates 2-5% daily peak demand reduction and 0.068% total site energy savings (3 trillion British thermal units [TBtu]) for the U.S. commercial building stock modeled in ComStock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗