Miniature Reversal Electron-Attachment Detector

Miniature reversal electron-attachment detector (miniREAD) enables direct injection of air or vapor at atmospheric pressure from monitored area into mass-spectrometric instrument to detect explosives, narcotics, or other substances, vapors of which suspected of being present in low concentrations. In comparison with older reversal electron-attachment detector, miniREAD simpler in design; more rugged; and easier to build, repair, and maintain. In addition, probably more sensitive.

Chutjian, Ara↗

Enhanced neutron detector and electron amplifier structure and a method of fabricating the enhanced neutron detector and electron amplifier structure

An enhanced electron amplifier structure includes a substrate configured to amplify a signal of an incident particle by causing a cascade of secondary electron emissions and an enhancement layer configured to increase a sensitivity of the substrate to the incident particle. The enhancement layer is provided on an upper surface of the substrate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Direction-Sensitive Detector for Electron Antineutrinos

A modular design is proposed for an electron antineutrino detector based on boron-doped liquid scintillator. Tests have been carried out on small detector systems using neutrons to simulate the antineutrino detection signature. Results from these tests are reported, and the possibility of using a larger system of similar design to detect reactor antineutrinos is discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The electronics and data acquisition system for the DarkSide-50 veto detectors

DarkSide-50 is a detector for dark matter candidates in the form of weakly interacting massive particles. It utilizes a liquid argon time projection chamber for the inner main detector, surrounded by a liquid scintillator veto (LSV) and a water Cherenkov veto detector (WCV). The LSV and WCV act as the neutron and cosmogenic muon veto detectors for DarkSide-50. This paper describes the electronics and data acquisition system used for these two detectors. The system is made of a custom built front end electronics and commercial National Instruments high speed digitizers. The front end electronics, the DAQ, and the trigger system have been used to acquire data in the form of zero-suppressed waveform samples from the 110 PMTs of the LSV and the 80 PMTs of the WCV. The veto DAQ system has proven its performance and reliability. This electronics and DAQ system can be scaled and used as it is for the veto of the next generation DarkSide-20k detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of Large Area Gas Electron Multiplier Detector and Its Application to a Digital Hadron Calorimeter for Future Collider Experiments

The UTA High Energy Physics Group conducted generic detector development based on large area, very thin and high sensitivity gas detector using gas electron multiplier (GEM) technology. This is in preparation for a use as a sensitive medium for sampling calorimeters in future collider experiments at the Energy Frontier as well as part of the tracking detector in Intensity Frontier experiments. We also have been monitoring the long term behavior of one of the prototype detectors (30cmx30cm) read out by the SLAC-developed 13-bit KPiX analog chip over three years and have made presentations of results at various APS meetings. While the important next step was the development of large area (1m x 1m) GEM planes, we also have looked into opportunities of applying this technology to precision tracking detectors to significantly improve the performance of the Range Stack detector for CP violation experiments and to provide an amplification layer for the liquid Argon Time Projection Chamber in the LBNE experiment. We have jointly developed 33cmx100cm large GEM foils with the CERN gas detector development group to construct 33cm x100cm unit chambers. Three of these unit chambers will be put together to form a 1m x 1m detector plane. Following characterization of one 33cmx100cm unit chamber prototype, a total of five 1m x 1m planes will be constructed and inserted into an existing 1m3 RPC DHCAL stack to test the performance of the new GEM DHCAL in particle beams. The large area GEM detector we planned to develop in this proposal not only gives an important option to DHCAL for future collider experiments but also the potential to expand its use to Intensity Frontier and Cosmic Frontier experiments as high efficiency, high amplification anode planes for liquid Argon time projection chambers. Finally, thanks to its sensitivity to X-rays and other neutral radiations and its light-weight characteristics, the large area GEM has a great potential for the use in medical imaging and homeland security, as well as satellite based astronomy experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Analytical modeling and numerical simulation of the short-wave infrared electron-injection detectors

This paper describes comprehensive analytical and simulation models for the design and optimization of the electron-injection based detectors. The electron-injection detectors evaluated here operate in the short-wave infrared range and utilize a type-II band alignment in InP/GaAsSb/InGaAs material system. The unique geometry of detectors along with an inherent negative-feedback mechanism in the device allows for achieving high internal avalanche-free amplifications without any excess noise. Physics-based closed-form analytical models are derived for the detector rise time and dark current. Our optical gain model takes into account the drop in the optical gain at high optical power levels. Furthermore, numerical simulation studies of the electrical characteristics of the device show good agreement with our analytical models as well experimental data. Performance comparison between devices with different injector sizes shows that enhancement in the gain and speed is anticipated by reducing the injector size. Sensitivity analysis for the key detector parameters shows the relative importance of each parameter. The results of this study may provide useful information and guidelines for development of future electron-injection based detectors as well as other heterojunction photodetectors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A 28 nm multiply-accumulate ASIC architecture for on-chip data compression in MHz frame rate X-ray and electron pixel detectors

Modern X-ray detector systems urgently require compact, efficient, and fast data compression schemes to handle the transmission of big data from pixel arrays, enabling frame rates in the MHz regime. Here, in this work, a data compression ASIC that implements a streaming fixed-length lossy compression scheme is introduced and analyzed, proving the feasibility and benefits of on-chip compression. The compression scheme utilizes a vector matrix product logic, which performs a number of floating-point multiplications, additions, and accumulations. The logic is verified, synthesized, and shown to fit in the area resource available for the X-ray detector under study, which comprises 192 × 168 pixels each of 12-bit width, and having a total area of 20 mm× 20 mm, about 2 mm× 20 mm of which are available for the digital logic. Several system architectures, precisions, and compression ratios ranging from 100 to 250 were analyzed to pave the way for on-chip fixed-length compression (e.g., principal component analysis, singular value decomposition) and data reduction (e.g., azimuthal integration) for X-ray and electron detectors.

Data compression↗

Comparative Response of Microchannel Plate and Channel Electron Multiplier Detectors to Penetrating Radiation in Space

Channel electron multiplier (CEM) and microchannel plate (MCP) detectors are routinely used in space instrumentation for measurement of space plasmas. Here, our goal is to understand the relative sensitivities of these detectors to penetrating radiation in space, which can generate background counts and shorten detector lifetime. We use 662 keV γ-rays as a proxy for penetrating radiation such as γ-rays, cosmic rays, and high-energy electrons and protons that are ubiquitous in the space environment. We find that MCP detectors are ~20 times more sensitive to 662 keV γ-rays than CEM detectors. This is attributed to the larger total area of multiplication channels in an MCP detector that is sensitive to electronic excitation and ionization resulting from the interaction of penetrating radiation with the detector material. In contrast to the CEM detector, whose quantum efficiency ε γ for 662 keVγ -rays is found to be 0.00175 and largely independent of detector bias, the quantum efficiency of the MCP detector is strongly dependent on the detector bias, with a power law index of 5.5. Lastly, background counts in MCP detectors from penetrating radiation can be reduced using MCP geometries with higher pitch and smaller channel diameter.

79 ASTRONOMY AND ASTROPHYSICS↗

Direct-Write Printing on Three-Dimensional Geometries for Miniaturized Detector and Electronic Assemblies

Aerosol Jet Printing (AJP) and other additive electronics technologies will enable new detector assemblies that were not previously possible with traditional assembly processes. This technology has the potential to reduce mass and volume for fabrication and assembly of detector, instrument and electronics concepts by reducing trace widths down to 10 microns, printing on complex geometries, and allowing new concept production. This poster summarizes development efforts of printed interconnects for space applications.

Printed Hybrid Electronics↗

Graphene vertical hot-electron terahertz detectors

We propose and analyze the concept of the vertical hot-electron terahertz (THz) graphene-layer detectors (GLDs) based on the double-GL and multiple-GL structures with the barrier layers made of materials with a moderate conduction band off-set (such as tungsten disulfide and related materials). The operation of these detectors is enabled by the thermionic emissions from the GLs enhanced by the electrons heated by incoming THz radiation. Hence, these detectors are the hot-electron bolometric detectors. The electron heating is primarily associated with the intraband absorption (the Drude absorption). In the frame of the developed model, we calculate the responsivity and detectivity as functions of the photon energy, GL doping, and the applied voltage for the GLDs with different number of GLs. The detectors based on the cascade multiple-GL structures can exhibit a substantial photoelectric gain resulting in the elevated responsivity and detectivity. The advantages of the THz detectors under consideration are associated with their high sensitivity to the normal incident radiation and efficient operation at room temperature at the low end of the THz frequency range. Such GLDs with a metal grating, supporting the excitation of plasma oscillations in the GL-structures by the incident THz radiation, can exhibit a strong resonant response at the frequencies of several THz (in the range, where the operation of the conventional detectors based on A{sub 3}B{sub 5} materials, in particular, THz quantum-well detectors, is hindered due to a strong optical phonon radiation absorption in such materials). We also evaluate the characteristics of GLDs in the mid- and far-infrared ranges where the electron heating is due to the interband absorption in GLs.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SUBMM wave superconduction hot-electron direct detectors

Recently, we have presented a concept for a hot-electron direct detector (HEDD) capable of counting single millimeter-wave photons. Such a detector meets the needs of future space far-infrared applications and can be used for background-limited detector arrays on missions like SPIRIT, 10-m filled aperture telescope, SAFIR, and SPECS.

hot-electron electron-phonon direct detectors subm↗

Development of a fast framing detector for electron microscopy

A high frame rate detector system is described that enables fast real-time data analysis of scanning diffraction experiments in scanning transmission electron microscopy (STEM). This is an end-to-end development that encompasses the data producing detector, data transportation, and real-time processing of data. The detector will consist of a central pixel sensor that is surrounded by annular silicon diodes. Both components of the detector system will synchronously capture data at almost 100 kHz frame rate, which produces an approximately 400 Gb/s data stream. Low-level preprocessing will be implemented in firmware before the data is streamed from the National Center for Electron Microscopy (NCEM) to the National Energy Research Scientific Computing Center (NERSC). Live data processing, before it lands on disk, will happen on the Cori supercomputer and aims to present scientists with prompt experimental feedback. This online analysis will provide rough information of the sample that can be utilized for sample alignment, sample monitoring and verification that the experiment is set up correctly. Only a compressed version of the relevant data is then selected for more in-depth processing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Proposed electron halo detector system as one of the beam overlap diagnostic tools for the new RHIC electron lens

An electron lens for head-on beam-beam compensation planned for RHIC requires precise overlap of the electron and proton beams which both can have down to 0.3 mm rms transverse radial widths along the 2m long interaction region. Here we describe a new diagnostic tool that is being considered to aid in the tuning and verification of this overlap. Some of ultra relativistic protons (100 or 250 GeV) colliding with low energy electrons (2 to 10 keV) will transfer sufficient transverse momentum to cause the electrons to spiral around the magnetic guiding field in a way that will make them detectable outside of the main solenoid. Time-of-flight of the halo electron signals will provide position-sensitive information along the overlap region. Scattering cross sections are calculated and counting rate estimates are presented as function of electron energy and detector position.

43 PARTICLE ACCELERATORS↗

Improved Scintillator Materials for Compact Electron Antineutrino Detectors

Developments in the fields of chemistry and materials science provide new components that hold the potential to improve the performance of liquid scintillation electron antineutrino detectors used for the monitoring of nuclear reactors. New compounds can provide for more efficient, stable, and safer operation of these detectors. Current detectors and their detector materials raise issues regarding size, quantum efficiency, stability, and spatial resolution for the vertex detection. For compact detectors (1 m{sup 3} active volume) improvement of these issues with existing liquid scintillation cocktails can be obtained by means of developing stable and efficient neutron capture agents. These agents comprise of boron or lithium containing coordination compounds, in addition advances in fluorescence detection technologies and optimization of solvent characteristics can improve the overall efficiency. Focus points of the new detector material design are to enable a compact, robust, and direction sensitive electron antineutrino detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Hot-electron Direct Detector for Radioastronomy

A hot-electron transition-edge superconducting bolometer with adjustable thermal relaxation speed is proposed. The bolometer contacts are made from a superconductor with high critical temperature which blocks the thermal diffusion of hot carriers into the contacts. Thus electron-phonon interaction is the only mechanism for heat removal. The speed of thermal relaxation for hot electrons in a nanometer-size superconducting bolometer with T(sub c) = 100-300 mK is controlled by the elastic electron mean free path l. The relaxation rate behaves as T(sup 4)l at subkelvin temperatures and can be reduced by a factor of 10-100 by decreasing 1. Then an antenna- or wave guide-coupled bolometer with a time constant approx. = 10(exp -3) to 10(exp -4) s will exhibit photon-noise limited performance at millimeter and submillimeter wavelengths. The bolometer will have a figure-of-merit NEPtau = 10(exp -22) - 10(exp -21) W/Hz at 100 mK which is 10(exp 3) to 10(exp 4) times better (ie: smaller) than that of a state-of-the-art bolometer. A tremendous increase in speed and sensitivity will have a significant impact for observational mapping applications.

Karasik, Boris S.↗