Search NASA⌕ Search

SEARCH · Search NASA

Results for “ELECTROOPTICS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Unique properties of SBN and their use in a layered optical memory

Holographic storage experiments using crystal Sr(0.75)Ba(0.25)Nb2O6 (SBN 75/25) as a volume-phase holographic medium show that this material is the most sensitive crystalline storage medium yet discovered. An exposure level of 0.003 J/sq cm at 0.488 micron produces a 1% diffraction efficiency in a 5-mm length of crystal. In addition to high recording sensitivity, SBN 75/25 exhibits interesting electric-field induced effects that include electric-field enhanced recording sensitivity and voltage-switchable latent-to-active holographic reconstruction efficiency. These effects are explained in terms of drift and diffusion of photoionized carriers coupled with the nonlinear electrooptic behavior characteristic of this low Curie temperature ferroelectric crystal. A mechanism is proposed that correlates the observed electrically controlled holographic response with the dielectric behavior of the crystal. These interesting effects are used to implement a novel, layered optical memory having no moving parts and having electrical access for writing or reading selected layers.

Thaxter, J. B.↗

Crystal growth in fused solvent systems

The successful nucleation of bismuth germanate, B12GeO20 on a high quality seed and the growth of regions of single crystals of the same orientation of the seed are reported. Lead germanate, Pb5Ge3O11 was also identified as a ferroelectric crystal with large electrooptic and nonlinear optic constants. Solvent criteria, solvent/development, and crystal growth are discussed, and recommendations for future studies are included.

Ulrich, D. R.↗

Minimization of the prime power consumption of a coupling-modulated gas laser transmitter

The present article addresses itself to the prime power requirements of a coupling-modulated gas laser transmitter. The latter consists of a gas discharge tube and electrooptic modulator inside a laser resonator. In performing the calculations, the laser discharge length and the modulator voltage are simultaneously varied so that the transmitted power remains constant. In this way, tradeoffs can be made between the prime power supplied individually to the discharge tube and to the modulator driver to obtain a transmitter configuration that minimizes the total prime power consumption. An analytical expression is derived that describes the effects of information bandwidth and transmitter output power on the prime power requirements. Specific numerical results are obtained for a CO2 laser transmitter based on presently available experimental data.

Degnan, J. J.↗

Approach guidance for outer planet Pioneer missions

An overall parametric system analysis of the use of an optical approach guidance measurement system (using a V-slit electrooptical 'star-pipper') onboard a Pioneer-type spin-stabilized spacecraft for outer planet missions. Optical measurements of satellites of Saturn and Uranus against the star background are considered. Measurement geometry and spacecraft attitude are evaluated in depth with respect to two Pioneer missions: Saturn-Uranus and Jupiter-Uranus atmospheric entry probe missions with departure from Earth in November/December, 1980. A preliminary evaluation of long-term attitude stability measurements of Pioneer 10 is presented in the Appendix. The major conclusions are: (1) at Saturn flyby, viewing some medium period satellites can provide the best measurement results. (2) At Uranus approach, viewing the planet may give best measurements if early bus-probe separation is required. (3) Final measurement accuracy depends on the data format transmitted to Earth and the applied data interpretation techniques.-

Bejczy, A. K.↗

Holographic recording materials - A review

Holographic recording materials in current use are examined along with a few of their applications. Some experimental media are also studied. No effort is made to rank the commercial materials, since satisfactory results can be obtained with any of them. The discussion covers silver halide plates and films, photoresists, thermoplastics, photopolymers, dichromated gelatin, photochromic materials, electrooptical crystals, styryl free radical film, and TEP film. A convenient summation of some material properties is presented in tabular form.

Kurtz, R. L.↗

A photon counting array photometer using an intensified charge coupled device

An array photometer which uses an intensified charge coupled device was developed. This system, the University of Maryland Array Photometer (UMAP), has the ability to discriminate single photoelectron events in real time at a 4 Megahertz rate. The photosensor uses an S-20 photocathode and a Fairchild CCD202 with a 100 by 100 array of separate individual channels. The overall system has demonstrated a noise level which permits single photoelectron discrimination, a scan rate of 400 frames per second, a very linear response, and very low lag. The UMAP system has a very large dynamic range exceeding 10,000 in the photon counting mode. A special technique to extend the dynamic range to 1,000,000 was described. The performance parameters of this system, both in the laboratory and on the telescope were cited. Data from these observations were discussed to illustrate the system sensitivity, which is basically limited by the pixel size in the array, rather than the electrooptics.

Currie, D. G.↗

A photon-counting multichannel spectrometer

A multichannel detector system is described in which the positions of individual photon events in a high-gain image intensifier are decoded in the output of a video detector. The high-gain intensifier consists of a pair of three-stage electrostatic image-tube assemblies each containing three fiber-optically-coupled tubes potted in a rugged package with an internal high-voltage supply. Operation of the electrooptical system is discussed along with the pulse-detection process and the operation of the spectrograph in which the image-tube assembly is mounted. It is noted that the spectrometer detects 1.0 count/sec per A for an object of magnitude 13.0 at the peak of its response in the visual band when no light is lost on the slit, that a 10% coincidence correction is reached at an overall count rate of 860 per sec, and that the response follows an exponential law up to count rates of about 4000 per sec. The measured spectrum of the Seyfert galaxy NGC 5548 is provided as an example of the raw data produced by the instrument on a 1.5 meter telescope.

Shectman, S. A.↗

Optically activated switch/modulator using a photoconductor and two channel waveguides

An optically activated switch was fabricated on LiNbO3 substrate by deposition of photoconductor-metal electrode structure on two channel waveguides obtained by the outdiffusion process. One waveguide was overcoated with a CdS film, and served as a light detector which converted the optical signal in that waveguide into an electric signal. Utilizing the electrooptic effect, this electric signal modulated the light propagating in the second waveguide by changing the refractive index, and the cutoff condition, of the waveguiding channel between two metal electrodes. The waveguides in the optically controlled switch can be either single or multimode. The length of the device can be short in comparison with other switching schemes. When binary optical signals are applied to the two waveguides, the switch can perform logic AND, NEGATION, OR and pseudo-amplification operations.

Goldberg, L.↗

Applications of pilot scanning behavior to integrated display research

The oculometer is an electrooptical device designed to measure pilot scanning behavior during instrument approaches and landing operations. An overview of some results from a simulation study is presented to illustrate how information from the oculometer installed in a visual motion simulator, combined with measures of performance and control input data, can provide insight into the behavior and tactics of individual pilots during instrument approaches. Differences in measured behavior of the pilot subjects are pointed out; these differences become apparent in the way the pilots distribute their visual attention, in the amount of control activity, and in selected performance measures. Some of these measured differences have diagnostic implications, suggesting the use of the oculometer along with performance measures as a pilot training tool.

Waller, M. C.↗

Advances in laser technology for the atmospheric sciences; Proceedings of the Seminar, San Diego, Calif., August 25, 26, 1977

These papers deal with recent research, developments, and applications in laser and electrooptics technology, particularly with regard to atmospheric effects in imaging and propagation, laser instrumentation and measurements, and particle measurement. Specific topics include advanced imaging techniques, image resolution through atmospheric turbulence over the ocean, an efficient method for calculating transmittance profiles, a comparison of a corner-cube reflector and a plane mirror in folded-path and direct transmission through atmospheric turbulence, line-spread instrumentation for propagation measurements, scaling laws for thermal fluctuations in the layer adjacent to ocean waves, particle sizing by laser photography, and an optical Fourier transform analysis of satellite cloud imagery. Other papers discuss a subnanosecond photomultiplier tube for laser application, holography of solid propellant combustion, diagnostics of turbulence by holography, a camera for in situ photography of cloud particles from a hail research aircraft, and field testing of a long-path laser transmissometer designed for atmospheric visibility measurements.

Trolinger, J. D.↗

An integrated optical preprocessor for multichannel analog data

As a precursor to the construction of a 16-channel device, a 3-channel integrated optical data preprocessor has been fabricated and tested. The device, which is fabricated in an outdiffused LiNbO3 waveguide, provides a signal related to the channel-by-channel difference between a prerecorded reference set and an incoming data set which is presented in the form of parallel analog voltages. The data are impressed upon the guided wave as a set of electrooptically induced phase shifts, and the comparison to the reference set is performed by holographic subtraction. The reference set can either be introduced as a separate operation or it can be 'learned' by the preprocessor during operation.

Verber, C. M.↗

Fabrication and testing of a three-channel integrated optical data preprocessor

As a precursor to the construction of a 16-channel device, a 3-channel integrated optical data preprocessor has been fabricated and tested. The device, which is fabricated in an outdiffused LiNbO3 waveguide, provides a signal related to the channel-by-channel difference between a prerecorded reference set and an incoming data set which is presented in the form of parallel analog voltages. The data are impressed upon the guided wave as a set of electrooptically induced phase shifts, and the comparison to the reference set is performed by holographic subtraction. The reference set can either be introduced as a separate operation or it can be 'learned' by the preprocessor during operation.

Verber, C. M.↗

Design, fabrication and testing of an optical temperature sensor

The laboratory breadboard optical temperature sensor based on the temperature dependent absorptive characteristics of a rare earth (europium) doped optical fiber. The principles of operation, materials characterization, fiber and optical component design, design and fabrication of an electrooptic interface unit, signal processing, and initial test results are discussed. Initial tests indicated that, after a brief warmup period, the output of the sensor was stable to approximately 1 C at room temperature or approximately + or - 0.3 percent of point (K). This exceeds the goal of 1 percent of point. Recommendations are presented for further performance improvement.

Morey, W. W.↗

Proceedings of the 25th International Instrumentation Symposium, May 7-10, 1979, Anaheim, California

The papers deal essentially with the instrumentation needs of the transportation industry, machinery diagnostics, and energy research. The sessions covered include: acoustic emission, reentry vehicle ground and flight testing, performance of nose tip materials, instrumentation for solar heating and cooling systems, vibration measurement, data acquisition and analysis, system for aerospace pressure measurements, wind tunnel instrumentation and control, energy source instrumentation, nondestructive testing, pressure and flow measurements, automated test facilities, strain measurements, electrooptical instrumentation, thermal measurements, microcomputer applications in instrumentation and automation, flight testing, blast pressure measurement, two-phase liquid/gas mass flow measurement, and machinery monitoring and instrumentation.

Conferences↗

Proposed smart integrated-optical preprocessor using holographic subtraction

The paper presents a proposed integrated-optical preprocessor with a holographic subtraction. It is based on an optical analog of a set of N analog voltages formed by passing an optical plane wave, confined in an electrooptic waveguide, under a set of N electrodes to which the voltages are applied; in the limit in which diffraction is ignored, the wavefront of the emerging guided wave will have superimposed upon it N discrete phase shifts. Processors which operate upon voltages encoded in this manner are being fabricated; they include a comparator in which incoming data are compared to a holographic record of the optical analog of a reference set, and a 'smart' system based upon holographic self-subtraction, in which the processor can independently adapt to changes in background information. The preprocessor operation is described in the screening, identification, and the self-subtraction modes, and implementation of devices in an integrated optical configuration is discussed.

Verber, C. M.↗

Aliasing and blurring in 2-D sampled imagery

The quality of image reconstructions from discrete data suffers not only from the blurring of spatial detail caused by limitations in the spatial frequency response of electrooptical systems, but also from the aliasing generated if spatial detail has been undersampled. Previous studies have observed that reasonable spot intensity profiles and photosensor aperture shapes of equivalent size result in about equal blurring but that some profiles and shapes suppress aliasing better than others. This paper presents quantitative results of the magnitude of aliasing and blurring as a function of random radiance fields typical for natural scenes and of spatial responses and sampling intervals typical for TV cameras and optical-mechanical scanners. These results indicate that aliasing may often be a larger source of degradation than either blurring or electronic noise.

Huck, F. O.↗

Electronic recording of holograms with applications to holographic displays

The paper describes an electronic heterodyne recording which uses electrooptic modulation to introduce a sinusoidal phase shift between the object and reference wave. The resulting temporally modulated holographic interference pattern is scanned by a commercial image dissector camera, and the rejection of the self-interference terms is accomplished by heterodyne detection at the camera output. The electrical signal representing this processed hologram can then be used to modify the properties of a liquid crystal light valve or a similar device. Such display devices transform the displayed interference pattern into a phase modulated wave front rendering a three-dimensional image.

Claspy, P. C.↗

The spectral opacity of triatomic carbon measured in a graphite tube furnace over the 280 to 600 nm wavelength range

The paper presents the measurements of linear triatomic carbon opacity (C3) made in a graphite tube furnace to extend the wavelength range of Brewer and Engelke (1962) to the 280-600 nm range. An electrooptical method was used to determine C3 absorption in argon at 2720 to 3060 K; a quartic polynomial regression expression was derived to provide a complete temperature profile from pyrometer measurements. The C3 spectra were plotted for several opacity levels. It was concluded that the extension of the spectral range to the near u.v. levels made it easier to identify C3 particles.

Snow, W. L.↗