Search NASA⌕ Search

SEARCH · Search NASA

Results for “ESys”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

HPLC/ESI-quadrupole ion trap mass spectrometry for characterization and direct quantification of amphoteric and nonionic surfactants in aqueous samples

An amphoteric (cocamidopropylbetaine, CAPB) and a nonionic (alcohol polyethoxylate, AE) surfactant were characterized by electrospray ionization quadrupole ion trap mass spectrometry (ESI-MS) as to their homologue distribution and ionization/fragmentation chemistry. Quantitative methods involving reversed-phase gradient HPLC and (+)ESI-MSn were developed to directly determine these surfactants in hydroponic plant growth medium that received simulated graywater. The predominant homologues, 12 C alkyl CAPB and 9 EO AE, were monitored to represent the total amount of the respective surfactants. The methods demonstrated dynamic linear ranges of 0.5-250 ng (r2 > 0.996) for CAPB and 8-560 ng (r2 > 0.998) for AE homologue mixture, corresponding to minimum quantification limits of 25 ppb CAPB and 0.4 ppm AE with 20-microL injections. This translated into an even lower limit for individual components due to the polydispersive nature of the surfactants. The procedure was successfully employed for the assessment of CAPB and AE biodegradation in a hydroponic plant growth system used as a graywater bioreactor.

NASA Discipline Life Support Systems↗

Simultaneous quantification of poly-dispersed anionic, amphoteric and nonionic surfactants in simulated wastewater samples using C18 high-performance liquid chromatography-quadrupole ion-trap mass spectrometry

This paper describes the development of a guantitative method for direct and simultaneous determination of three frequently encountered surfactants, amphoteric (cocoamphoacetate, CAA), anionic (sodium laureth sulfate, SLES), and nonionic (alcohol ethoxylate, AE) using a reversed-phase C18 HPLC coupled with an ESI ion-trap mass spectrometer (MS). Chemical composition, ionization characteristics and fragmentation pathways of the surfactants are presented. Positive ESI was effective for all three surfactants in agueous methanol buffered with ammonium acetate. The method enables rapid determinations in small sample volumes containing inorganic salts (up to 3.5 g L(-1)) and multiple classes of surfactants with high specificity by applying surfactant specific tandem mass spectrometric strategies. It has dynamic linear ranges of 2-60, 1.5-40, 0.8-56 mg L(-1) with R2 egual or greater than 0.999, 0.98 and 0.999 (10 microL injection) for CAA, SLES, and AE, respectively.

Chromatography, High Pressure Liquid/methods↗

LC/MS Method for the Determination of Stable Isotope Labeled Promethazine in Human Plasma

Promethazine (PMZ) is taken by astronauts orally (PO), intramuscularly (IM) or rectally (PR) for space motion sickness. LC/MS method was developed with off-line solid phase extraction to measure plasma concentrations of PMZ given as stable isotope-labeled (SIL) formulations by the three different routes of administration simultaneously. Samples (0.5ml) were loaded on to Waters Oasis HLB co-polymer cartridges and eluted with 1.0 mL methanol. HPLC separation of the eluted sample was performed using an Agilent Zorbax SB-CN column (50 x 2.1 mm) at a flow rate of 0.2 mL/min for 6 min. Acetonitrile/ ammonium acetate (30 mM) in water (3:2, v/v), pH 5.6 plus or minus 0.1, was used as the mobile phase for separation. Concentrations of PMZ, PMZ-d4 and PMZ-d7 and chlorpromazine (internal standard) were determined using a Micromass ZMD single quadrupole mass spectrometer with Electrospray Ionization (ESI). ESI mass spectra were acquired in positive ion mode with selected ion monitoring of [M+ H]dot plus. The method is rapid, reproducible and the assay specific parameters are listed in a table. A novel, sensitive and specific method for the measurement of PMZ and SIL PMZ in human plasma is reported.

Zuwei, Wang↗

Determination of Scopolamine in Human Saliva Using Solid Phase Extraction and LC/MS/MS

Purpose: Scopolamine is the preferred treatment for motion sickness during space flight because of its quick onset of action, short half-life and favorable side-effect profile. The dose administered depends on the mode of administration and usually ranges between 0.1 and 0.8 mg. Such small doses make it difficult to detect concentrations of scopolamine in biological fluids by using conventional HPLC methods. To measure scopolamine in saliva and thereby to evaluate the pharmacokinetics of scopolamine, we developed an LC/MS/MS method using off-line solid phase extraction. Method: Samples (0.5mL) were loaded onto Waters Oasis HLB co-polymer cartridges (10 mg, 1 mL) and eluted with 0.5 mL methanol without evaporation and reconstitution. HPLC separation of the eluted sample was performed using an Agilent Zorbax SB-CN column (50 x 2.1 mm) at a flow rate of 0.2 mL/min for 4 minutes. The mobile phase for separation was 90:10 (v/v) methanol: ammonium acetate (2 mM) in water, pH 5.0 +/- 0.1. Concentrations of scopolamine were determined using a Micromass Quattro Micro(TM) mass spectrometer with electrospray ionization (ESI). ESI mass spectra were acquired in positive ion mode with multiple reaction monitoring for the determination of scopolamine m/z = 304.2 yields 138.1 and internal standard (IS) hyoscyamine m/z = 290.2 yields 124.1. Results: The method is rapid, reproducible, specific and has the following parameters: scopolamine and the IS are eluted at 1.7 and 3.2 min respectively. The linear range is 50-5000 pg/mL for scopolamine in saliva with correlation coefficients > 0.99 with a CV < 0.5 %. The intra-day and inter-day CVs are < 15 % for quality control samples with concentrations of 75, 300, 750 and 3000 pg/mL of scopolamine in human saliva. Conclusion: Solid phase extraction allows more rapid sample preparation and greater precision than liquid extraction. Furthermore, we increased the sensitivity and specificity by adjusting the LC mobile phase and using an MS/MS detector.

Wang, Zuwei↗

A Modified LC/MS/MS Method with Enhanced Sensitivity for the Determination of Scopolamine in Human Plasma

Intranasal scopolamine is a choice drug for the treatment of motion sickness during space flight because of its quick onset of action, short half-life and favorable sideeffects profile. The dose administered usually ranges between 0.1 and 0.4 mg. Such small doses make it difficult to detect concentrations of scopolamine in biological fluids using existing sensitive LC/MS/MS method, especially when the biological sample volumes are limited. To measure scopolamine in human plasma to facilitate pharmacokinetic evaluation of the drug, we developed a sensitive LC/MS/MS method using 96 well micro elution plates for solid phase extraction (SPE) of scopolamine in human plasma. Human plasma (100-250 micro L) were loaded onto Waters Oasis HLB 96 well micro elution plate and eluted with 50 L of organic solvent without evaporation and reconstitution. HPLC separation of the eluted sample was performed using an Agilent Zorbax SB-CN column (50 x 2.1 mm) at a flow rate of 0.2 mL/min for 3 minutes. The mobile phase for separation was 80:20 (v/v) methanol: ammonium acetate (30 mM) in water. Concentrations of scopolamine were determined using a Micromass Quattro Micro(TM) mass spectrometer with electrospray ionization (ESI). ESI mass spectra were acquired in positive ion mode with multiple reaction monitoring for the determination of scopolamine m/z = 304.2 right arrow 138.1 and internal standard hyoscyamine m/z = 290.2 right arrow 124.1. The method is rapid, reproducible, specific and has the following parameters: scopolamine and the IS are eluted at about 1.1 and 1.7 min respectively. The linear range is 25-10000 pg/mL for scopolamine in human plasma with correlation coefficients greater than 0.99 and CV less than 0.5%. The intra-day and inter-day CVs are less than 15% for quality control samples with concentrations of 75,300, and 750 pg/mL of scopolamine in human plasma. SPE using 96 well micro elution plates allows rapid sample preparation and enhanced sensitivity for the LC/MS/MS determination of scopolamine in a small volume of biological samples. The new method is also cost effective since it uses a small volume of organic solvents compared to the methods using SPE cartridges or regular 96 well SPE plates. This method can be successfully used for bioavailability and pharmacokinetic evaluations of scopolamine, especially when volumes of biological samples are limited. Further investigation to use automated SPE system with 96 well micro elution plates is planned.

Wang, Zuwei↗

The Dragonfly Entry and Descent System

Dragonfly is a proposed New Frontiers class mission that will send a nuclear powered octocopter to the surface of Titan for an extended science mission. This presentation will provide an overview of the Entry and Descent system that is under development to ensure the save delivery of this unique "relocatable lander" to Titan. Titan's dense atmosphere, large atmospheric scale height, and low gravity allows for a slow-paced entry and descent sequence that lasts more than 100 minutes, as opposed to the "7 minutes of terror" that is charac-teristic of landed Mars missions. This slow pace al-lows for sufficient temporal separation between critical events of the EDL sequence to minimize overall risk.The Dragonfly entry and descent system is composed of high-heritage components, minimizing overall risk. The aeroshell will be a scaled Genesis Sample Return capsule with a diameter of 3.75 meters, built by Lock-heed Martin. The thermal protection system (TPS) is made up of Phenolic Impregnated Carbon Ablator-Domestic (PICA-D) on the heatshield, SLA-561V on the backshell, and SLA-220M on the aft cover and low gain antenna. Each material has extensive heritage for the chosen application. The spacecraft will enter Titan at a velocity of 7.3 km/s, resulting in a predicted fully margined stagnation point heating environment of 254 W/cm2 heat rate and 13 kJ/cm2 heat load, well within the tested limits of the chosen materials. The aeroheat-ing environments, including the significant contribu-tion of shock layer radiation from CN on both the heatshield and backshell, are evaluated using state of the art models and codes that have been validated with appropriate ground testing.Once the deceleration pulse is complete, a disk-gap-band (DGB) drogue parachute will be deployed at ap-proximately Mach 1.5 to stabilize and further deceler-ate the spacecraft. Due to the dense atmosphere, the spacecraft will spend more than 80 minutes on this parachute, until reaching an appropriate altitude to de-ploy the subsonic main parachute. The lander is re-leased after approximately 17 minutes on the main chute before releasing and transitioning to powered flight in order to navigate to its first landing site. The release of the lander from the backshell effectively ends the entry and descent portion of the mission.The full presentation will provide additional details about the design of the EDL system hardware, engi-neering design, and overall con-ops. Preliminary aero-thermal and TPS sizing analyses will be presented, and the parachute system will be described in greater detail. In addition, the Dragonfly spacecraft will carry an En-gineering Science Investigation (ESI) package designed to obtain engineering data during EDL that will be used to validate the design methodology for future missions. An overview of the proposed ESI package will also be presented.

EDL↗

Exploiting the Convergence of Evidence in Satellite Data for Advanced Weather Index Insurance Design

The goal of drought-related weather index insurance (WII) is to protect smallholder farmers against the risk of weather shocks and to increase their agricultural productivity. Estimates of precipitation and vegetation greenness are the two dominant satellite datasets. However, ignoring additional moisture- and energy-related processes that influence the response of vegetation to rainfall leads to an incomplete representation of the hydrologic cycle. This study evaluates the added value of considering multiple independent satellite-based variables to design, calibrate, and validate weather insurance indices on the African continent. The satellite data include two rainfall datasets, soil moisture, the evaporative stress index (ESI), and vegetation greenness. We limit artificial advantages by resampling all datasets to the same spatial (0.25°) and temporal (monthly) resolution, although datasets with a higher spatial resolution might have an added value, if considered as the single source of information for localized applications. A higher correlation coefficient between the moisture-focused variables and the normalized difference vegetation index (NDVI), an indicator for vegetation vigor, provides evidence for the datasets’ capability to capture agricultural drought conditions on the ground. The Climate Hazards Group Infrared Precipitation with Stations (CHIRPS) rainfall dataset, soil moisture, and ESI show higher correlations with the (lagged) NDVI in large parts of Africa, for different land covers and various climate zones, than the African Rainfall Climatology, version 2 (ARC2), rainfall dataset, which is often used in WII. A comparison to drought years as reported by farmers in Ethiopia, Senegal, and Zambia indicates a high “hit rate” of all satellite-derived anomalies regarding the detection of severe droughts but limitations regarding moderate drought events.

drought↗

Leveraging High Resolution Remotely Sensed Evapotranspiration Data to Assess Water Availability and Vulnerability in the Memphis Aquifer Area in West Tennessee

The Memphis aquifer is an indispensable source of water for municipal, agricultural, and industrial use across west Tennessee. The aquifer's water is thousands of years old and in pristine condition due to the natural geological filtering by the aquifer’s confining clay layers. To sustain the aquifer’s water supply, recharge must happen at a rate efficient enough to keep up with pumping from the aquifer. In partnership with Protect Our Aquifer and the University of Memphis Center for Applied Earth Science and Engineering Research, this project examined multiple factors to discover thriving areas of recharge in west Tennessee. The team used Integrated Multi-satellite Retrievals for GPM (IMERG) precipitation data, ECOsystem Spaceborne Thermal Radiometer on Space Station (ECOSTRESS) evapotranspiration data, Landsat 8 and National Land Cover Database (NLCD) to track landcover change, and the North American Land Data Assimilation System (NLDAS) Noah land surface model to estimate monthly runoff. These factors were averaged seasonally from 2019 to 2022 to understand seasonal relationships within the study area. Precipitation and evapotranspiration data were used to create water balance maps and with the evaporative stress index (ESI), landcover, and runoff maps, the team pinpointed locations that are most conducive to recharge. The team determined that areas where the water balance is low, ESI is high, and where there is sufficient pervious landcover are locations where recharge happens most effectively. Identification of effective recharge locations may be used by the partners to prioritize areas in need of protection before they become impacted by industrialization and urbanization.

Lauren Webster↗

Flash Drought Onset and Development Mechanisms Captured With Soil Moisture and Vegetation Data Assimilation

Flash droughts evolve and intensify rapidly under the influence of anomalous atmospheric conditions. In this study, we investigate the role of assimilating remotely sensed soil moisture (SM) and vegetation properties in capturing the evolution and impacts of two flash droughts in the Northern Great Plains. We find that during 2016 drought triggered by anomalously high temperatures and excessive evaporative demands, multivariate data assimilation (DA) of MODIS-derived leaf area index (LAI) and Soil Moisture Active Passive SM within Noah-Multiparameterization model helps capture elevated transpiration at onset. Assimilation of LAI particularly helped model the resulting rapid decline in SM during onset with as high as 10.0% steeper rate of decline compared to the simulation without any assimilation. Modeled-SM anomalies exhibit a 7.5% and 11.7% increase in similarity with Evaporative Stress Index (ESI) data and U.S. Drought Monitor (USDM) maps, respectively. In contrast, during 2017 flash drought driven by record-low precipitation during summers, SM assimilation resulted in largest rates of decline in rootzone SM, as large as 48.4% compared to results from no assimilation. Multivariate DA of SM and LAI results in 6.7% and 14.3% higher spatial similarity with ESI and USDM, respectively, and is necessary to model rapid intensification caused by anomalous precipitation deficits. This study elucidates the need to incorporate multiple observational constraints from remote sensing to effectively capture rapid onset rates, intensification, and severity of flash drought following different propagation mechanisms. This is fundamental for drought early detection to provide a wider window of response and implement efficient mitigation strategies.

Shahryar K. Ahmad↗

Presence of aromatic-rich organic matter and its characterization in grout materials: Implications for radionuclide immobilization

Grout materials are commonly used to immobilize low-level radioactive waste. Organic moieties can be unintentionally present in common ingredients used to make these grout waste forms, which may result in the formation of organo-radionuclide species. These species can positively or negatively affect the immobilization efficiency. However, the presence of organic carbon compounds is rarely considered in models or characterized chemically. Here, we quantify the organic pool of grout formulations with and without slag, as well as the individual dry ingredients used to make the grout samples (ordinary Portland cement (OPC), slag and fly ash), including total organic carbon (TOC) and black carbon, followed by aromaticity evaluation and molecular characterization via Electro Spray Ionization Fourier-Transform Ion Cyclotron Resonance Mass Spectrometry (ESI-FTICRMS). All dry grout ingredients contained significant amounts of organic carbon, ranging from 550 mg/kg to 6250 mg/kg for the TOC pool, with an averaged abundance of 2933 ± 2537 mg/kg, of which 60 ± 29% was composed of black carbon. The significant abundance of a black carbon pool implies the presence of the aromatic-like compounds, which was further identified by both phosphate buffer-assisted aromaticity evaluation (e.g., >1000 mg-C/kg as aromatic-like carbon in the OPC) and dichloromethane (DCM) extraction with ESIFTICRMS analysis. Besides aromatic-like compounds, other organic moieties were also detected in the OPC, such as carboxyl-containing aliphatic molecules. While the organic compound only consists of minor fractions of the grout materials investigated, our observations of the presence of various radionuclide-binding organic moieties suggests the potential formation of organo-radionuclides, such as radioiodine, which might be present at lower molar concentrations than TOC. Here, evaluating the role of organic carbon complexation in controlling the disposed radionuclides, especially for those radionuclides with strong association with organic carbon, has important implications for the long-term immobilization of radioactive waste in grout systems.

36 MATERIALS SCIENCE↗

Construction of Photo‐Responsive Pd 2 L 4 ‐Type Nanocages based on Feringa's Second‐Generation Motor and Its Guest Binding Ability for C 60

Abstract We present the construction of a M 2 L 4 ‐type metal‐organic nanocage featuring four endohedral Feringa's motor motifs and its adaptive encapsulation towards a C 60 guest molecule. The structure of the cage, though complicated on the 1 H NMR spectrum due to the adoption of mixed ligands, was unambiguously characterized with a combination of ESI‐MS, 2D DOSY, 13 C NMR and particularly the SAXS technique. The molecular motor within the cage demonstrated similar photophysical properties to the uncoordinated one, indicating the motor's function was not compromised when it was anchored in such a confined nanospace. Furthermore, the nanocage showed good guest encapsulation ability towards C 60 , and a guest induced‐fit behavior of the cage was revealed based on the extensive SAXS analysis and molecular dynamics simulation. The adaptive motorized nanocage reported here represents one of the very few examples of integrating individual motors into a discrete nanoconfined system and offers prospects to achieve its non‐equilibrium functions.

Chemistry↗

Pertechnetate/perrhenate–capped Zr/Hf–Dihydroxide Dimers: Elucidating Zr–TcO 4 Co–Mobility in the Nuclear Fuel Cycle

Spent nuclear fuel contains heavy element fission products that must be separated for effective reprocessing for a safe and sustainable nuclear fuel cycle. 93 Zr and 99 Tc are high-yield fission products that co-transport in liquid-liquid extraction processes. Here we seek atomic-level information of this co-extraction process, as well as fundamental knowledge about Zr IV (and Hf IV ) aqueous speciation in the presence of topology-directing ligands such as pertechnetate (TcO 4 – ) and non-radioactive surrogate perrhenate (ReO 4 – ). In this context, we show that the flat tetrameric oxyhydroxyl-cluster [M IV 4 (OH) 8 (H 2 O) 16 ] 8+ (and related polymers) is dissociated by perrhenate/pertechnetate to yield isostructural dimers, M 2 (OH) 2 (XO 4 – ) 6 (H 2 O) 6 • 3H 2 O (M=Zr/Hf IV ; X=Re/Tc VII ), elucidated by single-crystal X-ray diffraction. We used these model compounds to understand the pervasive 93 Zr- 99 Tc coextraction with further speciation studies in water, nitric acid, and tetrabutylphosphate (TBP) -kerosene; where the latter two media are relevant to nuclear fuel reprocessing. SAXS (small angle X-ray scattering), compositional evaluation, and where experimentally feasible, ESI-MS (electrospray ionization mass spectrometry) showed that perrhenate/pertechnetate influence Zr/Hf IV -speciation in water. Here, in Zr-XO 4 solvent extraction studies to simulate fuel reprocessing, we provide evidence that TcO 4 – enhances extraction of Zr IV , and compositional analysis of the extracted metal-complexes (Zr-ReO 4 study) is consistent with the crystallized Zr IV 2 (OH) 2 (Re VII O 4 – ) 6 (H 2 O) 6 •dimer.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Probing Noncovalent Interaction Strengths of Host-Guest Complexes Using Negative Ion Photoelectron Spectroscopy

Noncovalent interactions (NCIs) are crucial for the formation and stability of host-guest complexes, which have wide-ranging implications across various fields, including biology, chemistry, materials science, pharmaceuticals, and environmental science. However, since NCIs are relatively weak and sensitive to bulk perturbation, direct and accurate measurement of their absolute strength has always been a significant challenge. This concept article aims to demonstrate the gas-phase electrospray ionization (ESI)-negative ion photoelectron spectroscopy (NIPES) as a direct and precise technique to measure the absolute interaction strength, probe nature of NCIs, and reveal the electronic structural information for host-guest complexes. Here, our recent studies in investigating various host-guest complexes that involve various types of NCIs such as anion–π, (di)hydrogen bonding, charge-separated ionic interactions, are overviewed. Finally, a summary and outlook are provided for this field.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dehydration of gas-phase benzyl amine alcohols studied at atmospheric pressure

Gas-phase ion chemistry is a useful approach for the investigation of physical organic chemistry and the study of reactivity, structure, and thermochemical properties of ionic and neutral organic substrates. Herein, one-step dehydration of gas-phase benzyl amine alcohols to give benzazetidines was discovered without the use of catalysts. Mechanistic investigations of the gas-phase dehydration reactions were explored to study the possible influence of charged microdroplet acceleration during electrospray ionization (ESI) and collisions occurring during ion transfer through the atmospheric pressure interface (API) of the mass spectrometer. The product ion distribution was observed to be less sensitive to droplet effects (spray distance and voltage), and temperature of transfer capillary in the API. However, the product ion distribution exhibit high sensitivity to different S-lens radio frequency (RF) voltage of the API, providing evidence that the dehydration reaction is driven by collisions during ion transfer in the API. With this insight, we developed atmospheric pressure thermal dissociation platform that allowed thermal-induced collisions outside of the mass spectrometer when the benzyl amine alcohols are carried through a heated coiled tube. Up to 98% dissociation efficiency was achieved with the coiled tube heated to a temperature of 200 °C, yielding only the desired benzazetidine product. Finally, by performing the atmospheric pressure thermal dissociation experiment outside of the mass spectrometer, we believe it will be straightforward to collect the dehydration product.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Developing a peptide concatemer (PepCon) as a process control for LC-MS based proteomics

Quantitative concatenated peptide (QconCAT) technology is currently used for the absolute quantification of proteins of interest in a biological sample. It relies on artificially created proteins that are concatenations of different, isotopically labeled peptides. Because these isotopically labeled peptides are at a 1:1 ratio and correspond to naturally occurring peptides in the biological sample, each peptide can be used as a standard for the absolute quantitation of all proteins of interest at once. Although the QconCAT technology has utility for quantitation of known peptides in a mixture, it is not helpful for scientists who need a proteomics standard (1) that can be spiked into a protein mixture at an extremely low level, (2) that can be co-purified during sample fractionation, and (3) that is optimized for ESI used in mass spectrometry. Thus, there exists a need for an ideal standard protein that is large enough to behave as a protein but consists of multiple, concatenated copies of the same peptide, which, upon digestion, amplifies (e.g., >10-fold) into a detectable peptide species. Here, this technical report describes the development of “PepCon”, a peptide concatemer that fulfills this unmet need.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Bis(imidazole)-based cysteine labeling tool for metalloprotein assembly

Precise metal-protein coordination by design remains a considerable challenge. Polydentate, high-metal-affinity protein modifications, both chemical and recombinant, can enable metal localization. However, these constructs are often bulky, conformationally and stereochemically ill-defined, or coordinately saturated. Here, we expand the biomolecular metal-coordination toolbox with the irreversible attachment to cysteine of bis(1-methylimidazol-2-yl)ethene (“BMIE”), which generates a compact imidazole-based metal-coordinating ligand. Conjugate additions of small-molecule thiols (thiocresol and N-Boc-Cys) with BMIE confirm general thiol reactivity. The BMIE adducts are shown to complex the divalent metal ions Cu ++ and Zn ++ in bidentate (N 2 ) and tridentate (N 2 S*) coordination geometries. Cysteine-targeted BMIE modification (>90% yield at pH 8.0) of a model protein, the S203C variant of carboxypeptidase G2 (CPG2), measured with ESI-MS, confirms its utility as a site-selective bioconjugation method. ICP-MS analysis confirms mono-metallation of the BMIE-modified CPG2 protein with Zn ++ , Cu ++ , and Co ++ . EPR characterization of the BMIE-modified CPG2 protein reveals the structural details of the site selective 1:1 BMIE-Cu ++ coordination and symmetric tetragonal geometry under physiological conditions and in the presence of various competing and exchangeable ligands (H 2 O/HO – , tris, and phenanthroline). An X-ray protein crystal structure of BMIE-modified CPG2-S203C demonstrates that the BMIE modification is minimally disruptive to the overall protein structure, including the carboxypeptidase active sites, although Zn ++ metalation could not be conclusively discerned at the resolution obtained. The carboxypeptidase catalytic activity of BMIE-modified CPG2-S203C was also assayed and found to be minimally affected. Finally, these features, combined with ease of attachment, define the new BMIE-based ligation as a versatile metalloprotein design tool, and enable future catalytic and structural applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analysis of phospholipids and triacylglycerols in intravenous lipid emulsions

Intravenous lipid emulsions (ILEs) are used for parenteral nutrition, providing a vital source of essential fatty acids and concentrated energy for patients who are unable to absorb nutrients via the digestive track. They are commonly used to treat local and non-local anesthetic toxicity, and lipophilic drug overdose. ILE are composed of natural lipids, and the composition of these natural lipids can be varied based on their source. The lipids are susceptible to hydrolytic degradation with time, resulting various lipid degradation products such as Lysophosphatidylcholines (LPs), affecting the actual composition of nutrients in the formulation. As a result, the identification and quantification of lipid components, including degradation products, in ILEs are crucial in quality control. In this study, lipids from different batches of ILE Intralipid® 20%, were separated and identified using a UHPLC-ESI-QTOF system and SimLipid® high throughput lipid identification software. Out of 47 lipids identified, 34 were phospholipids (PLs) and the others were triacylglycerols (TAGs). Most of the phospholipids detected were phosphatidylcholines (PC) and Lysophosphatidylcholines (LPC). A total of 9 LPCs, 18 PCs, 6 phosphoethanolamines (PEs), and 1 sphingomyelin (SM) were identified. The LPCs concentration changed with the manufacturing date and storage time. Furthermore, this UHPLC method enabled the identification and quantification of lipids and their decomposition products in complex ILE emulsion mixtures on a single 20-minute chromatographic run.

60 APPLIED LIFE SCIENCES↗

Stable electrospray signal on a microfabricated glass chip with three-dimensional open edge and tiered depth geometries

This paper presents the microfabrication and performance of a three-dimensional electrospray ionization (ESI) emitter tip made from glass, which achieves stable current signals important for chemical analysis. Our novel microfabrication process and custom-built signal conditioning hardware provides the advantage of providing accurate features and steady signals. The fabrication process relies on standard microfabrication techniques (i.e., deposition, photolithography, and wet etching). This fabrication method involves the novel application of two layers of positive and negative photoresists in addition to Parafilm® wax tape. Open edge and tiered depth details were successfully created from a multilayer planar mask. This is a benefit for integrated miniaturized and microfluidic systems that often require micro features for their functionality but relatively large millimeter size features for their physical periphery. We demonstrate the fundamental performance of electrospray with this microfluidic chip. The emitter tip was fixed on a linear axis stage with high resolution (10 μm) to finely control the tip distance from a metal counter electrode plate. Further, a custom printed circuit board system was built to safely control four voltages applied to the microchip ports from a single high voltage power supply. To readily form the electrospray, non-aqueous solvents were used for their low viscosity and a constant voltage of +2.7 kV was applied to the sheath electrospray microchannel. The liquid being sprayed was 80/20 (v/v) methanol/acetonitrile with 0.1% acetic acid in the sheath microchannel and with ammonium acetate (10–40 mM) in its remaining microchannels. The electrospray signal was measured in response to varying the distance (1.4 to 1.6mm) between the electrospray emitter tip and a metal counter electrode plate in addition to the varying concentration of the background electrolyte, ammonium acetate. Stable and repeatable electrospray signal showed linear relationships with emitter tip distance and concentration (r 2 ≥ 0.95).

42 ENGINEERING↗