Search NASA⌕ Search

SEARCH · Search NASA

Results for “EVAPORATION RATE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Effects of a Rotating Magnetic Field on Gas Transport During Detached Crystal Growth in Space

During the detached Bridgman growth of semiconductor crystals, the melt has a short free surface which is detached from the ampoule wall near the crystal-melt interface, thus eliminating the crystal defects caused by contact with the ampoule wall. Recent modelling has indicated that initiation and continuation of detached growth depends on the rate of transport of dissolved gas from the crystal-melt interface, where gas is rejected into the melt, to the detached free surface, where evaporating gas maintains the pressure on the free surface. Here we use numerical modelling to investigate whether the application of a rotating magnetic field increases or decreases the transport of rejected gas to the detached free surface. Unfortunately the results show that a rotating magnetic field almost always decreases the evaporation rate at the detached free surface. The exception is an insignificant increase for a short period at the beginning of crystal growth for a few circumstances. The evaporation rate decreases as the strength of the rotating magnetic field is increased.

Walker, John S.↗

QCM Thermo-Gravimetric Analysis (QTGA) Comparisons

The ASTM E-1559 apparatus has been used for years at NASA/Goddard Space Flight Center (GSFC) to determine in situ outgassing rate information, as well as pertinent in situ TML and multiple VCM values. The apparatus also affords the opportunity to experimentally compute the evaporation rates of molecular species that are reemitted as the Quartz Crystal Microbalances (QCMs) are gradually warmed up at some controlled temperature. Typically the molecular mass that accumulates onto the test QCMs are a compilation of species that are outgassing from the sample due to their respective activation energies and the desorption processes that the sample undergoes at various tested temperatures. It has been speculated that if there is too much molecular buildup of condensed water vapor (ice) onto the QCM crystal that a significantly higher temperature would be needed to break these "ice" bonds. ASTM E-1559 data plots will be used to demonstrate the thermogravimetric effects of water and other miscible molecular species with various water/ice thicknesses and at different evaporation rates.

Rosecrans, Glenn↗

Analytical modeling of operating characteristics of premixing-prevaporizing fuel-air mixing passages. Volume 1: Analysis and results

A model for predicting the distribution of liquid fuel droplets and fuel vapor in premixing-prevaporizing fuel-air mixing passages of the direct injection type is reported. This model consists of three computer programs; a calculation of the two dimensional or axisymmetric air flow field neglecting the effects of fuel; a calculation of the three dimensional fuel droplet trajectories and evaporation rates in a known, moving air flow; a calculation of fuel vapor diffusing into a moving three dimensional air flow with source terms dependent on the droplet evaporation rates. The fuel droplets are treated as individual particle classes each satisfying Newton's law, a heat transfer, and a mass transfer equation. This fuel droplet model treats multicomponent fuels and incorporates the physics required for the treatment of elastic droplet collisions, droplet shattering, droplet coalescence and droplet wall interactions. The vapor diffusion calculation treats three dimensional, gas phase, turbulent diffusion processes. The analysis includes a model for the autoignition of the fuel air mixture based upon the rate of formation of an important intermediate chemical species during the preignition period.

Anderson, O. L.↗

Trends and meteorological drivers of extreme daily reservoir evaporation events in the western United States

Extreme daily evaporation from reservoir surfaces can lead to significant short-term water losses, affecting water quality, water supply, and reservoir operation strategies. Historical trends in daily reservoir evaporation events have eluded the scientific and operational communities, largely due to a lack of long-term, consistent data record. This study quantifies trends in extreme daily reservoir evaporation events at 165 major reservoirs located in the western U.S. Here, we use the place-based energy balance and aerodynamic Daily Lake Evaporation Model (DLEM) driven by multiple meteorological data products (RTMA, gridMET, Daymet) to estimate daily evaporation rates at these reservoirs from 1981 to 2022. The results—while are based on different meteorological forcing datasets—consistently indicate that the California, Lower Colorado, and Rio Grande hydrologic regions are more prone to higher daily evaporation extremes. Compared to the rest of western U.S, these three regions also experience a more pronounced increasing trend in the annual maximum daily evaporation rate, at about 0.3 mm day -1 decade -1 during 1981-2022. The results show that heat and dryness are the main drivers to the increasing trend of extreme evaporation, while extreme wind speed is the primary contributor to exceptionally high daily evaporation events across all regions. This phenomenon is particularly prominent in the arid Lower Colorado region, but less significant in the cold and humid Pacific Northwest region. We also find that the correlation between extreme wind speed and extreme evaporation degrades as the time scale increases from daily, to monthly and seasonal. Our findings have strong implications for the pattern and distribution of extreme evaporation events at the western U.S. reservoirs, and illustrate how various drivers influence extreme evaporation across different time scales.

13 HYDRO ENERGY↗

Reducing Sample Loss in Measurement of Heat of Vaporization of Ethanol/Gasoline Blends by Differential Scanning Calorimetry/Thermogravimetric Analysis

Higher gasoline Heat of Vaporization (HOV) can enable higher compression-ratio direct injection spark ignition engines by providing evaporative cooling that effectively increases fuel knock resistance. Methods to directly measure this fuel property in complex gasoline samples are not well developed. The objective of the present study was to further improve a Differential Scanning Calorimetry/Thermogravimetric Analyzer (DSC/TGA) method to measure the total and partial HOV of gasoline. Ten market gasoline samples were chosen to have a wide range of properties to assess the method's capability across the entire volatility range with an emphasis on understanding how well the method captures the initial 10 percent (%) of sample evaporation and how much sample is left unevaporated at the end of the experiment. Modifications to the sample preparation/introduction method as well as to the instrument itself were made to reduce initial sample losses which included measurements of the HOV at 10 degrees C and 5 degrees C (in a cold chamber) as well as under (uncontrolled) ambient conditions. Experimental results from the DSC/TGA were compared to calculated total HOV results based on Detailed Hydrocarbon Analysis (DHA). Results from the two methods agreed very well with the difference being 5% or less in almost every case. In addition, the repeatability of the method was investigated by analyzing samples in triplicate at the three temperatures investigated. One valuable conclusion from the study was that the lower temperatures of 10 degrees C and 5 degrees C enabled more reproducible measurements for both total and partial HOV. This improved precision may be caused by the fact that temperature control in the cold chamber was more reliable than the ambient laboratory temperature control. Additionally, cold chamber experiments, due to ergonomic limitations, did not allow for the use of a lid on the sample pan. The reproducibility of the evaporation rate was found to be highly dependent on the pan/lid fit which can vary significantly such that elimination of the lid improved measurement precision while operation at sub-ambient temperature slowed the evaporation rate. Results detailing sample preparation and instrument modifications as well as a detailed comparison of total and partial HOV results are presented.

ADVANCED PROPULSION SYSTEMS,BIOMASS FUELS↗

Preliminary study of gaseous nitrogen-liquid oxygen mixing and self cleaning

The penetration of gaseous nitrogen into liquid oxygen at a pressure of 150 psi was determined by monitoring the composition of the evaporating liquid in a nitrogen analyzer. For pressurization times of about 1 hr the penetration depth varies between 0.0024 and 0.018 in. at an evaporation rate of about 1 gal/day. These are small compared to the penetration depth of 22.2 in. measured in the 7-inch high temperature tunnel at a pressure of 1500 psi, pressurization time of 5 min, and evaporation rate of 121 gal/day.

Zuckerwar, A. J.↗

Mars Water Well Performance: Experimental Heat Transfer Results Supporting Simulations

Favorable indications of massive quantities of water on Mars have initiated studies of potential changes to human Mars missions. Using a technique known as a Rodriguez Well to melt the ice, store the resulting water in a subsurface ice cavity until needed, and then pump water to the surface for use is one potential means to effect these changes. A computer simulation of the Rodriguez Well in a terrestrial environment is one of the engineering tools being used to characterize the performance of this type of well on Mars. An experiment at the NASA Johnson Space Center gathered data for evaporation rates and convective heat transfer at Mars surface conditions so that this computer simulation could be appropriately modified to predict performance on Mars. Tests have indicated that a pool of water can be maintained at 1°C to 2° C while at Mars surface temperatures and pressures. Preliminary results for evaporation rates and convective heat transfer have been determined and are presented.

Stephen J Hoffman↗

Sensitivity of a Cloud-Resolving Model to Bulk and Explicit Bin Microphysical Schemes: Cloud Microphysics and Storm Dynamics Interactions - Part 2

Part I of this paper compares two simulations, one using a bulk and the other a detailed bin microphysical scheme, of a long-lasting, continental mesoscale convective system with leading convection and trailing stratiform region. Diagnostic studies and sensitivity tests are carried out in Part II to explain the simulated contrasts in the spatial and temporal variations by the two microphysical schemes and to understand the interactions between cloud microphysics and storm dynamics. It is found that the fixed raindrop size distribution in the bulk scheme artificially enhances rain evaporation rate and produces a stronger near surface cool pool compared with the bin simulation. In the bulk simulation, cool pool circulation dominates the near-surface environmental wind shear in contrast to the near-balance between cool pool and wind shear in the bin simulation. This is the main reason for the contrasting quasi-steady states simulated in Part I. Sensitivity tests also show that large amounts of fast-falling hail produced in the original bulk scheme not only result in a narrow trailing stratiform region but also act to further exacerbate the strong cool pool simulated in the bulk parameterization. An empirical formula for a correction factor, r(q(sub r)) = 0.11q(sub r)(exp -1.27) + 0.98, is developed to correct the overestimation of rain evaporation in the bulk model, where r is the ratio of the rain evaporation rate between the bulk and bin simulations and q(sub r)(g per kilogram) is the rain mixing ratio. This formula offers a practical fix for the simple bulk scheme in rain evaporation parameterization.

Li, Xiaowen↗

Studies on droplet evaporation and combustion in high pressures

High pressure droplet evaporation and combustion have been studied up to 15 MPa under normal and microgravity fields. From the evaporation studies, it has been found that in the supercritical environments, the droplet evaporation rate and lifetime take a maximum and a minimum at an ambient pressure over the critical pressure. Its maximum and minimum points move toward the lower ambient pressures if the ambient temperature is increased. It has been found from the combustion studies that the burning life time takes a minimum at an ambient pressure being equal to the critical pressure. It is attributable to both the pressure dependency of the diffusion rate and the droplet evaporation characteristics described above.

Sato, J.↗

Spray Diagnostics in Rocket Engines Using Phase Doppler Analyzer

Characteristics such as drop velocity, drop size, number density, volume flow rate, volume flux, and evaporation rate of the fuel spray in a rocket engine are directly related to engine performance. Several studies of shear coaxial atomization have been done in the past. However, additional work related to sprays at supercritical and transcritical conditions would be useful. The author undertook a study of the feasibility of using a phase Doppler particle analyzer (PDPA) for spray measurements in rocket engines as a part of the Summer Faculty Fellowship Program at the NASA Marshall Space Flight Center. The PDPA is a single particle counter (SPC) system based on light scattering from spherical particles. The PDPA instrument is based on refractive and reflective scattering as opposed to other instruments based on diffractive scattering. The main advantage of the PDPA instrument is its ability to provide point-wise information. The following sections describe the principle of operation of the PDPA system and the data obtained using a PDPA instrument in a spray formed by a commercially available fuel injection nozzle.

Isaac, Kakkattukuzhy M.↗

Evaluating the Impacts of NASA/SPoRT Daily Greenness Vegetation Fraction on Land Surface Model and Numerical Weather Forecasts

The NASA Short-term Prediction Research and Transition (SPoRT) Center develops new products and techniques that can be used in operational meteorology. The majority of these products are derived from NASA polar-orbiting satellite imagery from the Earth Observing System (EOS) platforms. One such product is a Greenness Vegetation Fraction (GVF) dataset, which is produced from Moderate Resolution Imaging Spectroradiometer (MODIS) data aboard the NASA EOS Aqua and Terra satellites. NASA SPoRT began generating daily real-time GVF composites at 1-km resolution over the Continental United States (CONUS) on 1 June 2010. The purpose of this study is to compare the National Centers for Environmental Prediction (NCEP) climatology GVF product (currently used in operational weather models) to the SPoRT-MODIS GVF during June to October 2010. The NASA Land Information System (LIS) was employed to study the impacts of the new SPoRT-MODIS GVF dataset on land surface models apart from a full numerical weather prediction (NWP) model. For the 2010 warm season, the SPoRT GVF in the western portion of the CONUS was generally higher than the NCEP climatology. The eastern CONUS GVF had variations both above and below the climatology during the period of study. These variations in GVF led to direct impacts on the rates of heating and evaporation from the land surface. The second phase of the project is to examine the impacts of the SPoRT GVF dataset on NWP using the Weather Research and Forecasting (WRF) model. Two separate WRF model simulations were made for individual severe weather case days using the NCEP GVF (control) and SPoRT GVF (experimental), with all other model parameters remaining the same. Based on the sensitivity results in these case studies, regions with higher GVF in the SPoRT model runs had higher evapotranspiration and lower direct surface heating, which typically resulted in lower (higher) predicted 2-m temperatures (2-m dewpoint temperatures). The opposite was true for areas with lower GVF in the SPoRT model runs. These differences in the heating and evaporation rates produced subtle yet quantifiable differences in the simulated convective precipitation systems for the selected severe weather case examined.

Bell, Jordan R.↗

Modeling of crystallization fouling on a horizontal-tube falling-film evaporator for thermal desalination

Scale formation within horizontal-tube falling-film evaporators is an important issue for thermal desalination, because of the deterioration of heat transfer performance and added maintenance costs. Predicting the fouling process is crucial for desalination plant design, operation, and maintenance. In this paper, a model is developed to predict the crystallization fouling process during seawater falling-film flow over a horizontal tube bundle. The scaling is estimated based on deposition theory, with couple heat transfer including the in-tube steam condensation, conduction through the tube wall and the scale layer, and falling-film evaporation. The spatial and temporal variations of temperature, heat transfer coefficient, and scale thickness are predicted, and the effects of variations in process parameters of steam, feed seawater, and tube properties on the scale thickness, evaporation rate, and heat transfer coefficient for falling-film evaporation are analyzed. Comparisons to existing experimental data show the scaling layer thickness falls in the general range of reported measurements, with a slight overestimation due to neglecting the delay of scaling onset under real conditions. The scale layer thickness increases dramatically as the in-tube steam pressure is increased or the seawater flow rate is decreased. In general, the scaling layer becomes thicker on the lower tubes in the tube bundle, due to the heat and mass transfer of the falling film. The effect of tube material on scaling appears mainly dependent on thermal conductivity; thus, using polymer rather than a stainless steel tube decreases scaling and evaporation rate 96% and 88%, respectively. Finally, this work has potential to guide thermal desalination plant design, material selection, and operating parameter optimization.

42 ENGINEERING↗

Numerically Relevant Timescales in the MG2 Microphysics Model

Climate models rely on parameterizations of a variety of processes in the atmospheric physics, but a common concern is that the temporal resolution is too coarse to consistently resolve the behavior that individual parameterizations are designed to capture. This study examines timescales numerically derived from the Morrison-Gettelman (MG2) microphysics as implemented within the Energy Exascale Earth System Model, version 1 (E3SMv1). Numerically relevant timescales in MG2 are derived by computing the eigenspectrum of its Jacobian. These timescales are found to often be smaller than the default 5 min time step used for MG2. The fast timescales are then heuristically connected to individual microphysics processes. By substepping a few particular rain processes within MG2, the time discretization error for those processes was considerably reduced with minimal additional expense to the overall microphysics. While this improvement has a substantial effect on the target processes and on the vertical distribution of stratiform-derived rain within E3SMv1, the overall model climate is found to not be sensitive to MG2 time step. Here, we hypothesize that this is because the surface climate does not depend strongly on certain process rates, especially MG2's rain evaporation rate.

58 GEOSCIENCES↗

Investigation of the thermophysical properties of high-melting materials with the aid of a complex of instruments

The evaporation rate, vapor pressure, heats of evaporation reaction (sublimation, dissociation), enthalpy, electrical resistance, heat capacity, emissivity, and heat conductivity of various carbides, borides, sulfides, nitrides, selenides, and phosphides were investigated. A set of high temperature high vacuum devices, calorimeters (designed for operation at 400 to 1300 K and from 1200 K), and mass spectrometers, most of which were specially developed for these studies, is described.

Bolgar, A. S.↗

Evaporation of ice in planetary atmospheres - Ice-covered rivers on Mars

The existence of ice covered rivers on Mars is considered. It is noted that the evaporation rate of water ice on the surface of a planet with an atmosphere involves an equilibrium between solar heating and radiative and evaporative cooling of the ice layer. It is determined that even with a mean Martian insolation rate above the ice of approximately 10 to the -8th g per sq cm/sec, a flowing channel of liquid water will be covered by ice which evaporates sufficiently slowly that the water below can flow for hundreds of kilometers even with modest discharges. Evaporation rates are calculated for a range of frictional velocities, atmospheric pressures, and insolations and it is suggested that some subset of observed Martian channels may have formed as ice-choked rivers. Finally, the exobiological implications of ice covered channels or lakes on Mars are discussed.

Wallace, D.↗

Evaporative winds in X-ray binaries

Evaporation of gas from the surface of HZ Her by Her X-1 and its implications regarding the mass transfer process are examined further. The powerful soft X-ray flux results in an evaporation rate greater than previous estimates. The evaporative flow is shown to be subsonic at first, with the result that the capture of evaporated gas by Her X-1 may be efficient, and the self-excited wind mechanism is possible. A criterion for stabilization of mass transfer by stellar wind mass loss is derived. Possible mechanisms for the long-period variability of HZ Her are discussed. Evaporative winds are also estimated for Sco X-1 and Cyg X-2 spectra.

Basko, M. M.↗