Search NASA⌕ Search

SEARCH · Search NASA

Results for “EXHAUST SYSTEMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Direct internal recycling fractions approaching unity

Direct internal recycling (DIR) refers to the process of recovering pure hydrogen isotopes (D/T) from helium and other impurities in the fusion plasma exhaust and directing them back to the fuel injection system. Increasing the exhaust fraction purified through DIR significantly reduces the size and cost of the tritium plant and provides additional benefits including reduced requirements for both the tritium startup inventory and tritium breeding ratio. Metal foil pumps (MFPs) are the dominant technology for this separation, relying on the concept of superpermeation. We recently demonstrated that PdCu foils operated at low temperature provide both exceptional flux and resilience to helium absorption as the DIR fraction is increased. Herein we design and demonstrate continuous and semi-batch DIR processes using PdCu MFPs. Under continuous processing, stable performance was observed for DIR fractions up to 92 %. In addition, we demonstrate a semi-batch process capable of extending the DIR fraction to unity (> 99.8 %). Under the experimental conditions described within a PdCu MFP area of ~22 m 2 would be sufficient to process the fusion exhaust with 92 % DIR fraction at expected flowrates of 100 Pa·m 3 ·s -1 for a future fusion power plant.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Liquid Salt Combined-Cycle Pilot Plant Design

The work described in this report is responsive to the Office of Fossil Energy program ‘Energy Storage for Fossil Power Generation.’ This Phase I report has been prepared by Pintail Power LLC, with support from Nexant ECA, Electric Power Research Institute (EPRI) and Southern Company Services as a deliverable for the U.S. Department of Energy for NETL Award DE-FE-00320016. The Liquid Salt Combined Cycle™ (LSCC™) technology provides large-scale energy storage integrated with Fossil Electric Generating Units (FEGUs) to meet critical needs in the energy transition by providing: • the lowest cost large-scale storage for time-shifting of renewable energy, • superior fuel efficiency to reduce GHGs from dispatchable resources, • flexible capacity and ramping to balance variability of wind and solar resources, • essential grid stability services to assure reliability of a low-carbon grid. The LSCC approach: • employs equipment that has already been proven in utility service, • uses safe, non-toxic, non-degrading, perpetual-life storage medium, • leverages and repurposes existing FEGU assets, • expands the value stack of energy storage to reduce market, financing, and commodity risks. Pintail Power has developed the LSCC technology to meet the need for reliable, efficient, and cost-effective integration of Variable Renewable Energy (VRE) into a low-carbon electric grid by coupling proven thermal energy storage with proven gas turbines, steam turbines, and heat transfer equipment. This novel approach is intended to address the key issues facing the grid and operators of renewable and fossil generating units including: • Overgeneration and curtailment of renewables, • Need for fast ramping dispatchable resources, • Improved efficiency and flexibility of fossil units, • Additional peaking capacity to support electrification of transportation and heating, • Provision of reliability services to support high penetration of VRE, especially synchronous inertia and fast frequency response. A Technology Readiness assessment by EPRI confirmed that LSCC technology consists of commercially proven hardware used in industrial and utility applications. Although the novel LSCC approach has not yet been demonstrated as a complete system, interfaces between major components have been conservatively specified. A Phase III pilot is planned to demonstrate equipment integration and operation. The patented innovation is removal of the evaporator section from the exhaust heat recovery system, with the evaporation performed by stored energy in a separate steam generator. This arrangement couples renewable and fossil power generation via long-duration energy storage to deliver cost, performance, and operational synergies, including superior charging and discharging flexibility, reduced fuel consumption and lower CO 2 emissions compared to conventional Combined Cycle Power Plants, and low-cost, large-scale energy storage. The LSCC technology is composed of proven equipment integrated with gas turbine exhaust heat in a novel system. During charging, electric heaters raise the salt temperature as it flows from the Cold Salt Tank to the Hot Salt Tank. During discharging, hot salt produces steam from feedwater that is heated with gas turbine exhaust, which also superheats steam to drive a steam turbine. LSCC technology can be added to any combustion-turbine to integrate renewable energy, provide needed grid services, and increase the value of fossil electric generating units based on the technology’s following attributes: • Long-duration storage enables time-shifting of VRE to avoid curtailment and impairment of renewable assets. • Long storage duration combined with fast-charging capability increases arbitrage opportunities by storing more energy when the price is low and discharging more hours when the price is high. • Long storage duration allows resource adequacy to be supplied across multiple days to increase reliability and reduce risk. • The stored energy reduces fuel heat rate and GHG emissions, and increases merit, so the LSCC dispatches earlier and longer to increase the plant’s capacity factor and asset value. • The stored energy enables pre-heating and startup of the steam cycle, without operating the gas turbine, to enable fast startup and ramping when dispatched for discharge. • The steam turbine can operate without the gas turbine so it can provide valuable synchronous inertia during charging without consuming fuel. • Fast frequency response and regulation services can be provided during charging using solid-state heater and pump controls to vary the charge power input in response to grid signals. • The LSCC system can be configured for resilience including black start, islanded/micro-grid operation, and even self-recharging of storage using either gas turbine power or gas turbine exhaust heat. The commercialization plan is to add LSCC technology to existing simple cycle gas turbine power plants with the 50MW GE LM6000 aero-derivative gas turbine as the reference design basis. A Techno-economic assessment of the reference design evaluated the benefits (Levelized Avoided Cost of Energy) and costs (Levelized Cost of Energy). The plant definition included all major systems and budgetary vendor quotes. Pintail Power and NexantECA developed the overall cost estimate for the LSCC plant up to the total plant cost level, following the DOE-NETL cost estimate guidelines at AACE Class 3 (-20%/+30%). This includes the equipment cost, bulk material, direct and indirect labor costs to arrive at the bare erected cost. Engineering costs are factored from the BEC and added to it to arrive at the EPC cost. Process and project contingencies were then factored from the EPC cost and rolled-up to yield the total plant cost of $\$$184 million for 1746 MWh of discharge electricity. • At $\$$105/kWh, the reference plant costs less than any of the Energy Storage Systems evaluated by PNNL in 2020 for the Energy Storage Grand Challenge. Operations and Maintenance cost estimates were scaled from combined cycle practice, assuming that the LSCC unit was co-located with and sharing some labor expense with other units, to arrive at $\$$2.2 million per year. Plant economics were evaluated using prices from the ERCOT Day-Ahead Market for calendar year 2019 (excluding the market disruptions from the COVID pandemic and the February 2020 deep freeze event). Assuming economic dispatch in the ERCOT Day-Ahead market, the reference plant capacity factor would have discharged for 2777 hours at 91.9 MW, a 31.66% capacity factor, with a marginal cost of $\$$25.59/MWh, and a LACE of $\$$82.41/MWh. Fixed charges were calculated according to EIA guidelines to arrive at an LCOE of $\$$83.48. The benefit-to-cost ratio of 0.99 suggests that the reference plant would have been cost-effective and competitive in the market. EPRI interviewed selected utilities to gauge the need for, applicability of and interest in the LSCC system. Several utilities are currently managing increased load growth along with the inclusion of increasing levels of renewable generation, putting pressure on conventional generation by requiring increased turndown requirements and ultimately lower capacity factors. All of the utilities interviewed have CO 2 reduction targets in the 2030-2050 timeframe that will severely limit the participation of fossil generation and require better utilization of carbon free generation. While there is limited opportunity for storage in the current markets, the utilities interviewed stated that there will be a substantial need for long duration energy storage in the future given the expected trends. Utilizing an energy storage system will generally be preferred over new gas capacity in some cases, with the capabilities of the LSCC system being a potential option for retrofit to existing simple cycle gas turbine units, allowing them to deliver greater participation in the market with lower carbon intensity. A technology gap assessment and technology maturation plan identified a pilot-scale demonstration as the final step before commercialization. Key gaps to be addressed during the Phase II FEED (Front-End Engineering Design) are component selection and design, commissioning procedures, and operational procedures and the control system for LSCC charging and discharging. The project team has been expanded to include Wood Group PLC as EPC. The proposed Phase II work leads to a pilot-scale engineering demonstration (TRL 6) to be conducted at Southern Company’s Plant Rowan, where the prototype system will perform “all the functions that will be required of the operational system.” The proposed pilot will facilitate commercialization (TRL-9) by scale-up to utility-scale systems integrated with peaking GTs or directly to facility scale systems using industrial GTs. The conceptual design for the pilot plant focuses on the novel integration aspects of LSCC technology. A slipstream of gas turbine exhaust will feed a waste heat recovery unit coupled to a molten salt steam generator heated by stored energy. The pilot is intended to demonstrate all key operating modes of the LSCC technology during charging, discharging and standby. The pilot equipment will be approximately one-seventh scale of the LM6000 commercial target and is expected to have commercial off-ramp potential for facility-scale applications.

01 COAL, LIGNITE, AND PEAT↗

Secure System Composition and Type Checking using Cryptographic Proofs [Slides]

We can use formal methods to verify that systems compose correctly without the possibility of incorrect behavior. This means exhaustively checking that System A’s postconditions agree with System B’s preconditions. If so, it is safe to compose. Normal Setting: Every computational path must be accounted for and checked. Verification cost (time) is multiplicative across systems.

97 MATHEMATICS AND COMPUTING↗

Method for controlling fiber growth in a laser heated pedestal growth system by controlling a laser power output, a pedestal feedstock rate of motion, and a draw rate

One or more embodiments relate to a method for controlling fiber growth and fiber diameter in a laser heated pedestal growth (LHPG) system so as to provide long, continuous single-crystal optical fibers of uniform diameter. The method generally provides three independent parameter feedback controls to control the molten zone height, laser power, and fiber drawing rates simultaneously in order to reduce the mismatch between instantaneous diameter changes and current diameter. The method permits the growth of fibers with non-uniform diameters along the fiber's length. The method also provides the capability to stop the LHPG system, remove the exhausted pedestal feedstock with a second pedestal feedstock, and restart the LHPG system to provide a continuous fiber.

Buric, Michael P.↗

Overview of design developments for Condensable Vapor Devices for ITER

The Condensable Vapor Devices (CVDs), which are part of the ITER Roughing Pump System (RPS), are designed to separate tritiated water content to protect downstream pumps and transfer the water to Tokamak Exhaust Processing (TEP) systems for further separation. CVDs operate on the principle that a cooling fluid, such as liquid nitrogen, cools the exhaust gas stream (process gas) from the Tokamak, allowing the water present in the process gas to condense and freeze, thereby trapping it in the CVDs. The CVDs once saturated with the ice are then regenerated to release the trapped water molecules, which are sent to the TEP. The present article will describe the technical requirements, challenges, and design progress made so far in the development of the CVDs.

Choukekar, Ketan [ORNL] (ORCID:0009000288016383)↗

Modeling Exhaust-Generated Aerodynamic Pressure Loads on Airfield Matting Repair Systems

Airfield matting systems are commonly used for rapid repair of damaged runways to facilitate continuity of critical operations. Under normal service conditions, matting repair systems are subject not only to wheel loads exerted by airfield traffic but also to aerodynamic pressure loads resulting from high-speed, turbulent exhaust plumes produced by jets during taxi and take-off. Matting systems employed by the U.S. Air Force have been tested with respect to wheel loads, but probabilities of failure because of pressure loads produced by jet exhaust have not yet been established. This study presents a numerical approach for preliminary estimation of worst-case matting anchor forces resulting from exhaust-generated pressure loads. Using a two-dimensional computational fluid dynamics model, system behavior is evaluated by means of a parametric study of six system variables, of which the most significant are: (1) distance between engine and matting, (2) depth of cavity openings at matting edges, and (3) engine exhaust velocity. The results demonstrate that matting systems are likely to experience net uplift in typical service scenarios, driven by the combined effects of flow separation and cavity pressurization. Worst-case anchor pull-out forces, computed according to a tributary-area approach, are estimated to fall in the range of 130 lb (581 N) to 979 lb (4,350 N), depending on assumed load-sharing behavior among anchors and the size of the repair site. Field testing of instrumented matting systems during jet taxi and take-off sequences is recommended as the best next step toward understanding system behavior.

Engineering↗

Hybrid Fuel Cell—Supercritical CO2 Brayton Cycle for CO2 Sequestration-Ready Combined Heat and Power

The low prices and its relatively low carbon intensity of natural gas have encouraged the coal replacement with natural gas power generation. Such a replacement reduces greenhouse gases and other emissions. To address the significant energy penalty of carbon dioxide (CO2) sequestration in gas turbine systems, a novel high efficiency concept is proposed and analyzed, which integrates a flame-assisted fuel cell (FFC) with a supercritical CO2 (sCO2) Brayton cycle air separation. The air separation enables the exhaust from the system to be CO2 sequestration-ready. The FFC provides the heat required for the sCO2 cycle. Heat rejected from the sCO2 cycle provides the heat required for adsorption-desorption pumping to isolate oxygen via air separation. The maximum electrical efficiency of the FFC sCO2 turbine hybrid (FFCTH) without being CO2 sequestration-ready is 60%, with the maximum penalty being 0.68% at a fuel-rich equivalence ratio (Φ) of 2.8, where Φ is proportional to fuel-air ratio. This electrical efficiency is higher than the standard sCO2 cycle by 6.85%. The maximum power-to-heat ratio of the sequestration-ready FFCTH is 233 at a Φ = 2.8. Even after including the air separation penalty, the electrical efficiency is higher than in previous studies.

10 SYNTHETIC FUELS↗

An experimental and numerical investigation of HD diesel engine DOC efficiency in oxidizing NO to NO 2

Reducing pollutant emissions from heavy-duty (HD) diesel engines is critical due to their significant environmental impact, particularly concerning NOx emissions. Understanding and optimizing modern diesel oxidation catalyst (DOC) and selective catalytic reduction (SCR) performance is essential for improving exhaust aftertreatment (EAT) system efficiency to meet stringent emissions regulations. The oxidation of nitric oxide (NO) to nitrogen dioxide (NO 2 ) in DOC plays a key role in improving SCR efficiency in reducing NO x . This study investigates the DOC performance in oxidizing NO to NO2 and its impact on the SCR efficiency of a 2021 MY Navistar E39 HD diesel engine. The influence of engine speed, load, exhaust gas temperature, and composition on DOC efficiency is experimentally investigated. The relationships between DOC inlet temperature, oxygen availability and NO 2 /NO x ratio at the DOC inlet are examined to better understand their effects on the overall DOC efficiency. The results indicate that DOC NO oxidation efficiency is highly dependent on exhaust temperature, with optimal oxidation occurring within a specific temperature range (275-350°C). Below this threshold, the chemical reactions are kinetically limited, while at higher temperatures, thermodynamic constraints reduce the efficiency of DOC in oxidizing NO to NO 2 . The experimental data further reveal that the NO 2 /NO x ratio peaks at medium loads before declining at higher loads due to reduced residence time and mass transfer effects. Additionally, the SCR NO x conversion efficiency is significantly influenced by the NO 2 /NO x ratio, achieving peak performance when the NO 2 /NO x ratio approaches 0.5. A DOC chemistry model was developed and validated against the experimental data to predict DOC oxidation behavior under various operating conditions. The findings of this study provide insights into the interdependencies between DOC and SCR performance, contributing to the optimization of SCR systems for optimized NOx reduction.

33 ADVANCED PROPULSION SYSTEMS↗

Design and Modeling of a Demonstration-scale ORC Cycle for the Liquid Air Combined Cycle

Energy storage is becoming an increasing focus for the future energy markets. One potential hybrid system for ling duration energy storage is the Liquid Air Combined Cycle (LACC). The LACC utilizes excess renewable energy to liquefy and store air during the charge cycle. During its discharge cycle, the system uses the exhaust heat from a conventional combustion turbine and an ORC bottoming cycle to vaporize and superheat the stored air that has been pressurized, which is subsequently expanded to atmosphere through a turbine. During the development of the cycle, it has been identified that the main technologies to advance the cycle are the ORC bottoming cycle machinery and the coupled operation between the liquified air subsystem and the ORC subsystem. This paper presents modeling and simulation of the LACC that involves ORC conditions that fall outside the operating regime of more common applications. Due to the low temperatures of liquified air, the ORC system operates on the order of -70°C for the pump, and the turbine has a pressure ratio around 40. The conceptual design of a demonstration system has been developed that focuses on these challenges in order to advance the overall system.

Pryor, Owen↗

Impact of Intake and Exhaust Ducts on the Recovery Efficiency of Heat Recovery Ventilation Systems

The heat recovery efficiency of ventilation systems utilizing heat recovery ventilators (HRVs) depends not only on the heat recovery efficiency of the HRV units themselves but also on the intake and exhaust ducts that connect the HRV units to the outside environment. However, these ducts are often neglected in heat loss calculations, as their impact on the overall heat recovery efficiency of HRV systems is often not understood and, to the knowledge of the authors, a mathematical model for the overall heat recovery efficiency of HRV systems that accounts for these ducts has not been published. In this research, a mathematical model for the overall heat recovery efficiency of HRV systems that accounts for the intake and exhaust ducts was derived and validated using real-life data. The model-predicted decrease in heat recovery efficiency due to the ducts was in reasonable agreement (relative error within 20%) with the real-life measurements. The results suggest that utilizing this model allows for more correct ventilation heat loss calculations compared to using the heat recovery efficiency of the HRV unit alone, but more field studies are needed to verify the accuracy of this model in a wide range of applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ventilation: Fume Hoods Self-Study Course # 48002

This course presents an overview of the requirements and safe work practices for the use of engineered ventilation controls (EVCs) at Los Alamos National Laboratory (LANL). EVCs addressed in this manual include fume hoods, local exhaust ventilation (LEV) systems other than fume hoods, portable and in-place high-efficiency particulate air (HEPA) filtration systems. Requirements from LANL Procedure P101-16, Industrial Ventilation (non-HVACR) that address EVC certification and use, along with responsibilities of workers who use EVCs and the responsible line managers (RLMs) of such workers, are also presented. Per 101-16, 6.1, workers who use, maintain, or certify (i.e., inspect and test) fume hoods, or Persons in Charge (PICs) who oversee others in those tasks, must complete this course.

42 ENGINEERING↗

Crystallographic Orientation Dependence of Mechanical Responses of FeCrAl Micropillars

Iron-chromium-aluminum (FeCrAl) alloys are used in automobile exhaust gas purifying systems and nuclear reactors due to its superior high-temperature oxidation and excellent corrosion resistance. Single-phase FeCrAl alloys with a body centered cubic structure plastically deform through dislocation slips at room temperature. Here, we investigated the orientation dependence of mechanical responses of FeCrAl alloy through testing single-crystal and bi-crystal micropillars in a scanning electron microscopy at room temperature. Single-crystal micropillars were fabricated with specific orientations which favor the activity of single slip system or two slip systems or multiple slip systems. The strain hardening rate and flow strength increase with increasing the number of activated slip system in micropillars. Bi-crystal micropillars with respect to the continuity of slip systems across grain boundary were fabricated to study the effect of grain boundary on slip transmission. The high geometrical compatibility factor corresponds to a high flow strength and strain hardening rate. Experimental results provide insight into understanding mechanical response of FeCrAl alloy and developing the mechanisms-based constitutive laws for FeCrAl polycrystalline aggregates.

36 MATERIALS SCIENCE↗

Examination of a Methane/Diesel RCCI Engine Using Pele: Preprint

Multi-fuel, advanced injection strategies have become increasingly promising as a strategy to mitigate the emissions generated from internal combustion engines. By carefully controlling the combustion phasing in-cylinder, these new multi-pulse, multi-fuel injection strategies are able to burn in the low-temperature combustion regime where both NOx and soot are not readily produced, reducing the need for extensive exhaust gas recirculation systems. In this study, we examine a reactivity-controlled compression ignition (RCCI) strategy that uses an early pre-filled methane-air mixture with low turbulence background as the low-reactivity fuel and a direct injection of four discrete dodecane jets as a surrogate for the high-reactivity diesel fuel. We use the Pele software suite, a highly optimized, exascale-ready, adaptive mesh refinement codebase to perform high-resolution numerical simulations of a scaled down, single cylinder from the RCCI engine. Here, we resolve the ignition kernels down to micrometer scales and present several statistical quantities evaluating the development of the flow and detailing the onset of ignition and subsequent flame development. Particular attention is paid to the conditions surrounding the onset of the first ignition kernels and discussing what led to the development of those conditions.

CFD↗

An optimization approach for cryogenic distillation-based protium removal systems in magnetic fusion energy fuel cycles

Tritium inventory reduction for fusion power plants is central to the successful adoption of fusion energy. The advent of direct internal recycling in deuterium-tritium fusion fuel cycle design has led to significant reduction in startup tritium inventory estimates for fusion power plants but requires an isotope rebalancing and protium removal (IRPR) system to ensure acceptable isotopic fuel composition. Cryogenic distillation is a potential solution for near-term deployment in an IRPR system due to its demonstrated performance in similar operating regimes. Using protium removal in the fuel cycle as the primary performance metric, this paper presents an optimization methodology for a single-column continuous cryogenic distillation-based IRPR system for a 500 MW fus magnetic fusion device. Distillation column optimization was performed using the CryOgenic Distillation For Isotopic Separation of Hydrogen (CODFISH) code developed at Savannah River National Laboratory. The distillation column design presented maximizes direct recycling of hydrogen isotopes from the fusion chamber exhaust to the fueling system while minimizing IRPR system steady-state tritium inventory. The optimized IRPR distillation column presented achieves direct recycling of 60 % of the hydrogen isotopes in the fusion chamber exhaust with an estimated steady-state system tritium inventory <30 g. In conclusion, the optimized IRPR distillation column operation was then used to estimate the design requirements for a detritation column to treat the IRPR system effluent stream.

CryOgenic distillation↗

Motor Control Center Design

This poster contains information dealing with the design of a Motor Control Center that drives an exhaust, heating and lighting system inside a deep well house.

24 POWER TRANSMISSION AND DISTRIBUTION↗