Search NASA⌕ Search

SEARCH · Search NASA

Results for “EXPECTATION VALUE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

The anisotropy in the xosmic microwave background at degree angular scales

We detect anisotropy in the cosmic microwave background (CMB) at degree angular scales and confirm a previous detection reported by Wollack et al. (1993). The root-mean-squared amplitude of the fluctuations is 44(sup+13)(sub -7)microK. This may be expressed as the square root of the angular power spectrum in a band of multiples between l(sub eff)=69(sup +29)(sub -22). We find delta T(sub l) = square root of (l(2l+1) expected value of ((absolute value of (a(sup m)(sub L)))(exp 2))/(4xpi))= 42(sup +12)(sub -7). The measured spectral index of the fluctuations is consistent with zero, the value expected for the CMB. The spectral index corresponding to Galactic free-free emission, the most likely foreground contaminant, is rejected at approximately 3 sigma. The analysis is based on three independent data sets. The first, taken in 1993, spans the 26-36 GHz frequency range with three frequency bands; the second was taken with the same radiometer as the first but during an independent observing campaign in 1994; and the third, also taken in 1994, spans the 36-46 GHz range in three bands. For each telescope position and radiometer channel, the drifts in the instrument offset are less than or equal to 4 microK/day averaged over a period of 1 month. The dependence of the inferred anisotropy on the calibration and data editing is addressed.

Netterfield, C. B.↗

Calibration Software for Use with Jurassicprok

The Jurassicprok Interferometric Calibration Software (also called "Calibration Processor" or simply "CP") estimates the calibration parameters of an airborne synthetic-aperture-radar (SAR) system, the raw measurement data of which are processed by the Jurassicprok software described in the preceding article. Calibration parameters estimated by CP include time delays, baseline offsets, phase screens, and radiometric offsets. CP examines raw radar-pulse data, single-look complex image data, and digital elevation map data. For each type of data, CP compares the actual values with values expected on the basis of ground-truth data. CP then converts the differences between the actual and expected values into updates for the calibration parameters in an interferometric calibration file (ICF) and a radiometric calibration file (RCF) for the particular SAR system. The updated ICF and RCF are used as inputs to both Jurassicprok and to the companion Motion Measurement Processor software (described in the following article) for use in generating calibrated digital elevation maps.

Chapin, Elaine↗

Multilevel Monte Carlo Estimation of Unbiased Expectation via Sample Reuse and the Low Variance Estimation of Asymptotic Rates

A new variant of the multilevel Monte Carlo estimator [5, 3, 9, 12] is presented for the estimation of expectation statistics that utilizes sample reuse in specified levels, explicitly removes approximation error bias associated with numerically computed output quantities of interest that have an asymptotic limit behavior, and permits a low variance estimate of the asymptotic rate of convergence to that limit. In addition, it is shown that this new multilevel Monte Carlo variant can yield a computational cost savings. A review of Monte Carlo and multilevel Monte Carlo estimators is presented that includes analysis of expected value, expected mean squared error, and the calculation of optimized multilevel sample size parameters. The multilevel Monte Carlo estimator produces estimates of expectation for numerically approximated output quantities of interest that are biased by approximation error. When the quantity of interest can be modeled as the asymptotic limit of numerically approximated output quantities of interest, it is theoretically possible to remove this approximation error bias in the multilevel Monte Carlo estimator. In actual implementations, however, this procedure is unreliable due to statistical variability and inaccuracy in estimating the needed asymptotic limit. Analysis and numerical experiment show that the proposed variant of the multilevel Monte Carlo method greatly reduces (in some cases eliminates) the statistical variability in this limit estimation.

Barth, Timothy↗

Accurate Evaluation of Quantum Integrals

Combining an appropriate finite difference method with Richardson's extrapolation results in a simple, highly accurate numerical method for solving a Schr\"{o}dinger's equation. Important results are that error estimates are provided, and that one can extrapolate expectation values rather than the wavefunctions to obtain highly accurate expectation values. We discuss the eigenvalues, the error growth in repeated Richardson's extrapolation, and show that the expectation values calculated on a crude mesh can be extrapolated to obtain expectation values of high accuracy.

Galant, David C.↗

Accurate Evaluation of Quantum Integrals

Combining an appropriate finite difference method with Richardson's extrapolation results in a simple, highly accurate numerical method for solving a Schrodinger's equation. Important results are that error estimates are provided, and that one can extrapolate expectation values rather than the wavefunctions to obtain highly accurate expectation values. We discuss the eigenvalues, the error growth in repeated Richardson's extrapolation, and show that the expectation values calculated on a crude mesh can be extrapolated to obtain expectation values of high accuracy.

Galant, D. C.↗

Fermionic current densities induced by magnetic flux in a conical space with a circular boundary

We investigate the vacuum expectation value of the fermionic current induced by a magnetic flux in a (2+1)-dimensional conical spacetime in the presence of a circular boundary. On the boundary the fermionic field obeys the MIT bag boundary condition. For irregular modes, a special case of boundary conditions at the cone apex is considered, when the MIT bag boundary condition is imposed at a finite radius, which is then taken to zero. We observe that the vacuum expectation values for both the charge density and azimuthal current are periodic functions of the magnetic flux with the period equal to the flux quantum whereas the expectation value of the radial component vanishes. For both exterior and interior regions, the expectation values of the current are decomposed into boundary-free and boundary-induced parts. For a massless field the boundary-free part in the vacuum expectation value of the charge density vanishes, whereas the presence of the boundary induces nonzero charge density. Two integral representations are given for the boundary-free part in the case of a massive fermionic field for arbitrary values of the opening angle of the cone and magnetic flux. The behavior of the induced fermionic current is investigated in various asymptotic regions of the parameters. At distances from the boundary larger than the Compton wavelength of the fermion particle, the vacuum expectation values decay exponentially with the decay rate depending on the opening angle of the cone. We make a comparison with the results already known from the literature for some particular cases.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

On the onset of the plasmoid instability

A numerical study of magnetic reconnection in two-dimensional resistive magnetohydrodynamics for marginally unstable Sweet-Parker current sheets that are subject to plasmoid formation is carried out. Despite the procedure used to form the primary Sweet-Parker-like current layer, that is different with respect to previous studies, the reconnection layer is unstable to the plasmoid instability for a Lundquist number greater than the expected critical value S{sub c} Almost-Equal-To 10{sup 4}. For Lundquist numbers S Greater-Than-Or-Equivalent-To S{sub c}, the instability exhibits a quasi-periodic behaviour consisting of formation, rapid growth, and evacuation of a moving magnetic island. The so called 'plasmoid' breaks up the primary current layer and significantly enhances the maximum current density over the value expected from Sweet-Parker theory. This local enhancement spatially coincides with the downstream X-point of the magnetic island and is associated with the formation of a pair of slow-mode Petschek-like shocks bounding the outflowing plasma. These results suggest that the inter-plasmoid current layers forming in high-Lundquist-number plasmas (S Much-Greater-Than S{sub c}) could not be simply described as marginally stable Sweet-Parker current sheets.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effective Missing Value Imputation Methods for Building Monitoring Data

To understand behaviors of natural and man-made events, such as energy consumption of buildings, which accounts for 40% of energy uses in the US, we deploy automated monitoring devices to record periodic observations. However, such experimental and observation data often contains problems and irregularities that have to be cleaned up before analyses. Due to various conditions affecting sensor operations, the communication channels, recording steps, or the recording media, the recorded data might have missing values, errors, or anomalous values. An effective way to clean up these problems is to replace these missing values, errors and anomalous values with expected values, a process generally known as imputation. In this work, we survey commonly used missing value imputation techniques and compare their performance on a set of building monitoring data. To compare the different types of sensor measurements with widely varying characteristics, we use normalized root mean squared error (NRMSE) as the key metric for the effectiveness of the imputation methods. We additionally consider periodicity and run time when considering comparing methods. Through extensive testing, we find that for small gap sizes, up to 8 consecutive missing values, linear interpolation performs the best; for larger gaps stretching up to 48 consecutive missing values, K-nearest neighbors provides the most accurate imputations; for even larger gaps, more computational intensive methods, such as matrix factorization, achieve the smallest NRMSE. Additionally, we observe that these computationally intensive algorithms not only provide accurate imputations for large gaps, but are also more robust across all types of sensors.

Cho, B↗

SU-F-T-274: Modified Dose Calibration Methods for IMRT QA

Purpose: To investigate IMRT QA uncertainties caused by dose calibration and modify widely used dose calibration procedures to improve IMRT QA accuracy and passing rate. Methods: IMRT QA dose measurement is calibrated using a calibration factor (CF) that is the ratio between measured value and expected value corresponding to the reference fields delivered on a phantom. Two IMRT QA phantoms were used for this study: a 30×30×30 cm3 solid water cube phantom (Cube), and the PTW Octavius phantom. CF was obtained by delivering 100 MUs to the phantoms with different reference fields ranging from 3×3 cm2 to 20×20 cm{sup 2}. For Cube, CFs were obtained using the following beam arrangements: 2-AP Field - chamber at dmax, 2-AP Field - chamber at isocenter, 4-beam box - chamber at isocenter, and 8 equally spaced fields and chamber at isocenter. The same plans were delivered on Octavius and CFs were derived for the dose at the isocenter using the above beam arrangements. The Octavius plans were evaluated with PTW-VeriSoft (Gamma criteria of 3%/3mm). Results: Four head and neck IMRT plans were included in this study. For point dose measurement with Cube, the CFs with 4-Field gave the best agreement between measurement and calculation within 4% for large field plans. All the measurement results agreed within 2% for a small field plan. Compared with calibration field sizes, 5×5 to 15×15 were more accurate than other field sizes. For Octavius, 4-Field calibration increased passing rate by up to 10% compared to AP calibration. Passing rate also increased by up to 4% with the increase of field size from 3×3 to 20×20. Conclusion: IMRT QA results are correlated with calibration methods used. The dose calibration using 4-beam box with field sizes from 5×5 to 20×20 can improve IMRT QA accuracy and passing rate.

60 APPLIED LIFE SCIENCES↗

Wightman function and vacuum densities in de Sitter spacetime with toroidally compactified dimensions

We investigate the Wightman function, the vacuum expectation values of the field squared, and the energy-momentum tensor for a scalar field with a general curvature coupling parameter in (D+1)-dimensional de Sitter (dS) spacetime with an arbitrary number of compactified spatial dimensions. Both cases of periodicity and antiperiodicity conditions along the compactified dimensions are considered. Recurrence formulas are derived which express the vacuum expectation values for the dS spacetime of topology R{sup p}x(S{sup 1}){sup q} in the form of the sum of the vacuum expectation values in the topology R{sup p+1}x(S{sup 1}){sup q-1} and the part induced by the compactness of the (p+1)th spatial dimension. The behavior of the topological parts is investigated in various asymptotic regions of the parameters. In the early stages of the cosmological evolution, the topological parts dominate the contribution in the expectation values due to the uncompactified dS part. In this limit the behavior of the topological parts does not depend on the curvature coupling parameter and coincides with that for a conformally coupled massless field. At late stages of the cosmological expansion, the expectation values are dominated by the part corresponding to uncompactified dS spacetime. The vanishing of the topological parts is monotonic or oscillatory in dependence of the mass and the curvature coupling parameter of the field.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Majorant recursions to determine eigenstate bounds of a symmetric exponential quantum anharmonic oscillator

The determination of the energy states is highly studied issue in the quantum mechanics. Based on expectation values dynamics, energy states can be observed. But conditions and calculations vary depending on the created system. In this work, a symmetric exponential anharmonic oscillator is considered and development of a recursive approximation method is studied to find its ground energy state. The use of majorant values facilitates the approximate calculation of expectation values.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Bayesian optimization of generalized data

Direct application of Bayes' theorem to generalized data yields a posterior probability distribution function (PDF) that is a product of a prior PDF of generalized data and a likelihood function, where generalized data consists of model parameters, measured data, and model defect data. The prior PDF of generalized data is defined by prior expectation values and a prior covariance matrix of generalized data that naturally includes covariance between any two components of generalized data. A set of constraints imposed on the posterior expectation values and covariances of generalized data via a given model is formally solved by the method of Lagrange multipliers. Posterior expectation values of the constraints and their covariance matrix are conventionally set to zero, leading to a likelihood function that is a Dirac delta function of the constraining equation. It is shown that setting constraints to values other than zero is analogous to introducing a model defect. Since posterior expectation values of any function of generalized data are integrals of that function over all generalized data weighted by the posterior PDF, all elements of generalized data may be viewed as nuisance parameters marginalized by this integration. One simple form of posterior PDF is obtained when the prior PDF and the likelihood function are normal PDFs. For linear models without a defect this PDF becomes equivalent to constrained least squares (CLS) method, that is, the χ2 minimization method.

Arbanas, Goran↗

The Hubble relation for nonstandard candles and the origin of the redshift of quasars

It is shown that the magnitude-log (redshift) relation for brightest quasars can have a slope different from the value expected for standard candles. The value of this slope depends on the luminosity function and its evolution. Therefore the difference of this slope from the expected value cannot be used as evidence against the cosmological origin of the redshift of the quasars. It is shown that the observed variation of the luminosity of the brightest objects with redshift is consistent with the cosmological hypothesis and that it agrees with (and perhaps could be used to complement) the luminosity function obtained from V/Vm analysis. It is also shown that the nonzero slope of the magnitude-log (redshift) relation rules out the local quasar hypothesis, where it is assumed that the sources are nearby (less than 500 Mpc), that the bulk of their redshift is intrinsic, and that there is no dependence on distance of the intrinsic properties of the sources.

Petrosian, V.↗

Engine monitoring display study

The current study is part of a larger NASA effort to develop displays for an engine-monitoring system to enable the crew to monitor engine parameter trends more effectively. The objective was to evaluate the operational utility of adding three types of information to the basic Boeing Engine Indicating and Crew Alerting System (EICAS) display formats: alphanumeric alerting messages for engine parameters whose values exceed caution or warning limits; alphanumeric messages to monitor engine parameters that deviate from expected values; and a graphic depiction of the range of expected values for current conditions. Ten training and line pilots each flew 15 simulated flight scenarios with five variants of the basic EICAS format; these variants included different combinations of the added information. The pilots detected engine problems more quickly when engine alerting messages were included in the display; adding a graphic depiction of the range of expected values did not affect detection speed. The pilots rated both types of alphanumeric messages (alert and monitor parameter) as more useful and easier to interpret than the graphic depiction. Integrating engine parameter messages into the EICAS alerting system appears to be both useful and preferred.

Hornsby, Mary E.↗

Symmetry breaking and reheating after inflation in no-scale flipped SU(5)

No-scale supergravity and the flipped SU(5)×U(1) gauge group provide an ambitious prototype string-inspired scenario for physics below the string scale, which can accommodate the Starobinsky-like inflation favoured by observation when the inflaton is associated with one of the singlet fields associated with neutrino mass generation. During inflation, the vacuum remains in the unbroken GUT phase, and GUT symmetry breaking occurs later when a field with a flat direction (the flaton) acquires a vacuum expectation value. Inflaton decay and the reheating process depend crucially on GUT symmetry breaking, as decay channels open and close, depending on the value of the flaton vacuum expectation value. Here, we consider the simultaneous cosmological evolution of both the inflaton and flaton fields after inflation. We distinguish weak, moderate and strong reheating regimes, and calculate in each case the entropy produced as all fields settle to their global minima. These three reheating scenarios differ in the value of a Yukawa coupling that introduces mass mixing between the singlets and the 10s of SU(5). Here, the dynamics of the GUT transition has an important impact on the production of gravitinos, and we also discuss the pattern of neutrino masses we expect in each of the three cases. Finally, we use recent CMB limits on neutrino masses to constrain the reheating models, finding that neutrino masses and the cosmological baryon asymmetry can both be explained if the reheating is strong.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Massless scalar field vacuum in de Sitter spacetime

As a spacetime with compact spatial sections, de Sitter spacetime does not have a de Sitter-invariant ground state for a minimally-coupled massless scalar field that gives definite expectation values for any observables not invariant under constant shifts of the field. However, if one restricts to observables that are shift invariant, as the action is, then there is a unique vacuum state. Here we calculate the shift-invariant four-point function that is the vacuum expectation value of the product of the difference of the field values at one pair of points and of the difference of the field values at a second pair of points. We show that this vacuum expectation value obeys a cluster-decomposition property of vanishing in the limit that the one pair of points is moved arbitrarily far from the other pair. We also calculate the shift-invariant correlation of the gradient of the scalar field at two different points and show that it also obeys a cluster-decomposition property. Possible relevance to a putative de Sitter-invariant quantum state for gravity is discussed.

79 ASTRONOMY AND ASTROPHYSICS↗

Detecting the quantum discord of an unknown state by a single observable

We propose a single observable to witness the nonzero quantum discord of an unknown quantum state provided that we have four copies of the state. The expectation value of this observable provides a necessary and sufficient condition for the nonzero quantum discord in 2xN systems and a necessary condition in higher finite-dimensional bipartite systems. Furthermore, a nontrivial lower bound of the quantum discord can be obtained from this expectation value. The proposed observable can be experimentally measured in exactly the same way as the entanglement witness. Moreover, a quantum circuit is designed to determine the expectation value of our observable with four simultaneous local qubit measurements.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Statistical Assessment of Proton Treatment Plans Under Setup and Range Uncertainties

Purpose: To evaluate a method for quantifying the effect of setup errors and range uncertainties on dose distribution and dose–volume histogram using statistical parameters; and to assess existing planning practice in selected treatment sites under setup and range uncertainties. Methods and Materials: Twenty passively scattered proton lung cancer plans, 10 prostate, and 1 brain cancer scanning-beam proton plan(s) were analyzed. To account for the dose under uncertainties, we performed a comprehensive simulation in which the dose was recalculated 600 times per given plan under the influence of random and systematic setup errors and proton range errors. On the basis of simulation results, we determined the probability of dose variations and calculated the expected values and standard deviations of dose–volume histograms. The uncertainties in dose were spatially visualized on the planning CT as a probability map of failure to target coverage or overdose of critical structures. Results: The expected value of target coverage under the uncertainties was consistently lower than that of the nominal value determined from the clinical target volume coverage without setup error or range uncertainty, with a mean difference of −1.1% (−0.9% for breath-hold), −0.3%, and −2.2% for lung, prostate, and a brain cases, respectively. The organs with most sensitive dose under uncertainties were esophagus and spinal cord for lung, rectum for prostate, and brain stem for brain cancer. Conclusions: A clinically feasible robustness plan analysis tool based on direct dose calculation and statistical simulation has been developed. Both the expectation value and standard deviation are useful to evaluate the impact of uncertainties. The existing proton beam planning method used in this institution seems to be adequate in terms of target coverage. However, structures that are small in volume or located near the target area showed greater sensitivity to uncertainties.

62 RADIOLOGY AND NUCLEAR MEDICINE↗