Search NASA⌕ Search

SEARCH · Search NASA

Results for “Electric Vehicle Chargers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Connecting Electric Vehicle Charging Infrastructure to Commercial Buildings

This factsheet from the National Renewable Energy Laboratory aims to describe how EV chargers can be connected to commercial buildings, including considerations for facility managers, and the effects that charging will have on the buildings electrical distribution system.

Better Buildings, electric vehicle charging, comme↗

Solar Energy Extension Project

The town of Stratford plans to develop and own a 6 kilowatt (kW) solar array on the roof of a municipal-owned public pavilion on the town green. A SolarEdge level 2 EV charging station will be installed at the pavilion to be used by the public. The charging station will have one charging port. The town will install 3 air source heat pumps in the library located adjacent to the pavilion to reduce the use of propane to heat the library. The town will install 4 air source heat pumps in the Town Hall to reduce the use of #2 heating oil to heat the facility. The 6 kW solar array will provide electricity to the library to offset electricity usage, and when an EV plugs into the charging station the solar will provide electricity to the charging station. There is no ground disturbance or ground trenching associated with this project. The 6 kW solar array on the roof of the pavilion will include 20 (390) watt all black panels. A SolarEdge level 2 EV charger will be installed at the pavilion with the 240 V inverter. The solar array will provide electricity to the library and when a vehicle plugs into the EV charger the solar array will switch to power the charger. Any excess electricity that is generated by the array and not used by the library or the EV charger will be fed onto the grid and the town will receive a net metering credit applied towards future consumption. There is no ground disturbance associated with the EV charger or solar array, and the town will install signage to direct the public to the charger. The library will install 2 (18,000) BTU ductless air source heat pumps and 1 (24,000) BTU unit. This will significantly reduce the amount of propane required to heat the library. The Town Hall will install 2 (36,000) BTU ductless air source heat pumps and 2 (9,000) BTU units to reduce the amount of #2 heating oil required to heat the building.

14 SOLAR ENERGY↗

Power Conversion Systems Enabled by SiC BiDFET Device

The BiDirectional Field-Effect Transistor (BiDFET) can enable circuit topologies requiring four quadrant switches, that were earlier designed using discrete combinations of MOSFETs, IGBTs, GaN HEMTs and PiN diodes. The monolithic nature of the BiDFET allows lower device count, smaller switch volume, lower inductance, and simpler packaging, and hence more reliable and commercially viable implementation in power electronics converters. Furthermore, the matrix converter topologies, now feasible using BiDFETs, can eliminate the bulky and unreliable dc link capacitors or inductors required for conventional voltage-source or current-source converters in ac-ac and ac dc applications. The 1.2 kV BiDFET has the potential to disrupt all the applications utilizing 1.2 kV switches, including electric vehicle (EV) drivetrain, bidirectional EV chargers, industrial motor drives, solid-state transformers, datacenter power supplies, elevator drives, dc microgrids, energy storage grid integration, solid-state breakers, etc.

42 ENGINEERING↗

PV Inverter Systems Enabled by Monolithically Integrated SiC based Four Quadrant Power Switch (4-QPS) [BiDFET]

The purpose of this project was to develop a new breed of Power Conversion Systems (PCS) for PV integration that is enabled by the newly developed 4-Quadrant Single Die SiC Power Semiconductor Switches (4-QPS) or also referred to as “Bidirectional FET (BIDFET)”. This work includes semiconductor die development, advanced packaging, converter design, development, and testing of 4-QPS enabled hardware prototypes at 1 kW (for single phase residential application) and 10 kW (for three phase commercial application). The BiDirectional Field-Effect Transistor (BiDFET) can enable circuit topologies requiring four-quadrant switches, that were earlier designed using discrete combinations of MOSFETs, IGBTs, GaN HEMTs, and PiN diodes. The monolithic nature of the BiDFET allows lower device count, smaller switch volume, lower inductance, and simpler packaging, and hence more reliable and commercially viable implementation in power electronics converters. The matrix converter topologies, now feasible using BiDFETs, can eliminate the bulky and unreliable dc link capacitors or inductors required for conventional voltage-source or current-source converters in ac–ac and ac–dc applications. The 1.2 kV BiDFET has the potential to disrupt all the applications utilizing 1.2 kV switches, including electric vehicle (EV) drivetrain, bidirectional EV chargers, industrial motor drives, solid-state transformers, datacenter power supplies, elevator drives, dc microgrids, energy storage grid integration, solid-state breakers, etc.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Control Strategy for Improving Resiliency of an DC Fast Charging EV System

As DC fast charging electric vehicle (EV) infrastructure continues to expand, potential challenges loom. One issue is the potential for EV charger outages due to electrical grid voltage transients. Today, EV chargers are expected to disconnect under a severe voltage sag (below 70%) which reduces electric vehicle charging infrastructure resilience. This work proposes a droop-control solution to ride-through voltage sags and maintain operation. The control solution is presented in a controller hardware in the loop platform.

Starke, Michael↗

Estimating the electric vehicle charging demand of multi-unit dwelling residents in the United States

Abstract Early battery electric vehicle (EV) adopters can access home chargers for reliable charging. As the EV market grows, residents of multi-unit dwellings (MUDs) may face barriers in owning EVs and charging them without garage or parking availability. To investigate the mechanisms that can bridge existing disparities in home charging and station deployment, we characterized the travel behavior of MUD residents and estimated their EV residential charging demand. This study classifies the travel patterns of MUD residents by fusing trip diary data from the National Household Travel Survey and housing features from the American Housing Survey. A hierarchical agglomerative clustering method was used to cluster apartment complex residents’ travel profiles, considering attributes such as dwell time, daily vehicle miles traveled (VMT), income, and their residences’ US census division. We propose a charging decision model to determine the charging station placement demand in MUDs and the charging energy volume expected to be consumed, assuming that MUD drivers universally operate EVs in urban communities. Numerical experiments were conducted to gain insight into the charging demand of MUD residents in the US. We found that charging availability is indispensable for households that set out to meet 80% state of charge by the end of the day. When maintaining a 20% comfortable state of charge the entire day, the higher the VMT are, the greater the share of charging demand and the greater the energy use in MUD chargers. The upper-income group requires a greater share of MUD charging and greater daily kWh charged because of more VMT.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Development of a Heavy-Duty Electric Vehicle Integration and Implementation (HEVII) Tool

As demand for consumer electric vehicles (EVs) has drastically increased in recent years, manufacturers have been working to bring heavy-duty EVs to market to compete with Class 6-8 diesel-powered trucks. Many high-profile companies have committed to begin electrifying their fleet operations, but have yet to implement EVs at scale due to their limited range, long charging times, sparse charging infrastructure, and lack of data from in-use operation. Thus far, EVs have been disproportionately implemented by larger fleets with more resources. To aid fleet operators, it is imperative to develop tools to evaluate the electrification potential of heavy-duty fleets. However, commercially available tools, designed mostly for light-duty vehicles, are inadequate for making electrification recommendations tailored to a fleet of heavy-duty vehicles. The main challenge is that light-duty tools do not estimate real-time vehicle mass, a factor that has a disproportionate impact on the energy consumption of large commercial vehicles. The Heavy-Duty Electric Vehicle Integration and Implementation (HEVII) tool advances the state of the art in evaluating electrification potential and infrastructure requirements for fleets of commercial vehicles. In this work, the HEVII tool is demonstrated with non-uniformly sampled telematics data from an existing fleet to assess the suitability for electrification of each individual vehicle, determine optimal locations for charging infrastructure to support a fleet of EVs and analyze associated costs. Payload mass is predicted using sparse ground-truth data for all input drive cycles and an initial data analysis is conducted to assess the characteristics driving behaviors and energy consumption of the fleet using an adaptable vehicle model. Battery size requirements are determined by applying a novel charger placement algorithm to maximize routes that are viable for EVs and balance time delays with infrastructure development costs. This work details and demonstrates the different aspects of the HEVII tool, presenting preliminary results from an example use case.

ADVANCED PROPULSION SYSTEMS↗

Electric Vehicle Supply Equipment (EVSE) Study for Vernon County, Wisconsin [Slides]

Viroqua is a town in Wisconsin with a population of approximately 4,500. The Vernon County Energy district is a local nonprofit in Viroqua that provides energy education, individualized energy consulting and coaching to residents and businesses. They have a very good relationship with our county government and wish to support their efforts. The Vernon County government is currently working on a comprehensive plan and would like to include planning for electric vehicle (EV) charging infrastructure in the plan. They are seeking guidance on logical phases for implementation and identifying the best locations for Level 2 and Level 3 EV chargers. NREL provided technical input on strategic planning for electric vehicle (EV) adoption and electric vehicle supply equipment (EVSE) expansion in Vernon County through the Clean Energy to Communities (C2C) Expert Match technical assistance program. NREL provided strategic planning support for EV expansion planning in Vernon County and siting considerations for locating EVSE.

24 POWER TRANSMISSION AND DISTRIBUTION↗

In-route inductive versus stationary conductive charging for shared automated electric vehicles: A university shuttle service

In-route inductive charging technology, as applied to automated electric vehicles, can help realize a fully automated system of both vehicles and chargers. This study presents a planning optimization analysis for fixed-route automated shuttles supported by in-route inductive charging technology. A techno-economic feasibility of inductive charging was assessed in comparison with stationary charging, including Level 2 AC chargers, and DC fast chargers (DCFCs). This analysis considered both present-day and future vehicle operations and overall system costs. A real project with two circulator Navya Arma shared automated electric vehicles (SAEVs) at the University of Michigan was investigated using real-world collected energy and travel data. The outcomes show that the proper design of quasi-dynamic inductive chargers at designated stops allows SAEVs to realize unlimited driving range and be cost-competitive to DCFC technology. Considering present-day costs and vehicles, low-speed SAEVs can realize charge-sustaining operation at a minimum cost either by implementing a 50-kW inductive charger at two stops with one segment per position and a 29-kWh onboard battery, or by installing a 100-kW inductive charger at one stop with one segment per position and a 28-kWh onboard battery. Overall, considering future costs and vehicles, either a 40-kW charger at one stop with a 29-kWh battery or a 50-kW charger at the north stop with a 14-kWh battery would enable charge-sustaining operation. In addition, quasi-dynamic inductive solution can reduce the onboard battery by about 15% while providing unlimited driving range, but stationary scenarios require about 112% additional battery capacity to support a 12-h driving range.

33 ADVANCED PROPULSION SYSTEMS↗

Effect of positive pulse charge waveforms on cycle life of nickel-zinc cells

Five amp-hour nickel-zinc cells were life cycled to evaluate four different charge methods. Three of the four waveforms investigated were 120 Hz full wave rectified sinusoidal (FWRS), 120 Hz silicon controlled rectified (SCR), and 1 kHz square wave (SW). The fourth, a constant current method, was used as a baseline of comparison. Three sealed Ni-Zn cells connected in series were cycled. Each series string was charged at an average c/20 rate, and discharged at a c/2.5 rate to a 75% rated depth. Results indicate that the relatively inexpensive 120 Hz FWRS charger appears feasible for charging 5 amp-hour nickel-zinc cells with no significant loss in average cycle life when compared to constant current charging. The 1-kHz SW charger could also be used with no significant loss in average cycle life, and suggests the possibility of utilizing the existing electric vehicle chopper controller circuitry for an on-board charger. There was an apparent difference using the 120 Hz SCR charger compared to the others, however, this difference could be due to an inadvertent severe overcharge, which occurred prior to cell failure. The remaining two positive pulse charging waveforms, FWRS and 1 kHz, did not improve the cycle life of 5 amp-hour nickel-zinc cells over that of constant current charging.

Smithrick, J. J.↗

Extreme-scale EV charging infrastructure planning for last-mile delivery using high-performance parallel computing

Here, this paper addresses stochastic charger location and allocation problems under queue congestion for last-mile delivery using electric vehicles (EVs). The objective is to decide where to open charging stations and how many chargers of each type to install, subject to budgetary and waiting-time constraints. We formulate the problem as a mixed-integer non-linear program, where each station-charger pair is modeled as a multiserver queue with stochastic arrivals and service times to capture the notion of waiting in fleet operations. The model is extremely large, with billions of variables and constraints for a typical metropolitan area; even loading the model in solver memory is difficult, let alone solving it. To address this challenge, we develop a Lagrangian-based dual decomposition framework that decomposes the problem by station and leverages parallelization on high-performance computing systems, where the subproblems are solved by using a cutting plane method and their solutions are collected at the master level. We also develop a three-step rounding heuristic to transform the fractional subproblem solutions into feasible integral solutions. Computational experiments on data from the Chicago metropolitan area with hundreds of thousands of households and thousands of candidate stations show that our approach produces high-quality solutions in cases where existing exact methods cannot even load the model in memory. We also analyze various policy scenarios, demonstrating that combining existing depots with newly built stations under multiagency collaboration substantially reduces costs and congestion. These findings offer a scalable and efficient framework for developing sustainable large-scale EV charging networks.

Capacity allocation↗

Caldera_Grid

Caldera Grid is part of Caldera software platform, a suite of collective, open-source tools that was developed to improve the state of the art in modeling the impacts of Electric Vehicle (EV) charging on the grid. Caldera Grid is a co-simulation framework implemented using Hierarchical Engine for Large scale Infrastructure Co-Simulation (HELICS). The framework facilitates the co-simulation of EV charging and Smart Charge Management (SCM) strategies in Caldera Infrastructure Charge Model (ICM) with distribution level grid models in OpenDSS. Vehicle energy needs and charge session requirements generated using Caldera Charge Decision Module (CDM) are fed in as input to Caldera Grid. The EV charging models in Caldera ICM simulates both the uncontrolled charging loads as well as loads modified by the SCM strategies to develop distributed load profiles for each grid node hosting an Electric Vehicle Supply Equipment (EVSE) – also known as chargers. These loads were simulated in OpenDSS alongside existing distribution feeder loads. Each of these models are co-simulated in a HELICS federate. The HELICS co-simulation framework facilitates communication and synchronization between the federates. By co-simulating EV loads and distribution feeder loads, Caldera Grid can assess the potential grid impacts of EV charging on distribution feeders under various grid conditions. A control strategy federate is implemented with an interface where control strategies based on feedback from EV charging status and grid conditions can be developed and implemented. The platform can also support multiple control strategies in a single co-simulation.

Sundarrajan, ManojKumar Cebol↗

Evaluation of semiconductor devices for Electric and Hybrid Vehicle (EHV) ac-drive applications, volume 1

The results of evaluation of power semiconductor devices for electric hybrid vehicle ac drive applications are summarized. Three types of power devices are evaluated in the effort: high power bipolar or Darlington transistors, power MOSFETs, and asymmetric silicon control rectifiers (ASCR). The Bipolar transistors, including discrete device and Darlington devices, range from 100 A to 400 A and from 400 V to 900 V. These devices are currently used as key switching elements inverters for ac motor drive applications. Power MOSFETs, on the other hand, are much smaller in current rating. For the 400 V device, the current rating is limited to 25 A. For the main drive of an electric vehicle, device paralleling is normally needed to achieve practical power level. For other electric vehicle (EV) related applications such as battery charger circuit, however, MOSFET is advantageous to other devices because of drive circuit simplicity and high frequency capability. Asymmetrical SCR is basically a SCR device and needs commutation circuit for turn off. However, the device poses several advantages, i.e., low conduction drop and low cost.

Lee, F. C.↗

Caldera Infrastructure Charge Module (ICM)

Caldera ICM is part of Caldera software platform, a suite of collective, open-source tools that was developed to improve the state of the art in modeling the impacts of Electric Vehicle (EV) charging on the grid. The foundation of Caldera ICM is it’s first-of-its-kind library of high-fidelity charging models for a wide variety of vehicles, validated by test data under a range of operating conditions. The charging models are used to accurately model the EV charging on an electric vehicle supply equipment (EVSE) – also known as a charger. ICM uses as inputs, the EV characteristics such as battery size, battery chemistry (i.e. NMC, LTO), watt hour per mile, inverter efficiency and max charge rate; as well as EVSE characteristics such as max current and supply equipment type (i.e. L2 vs XFC). Using these inputs Caldera ICM creates an uncontrolled charging profile curve for each compatible EV-EVSE pair. These charge profiles can be used stand alone to estimate charge duration given start State Of Charge (SOC) and end SOC or charge energy size given start SOC and charge duration. In Caldera Grid, another tool in the Caldera software platform, these charge profiles are used to represent EV charging as a load on the grid using charge event data such as EV type, SE type, start SOC, final SOC, park start time and park end time. ICM currently supports energy shifting Smart Charge Management (SCM) strategies such as "Time Of Use (TOU) immediate”, “TOU random” and “random start” by delaying the charge to start at a preferable time with respect to the strategy and, one voltage support SCM strategy named autonomous voltage control strategy by providing reactive power back to the electric grid.

Sundarrajan, ManojKumar Cebol↗

Optimized System for On-Route Fast Charging of Battery-Electric Shuttle Buses

Electrifying cars, buses, and trucks is an attractive means of reducing energy use and emissions because it involves more efficient drivetrain components and minimal restructuring of the transportation network. Transit buses, driving fixed routes, help minimize driver range anxiety by properly sizing energy storage systems. A major challenge to fully electrifying transit buses is providing the amount of energy they consume in a day of driving. To enable a full day of operation without charging, batteries need to be large, which could be expensive and heavy. This work utilizes real-world transit bus data used in a battery-electric drivetrain model to co-optimize charger locations, charger power levels, and vehicle battery sizes.

ADVANCED PROPULSION SYSTEMS↗

Pull Force Evaluation of CCS Insulated End Caps

Insulated end caps installed on DC pins of Combined Charging System (CCS) inlets have been identified as potential debris sources within electric vehicle supply equipment (EVSE) connectors, increasing the risk of electric shock and fire hazards. Although standards such as IEC 62196-1:2022 specify mechanical pull-force requirements for these end caps, it remains unclear whether these requirements provide adequate robustness under real-world conditions. To address this concern, the National Charging Experience (ChargeX) Consortium's Hardware Task Force conducted evaluations of insulated end caps used in OEM CCS inlets. This study assesses the performance of insulated end caps used in OEM CCS inlets, specifically those installed on DC pins, using the procedures defined in IEC 62196-1:2022 (Section Sign) 26.7 and SAE J3400, supplemented by additional experimental conditioning. To ensure relevance to real-world conditions, NLR collaborated with charging network operators (CNOs) to guide the selection of charging inlet samples. Material analyses of the insulated end cap samples were conducted to confirm that the tested materials reflected the types and properties commonly observed in the field. The selected samples underwent temperature and humidity conditioning followed by pull-force testing to evaluate the end-cap integrity. Although SAE J3400 inlets were not directly tested due to limited diversity in available field data, the underlying end-cap principles between CCS and SAE J3400 are comparable, allowing the study's insights to be relevant to both technologies. Overall, this study provides a structured evaluation framework to inform potential refinements to mechanical pull-force requirements in charging standards.

33 ADVANCED PROPULSION SYSTEMS↗

Electric Medium- and Heavy-Duty Vehicle Charging Infrastructure Attributes and Development

Although more established for light-duty vehicles (LDVs), advancements in electric vehicle (EV) charging technology are being made in the medium- and heavy-duty (MD/HD) sector. Progress is also being made with the electrification of MD/HD vehicles, including transit buses, school buses, MD trucks, and HD trucks. The diverse set of operational requirements and duty cycles for each vocation, as well as the range in the size of fleets, present unique charging and infrastructure requirements. This report focuses on charging requirements for MD/HD vehicles and synergies with LDV infrastructure. This analysis leans toward the qualitative rather than quantitative because relevant model inputs are in development and will not be established for a few years, as EV deployments are more mature in the LDV sectors than MD/HD. The report begins with an overview of MD/HD vehicle classes and types of charging, including depot and residential charging, among others (Section 2). Section 3 analyzes the home bases (overnight dwell locations) of existing MD/HD vehicles, with an emphasis on depot and residential home bases, and discusses implications for charging infrastructure. Section 4 discusses the key characteristics for determining if, when, and where MD/HD vehicles can leverage LDV charging infrastructure rather than requiring dedicated chargers. These considerations include electricity demand, connectors, physical space requirements, payment considerations, and impacts on the grid. Section 5 summarizes shared characteristics for MD/HD vehicles that are appropriate for near-term electrification and includes a summary of the outlook of the electric MD/HD vehicle market. The conclusion (Section 6) summarizes the report's findings and outlines areas for future research.

24 POWER TRANSMISSION AND DISTRIBUTION↗