Search NASA⌕ Search

SEARCH · Search NASA

Results for “Electrical Isolation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Topological flat bands in a family of multilayer graphene moiré lattices

Moiré materials host a wealth of intertwined correlated and topological states of matter, all arising from flat electronic bands with nontrivial quantum geometry. A prominent example is the family of alternating-twist magic-angle graphene stacks, which exhibit symmetry-broken states at rational fillings of the moiré band and superconductivity close to half filling. Here, we introduce a second family of twisted graphene multilayers made up of twisted sheets of M- and N-layer Bernal-stacked graphene flakes. Calculations indicate that applying an electric displacement field isolates a flat and topological moiré conduction band that is primarily localized to a single graphene sheet below the moiré interface. Phenomenologically, the result is a striking similarity in the hierarchies of symmetry-broken phases across this family of twisted graphene multilayers. Our results show that this family of structures offers promising new opportunities for the discovery of exotic new correlated and topological phenomena, enabled by using the layer number to fine tune the flat moiré band and its screening environment.

Electronic properties and materials↗

A method to observe field-region oxide charge and inter-electrode isolation from CV-characteristics of n-on-p devices

Abstract N-on-psilicon sensors will be utilized in the Compact Muon Solenoid (CMS) detector's tracker and High Granularity Calorimeter (HGCAL) in the High Luminosity upgrade of the Large Hadron Collider (HL-LHC). Among their several advantages in terms of radiation hardness over the traditionalp-on-nsensors in the extreme radiation environment of the HL-LHC are electron collection instead of holes and overlapping maxima of weighting and electric fields at the charge-collecting electrodes. The disadvantage of the multi-channel SiO 2 -passivatedn-on-psensors is the generation of an inversion layer under the Si/SiO 2 -interface by a positive interface-oxide-charge (N ox ) that at high densities can compromise the position resolution by creating a conduction channel between the electrodes. This issue is typically addressed by including additional isolnts (p-stp,p-spray) between n + -electrodes. Focusing on the guard-ring regions ofn-on-psensors where no isolation implants are applied between the electrodes, a capacitance-voltage (CV) characterization study of both 6-inch wafer test diodes and 8-inch HGCAL prototype and pre-series sensors showed a distinct threshold voltage (V th,iso ) in theCV-characteristics of a biased n + -electrode when its enclosing guard-ring was left floating. When reproduced by simulations, the measuredV th,iso was found to contain information on the field-regionN ox and indicate the threshold where the two electrodes become electrically isolated by the influence of the reverse bias voltage. Together with previous studies on the inter-electrode isolation of irradiatedn-on-psensors, the results indicate that position sensitiven-on-psensors without isolation implants may be feasible in future HEP experiments.

Instruments & Instrumentation↗

Demonstration of a Novel Technology to Manage Electricity Demand in Grid-Independent Military Microgrids

This research was conducted by the National Renewable Energy Laboratory (NREL) in collaboration with the S&C Electric Inc. through funding provided by the ESTCP. The project demonstrates use of cybersecure Automated Demand Response (ADR) technology to effectively manage microgrid loads during grid-independent, also known as "islanded," operation. When military microgrids become isolated from the main electrical grid, they are required to balance electricity supply and demand locally. Given that local generation may be constrained, the prevailing strategy involves shedding all but the most critical loads by tripping smart circuit breakers, which then necessitate manual resetting. This approach is generally implemented at the building level, which means that the buildings with mission-critical activities are exempt from load management and remain fully powered, whereas those deemed non-critical can experience a complete loss of service. In this research we developed a method that allows building automation systems to selectively control their assets in response to load shedding request from a microgrid controller, avoiding total loss of service in contrast to the conventional control approach. A commercial OpenADR client server by GridFabric is used for communication between the microgrid controller and the building management system (BMS). The microgrid controller monitors both generation capacity and various assets within the microgrid and issues a demand reduction request when necessary. This request is communicated to the OpenADR server via Modbus. Upon receiving the request, the OpenADR server forwards it to the BMS utilizing the OpenADR protocol. The BMS is pre-configured with various levels of load reduction strategies based on the controllable assets available, allowing for a nuanced approach to demand reduction. Both lab and field tests were performed that considered load shedding needed to achieve closed transition into island mode and to accommodate changing loads and power source availability while islanded. A commercial microgrid controller was used for these tests with normal programming within the expected constraints of the system capabilities. That is, the solution did not require any specialized modification to the code base of the controller. Given the latency of the round-trip communication path between the microgrid controller and the various devices involved with the load shed processes, there are certain scenarios for which the demonstrated solution are appropriate and some which are not. The methods described in this report can be used for load shedding/restoration during transitions between islanded and grid-tied modes of operation, as well as accommodating normal variations in load and the need to remove a power source from operation for maintenance. These methods should not be used for scenarios that require load shedding within a second or two such as sudden and unanticipated significant load increases or loss of power sources through equipment faults.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Unified Design Theory for Multi-Port Polyphase Transformers Enabling Scalable Power-Multiplexed EV Fleet Charging Systems

This paper presents a unified analytical design theory for multi-port polyphase transformers, targeting scalable and isolated high-power Electric Vehicle (EV) fleet charging systems with power multiplexing capability. As fleet electrification accelerates, conventional one-to-one charger architectures face significant challenges in infrastructure cost, peak power demand, and low utilization of installed power electronics. Power-multiplexed charging architectures, which dynamically distribute power from a shared pool of converter modules across multiple vehicles, have emerged as a promising solution. However, such architectures require scalable, isolated multi-port power interfaces capable of routing energy among multiple inputs and outputs, whose design remains complex and dependent on iterative modeling. To address this gap, the proposed theory provides closed-form expressions for self-inductance, leakage inductance, and mutual coupling terms for arbitrary multi-phase, multi-port transformer structures. The formulation enables direct synthesis of isolated multi-input and multi-output resonant converter systems without reliance on geometry-specific finite-element analysis or extensive parameter extraction. This capability is particularly critical for power-multiplexed systems, where modular converter structures must interface with multiple vehicles while maintaining galvanic isolation and flexible power allocation. The effectiveness of the proposed framework is demonstrated through the design of a 360 kW multi-phase system operating over a 700–900 VDC input and 400–1250 VDC output range. PLECS simulation results confirm accurate prediction of system behavior and validate the applicability of the approach to multi-port, power-multiplexed charging scenarios. The proposed method significantly reduces design complexity while enabling scalable, cost-effective, and fully utilized EV fleet charging infrastructure.

Asa, Erdem [ORNL] (ORCID:0000000190884812)↗

Highly tunable magnetocrystalline anisotropy energy in Fe3+-doped BaTiO3

Magnetic dopants in ferroelectric oxide host materials provide a platform for electric field control of isolated spins, facilitated by tuning of the magnetocrystalline anisotropy energy (MCAE). We present first-principles calculations of the MCAE experienced by isolated Fe3+ dopants in the tetragonal, orthorhombic, and rhombohedral phases of the prototypical ferroelectric BaTiO3. We identify an order-of-magnitude decrease in the MCAE in the rhombohedral phase relative to the tetragonal and orthorhombic phases. We explain this dramatic decrease, as well as the formation of a spin-easy plane in the tetragonal phase and spin-easy axes in the orthorhombic and rhombohedral phases, using crystal field theory arguments. Building a superposition model from crystal field theory, we show how a set of simple criteria based on crystalline environment can be used to estimate the MCAE. We suggest this as a route to rapidly screen candidate ferroelectric hosts and magnetic dopants that possess phases with spin-easy axes and maximal MCAE tunability.

Barker, Bradford A↗

Multiscale Experiments and Multiphysics Simulation of Multiphase Flow for Transportable Small Modular Reactors

A new type of safe, small, transportable nuclear reactor would address the intense and ever-growing global demand for energy produced via a resilient, carbon-free energy source. In this regard, transportable small modular reactors (SMRs) are being designed and developed for electricity generation within small/micro-grid/off-grid isolated systems, as well as for heat generation in industrial/residential applications. These reactors feature the capability to be fully factory fabricated and then directly transported to utilities’ sites as “plug-and-play” systems. Research and development (R&D) programs are underway at Idaho National Laboratory (INL) to successfully design, develop, and demonstrate such safe-by-design mobile reactor technologies, in collaboration with partner organizations. Multiscale experimental facilities and multiphysics simulation tools are required for reactor design verification and validation (V&V), and licensing. These advanced reactors are intended to feature passive safety systems such as passive containment cooling systems (PCCS), which consist of multiphase flows and multispecies distributions. This seminar talk will focus on designing and analyzing transportable SMR PCCS by using multiscale experiments and multiphysics computational fluid dynamics (CFD) simulations to support reactor licensing and safety. The corresponding research challenges are addressed via supportive verification and validation results generated by the models and simulation tools in combination with selective parametric and uncertainty analysis. This solution approach could blaze the trail for commercial adoption of such technologies. The facilities, simulation capabilities, and research opportunities available at INL in regard to such reactors and the integrated energy systems with which they go hand in hand are also discussed briefly, and may spark interest in deeper research as well as new collaborative projects.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Diagnosing electric and magnetic fields in laser-driven coil targets

Laser-driven capacitor coils are widely used to generate intense magnetic fields for various applications in high-energy-density (HED) physics research. Accurate measurement of the magnetic fields is essential but challenging, due to the overlapping contributions from magnetic and electric fields in proton radiography, which is the primary tool diagnosing the field generation around the coils. In this study, we systematically analyze proton radiographs obtained from laser-driven capacitor-coil targets along two orthogonal axes under various electromagnetic field conditions, including magnetic field only, electric field only, and combined electromagnetic fields. By analyzing key features in the radiographs, we distinguish and characterize the respective contributions from magnetic and electric fields. Using detailed simulations validated by experimental benchmarks, methods to isolate and quantify the magnetic field and electric field are given. The methods are successfully applied to determine the electric current and charge distribution in a double coil configuration. Our findings provide insights into improving the diagnostic capability of proton radiography, potentially leading to more accurate measurements of electromagnetic fields and enhancing the utility of laser-driven capacitor coils in HED experiments.

electromagnetic field diagnostics↗

Providencia Island White Papers: Overview of Technical Requirements for Interconnection

This issue brief provides an overview of key technical requirements for inverter-based resources - including distributed energy resources (DERs) - to support the reliable and safe operation of the Providencia Island electrical grid, and other island or isolated area mini-grid applications. With the planned increase in inverter-based resources and the introduction of energy storage, adopting Institute of Electrical and Electronics Engineers (IEEE) Std 1547-2018, including the more advanced performance capabilities for voltage and frequency ride-through, will simplify interconnection as well as help to maintain a safe, reliable grid on Providencia Island.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High-frequency direct current bulk capacitors with interleaved busbar packages

Presented are electrical capacitors with interleaved busbar architectures, methods for making/operating such capacitors, and electric-drive vehicles equipped with such capacitors. A bulk capacitor includes multiple capacitor devices disposed within an outer housing and operable to modify electric current transmitted between a power source and an electrical load. An interleaved busbar package is interposed between the capacitor devices and outer housing. The interleaved busbar package includes a first busbar plate that electrically connects to first terminals of the capacitor devices and defines a busbar pocket. A second busbar plate is seated within the busbar pocket and electrically connects to second terminals of the capacitor devices. The second busbar plate includes a capacitor basin that seats therein the capacitor devices. An isolator sheet is interleaved between and electrically insulates the first and second busbar plates. The capacitor devices and interleaved busbar package may be partially submerged in an epoxy endfill composition.

42 ENGINEERING↗

A Transactive Approach for Service Restoration Utilizing Customer Load Flexibility and Grid-Edge Resources

This paper develops a transactive energy system model to restore electricity to customers in an isolated distribution system after an outage. The model is developed to engage a variety of customer types - prosumers, flexible loads, critical/noncritical customers, and distributed generators - as active participants in the restoration process. Unlike many existing transactive approaches, the proposed model is developed for service restoration and accounts for various customer types and their autonomy and privacy through an iterative approach to determine the optimal market price, while maintaining systemlevel power flow and voltage constraints. The advantages of the proposed approach are numerically validated on a modified IEEE 123-bus test system.

distributed energy resources↗

Integrating a Microgrid Controller with a Local OpenADR Server

When military microgrids isolate themselves from the main electrical grid, they must locally balance electricity supply and demand. Since local generation may be limited, the current strategy is to shed all but the most critical loads by tripping smart circuit breakers, which must then be reset manually (e.g., ESTCP project EW-201350). This strategy is typically applied at the building level, meaning that entire buildings housing mission critical activities must be excluded from any load management, while those considered non-critical may lose service entirely. The remotely controlled switchgear needed to manage load in this way is very expensive ($\$30,000$-$\$50,000$ per building). While effective at shedding load, this strategy disrupts installation operation and risks damaging equipment during both disconnection and re-energization. With the goals of lowering costs, protecting equipment, and enhancing the agility of DoD microgrids, this report demonstrates the use of cybersecure automated demand response (ADR) technology to manage microgrid loads during grid-independent (a.k.a. "islanded") operation. This automated approach achieves load shedding and shifting through communication signals sent to equipment controllers rather than by cutting off the flow of electricity within the microgrid itself. Because it operates only on the base network, with no connection to external entities, this strategy avoids the main cybersecurity concern raised by past applications of ADR on military bases.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Transactive Approach for Service Restoration Utilizing Customer Load Flexibility and Grid-Edge Resources: Preprint

This paper develops a transactive energy system model to restore electricity to customers in an isolated distribution system after an outage. The model engages a variety of customer types -- prosumers, flexible loads, critical/noncritical customers, and distributed generators -- as active participants in the restoration process. Unlike many existing transactive approaches, the proposed model is developed for service restoration and accounts for various customer types and their \textit{autonomy} and \textit{privacy} through an iterative approach to determine the optimal market price, while maintaining system-level power flow and voltage constraints. The advantages of the proposed approach are numerically validated on a modified IEEE 123-bus test system.

distributed energy resources↗

A Transactive Approach for Service Restoration Utilizing Customer Load Flexibility and Grid-Edge Resources

This paper develops a transactive energy system model to restore electricity to customers in an isolated distribution system after an outage. The model engages a variety of customer types -- prosumers, flexible loads, critical/noncritical customers, and distributed generators -- as active participants in the restoration process. Unlike many existing transactive approaches, the proposed model is developed for service restoration and accounts for various customer types and their autonomy and privacy through an iterative approach to determine the optimal market price, while maintaining system-level power flow and voltage constraints. The advantages of the proposed approach are numerically validated on a modified IEEE 123-bus test system.

distributed energy resources↗

Recent Progress on Numerical Modeling for Microgravity Electric Field Flames: Preprint

This paper presents the recent progress on the NASA Physical Science Informatics (PSI) project PeleLM CFD of Ion Driven Winds from Diffusion Flames in simulating the E-FIELD Flames microgravity results. The focus of this project is to comprehensively simulate the behavior of a small diffusion flame under the influence of an externally applied electric field in zero-gravity. To date, the capability of accurately simulating electric field flames has eluded researchers because the system exhibits dramatic ranges of coupled temporal and spatial scales. Moreover, in earth gravity the hot combustion products are subject to buoyancy effects that are difficult to isolate from those generated by the electric field. This work is an implementation in an existing powerful simulation framework (PeleLM) for this problem using PeleLMeX in order to validate the model and investigate the complex coupled system. The current effort includes establishing the domain of a diffusion coflow burner, examining the boundary conditions, flame geometry and ignition with gravitational forces and also with an electric field applied. A detailed model is used that includes the chemistry of charged ions and chemiluminescent flame intermediates to capture any feedback between ion-driven convection and combustion behavior, and to allow quantitative comparisons with experimental measurements.

coflow flames↗

Laser Cutting and Micromachining for Localized and Targeted Solar Cell Characterization

Laser cutting and micromachining can be applied to solar cell materials for processing and characterization applications. An ultrashort pulse (USP) laser with sub-picosecond pulse width can remove material with minimal thermal effects or damage, which is termed `cold ablation'. Such USP laser cutting and scribing can be implemented for isolating areas within a larger cell while maintaining electrical performance and preventing laser-induced damage and shunting. Laser micromachining has been used to isolate a shunt to improve cell performance and to isolate a small, selected area to define a sample suitable for deep level transient spectroscopy.

14 SOLAR ENERGY↗

Terrestrial Gamma‐Ray Flash Following Intense Negative Return Stroke Observed With BIMAP‐3D

We report ground-based observations of a terrestrial gamma-ray flash (TGF) associated with a strong negative cloud-to-ground lightning strike (-CG) which occurred near Los Alamos National Laboratory (LANL) in New Mexico, USA. Gamma photons were detected by the Terrestrial High-energy Observations of Radiation (THOR) instrument, developed at the University of California, Santa Cruz, which has been hosted at LANL since 2022. Simultaneous measurements were also made with the 3-Dimensional Broadband Interferometric Mapping and Polarization (BIMAP-3D) system, which includes 3D lightning mapping, two fast antennas, and an additional plastic scintillator. Additional field change waveforms were obtained from the Earth Networks Total Lightning Network (ENTLN). The lightning initiated about 1 km above the ground, leading to a powerful -CG with an ENTLN peak current of −237 kA and bipolar field change matching the recently described “energetic compact stroke” (ECS) shape. The TGF was then observed ∼35 µs after the start of the return stroke. We also observe an electric field pulse likely produced by the TGF either in isolation or by coupling to the lightning channel. Based on modeling of the radiated electric field and photon propagation through the atmosphere we infer that the TGF source was on the order of 1⁢0 17 photons. This TGF and associated lightning are extremely similar to some recently reported ECS TGFs in coastal Japan in winter, but we report the first observation of this phenomenon outside of Japan in a different climate, terrain, and season.

58 GEOSCIENCES↗

Reducing the computational burden of a microgrid energy management system

As renewable technology advances and decreases in cost, microgrids are becoming an appealing means of distributed generation both for isolated communities and integrated with existing electrical grid systems. Due to their small size, however, microgrids may have financial limitations which preclude them from using commercial software to optimize control of their assets. Open-source optimization solvers are a viable alternative, but increase computation time. This work expands on a rolling horizon optimization framework for economic dispatch within an existing residential microgrid located in Hoover, Alabama. The microgrid has an open-source solver requirement and a need for quick solution time on a rolling horizon as opposed to a day-ahead commitment. We present a method of reducing integer variables by relaxation which completes two goals: reduction in computation time for real-time operations, and reduction in daily operational cost for the microgrid. Seasonal data for load and photovoltaic (PV) power was also collected from the microgrid to facilitate simulation testing. Computation time was successfully reduced using multiple variations of the relaxation method, while obtaining solution quality with operational cost similar to or better than the original model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Magnetic frame-dragging correction to the electromagnetic solution of a compact neutron star

ABSTRACT Neutron stars are usually modelled as spherical, rotating perfect conductors with a predominant intrinsic dipolar magnetic field anchored to their stellar crust. Due to their compactness, General Relativity corrections must be accounted for in Maxwell’s equations, leading to modified interior and exterior electromagnetic solutions. We present analytical solutions for slowly rotating magnetized neutron stars, taking into account the magnetic frame-dragging correction. For typical compactness values, i.e. Rs ∼ 0.5 [R*], we show that the new terms lead to a per cent order correction in the magnetic field orientation and strength compared to the case, with no magnetic frame-dragging correction. Also, we obtain a self-consistent redistribution of the surface azimuthal current. We verify the validity of the derived solution through two-dimensional particle-in-cell simulations of an isolated neutron star. Defining the azimuthal electric and magnetic field amplitudes during the transient phase as observables, we prove that the magnetic frame-dragging correction reduces the transient wave amplitude, as expected from the analytical solution. We show that simulations are more accurate and stable, when we include all first-order terms. The increased accuracy at lower spatiotemporal resolutions translates into a reduction in simulation runtimes.

Torres, R. (ORCID:0000000291820228)↗